Anko Electronics

4091 E. LA Palma Ave Ste. N, 92807, Anaheim, CA, United States

Visit website
A2LA 7815.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
12
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 12 scope lines.

A2LA certificate 7815.01 · 12 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-to 12 in
2-DC Voltage; DC Current; DC Resistance
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7815.01) Revised 05/29/2026 Page 2 of 11 II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 6 (±) Comments5 DC Voltage – Generate 3 (0 to 329.999) mV (0 to 3.299 999) V (0 to 32.999 99) V (30 to 329.9999) V (0.1 to 1) kV 6.5 μV 33 μV 0.35 mV 4.9 mV 16 mV Direct measurement: Fluke 5520A multifunction calibrator DC Current – Generate3 (0 to 329.999) μA (0.33 to 3.299 99) mA (3 to 32.9999) mA (33 to 329.999) mA (0.33 to 1.099 99) A (1.1 to 2.999 99) A (3 to 10.9999) A (11 to 20.5) A 54 nA 0.29 μA 2.8 μA 28 μA 0.2 mA 0.94 mA 4.7 mA 17 mA Direct measurement: Fluke 5520A multifunction calibrator DC Voltage – Measure 3 Up to 100 mV 100 mV to 1 V (1 to 10) V (10 to 100) V 100 V to 1 kV 1.4 μV 7.9 μV 75 μV 1.1 mV 24 mV Direct measurement: Agilent 3458A, option 002, 8.5 digit multimeter DC Current – Measure3 (0 to 100) μA 100 μA to 1 mA (1 to 10) mA (10 to 100) mA 100 mA to 1 A 4.1 nA 36 nA 0.37 μA 5.6 μA 0.15 mA Direct measurement: Agilent 3458A, option 002, 8.5 digit multimeter DC Resistance – Generate 3 (0 to 10.9999) Ω (11 to 32.9999) Ω (33 to 109.9999) Ω (110 to 329.9999) Ω (330 to 1.099 999) kΩ (1.1 to 3.299 999) kΩ (3.3 to 10.999 99) kΩ (11 to 32.999 99) kΩ (33 to 109.9999) kΩ (110 to 329.9999) kΩ 330 kΩ to 1.099 999 MΩ 1.2 mΩ 2 mΩ 2.9 mΩ 7.7 mΩ 25 mΩ 79 mΩ 0.25 Ω 0.79 Ω 2.5 Ω 8.8 Ω 30 Ω Direct measurement: Fluke 5520A multifunction calibrator
See scope document
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7815.01) Revised 05/29/2026 Page 3 of 11 Parameter/Equipment Range CMC2, 6 (±) Comments5 DC Resistance – Generate 3 (cont) (1.1 to 3.299 999) MΩ (3.3 to 10.999 99) MΩ (11 to 32.9999) MΩ (33 to 109.9999) MΩ (110 to 329.9999) MΩ (330 to 1100) MΩ 0.16 kΩ 1.1 kΩ 7.3 kΩ 45 kΩ 0.78 MΩ 13 MΩ Direct measurement: Fluke 5520A multifunction calibrator DC Resistance – Measure3 (0 to 10) Ω (10 to 100) Ω 100 Ω to 1 kΩ (1 to 10) kΩ (10 to 100) kΩ 100 kΩ to 1 MΩ (1 to 10) MΩ (10 to 100) MΩ 0.25 mΩ 2.5 mΩ 14 mΩ 0.14 Ω 1.4 Ω 21 Ω 0.74 kΩ 62 kΩ Direct measurement: Agilent 3458A, option 002 8.5 digit multimeter Parameter/Range Frequency CMC2, 6 (±) Comments5 AC Voltage – Generate 3 (1 to 33) mV (33 to 330) mV (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz 25 μV 9.1 μV 10 μV 31 μV 99 μV 0.24 mV 83 μV 44 μV 49 μV 97 μV 0.23 mV 0.57 mV Direct measurement: Fluke 5520A multifunction calibrator
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7815.01) Revised 05/29/2026 Page 4 of 11 Parameter/Range Frequency CMC2, 6 (±) Comments5 AC Voltage – Generate 3 (cont) (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.81 mV 0.43 mV 0.54 mV 0.81 mV 1.9 mV 6.7 mV 8.2 mV 4.4 mV 6.7 mV 9.5 mV 24 mV 52 mV 57 mV 70 mV 87 mV 0.55 V 0.25 V 0.21 V 0.25 V Direct measurement: Fluke 5520A multifunction calibrator AC Voltage – Measure 3 (1 to 10) mV (10 to 100) mV 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz 4.5 μV 16 μV 5.5 μV 60 μV 0.47 mV 12 μV 20 μV 52 μV 0.1 mV 0.36 mV 1.7 mV Direct measurement: Agilent 3458A, option 002, 8.5 digit multimeter
