RSA Industries Inc dba American Gage
1131 Richfield Rd, 92870, Placentia, CA, United States
Visit website- Scope lines
- 26
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 26 scope lines.
A2LA certificate 4296.01 · 26 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4296.01) 03/27/2025 Page 2 of 25
Parameter/Equipment
Range
CMC2, 4, 9 (±)
Comments
Indicators3
Up to 1 in
Up to 2 in
Up to 10 in
46 µin
92 µin
590 µin
Gage blocks
Indicator – Amplifier
Up to 0.002 in
3 µin
Gage blocks
Gage Block
Comparators3
Up to 0.0003 in
Up to 0.001 in
2 µin
2.5 µin
Gage blocks
Master Comparators –
Meter3
Up to 0.0002 in
Up to 0.0004 in
Up to 0.002 in
Up to 0.004 in
Up to 0.02 in
3.6 µin
6.2 µin
29 µin
58 µin
290 µin
Gage blocks
Height Master3
Parallelism of Steps
Micrometer Linearity
Step Height
Up to 0.001 in
Up to 1 in
Up to 4 in
(4 to 24) in
15 µin
(17 + 6.9L) µin
(19 + 6.9L) µin
(25 + 6.9L) µin
Gage blocks & amplifier
Gage blocks
Length
Parallelism
Flatness
(0.01 to 4) in
(5 to 20) in
(0.01 to 20) in
(0.01 to 20) in
(3.3 + 1.8L)
µin
(2.4 + 2.7L) µin
1.2 µin
3.2 µin
Gage blocks &
comparator
Optical flat
Length Standards –
Measure5
Up to 72 in
(120 + 6.6L) µin
Using gage blocks &
amplifier
Ring Gages
(0.04 to 1) in
(> 1 to 12) in
10 µin
(7 + 3D) µin
Master comparator,
gage blocks | ||
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4296.01) 03/27/2025 Page 3 of 25
Parameter/Equipment
Range
CMC2, 4, 9 (±)
Comments
2D Length – Measure5
Light Probe
High – Precision
Wide – Field
Up to 3.54 in
Up to 4.92 in
Up to 7.87 in
(320 + 7L) µin
(79 + 6.9L) µin
(200 + 6.9L) µin
Using Keyence IM-7020
vision system
Dimensional Measuring
Systems
3
0.02 in
0.1 in
0.1 in
0.2 in
0.8 in
13 µin + 0.58R
17 µin + 0.58R
6.4 µin + 0.58R
7 µin + 0.58R
23 µin + 0.58R
Master gages
Steel pin gage
Ceramic pin gage
Ceramic gage block
Ceramic gage block
Ceramic ring gage
Thread Plug Gages (60°) –
Pitch Diameter
Major Diameter
(0.06 to 1) in
(> 1 to 6) in
(0.06 to 1) in
(> 1 to 6) in
(58 + 11D) µin
(60 + 9D) µin
20 µin
(18 + 2D) µin
P&W
Supermicrometer
TM,
thread wires, gage
blocks
P&W SupermicrometerTM3 –
Spindle
Meter
Force
1 in
0.001 in
(2 to 16) ozf
(16 to 40) ozf
15 µin
10 µin
0.56 ozf
2.9 ozf
Gage blocks
Force gage
Plug Gages
Up to 1 in
(> 1 to 12) in
20 µin
(18 + 2D) µin
P&W
Supermicrometer
TM,
gage blocks, universal
comparator
Adjustable Thread Ring
Gages (60°) – Pitch
Diameter
3
Up to 6 in
(W) Set Plug
Tolerance
Comparison to thread
set plugs; tolerance of
set plug is the stated
CMC | to 3.54 in |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4296.01) 03/27/2025 Page 4 of 25
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 4, 7 (±)
Comments
DC Voltage3 – Generate
(0 to 220) mV
(0.22 to 2.2) V
(2.2 to 11) V
(11 to 22) V
(22 to 220) V
(220 to 1100) V
7.5 µV/V + 0.4 µV
5 µV/V + 0.7 µV
3.5 µV/V + 2.9 µV
3.5 µV/V + 4.3 µV
5 µV/V + 43 µV
6.5 µV/V + 440 µV
Fluke 5720A
DC Voltage3 – Generate
(0 to 330) mV
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1000) V
16 µV/V + 0.78 µV
9 µV/V + 1.6 µV
9 µV/V + 16 µV
14 µV/V + 120 µV
14 µV/V + 1.4 mV
Fluke 5522A
DC Voltage3 – Measure
(0 to 200) mV
(0.2 to 2) V
(2 to 20) V
(20 to 200) V
(200 to 1050) V
(0 to 10) kV
4.5 µV/V + 0.1 µV
3 µV/V + 0.42 µV
3 µV/V + 4.7 µV
4.5 µV/V + 43 µV
4.5 µV/V + 560 µV
0.36 % + 0.038 V
Fluke 8508A
Vitrek 4700
DC Current3 – Generate
(0 to 220) µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
(2.2 to 11) A
40 µA/A + 6 nA
35 µA/A + 7 nA
35 µA/A + 40 nA
45 µA/A + 0.7 µA
80 µA/A + 12 µA
360 µA/A + 480 µA
Fluke 5720A/5725A
DC Current3 – Generate
(0 to 330) µA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 1.1) A
(1.1 to 3) A
