Anko Electronics
4091 E. LA Palma Ave Ste. N, 92807, Anaheim, CA, United States
Visit website- Scope lines
- 12
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 12 scope lines.
A2LA certificate 7815.01 · 12 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 12 in |
| 2 | - | DC Voltage; DC Current; DC ResistanceShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7815.01) Revised 05/29/2026 Page 2 of 11
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 6 (±)
Comments5
DC Voltage – Generate
3
(0 to 329.999) mV
(0 to 3.299 999) V
(0 to 32.999 99) V
(30 to 329.9999) V
(0.1 to 1) kV
6.5 μV
33 μV
0.35 mV
4.9 mV
16 mV
Direct measurement:
Fluke 5520A
multifunction
calibrator
DC Current – Generate3
(0 to 329.999) μA
(0.33 to 3.299 99) mA
(3 to 32.9999) mA
(33 to 329.999) mA
(0.33 to 1.099 99) A
(1.1 to 2.999 99) A
(3 to 10.9999) A
(11 to 20.5) A
54 nA
0.29 μA
2.8 μA
28 μA
0.2 mA
0.94 mA
4.7 mA
17 mA
Direct measurement:
Fluke 5520A
multifunction
calibrator
DC Voltage – Measure
3
Up to 100 mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
100 V to 1 kV
1.4 μV
7.9 μV
75 μV
1.1 mV
24 mV
Direct measurement:
Agilent 3458A, option
002, 8.5 digit
multimeter
DC Current – Measure3
(0 to 100) μA
100 μA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
4.1 nA
36 nA
0.37 μA
5.6 μA
0.15 mA
Direct measurement:
Agilent 3458A, option
002, 8.5 digit
multimeter
DC Resistance –
Generate
3
(0 to 10.9999) Ω
(11 to 32.9999) Ω
(33 to 109.9999) Ω
(110 to 329.9999) Ω
(330 to 1.099 999) kΩ
(1.1 to 3.299 999) kΩ
(3.3 to 10.999 99) kΩ
(11 to 32.999 99) kΩ
(33 to 109.9999) kΩ
(110 to 329.9999) kΩ
330 kΩ to 1.099 999 MΩ
1.2 mΩ
2 mΩ
2.9 mΩ
7.7 mΩ
25 mΩ
79 mΩ
0.25 Ω
0.79 Ω
2.5 Ω
8.8 Ω
30 Ω
Direct measurement:
Fluke 5520A
multifunction
calibrator | See scope document |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7815.01) Revised 05/29/2026 Page 3 of 11
Parameter/Equipment
Range
CMC2, 6 (±)
Comments5
DC Resistance –
Generate
3 (cont)
(1.1 to 3.299 999) MΩ
(3.3 to 10.999 99) MΩ
(11 to 32.9999) MΩ
(33 to 109.9999) MΩ
(110 to 329.9999) MΩ
(330 to 1100) MΩ
0.16 kΩ
1.1 kΩ
7.3 kΩ
45 kΩ
0.78 MΩ
13 MΩ
Direct measurement:
Fluke 5520A
multifunction
calibrator
DC Resistance –
Measure3
(0 to 10) Ω
(10 to 100) Ω
100 Ω to 1 kΩ
(1 to 10) kΩ
(10 to 100) kΩ
100 kΩ to 1 MΩ
(1 to 10) MΩ
(10 to 100) MΩ
0.25 mΩ
2.5 mΩ
14 mΩ
0.14 Ω
1.4 Ω
21 Ω
0.74 kΩ
62 kΩ
Direct measurement:
Agilent 3458A, option
002 8.5 digit
multimeter
Parameter/Range
Frequency
CMC2, 6 (±)
Comments5
AC Voltage – Generate
3
(1 to 33) mV
(33 to 330) mV
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
25 μV
9.1 μV
10 μV
31 μV
99 μV
0.24 mV
83 μV
44 μV
49 μV
97 μV
0.23 mV
0.57 mV
Direct measurement:
Fluke 5520A
multifunction
calibrator | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7815.01) Revised 05/29/2026 Page 4 of 11
Parameter/Range
Frequency
CMC2, 6 (±)
Comments5
AC Voltage – Generate
3
(cont)
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.81 mV
0.43 mV
0.54 mV
0.81 mV
1.9 mV
6.7 mV
8.2 mV
4.4 mV
6.7 mV
9.5 mV
24 mV
52 mV
57 mV
70 mV
87 mV
0.55 V
0.25 V
0.21 V
0.25 V
Direct measurement:
Fluke 5520A
multifunction
calibrator
AC Voltage – Measure
3
(1 to 10) mV
(10 to 100) mV
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
4.5 μV
16 μV
5.5 μV
60 μV
0.47 mV
12 μV
20 μV
52 μV
0.1 mV
0.36 mV
1.7 mV
Direct measurement:
Agilent 3458A, option