5-AC Voltage; AC Current
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7815.01) Revised 05/29/2026 Page 5 of 11 Parameter/Range Frequency CMC2, 6 (±) Comments5 AC Voltage – Measure 3 (cont) 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 700) V 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 40 Hz to 1 kHz 0.12 mV 0.19 mV 0.39 mV 0.97 mV 3.5 mV 12 mV 20 mV 1.4 mV 1.2 mV 2 mV 3.9 mV 9.6 mV 36 mV 26 mV 27 mV 44 mV 0.14 V 0.35 V Direct measurement: Agilent 3458A, option 002, 8.5 digit multimeter AC Current – Generate3 (29 to 330) μA 330 μA to 3.3 mA (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 0.6 μA 0.47 μA 0.4 μA 0.89 μA 2.2 μA 4.4 μA 5.3 μA 3.3 μA 2.7 μA 5.3 μA 13 μA 26 μA Direct measurement: Fluke 5520A multifunction calibrator
See scope document
6-AC Current
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7815.01) Revised 05/29/2026 Page 6 of 11 Parameter/Range Frequency CMC2, 6 (±) Comments5 AC Current – Generate 3 (cont) (3.3 to 33) mA (33 to 330) mA 330 mA to 1.099 99 A (1.1 to 2.999 99) A (3 to 10.9999) A (11 to 20.5) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz 48 μA 25 μA 13 μA 23 μA 54 μA 0.11 mA 0.48 mA 0.25 mA 0.12 mA 0.3 mA 0.6 mA 1.2 mA 1.6 mA 0.52 mA 5.9 mA 25 mA 4.4 mA 1.7 mA 15 mA 62 mA 7.2 mA 10 mA 0.26 A 23 mA 28 mA 0.48 A Direct measurement: Fluke 5520A multifunction calibrator
See scope document
7-AC Current
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7815.01) Revised 05/29/2026 Page 7 of 11 Parameter/Range Frequency CMC2, 6 (±) Comments5 AC Current – Measure 3 (0 to 100) μA 100 μA to 1 mA (1 to 10) mA (10 to 100) mA 100 mA to 1 A 10 Hz to 20 Hz 20 Hz to 45 Hz 45 Hz to 100 Hz 100 Hz to 1 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz 0.5 μA 0.21 μA 0.11 μA 0.11 μA 4.9 μA 2 μA 0.94 μA 0.59 μA 0.94 μA 5.1 μA 49 μA 20 μA 9.4 μA 5.9 μA 9.4 μA 51 μA 0.49 mA 0.2 mA 94 μA 59 μA 94 μA 0.51 mA 4.9 mA 2.1 mA 1.2 mA 1.4 mA 3.7 mA Direct measurement: Agilent 3458A, option 002, 8.5 digit multimeter
-
8-thermocouple indicating devices
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7815.01) Revised 05/29/2026 Page 8 of 11 Parameter/Equipment Range CMC2 (±) Comments5 Electrical Stimulation of Thermocouple Indicating Devices – Generate/Measure 3 Type E Type J Type K Type S Type T (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (0 to 250) °C (250 to 1000) °C (1000 to 1400) °C (1400 to 1767) °C (-250 to -150) °C (150 to 0) °C (0 to 120) °C (120 to 400) °C 0.39 °C 0.13 °C 0.11 °C 0.13 °C 0.18 °C 0.21 °C 0.13 °C 0.11 °C 0.14 °C 0.18 °C 0.26 °C 0.14 °C 0.13 °C 0.21 °C 0.31 °C 0.37 °C 0.28 °C 0.29 °C 0.38 °C 0.49 °C 0.19 °C 0.13 °C 0.11 °C Direct measurement: Fluke 5520A multifunction calibrator Parameter/Range Frequency CMC2, 6 (±) Comments5 Capacitance – Generate 3 (0.4 to 3.299 99) nF (3.3 to 32.9999) nF (33 to 329.999) nF (0.33 to 3.299 99) μF (3.3 to 32.999) μF 10 Hz to 3 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz (10 to 300) Hz (10 to 120) Hz 20 pF 0.14 nF 0.36 nF 8.3 nF 0.12 μF Direct measurement: Fluke 5520A multifunction calibrator