(3 to 11) A
(11 to 20.5) A
(20 to 100) A
(100 to 300) A
120 µA/A + 0.016 µA
78 µA/A + 0.039 µA
78 µA/A + 0.19 µA
78 µA/A + 1.9 µA
160 µA/A + 31 µA
300 µA/A + 31 µA
390 µA/A + 390 µA
1 mA/A + 580 µA
0.058 % + 0.58R
0.12 % + 0.58R
Fluke 5522A
Guildline 9711, Fluke
8508A, & power
supplies | ||
| 5 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4296.01) 03/27/2025 Page 5 of 25
Parameter/Equipment
Range
CMC2, 4, 7 (±)
Comments
DC Current3 – Measure
(0 to 200) µA
(0.2 to 2) mA
(2 to 20) mA
(20 to 200) mA
(0.2 to 2) A
(2 to 20) A
(20 to 100) A
(100 to 300) A
12 µA/A + 0.41 nA
12 µA/A + 4 nA
13 µA/A + 40 nA
36 µA/A + 0.84 µA
170 µA/A + 16 µA
380 µA/A + 400 µA
0.058 % + 0.58R
0.12 % + 0.58R
Fluke 8508A
Guildline 9711, Fluke
8508A
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Voltage3 – Generate
Up to 22 mV
(22 to 220) mV
(0.22 to 2.2) V
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
240 µV/V + 4 µV
90 µV/V + 4 µV
80 µV/V + 4 µV
200 µV/V + 5 µV
500 µV/V + 5 µV
1.1 mV/V + 10 µV
1.4 mV/V + 20 µV
2.7 mV/V + 20 µV
240 µV/V + 12 µV
90 µV/V + 7 µV
80 µV/V + 7 µV
200 µV/V + 7 µV
460 µV/V + 17 µV
900 µV/V + 20 µV
1.4 mV/V + 25 µV
2.7 mV/V + 45 µV
240 µV/V + 41 µV
90 µV/V + 16 µV
45 µV/V + 9 µV
75 µV/V + 10 µV
110 µV/V + 30 µV
420 µV/V + 80 µV
0.1 mV/V + 200 µV
1.7 mV/V + 310 µV
Fluke 5720A/5725A | to 20 A |
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4296.01) 03/27/2025 Page 6 of 25
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Voltage3 –
Generate (cont)
(2.2 to 22) V
(22 to 220) V
(220 to 250) V
(220 to 750) V
(220 to 1100) V
(1 to 33) mV
(33 to 330) mV
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(15 to 50) Hz
(0.05 to 1) kHz
(30 to 50) kHz
(50 to 100) kHz
(0.04 to 1) kHz
(1 to 20) kHz
(20 to 30) kHz
(10 to 45) Hz
(0.045 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
(0.045 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
240 µV/V + 400 µV
90 µV/V + 150 µV
45 µV/V + 150 µV
75 µV/V + 100 µV
100 µV/V + 200 µV
270 µV/V + 600 µV
1 mV/V + 2 mV
1.5 mV/V + 3.2 mV
240 µV/V + 4 mV
90 µV/V + 2 mV
52 µV/V + 0.7 mV
80 µV/V + 1 mV
150 µV/V + 2.5 mV
900 µV/V + 16 mV
4.4 mV/V + 40 mV
8 mV/V + 80 mV
300 µV/V + 16 mV
70 µV/V + 4 mV
600 µV/V + 12 mV
2.3 mV/V + 45 mV
90 µV/V + 5 mV
170 µV/V + 7.2 mV
600 µV/V + 11 mV
620 µV/V + 4.8 µV
120 µV/V + 4.7 µV
160 µV/V + 4.7 µV
0.78 mV/V + 4.7 µV
2.7 mV/V + 9.3 µV
6.2 mV/V + 39 µV
230 µV/V + 6.2 µV
110 µV/V + 6.2 µV
120 µV/V + 6.2 µV
270 µV/V + 6.3 µV
620 µV/V + 25 µV
1.6 mV/V + 54 µV
Fluke 5720A/5725A
Max voltage is subject
to 2.2 x 10e7 V-Hz | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4296.01) 03/27/2025 Page 7 of 25
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Voltage3 – Generate
(cont)
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
(10 to 45) Hz
(0.045 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
(0.045 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(0.045 to 1) kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(0.045 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
230 µV/V + 39 µV
120 µV/V + 47 µV
150 µV/V + 47 µV
230 µV/V + 40 µV
540 µV/V + 97 µV
1.9 mV/V + 470 µV
230 µV/V + 510 µV
120 µV/V + 470 µV
190 µV/V + 470 µV
270 µV/V + 470 µV
700 µV/V + 1.2 mV
150 µV/V + 4.8 mV
160 µV/V + 4.7 mV
190 µV/V + 4.7 mV
230 µV/V + 4.7 mV
1.6 mV/V + 39 mV
230 µV/V + 9.5 mV
190 µV/V + 8.2 mV
230 µV/V + 8.8 mV
Fluke 5522A
AC Voltage3 – Measure
Up to 200 mV
(0.2 to 2) V
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
(0.1 to 2) kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
(0.1 to 2) kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
160 µV/V + 14 µV
130 µV/V + 4 µV
