Vacuum Technology
1003 Alvin Weinberg Drive, 37830, Oak Ridge, TN, United States
Visit website- Scope lines
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 1707.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | All Gases; Helium; Hydrogen; Nitrogen | See scope document |
| 2 | - | Air; All GasesShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1707.01) 1/13/2025 Page 2 of 2
Parameter/Equipment
Range
CMC2, 3, 4 (±)
Comments
Vacuum Gauges –
All Gases
1×10
-3 torr to 3000 psig
(1×10
-7 to 1×10-3) torr
2.5 %
5 %
VGMS w/ capacitance
manometer static
comparison
VGMS w/ spinning
rotor gauge dynamic
comparison
Volume – Measuring
Equipment
Air
10 cc to 25 L
2.5 %
Large leak calibration
system with gas
expansion method
____________________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 In the statement of CMC, percentages are to be read as percent of reading unless otherwise noted.
4 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
5 This scope meets A2LA’s P112 Flexible Scope Policy. | See scope document |
| 3 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Ludlum Measurements Inc. Knoxville Calibration DivisionKnoxville, TN · ~32 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Technical Maintenance, Inc. - WHITEWhite, GA · ~160 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- G.T. Michelli Co., LLC - LEBANONLebanon, TN · ~183 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Atlanta, GAAlpharetta, GA · ~215 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Constellation Powerlabs LLC - Piedmont, SCPiedmont, SC · ~219 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.