See scope document
9-Capacitance; Oscilloscopes
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7815.01) Revised 05/29/2026 Page 9 of 11 Parameter/Range Frequency CMC2, 6 (±) Comments5 Capacitance – Generate 3 (cont) (33 to 329.999) μF (0.33 to 3.299 99) mF Up to 50 Hz Up to 6 Hz 1.3 μF 13 μF Direct measurement: Fluke 5520A multifunction calibrator Parameter/Equipment Range CMC2 (±) Comments Oscilloscopes 3 Amplitude DC Signal 50 Ω Load Amplitude DC Signal 1 MΩ Load Rise Time Time Marker 50 Ω Load Leveled Sinewave Flatness into 50 Ω (Relative to 50 kHz) (1 to 24.999) mV (25 to 109.99) mV 110 mV to 2.1999 V (2.2 to 6.6) V (1 to 24.999) mV (25 to 109.99) mV 110 mV to 2.1999 V (2.2 to 10.999) V (11 to 130) V (200 to 300) ps 1 kHz to 2 MHz (200 to 350) ps (2 to 10) MHz (1 to 5) ns 10 ns 20 to 50) ns 100 ns to 20 ms 5 mVp-p to 5 Vp-p 50 kHz to 100 MHz (100 to 300) MHz 300 to 600) MHz 5 mVp-p to 3.5 Vp-p (600 to 1100) MHz 78 μV 0.24 mV 4.4 mV 13 mV 41 μV 74 μV 0.85 mV 4.3 mV 51 mV 0.23 ns 0.23 ns 9.7 fs 19 fs 97 fs 39 ns 9.8 mV/V + 11 mV 1.4 mV/V + 11 mV 29 mV/V + 12 mV 34 mV/V + 13 mV Direct measurement: Fluke 5522A/SC1100 multifunction calibrator
-
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7815.01) Revised 05/29/2026 Page 10 of 11 III. Mechanical Parameter/Equipment Range CMC2, 6 (±) Comments5 Hydraulic Gage Pressure – Measure 3 (0 to 5) psi (0 to 100) psi (0 to 10 000) psi 0.0016 psi 0.033 psi 3 psi Comparison to master pressure gages: Additel ADT681-02- 005 Additel ADT681-02- 100 Additel ADT681-02- GP10k IV. Thermodynamics Parameter/Equipment Range CMC 2, 6 (±) Comments5 Relative Humidity – Measuring Equipment (15 to 75) % RH 1.5 % RH Comparison to Vaisala M170/HMP77B thermohygrometer Temperature – Measuring Equipment 3 22 °C 0.3 °C Comparison to Vaisala M170/HMP77B thermohygrometer V. Time & Frequency Parameter/Equipment Range CMC2, 6 (±) Comments5 Frequency – Measuring Equipment 10 MHz 57 nHz/Hz Comparison to Keysight 53132A, local reference oscillator Frequency – Measure 10 Hz to 225 MHz > 225 MHz to 3 GHz 2 Hz 7.1 Hz Direct measurement: Keysight 53132A universal counter
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7815.01) Revised 05/29/2026 Page 11 of 11 _______________________________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC 4 The uncertainty presented here does not include the resolution of the unit under test. The resolution will be included in the reported measurement uncertainty at the time of calibration. 5 Unless otherwise specified in the far-right column above, the laboratory utilizes internally written calibration procedures in the process of calibrating the parameters 6 The type of instrument or material being calibra ted is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 7 This scope meets A2LA’s P112 Flexible Scope Policy.
12ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

4091 E. LA Palma Ave Ste. N, Anaheim, CA, 92807, US

33.83475, -117.91173

Open in Maps

Other Locations

1 other site in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.