110 µV/V + 4 µV
110 µV/V + 2 µV
110 µV/V + 4 µV
310 µV/V + 8 µV
710 µV/V + 20 µV
140 µV/V + 120 µV
110 µV/V + 21 µV
85 µV/V + 20 µV
65 µV/V + 20 µV
85 µV/V + 20 µV
210 µV/V + 40 µV
510 µV/V + 200 µV
0.3 % + 2 mV
1 % + 20 mV
Fluke 8508A | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4296.01) 03/27/2025 Page 8 of 25
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Voltage3 – Measure
(cont)
(2 to 20) V
(20 to 200) V
(200 to 1050) V
(0 to 10) kV
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
(0.1 to 2) kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
(0.1 to 2) kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 10) Hz
(10 to 40) Hz
(0.04 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(0.1 to 200) Hz
(200 to 450) Hz
(450 to 600) Hz
140 µV/V + 1.2 mV
110 µV/V + 0.2 mV
85 µV/V + 0.2 mV
65 µV/V + 0.2 mV
85 µV/V + 0.2 mV
210 µV/V + 0.4 mV
510 µV/V + 2 mV
0.3 % + 20 mV
1 % + 200 mV
140 µV/V + 12 mV
110 µV/V + 2 mV
85 µV/V + 2 mV
65 µV/V + 2 mV
85 µV/V + 2 mV
210 µV/V + 4 mV
510 µV/V + 20 mV
0.3 % + 200 mV
1 % + 2 V
140 µV/V + 70 mV
110 µV/V + 20 mV
95 µV/V + 20 mV
210 µV/V + 40 mV
510 µV/V + 200 mV
0.14 % + 0.12 V
0.46 % + 0.12 V
0.87 % + 0.12 V
Fluke 8508A
Vitrek 4700
AC Current3 – Generate
Up to 220 µA
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
250 µA/A + 17 nA
160 µA/A + 10 nA
120 µA/A + 8 nA
280 µA/A + 12 nA
1.1 mA/A + 65 nA
Fluke 5720A/5725A | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4296.01) 03/27/2025 Page 9 of 25
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Current3 – Generate
(cont)
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
(2.2 to 11) A
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(0.02 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(0.04 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
250 µA/A + 42 nA
160 µA/A + 36 nA
120 µA/A + 35 nA
200 µA/A + 110 nA
1.1 mA/A + 650 nA
250 µA/A + 410 nA
160 µA/A + 360 nA
120 µA/A + 350 nA
200 µA/A + 550 nA
1.1 mA/A + 5 µA
250 µA/A + 4.7 µA
160 µA/A + 3.6 µA
120 µA/A + 2.5 µA
200 µA/A + 3.5 µA
1.1 mA/A + 10 µA
260 µA/A + 35 µA
450 µA/A + 80 µA
7 mA/A + 160 µA
460 µA/A + 180 µA
950 µA/A + 390 µA
3.6 mA/A + 750 µA
Fluke 5720A/5725A
AC Current3 – Generate
(29 to 330) µA
(0.33 to 3.3) mA
(10 to 20) Hz
(20 to 45) Hz
(0.045 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
(0.045 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
0.16 % + 0.078 µA
0.12 % + 0.078 µA
0.097 % + 0.078 µA
0.23 % + 0.12 µA
0.62 % + 0.16 µA
1.2 % + 0.31 µA
0.16 % + 0.12 µA
0.097 % + 0.12 µA
0.078 % + 0.12 µA
0.16 % + 0.16 µA
0.39 % + 0.23 µA
0.78 % + 0.47 µA
Fluke 5522A | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4296.01) 03/27/2025 Page 10 of 25
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Current3 – Generate
(cont)
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 3) A
(3 to 11) A
(11 to 20.5) A
(10 to 20) Hz
(20 to 45) Hz
(0.045 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
(0.045 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
(0.045 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
(0.1 to 1) kHz
(1 to 5) kHz
(45 to 100) Hz
(0.1 to 1) kHz
(1 to 5) kHz
0.14 % + 1.6 µA
0.07 % + 1.6 µA
0.031 % + 1.6 µA
0.062 % + 1.6 µA
0.16 % + 2.3 µA
0.31 % + 3.1 µA
0.14 % + 16 µA
0.07 % + 16 µA
0.031 % + 16 µA
0.078 % + 39 µA
0.16 % + 78 µA
0.31 % + 160 µA
0.14 % + 78 µA
0.047 % + 78 µA
0.47 % + 0.78 mA
1.9 % + 3.9 mA
0.047 % + 1.6 mA
0.078 % + 1.6 mA
2.3 % + 1.6 mA
0.093 % + 3.9 mA
0.12 % + 3.9 mA
2.3 % + 3.9 mA
Fluke 5522A
AC Current3 – Measure
Up to 200 µA
(0.2 to 2) mA
(1 to 10) Hz
(0.01 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