002, 8.5 digit
multimeter | ||
| 5 | - | AC Voltage; AC CurrentShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7815.01) Revised 05/29/2026 Page 5 of 11
Parameter/Range
Frequency
CMC2, 6 (±)
Comments5
AC Voltage – Measure
3
(cont)
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 700) V
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
40 Hz to 1 kHz
0.12 mV
0.19 mV
0.39 mV
0.97 mV
3.5 mV
12 mV
20 mV
1.4 mV
1.2 mV
2 mV
3.9 mV
9.6 mV
36 mV
26 mV
27 mV
44 mV
0.14 V
0.35 V
Direct measurement:
Agilent 3458A, option
002, 8.5 digit
multimeter
AC Current – Generate3
(29 to 330) μA
330 μA to 3.3 mA
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
0.6 μA
0.47 μA
0.4 μA
0.89 μA
2.2 μA
4.4 μA
5.3 μA
3.3 μA
2.7 μA
5.3 μA
13 μA
26 μA
Direct measurement:
Fluke 5520A
multifunction
calibrator | See scope document |
| 6 | - | AC CurrentShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7815.01) Revised 05/29/2026 Page 6 of 11
Parameter/Range
Frequency
CMC2, 6 (±)
Comments5
AC Current – Generate
3
(cont)
(3.3 to 33) mA
(33 to 330) mA
330 mA to 1.099 99 A
(1.1 to 2.999 99) A
(3 to 10.9999) A
(11 to 20.5) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
48 μA
25 μA
13 μA
23 μA
54 μA
0.11 mA
0.48 mA
0.25 mA
0.12 mA
0.3 mA
0.6 mA
1.2 mA
1.6 mA
0.52 mA
5.9 mA
25 mA
4.4 mA
1.7 mA
15 mA
62 mA
7.2 mA
10 mA
0.26 A
23 mA
28 mA
0.48 A
Direct measurement:
Fluke 5520A
multifunction
calibrator | See scope document |
| 7 | - | AC CurrentShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7815.01) Revised 05/29/2026 Page 7 of 11
Parameter/Range
Frequency
CMC2, 6 (±)
Comments5
AC Current – Measure
3
(0 to 100) μA
100 μA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
10 Hz to 20 Hz
20 Hz to 45 Hz
45 Hz to 100 Hz
100 Hz to 1 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
0.5 μA
0.21 μA
0.11 μA
0.11 μA
4.9 μA
2 μA
0.94 μA
0.59 μA
0.94 μA
5.1 μA
49 μA
20 μA
9.4 μA
5.9 μA
9.4 μA
51 μA
0.49 mA
0.2 mA
94 μA
59 μA
94 μA
0.51 mA
4.9 mA
2.1 mA
1.2 mA
1.4 mA
3.7 mA
Direct measurement:
Agilent 3458A, option
002, 8.5 digit
multimeter | - |
| 8 | - | thermocouple indicating devicesShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7815.01) Revised 05/29/2026 Page 8 of 11
Parameter/Equipment
Range
CMC2 (±)
Comments5
Electrical Stimulation of
Thermocouple
Indicating Devices –
Generate/Measure
3
Type E
Type J
Type K
Type S
Type T
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(0 to 250) °C
(250 to 1000) °C
(1000 to 1400) °C
(1400 to 1767) °C
(-250 to -150) °C
(150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.39 °C
0.13 °C
0.11 °C
0.13 °C
0.18 °C
0.21 °C
0.13 °C
0.11 °C
0.14 °C
0.18 °C
0.26 °C
0.14 °C
0.13 °C
0.21 °C
0.31 °C
0.37 °C
0.28 °C
0.29 °C
0.38 °C
0.49 °C
0.19 °C
0.13 °C
0.11 °C
Direct measurement:
Fluke 5520A
multifunction
calibrator
Parameter/Range
Frequency
CMC2, 6 (±)
Comments5
Capacitance – Generate
3
(0.4 to 3.299 99) nF
(3.3 to 32.9999) nF
(33 to 329.999) nF
(0.33 to 3.299 99) μF
(3.3 to 32.999) μF
10 Hz to 3 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
(10 to 300) Hz
(10 to 120) Hz
20 pF
0.14 nF
0.36 nF
8.3 nF
0.12 μF
Direct measurement:
Fluke 5520A
multifunction
calibrator | See scope document |
| 9 | - | Capacitance; OscilloscopesShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7815.01) Revised 05/29/2026 Page 9 of 11
Parameter/Range
