FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
China

Shenzhen QC Testing Laboratory CO.,

East of 1/F., Building E, Xinghong Science Park, No.111, Shuiku Road, Fenghuanggang, Xixiang Street, Bao'an District, Shenzhen, 518102, People's Republic of China, Shenzhen, China

A2LA|6759.01ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
7
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Shenzhen QC Testing Laboratory CO.,?

Claim this profile to keep it accurate.

Register record

A2LARefreshed
6759.01Active

Certificates and scope

1
A2LA

ISO/IEC 17025

Active

6759.01

The scope document we hold says it was valid until 2026-09-30. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.

View scope

Accredited scope, certificate 6759.01

LineDisciplineMethodMatrixRange
1electrical47 CFR, FCC Part 15, Subpart B (using ANSI C63.4:2014); 47 CFR, FCC Part 18 (using MP-5:1986); ICES-001; ICES-003; ICES-005; CISPR 11; EN 55011; AS CISPR 11; BS EN 55011; CISPR 14-1; EN 55014-1; EN IEC 55014-1; AS/NZS CISPR 14.1; AS CISPR 14.1; J 55014-1; BS EN 55014-1; BS EN IEC 55014-1; CISPR 15; EN IEC 55015; AS CISPR 15; J 55015; BS EN 55015; BS EN IEC 55015; CISPR 32; EN 55032; AS/NZS CISPR 32; CISPRJ 32; J 55032; BS EN 55032; IEC 61000-6-3; EN 61000-6-3; EN IEC 61000-6-3; AS/NZS 61000.6.3; BS EN 61000-6-3; BS EN IEC 61000-6-3; IEC 61000-6-4; EN 61000-6-4; EN IEC 61000-6-4; BS EN 61000-6-4; BS EN IEC 61000-6-4; AS/NZS 61000.6.4; AS 61000.6.4; IEC 61000-3-2; BS EN IEC 61000-3-2; EN IEC 61000-3-2; GB 17625.1; IEC 61000-3-3; EN 61000-3-3; BS EN 61000-3-3; GB/T 17625.2; CISPR 25; EN 55025; EN IEC 55025; BS EN 55025; BS EN IEC 55025; AS/NZS CIPR 25; EN 50498; BS EN 50498; ISO 7637-2; ECE R10; IEC 61000-4-2; EN 61000-4-2; BS EN 61000-4-2; IEC 61000-4-3; EN 61000-4-3; GB/T 17626.3; BS EN 61000-4-3; EN IEC 61000-4-3; BS EN 61000-4-3; BS EN IEC 61000-4-3-to 40 GHz
2----
3----
4electricalIEC 60335-1; EN 60335-1; AS/NZS 60335.1; BS EN 60335-1; IEC 60335-2-14; EN 60335-2-14; AS/NZS 60335.2.14; BS EN 60335-2-14; IEC 60335-2-23; BS EN 60335-2-23; EN 60335-2-23; AS/NZS 60335.2.23; IEC 60335-2-29; EN 60335-2-29; AS/NZS 60335.2.29; BS EN 60335-2-29; ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2013; FCC KDB 905462 D02 (v02); ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E; ANSI C63.26:2015-to 40000 MHz
5electricalANSI/TIA-603-E; ANSI/TIA-102.CAAA-E; ANSI C63.26:2015-to 40000 MHz
6electricalIEC 60950-1; IEC 60335-1--
7electrical---

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.