(0.01 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
480 µA/A + 0.021 µA
480 µA/A + 0.02 µA
650 µA/A + 0.02 µA
0.4 % + 0.02 µA
290 µA/A + 0.2 µA
280 µA/A + 0.2 µA
650 µA/A + 0.2 µA
0.4 % + 0.2 µA
Fluke 8508A | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4296.01) 03/27/2025 Page 11 of 25
Parameter/Range
Frequency
CMC2, 4, 7 (±)
Comments
AC Current3 – Measure
(cont)
(2 to 20) mA
(20 to 200) mA
(0.2 to 2) A
(2 to 20) A
(20 to 100) A
(1 to 10) Hz
(0.01 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
(0.01 to 10) kHz
(10 to 30) kHz
(0.01 to 2) kHz
(2 to 10) kHz
(10 to 30) kHz
(0.01 to 2) kHz
(2 to 10) kHz
(0.1 to 1000) Hz
290 µA/A + 2 µA
280 µA/A + 2 µA
650 µA/A + 2 µA
0.4 % + 2 µA
290 µA/A + 20 µA
250 µA/A + 20 µA
600 µA/A + 20 µA
600 µA/A + 200 µA
710 µA/A + 200 µA
0.3 % + 200 µA
800 µA/A + 2 mA
0.25 % + 2 mA
0.13 A + 0.58R
Fluke 8508A
Valhalla 2575A &
8508A
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Resistance3 – Measure
(0 to 2) Ω
(2 to 20) Ω
(20 to 200) Ω
(0.2 to 2) kΩ
(2 to 20) kΩ
(20 to 200) kΩ
(0.2 to 2) MΩ
(2 to 20) MΩ
(20 to 200) MΩ
(0.2 to 2) GΩ
(2 to 20) GΩ
15 µΩ/Ω + 4 µΩ
9 µΩ/Ω + 14 µΩ
7.5 µΩ/Ω + 51 µΩ
7.5 µΩ/Ω + 510 µΩ
7.5 µΩ/Ω + 5 mΩ
7.5 µΩ/Ω + 52 mΩ
8.5 µΩ/Ω + 530 mΩ
15 µΩ/Ω + 10 Ω
60 µΩ/Ω + 100 Ω
530 µΩ/Ω + 1 kΩ
530 µΩ/Ω + 10 kΩ
Fluke 8508A
Resistance3 – Generate
(100 to 1000) MΩ
(1 to 10) GΩ
(10 to 100) GΩ
(100 to 1000) GΩ
(1 to 11.111) TΩ
220 µΩ/Ω
680 µΩ/Ω
3.7 mΩ/Ω
4 mΩ/Ω
15 mΩ/Ω
HRRS-10kV | ||
| 12 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4296.01) 03/27/2025 Page 12 of 25
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Resistance3 – Generate (cont)
Fixed Points
(1, 1.9) Ω
(10, 19) Ω
(100, 190) Ω
(1, 1.9) kΩ
(10, 19) kΩ
(100, 190) kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
95 µΩ/Ω + 0.2 µΩ
23 µΩ/Ω + 1.5 µΩ
10 µΩ/Ω + 11 µΩ
9 µΩ/Ω + 120 µΩ
9 µΩ/Ω + 1.5 mΩ
11 µΩ/Ω + 15 mΩ
20 µΩ/Ω + 180 mΩ
21 µΩ/Ω + 140 mΩ
40 µΩ/Ω + 580 mΩ
47 µΩ/Ω + 1.1 Ω
100 µΩ/Ω + 15 Ω
Fluke 5720A
Resistance3 – Generate
(0 to 11) Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
(0.33 to 1.1) kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
(0.33 to 1.1) MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
(330 to 1100) MΩ
31 µΩ/Ω + 0.78 mΩ
23 µΩ/Ω + 1.2 mΩ
22 µΩ/Ω + 1.1 mΩ
22 µΩ/Ω + 1.6 mΩ
22 µΩ/Ω + 2.2 mΩ
22 µΩ/Ω + 16 mΩ
22 µΩ/Ω + 16 mΩ
22 µΩ/Ω + 160 mΩ
22 µΩ/Ω + 160 mΩ
25 µΩ/Ω + 1.6 Ω
25 µΩ/Ω + 1.7 Ω
47 µΩ/Ω + 24 Ω
100 µΩ/Ω + 39 Ω
200 µΩ/Ω + 2 kΩ
390 µΩ/Ω + 2 kΩ
2.3 mΩ/Ω + 78 kΩ
12 mΩ/Ω + 390 kΩ
Fluke 5522A
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
Capacitance3 – Generate
(0.19 to 1.1) nF
(1.1 to 3.3) nF
(3.3 to 11) nF
(11 to 110) nF
(110 to 330) nF
(0.33 to 1.1) µF
(1.1 to 3.3) µF
10 Hz to 10 kHz
10 Hz to 3 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
(10 to 600) Hz
(10 to 300) Hz
0.39 % + 0.0081 nF
0.39 % + 0.0078 nF
0.19 % + 0.0078 nF
0.19 % + 0.078 nF
0.19 % + 0.23 nF
0.19 % + 0.83 nF
0.19 % + 2.3 nF
Fluke 5522A
*Excludes 0.7 mF | to 1100 MΩ |
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4296.01) 03/27/2025 Page 13 of 25
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
Capacitance3 – Generate (cont)
(3.3 to 11) µF
(11 to 33) µF
(33 to 110) µF
(110 to 330) µF
(0.33 to 1.1) mF
(1.1 to 3.3) mF
(3.3 to 11) mF
(11 to 33) mF
(33 to 110) mF
(10 to 150) Hz
(10 to 120) Hz
(10 to 80) Hz
(0 to 50) Hz
(0 to 20) Hz
(0 to 6) Hz
(0 to 2) Hz
(0 to 0.6) Hz
(0 to 0.2) Hz
0.19 % + 7.8 nF
0.31 % + 23 nF
0.35 % + 78 nF
0.35 % + 230 nF
0.35 % + 0.78 µF
0.35 % + 2.3 µF
0.35 % + 12 µF
0.58 % + 23 µF
0.85 % + 82 µF
Fluke 5522A
*Excludes 0.7 mF
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Simulation of
Thermocouple Indicators &
