Mitsubishi Chemical America Inc, Soarnol Division
12220 Strang Road, Attn: Ashley Johnson, 77571, La Porte, TX, United States
Visit website- Accredited standards
- 5
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 5 standard numbers and the 3 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM D1238
ASTM D1895
ISO 1133-1Plastics - Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics - Part 1: Standard method
ISO 1133-2Plastics - Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics - Part 2: Method for materials sensitive to time-temperature history and/or moisture
ISO 11357Plastics - Differential scanning calorimetry (DSC)
ASTM D1238; ISO 1133-1; ISO 1133-2; ASTM D1895 (Method B); ISO 11357 (Parts 1 and 3); LM-0422; LM-0432
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.
Scope as published by A2LA
2 lines
ISO/IEC 17025
Active2317.01
The scope document we hold says it is valid until 2027-06-30.
Accredited scope, certificate 2317.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ASTM D1238; ISO 1133-1; ISO 1133-2; ASTM D1895 (Method B); ISO 11357 (Parts 1 and 3); LM-0422; LM-0432 | plastics and polymers | - |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
MITSUBISHI CHEMICAL AMERICA INC,
SOARNOL DIVISION
La Porte, TX
for technical competence in the field of
Mechanical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 30th day of September 2025.
______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 2317.01
Valid to June 30, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Advanced Composites, Inc. Ohio Facility - Main PlantSidney, OH · ~1,538 kmA2LAShares 1 accredited test methodASTM D1238
- Richard J. Bagan, Inc. D.B.A. Montech USAColumbia City, IN · ~1,540 kmA2LAShares 1 accredited test methodASTM D1238
- Chroma Color CorporationAsheboro, NC · ~1,571 kmA2LAShares 1 accredited test methodASTM D1238
- Element Materials Technology Detroit – Warren 11 MileWarren, MI · ~1,785 kmA2LAShares 1 accredited test methodASTM D1238
- Michigan Testing InstituteSterling Heights, MI · ~1,791 kmA2LAShares 1 accredited test methodASTM D1238
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.