Frequency
CMC2, 6 (±)
Comments5
Capacitance – Generate
3
(cont)
(33 to 329.999) μF
(0.33 to 3.299 99) mF
Up to 50 Hz
Up to 6 Hz
1.3 μF
13 μF
Direct measurement:
Fluke 5520A
multifunction
calibrator
Parameter/Equipment
Range
CMC2 (±)
Comments
Oscilloscopes
3
Amplitude DC Signal
50 Ω Load
Amplitude DC Signal
1 MΩ Load
Rise Time
Time Marker
50 Ω Load
Leveled Sinewave
Flatness into 50 Ω
(Relative to 50 kHz)
(1 to 24.999) mV
(25 to 109.99) mV
110 mV to 2.1999 V
(2.2 to 6.6) V
(1 to 24.999) mV
(25 to 109.99) mV
110 mV to 2.1999 V
(2.2 to 10.999) V
(11 to 130) V
(200 to 300) ps
1 kHz to 2 MHz
(200 to 350) ps
(2 to 10) MHz
(1 to 5) ns
10 ns
20 to 50) ns
100 ns to 20 ms
5 mVp-p to 5 Vp-p
50 kHz to 100 MHz
(100 to 300) MHz
300 to 600) MHz
5 mVp-p to 3.5 Vp-p
(600 to 1100) MHz
78 μV
0.24 mV
4.4 mV
13 mV
41 μV
74 μV
0.85 mV
4.3 mV
51 mV
0.23 ns
0.23 ns
9.7 fs
19 fs
97 fs
39 ns
9.8 mV/V + 11 mV
1.4 mV/V + 11 mV
29 mV/V + 12 mV
34 mV/V + 13 mV
Direct measurement:
Fluke 5522A/SC1100
multifunction
calibrator | - |
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7815.01) Revised 05/29/2026 Page 10 of 11
III. Mechanical
Parameter/Equipment
Range
CMC2, 6 (±)
Comments5
Hydraulic Gage Pressure –
Measure
3
(0 to 5) psi
(0 to 100) psi
(0 to 10 000) psi
0.0016 psi
0.033 psi
3 psi
Comparison to master
pressure gages:
Additel ADT681-02-
005
Additel ADT681-02-
100
Additel ADT681-02-
GP10k
IV. Thermodynamics
Parameter/Equipment
Range
CMC
2, 6 (±)
Comments5
Relative Humidity –
Measuring Equipment
(15 to 75) % RH
1.5 % RH
Comparison to Vaisala
M170/HMP77B
thermohygrometer
Temperature – Measuring
Equipment
3
22 °C
0.3 °C
Comparison to Vaisala
M170/HMP77B
thermohygrometer
V. Time & Frequency
Parameter/Equipment
Range
CMC2, 6 (±)
Comments5
Frequency – Measuring
Equipment
10 MHz
57 nHz/Hz
Comparison to Keysight
53132A, local reference
oscillator
Frequency – Measure
10 Hz to 225 MHz
> 225 MHz to 3 GHz
2 Hz
7.1 Hz
Direct measurement:
Keysight 53132A
universal counter | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7815.01) Revised 05/29/2026 Page 11 of 11
_______________________________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3
Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC
4 The uncertainty presented here does not include the resolution of the unit under test. The resolution will
be included in the reported measurement uncertainty at the time of calibration.
5 Unless otherwise specified in the far-right column above, the laboratory utilizes internally written
calibration procedures in the process of calibrating the parameters
6 The type of instrument or material being calibra ted is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
7 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 12 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in United States
- Element U.S. Space & DefenseFullerton, CA · ~4 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- RSA Industries Inc dba American GagePlacentia, CA · ~6 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- FLW Service CorporationHuntington Beach, CA · ~19 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- G.T. MICHELLI CO., LLC - SANTA FE SPRINGSSanta Fe Springs, CA · ~19 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Precision Granite USASanta Fe Springs, CA · ~19 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.