Indicating Systems
3 –
Type E
Type J
Type K
Type T
(-270 to -245) °C
(-245 to -195) °C
(-195 to -155) °C
(-155 to -90) °C
(-90 to 15) °C
(15 to 890) °C
(890 to 1000) °C
(-210 to -180) °C
(-180 to -120) °C
(-120 to -50) °C
(-50 to 990) °C
(990 to 1200) °C
(-270 to -255) °C
(-255 to -195) °C
(-195 to -115) °C
(-115 to -55) °C
(-55 to 1000) °C
(-270 to -255) °C
(-255 to -240) °C
(-240 to -210) °C
(-210 to -150) °C
(-150 to -40) °C
(-40 to 100) °C
(100 to 400) °C
1.4 °C
0.21 °C
0.12 °C
0.097 °C
0.083 °C
0.071 °C
0.082 °C
0.14 °C
0.12 °C
0.094 °C
0.083 °C
0.082 °C
2.5 °C
0.81 °C
0.14 °C
0.11 °C
0.087 °C
2.1 °C
0.57 °C
0.35 °C
0.21 °C
0.14 °C
0.094 °C
0.083 °C
Ectron Corporation
1140A | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4296.01) 03/27/2025 Page 14 of 25
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Simulation of RTD
Indicators3
Pt 385, 100 Ω:
( -200 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
Pt 385, 200 Ω:
( -200 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
Pt 385, 500 Ω:
(-200 to -80) °C
(-80 to 100) °C
(100 to 260) °C
(260 to 400) °C
(400 to 600) °C
(600 to 630) °C
Pt 385, 1000 Ω:
(-200 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 600) °C
(600 to 630) °C
Pt 3916, 100 Ω :
(-200 to -190) °C
(-190 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
Pt 3926, 100 Ω:
(-200 to -0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
0.051 °C
0.071 °C
0.092 °C
0.10 °C
0.12 °C
0.23 °C
0.041 °C
0.051 °C
0.12 °C
0.13 °C
0.14 °C
0.16 °C
0.041 °C
0.051 °C
0.061 °C
0.082 °C
0.092 °C
0.11 °C
0.031 °C
0.041 °C
0.051 °C
0.061 °C
0.071 °C
0.23 °C
0.26 °C
0.041 °C
0.051 °C
0.061 °C
0.071 °C
0.082 °C
0.092 °C
0.10 °C
0.23 °C
0.051 °C
0.071 °C
0.092 °C
0.10 °C
0.12 °C
Fluke 5522A | ||
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4296.01) 03/27/2025 Page 15 of 25
Parameter
Range
CMC2, 4, 6, 7 (±)
Comments
Electrical Simulation of RTD
Indicators3 (cont)
PtNi 385, 120 Ω:
(-80 to 100) °C
(100 to 260) °C
Cu 427, 10 Ω:
(-100 to 260) °C
0.082 °C
0.14 °C
0.31 °C
Fluke 5522A
Waveform – Measure3
Voltage
Frequency
Rise Time
(0 to 100) V
Up to 500 MHz
Up to 500 MHz
0.12 % + 0.82R
0.24 % + 0.82R
0.81 ns + 0.82R
Tektronix TDS3054B
Oscilloscopes3 –
DC Voltage:
50 Ω
1 MΩ
Square Wave Voltage:
10 Hz to 10 kHz (50 Ω)
10 Hz to 1 kHz (1 MΩ)
(1 to 10) kHz (1 MΩ)
Square Wave Frequency
Rise Time – Generate:
1 kHz to 2 MHz
(2 to 10) MHz
Time Marker, 50 Ω
Pulse Width
Square, Sine, & Triangle
Waveforms:
10 Hz to 100 kHz:
1 MΩ
50 Ω
(0 to 6) V
(0 to 130) V
1 mVp-p to 6 Vp-p
1 mVp-p to 130 Vp-
p
1 mVp-p to 130 Vp-
p
10 Hz to 10 kHz
≤ 300 ps
< 350 ps
5 s to 20 ms
20 ms to 1 ns
(4 to 500) ns
20 ms to 200 ns
1.8 mV to 55 Vp-p
1.8 mV to 2.5 Vp-p
0.19 % + 31 µV
0.039 % + 40 µV
0.19 % + 69 µV
0.078 % + 130 µV
0.19 % + 130 µV
1.9 µHz/Hz + 0.58R
78 ps
78 ps
(25 + 1000t) µs/s
1.9 µs/s + 0.0031 ns
3.9 % + 2 ns
1.9 µs/s + 0.18 ns
2.3 % + 150 µV
2.3 % + 78 µV
Fluke 5522A
t = time in seconds | ||
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4296.01) 03/27/2025 Page 16 of 25
Parameter
Range
CMC2, 6 (±)
Comments
Oscilloscopes3 – (cont)
Level Sine Wave:
5 mV to 5.5 V
4 mV to 3.5 V
Flatness Relative to 50 kHz
Frequency
50 kHz to 10 MHz
(10 to 100) MHz
(100 to 300) MHz
(300 to 600) MHz
(600 to 1100) MHz
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
(600 to 1100) MHz
50 kHz to 1100 MHz
1.6 % + 240 µV
2.7 % + 240 µV
3.1 % + 240 µV
4.7 % + 240 µV
5.4 % + 240 µV
1.2 % + 97 µV
1.6 % + 97 µV
3.1 % + 97 µV
3.9 % + 97 µV
1.9 µHz/Hz + 550 µHz
Fluke 5522A
III. RF/Microwave
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
RF Power3 – Measure
(-50 to 30) dBm
(-35 to 20) dBm
(-35 to 20) dBm
9 kHz to 13 GHz
(13 to 18) GHz
10 MHz to 18 GHz
(18 to 26.5) GHz
(26.5 to 33) GHz
50 MHz to 18 GHz
(18 to 26.5) GHz
(26.5 to 33) GHz
(33 to 50) GHz
0.080dBm
0.091 dBm
0.086 dBm
0.12 dBm
0.14 dBm
0.087 dBm
0.11 dBm
0.13 dBm
0.17 dBm
E4419B & E9304A
E4419B & N8485A
033
E4419B & N8487A
RF Power3 – Generate
( -110 to -10) dBm
(-10 to 10) dBm
50 MHz to 20 GHz
(20 to 26.5) GHz
(20 to <40) GHz
(40 to 50) GHz
50 MHz to 18 GHz
(18 to 26.5) GHz
(26.5 to 50) GHz
0.38 dBm
0.45 dBm
0.50 dBm
0.82 dBm
0.11 dBm
0.14 dBm
0.20 dBm
83650B signal
generator | ||
| 17 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4296.01) 03/27/2025 Page 17 of 25
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Tuned RF – Measure3
100 kHz to 26.5 GHz
100 kHz to 3.05 GHz
(3.05 to 6.6) GHz
(6.6 to 13.2) GHz
(13.2 to 19.2) GHz
(19.2 to 26.5) GHz
(+10 to 0) dBm
(0 to -10) dBm
(-10 to -20) dBm
(-20 to -30) dBm
(-30 to -40) dBm
(-40 to -50) dBm
(-50 to -60) dBm
(-60 to -70) dBm
(-70 to -80) dBm
(-80 to -90) dBm
(-90 to -100) dBm
(-100 to -110) dBm
(-110 to -120) dBm
(-120 to -130) dBm
(-70 to -80) dBm
(-80 to -90) dBm
(-90 to -100) dBm
(-100 to -110) dBm
(-110 to -120) dBm
(-120 to -126) dBm
(-70 to -80) dBm
(-80 to -90) dBm
(-90 to -100) dBm
(-100 to -110) dBm
(-110 to -117) dBm
(-70 to -80) dBm
(-80 to -90) dBm
(-90 to -100) dBm
(-100 to -10) dBm
(-70 to -80) dBm
(-80 to -90) dBm
(-90 to -100) dBm
(-100 to -102) dBm
0.024 dB
0.018 dB
0.024 dB
0.029 dB
0.035 dB
0.041 dB
0.053 dB
0.069 dB
0.074 dB
0.10 dB
0.11 dB
0.24 dB
0.66 dB
1.4 dB
0.074 dB
0.10 dB
0.12 dB
0.37 dB
0.91 dB
1.4 dB
0.074 dB
0.11 dB
0.32 dB
0.83 dB
1.4 dB
0.075 dB
0.25 dB
0.70 dB
1.4 dB
0.17 dB
0.53 dB
1.2 dB
1.4 dB
E4440 Opt. 233 | 100000 to 26500000000 Hz |
| 18 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4296.01) 03/27/2025 Page 18 of 25
Parameter/Equipment
Frequency
CMC2, 6, 7 (±)
Comments
Flatness3
Reference 100 kHz
Reference 10 MHz
Reference 50 MHz
Reference 1 GHz
Reference 10 MHz
Reference 50 MHz
Reference 1 GHz
Reference 50 MHz
Reference 1 GHz
9 kHz to 12.4 GHz
(12.4 to 18) GHz
9 kHz to 12.4 GHz
(12.4 to 18) GHz
9 kHz to 12.4 GHz
(12.4 to 18) GHz
9 kHz to 12.4 GHz
(12.4 to 18 GHz
10 MHz to 18 GHz
(18 to 26.5) GHz
(26.5 to 33) GHz
10 MHz to 18 GHz
(18 to 26.5) GHz
(26.5 to 33) GHz
10 MHz to 18 GHz
(18 to 26.5) GHz
(26.5 to 33) GHz
10 MHz to 18 GHz
(18 to 33) GHz
(33 to 50) GHz
10 MHz to 18 GHz
(18 to 33) GHz
(33 to 50) GHz
0.031 dB
0.046 dB
0.031 dB
0.040 dB
0.030 dB
0.046 dB
0.030 dB
0.040 dB
0.068 dB
0.079 dB
0.097 dB
0.062 dB
0.079 dB
0.097 dB
0.062 dB
0.081 dB
0.099 dB
0.057 dB
0.082 dB
0.12 dB
0.057 dB
0.083 dB
0.13 dB
E4419B & E9304A
E4419B & N8485A-
33
E4419B & N8487A
Power Sensor Calibration
Factors
9 kHz to 8 GHz
(8 to 14) GHz
(14 to 17) GHz
(17 to 18) GHz
(1 to 8) GHz
(9 to 13) GHz
10 MHz to 18 GHz
(18 to 24) GHz
(24 to 26.5) GHz
(26.5 to 33) GHz
1.1 %
1.2 %
1.3 %
1.5 %
1.4 %
1.6 %
1.7 %
2.1 %
2.2 %
2.6 %
E4419B & E9304A
E4419B & N8485A-
33 | ||
| 19 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4296.01) 03/27/2025 Page 19 of 25
Parameter/Equipment
Range
CMC2, 6, 7 (±)
Comments
Power Sensor Calibration
Factors (cont)
100 MHz to 2 GHz
(2 to 12.4) GHz
50 MHz to 18 GHz
(18 to 26.5) GHz
(26.5 to 33) GHz
(33 to 38) GHz
(38 to 50) GHz
1.4 %
1.5 %
1.7 %
1.9 %
2.0 %
2.6 %
3.0 %
E4419B &
N8487A
Amplitude Modulation3 –
Measure
CW:
100 kHz to 10 MHz
10 MHz to 3 GHz
(3 to 26.5) GHz
50 Hz to 10 kHz
(5 to 99) % Depth
50 Hz to 100 kHz
(5 to 20) % Depth
(20 to 99) % Depth
50 Hz to 100 kHz
(5 to 20) % Depth
(20 to 99) % Depth
0.68% IV + 0.25 % AM
1.7 % IV + 0.39 % AM
0.41 % IV + 0.39 % AM
4.1 % IV + 0.32 % AM
1.6 % IV + 0.27 % AM
E4440A Opt.
23A
Frequency Modulation3 –
Measure
Rate: 20 Hz to 10 kHz
Deviation: 200 Hz to 40 kHz
Rate: 50 Hz to 200 kHz
Deviation: 250 Hz to 400 kHz
(0.25 to 10) MHz
>0.2 ß
>1.2 ß
(0.01 to 6.6) GHz
>0.2 ß
>0.45 ß
(6.6 to 13.2) GHz
>0.2 ß
>8 ß
(13.2 to 26.5) GHz
>0.2 ß
>16 ß
1.6 % IV + 5.7 Hz
1.0 % IV + 6.6 Hz
1.7 % IV + 5.6 Hz
1.2 % IV + 6.4 Hz
3.0 % IV + 12 Hz
1.2 % IV + 14 Hz
4.5 % IV + 24 Hz
1.2 % IV + 12 Hz
E4440A Opt.
23A
ß = Deviation /
Rate | ||
| 20 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4296.01) 03/27/2025 Page 20 of 25
Parameter/Range
Frequency
CMC2, 4, 7 (±)
Comments
Phase Modulation3 –
Measure
100 kHz to 6.6 Ghz
(6.6 to 13.2) GHz
(13.2 to 26.5) GHz
>0.7 rad
>0.3 rad
>2.0 rad
>0.6 rad
>4.0 rad
>1.2 rad
1.2 % + 0.019 rad
2.0 % + 0.022 rad
1.2 % + 0.011 rad
3.0 % + 0.015 rad
1.2 % + 0.006 rad
3.3 % + 0.011 rad
E4440A Opt. 23A
Modulation Distortion3 –
Measure
(-80 to 0) dB
200 Hz to 300 kHz
1.3 dB
E440A Opt 23A
Phase Noise3 – Measure
1 MHz to 26.5 GHz
Offset:
10 Hz
100 Hz
1 kHz
10 kHz
100 kHz
1 MHz
10 MHz
100 MHz
1.5 dBc/Hz
1.0 dBc/Hz
0.69 dBc/Hz
0.73 dBc/Hz
0.77 dBc/Hz
0.66 dBc/Hz
0.76 dBc/Hz
0.92 dBc/Hz
E4440A Opt 226
Audio Distortion3 – Measure
(-80 to 0) dB
(-65 to 0) dB
20 Hz to 20 kHz
20 kHz to 100 kHz
1.2 dB
2.4 dB
8903B | -80 to 0 dB |
| 21 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4296.01) 03/27/2025 Page 21 of 25
IV. Mechanical
Parameter/Equipment
Range
CMC2, 4, 6, 9 (±)
Comments
Torque – Measure Wrenches
& Drivers3
(1 to 2) lbf·in
(2 to 10) lbf·in
(5 to 50) lbf·in
(40 to 400) lbf·in
(100 to 1000) lbf·in
(50 to 250) lbf∙ft
(60 to 600) lbf∙ft
1.2 % + 0.58R
0.59 % + 0.58R
0.76 % + 0.58R
0.42 % + 0.58R
0.37 % + 0.58R
0.52 % + 0.58R
0.43 % + 0.58R
Torque testers
Force3 – Measure &
Measuring Equipment
Tension/Compression
(Up to 10000) lbf
0.009% + 0.4 lbf
Morehouse HADI
Morehouse
precision load cells
Pressure3 – Measure &
Measuring Equipment
Hydraulic
Pneumatic
(0 to 3000) psia
(3000 to 6000) psia
(6000 to 10 000) psia
(0 to 125) psig
(125 to 2500) psig
(0 to 1) psig
(1 to 20) psig
(0 to 50) psia
(0 to 1) inH
2O
(1 to 30) inH2O
(0 to 12.5) psig
(12.5 to 250) psig
0.5 psia + 0.58R
1 psia + 0.58R
1.7 psia + 0.58R
0.0081 % + 0.0063 psi
0.0095 % + 0.0044 psi
0.0001 psi + 0.58R
0.009 % + 0.58R
0.008 psia + 0.58R
0.000 68 inH
2O + 0.58R
0.011 % + 0.58R
0.0017 psi + 0.58R
0.0093 % + 0.58R
Ruska 7615
Fluke 7250xi
Fluke 7250xi
3
Ruska 6220
Fluke 7250LP
3
Fluke 7250xi
3
Vacuum3 – Measure &
Measuring Equipment
(-14.5 to 0) psi
0.0016 psi + 0.58R
Fluke 7250xi | ||
| 22 | - | Scales & BalancesShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4296.01) 03/27/2025 Page 22 of 25
Parameter
Range
CMC2, 4, 9 (±)
Comments
Scales & Balances3
2 mg
(5 to 500) mg
(1 to 2) g
5 g
10 g
20 g
50 g
100 g
200 g
500 g
1 kg
2 kg
5 kg
10 kg
20 kg
25 kg
30 kg
75 kg
0.0029 mg + 0.58R
0.012 mg + 0.58R
0.040 mg + 0.58R
0.0072 mg + 0.58R
0.013 mg + 0.58R
0.017 mg + 0.58R
0.019 mg + 0.58R
0.04 mg + 0.58R
0.07 mg + 0.58R
2.2 mg + 0.58R
3.1 mg + 0.58R
5.9 mg + 0.58R
14 mg + 0.58R
29 mg + 0.58R
110 mg + 0.58R
130 mg + 0.58R
130 mg + 0.58R
170 mg + 0.58R
Troemner platinum
class, & Class 1
weights
Mass – Measure
(1, 2, 3, 10, 20, 30, 100, 200,
300, 500) mg
(1, 2, 3, 5) g
10 g
20 g
30g
50 g
100 g
200 g
300 g
500 g
1 kg
2 kg
5 kg
10 kg
20 kg
25 kg
1 lb (453.59 g)
5 lb (2.27 kg)
10 lb (4.54 kg)
20 lb (9.07 kg)
25 lb (11.34 kg)
50 lb (22.68 kg)
0.002 mg
0.006 mg
0.007 mg
0.01 mg
0.03 mg
0.04 mg
0.07 mg
0.04 mg
0.1 mg
0.1 mg
0.3 mg
0.4 mg
3 mg
4 mg
5 mg
9 mg
0.4 mg
1.6 mg
3 mg
4 mg
4 mg
10 mg
Troemner ultra
class, Class 0,
Class 1 weights &
balances. | See scope document |
| 23 | ISO-8655-6; ISO-8655-8 | - | See scope document |
| 24 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4296.01) 03/27/2025 Page 24 of 25
Parameter
Range
CMC2, 4, 9 (±)
Comments
Humidity – Measuring
Equipment
(10 to 95) % RH
0.52 % RH + 0.58R
Thunder Scientific 2500
Temperature Sensors –
Measuring Equipment &
Measure
(0 to 70) °C
0.062 °C + 0.58R
Thunder Scientific 2500
Temperature3 – Measure
(-196 to 0) °C
(0 to 420) °C
(420 to 660) °C
0.0042 °C + 0.58R
0.0045 °C + 0.58R
0.0048 °C + 0.58R
Fluke 1594A & 5699
Temperature –
Measuring Equipment
-196 °C
(-60 to 0) °C
(0 to 420) °C
(420 to 550) °C
0.0042 °C + 0.58R
0.0042 °C + 0.58R
0.0045 °C + 0.58R
0.0048 °C + 0.58R
LN2 Fluke 1594A, 5699,
& baths
Infrared3 –
Thermometers &
Cameras
(-15 to 0) °C
(0 to 35) °C
(35 to 100) °C
(100 to 200) °C
(200 to 350) °C
(350 to 500) °C
0.55 °C + 0.58R
0.51 °C + 0.58R
0.46 °C + 0.58R
0.63 °C + 0.58R
0.95 °C + 0.58R
2.1 °C + 0.58R
Fluke 4180 & 4181
Emissivity ε = 0.95,
where λ = (8 to 14) µm
VII. Time & Frequency
Parameter
Range
CMC2, 4, 9 (±)
Comments
Frequency – Measuring
Equipment
5, 10 MHz
Up to 80 MHz
10 MHz to 50 GHz
Up to 80 MHz
10 MHz to 50 GHz
6.4 × 10-13 Hz/Hz
1.0 × 10
-11 Hz/Hz + 0.58R
8.6 × 10-12 Hz/Hz + 0.58R
5.9 × 10
-12 Hz/Hz + 0.58R
9.9 × 10-13 Hz/Hz + 0.58R
Caesium frequency
standard
Signal generator &
GPS reference
Signal generator &
caesium reference
Frequency3 – Measuring
Equipment
Up to 50 GHz
3.4 × 10-9 Hz/Hz + 0.58R
Signal generator &
53132A Opt 012 time
base | ||
| 25 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4296.01) 03/27/2025 Page 25 of 25
Parameter/Equipment
Range
CMC2, 4, 9 (±)
Comments
Stopwatches & Timers3
Up to 24 hours
27 ms + 0.58R
53132A & 33250A
Frequency – Measure
Up to 46 GHz
Up to 46 GHz
8.3 × 10-12 Hz/Hz + 0.58R
3.6 × 10
-12 Hz/Hz + 0.58R
Agilent 58503A &
53132A & E4440A
Frequency counter &
caesium reference
Frequency3 – Measure
Up to 46 GHz
3.1 × 10-9 Hz/Hz + 0.58R
Agilent 53132A &
E4440A
_____________________________________________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in micro-
inches. R is the resolution of the unit under test. D is the numerical value of the nominal diameter of the
device measured in micro-inches.
5 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for
the types of dimensional tests listed above and is considered equivalent to that of a calibration.
6 In the statement of CMC, percentages are of reading unless otherwise noted.
7 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a
percentage or fraction of the reading plus a fixed floor specification.
8 This scope meets A2LA’s P112 Flexible Scope Policy.
9 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | to 46 GHz |
| 26 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Anko ElectronicsAnaheim, CA · ~6 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Element U.S. Space & DefenseFullerton, CA · ~6 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Mitutoyo America CorporationCity of Industry, CA · ~19 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994