What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 21 standard numbers and the 17 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 61000 series6
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments+1 national
National versions in the same scope
AS/NZS 61000.6.3national version with changes
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments+1 national
National versions in the same scope
AS/NZS 61000.6.4identical to it
CISPR5
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS CISPR 11national version with changes
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+2 national
National versions in the same scope
AS CISPR 14.1national version with changes
AS/NZS CISPR 14.1national version with changes
CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment+1 national
National versions in the same scope
AS CISPR 15national version with changes
CISPR 25Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of on-board receivers
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+1 national
National versions in the same scope
AS/NZS CISPR 32identical to it
IEC 60335 series4
IEC 60335-1Household and similar electrical appliances - Safety - Part 1: General requirements+1 national
National versions in the same scope
AS/NZS 60335.1national version with changes
IEC 60335-2-14+1 national
National versions in the same scope
AS/NZS 60335.2.14national version with changes
IEC 60335-2-23+1 national
National versions in the same scope
AS/NZS 60335.2.23national version with changes
IEC 60335-2-29+1 national
National versions in the same scope
AS/NZS 60335.2.29national version with changes
Other standards6
ANSI/TIA-603-E
EN 50498Electromagnetic compatibility (EMC) - Product family standard for aftermarket electronic equipment in vehicles
FCC PART 15Radio Frequency Devices
ICES-001Industrial, Scientific and Medical (ISM) Equipment
IEC 60950-1Information technology equipment - Safety - Part 1: General requirements
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
47 CFR, FCC Part 15, Subpart B (using ANSI C63.4:2014); 47 CFR, FCC Part 18 (using MP-5:1986); ICES-001; ICES-003; ICES-005; CISPR 11; EN 55011; AS CISPR 11; BS EN 55011; CISPR 14-1; EN 55014-1; EN IEC 55014-1; AS/NZS CISPR 14.1; AS CISPR 14.1; J 55014-1; BS EN 55014-1; BS EN IEC 55014-1; CISPR 15; EN IEC 55015; AS CISPR 15; J 55015; BS EN 55015; BS EN IEC 55015; CISPR 32; EN 55032; AS/NZS CISPR 32; CISPRJ 32; J 55032; BS EN 55032; IEC 61000-6-3; EN 61000-6-3; EN IEC 61000-6-3; AS/NZS 61000.6.3; BS EN 61000-6-3; BS EN IEC 61000-6-3; IEC 61000-6-4; EN 61000-6-4; EN IEC 61000-6-4; BS EN 61000-6-4; BS EN IEC 61000-6-4; AS/NZS 61000.6.4; AS 61000.6.4; IEC 61000-3-2; BS EN IEC 61000-3-2; EN IEC 61000-3-2; GB 17625.1; IEC 61000-3-3; EN 61000-3-3; BS EN 61000-3-3; GB/T 17625.2; CISPR 25; EN 55025; EN IEC 55025; BS EN 55025; BS EN IEC 55025; AS/NZS CIPR 25; EN 50498; BS EN 50498; ISO 7637-2; ECE R10; IEC 61000-4-2; EN 61000-4-2; BS EN 61000-4-2; IEC 61000-4-3; EN 61000-4-3; GB/T 17626.3; BS EN 61000-4-3; EN IEC 61000-4-3; BS EN 61000-4-3; BS EN IEC 61000-4-3
IEC 60335-1; EN 60335-1; AS/NZS 60335.1; BS EN 60335-1; IEC 60335-2-14; EN 60335-2-14; AS/NZS 60335.2.14; BS EN 60335-2-14; IEC 60335-2-23; BS EN 60335-2-23; EN 60335-2-23; AS/NZS 60335.2.23; IEC 60335-2-29; EN 60335-2-29; AS/NZS 60335.2.29; BS EN 60335-2-29; ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2013; FCC KDB 905462 D02 (v02); ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E; ANSI C63.26:2015
IEC 60950-1; IEC 60335-1
ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E; ANSI C63.26:2015
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
7 lines
ISO/IEC 17025
Active6759.01
The scope document we hold says it was valid until 2026-09-30. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.
Accredited scope, certificate 6759.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | 47 CFR, FCC Part 15, Subpart B (using ANSI C63.4:2014); 47 CFR, FCC Part 18 (using MP-5:1986); ICES-001; ICES-003; ICES-005; CISPR 11; EN 55011; AS CISPR 11; BS EN 55011; CISPR 14-1; EN 55014-1; EN IEC 55014-1; AS/NZS CISPR 14.1; AS CISPR 14.1; J 55014-1; BS EN 55014-1; BS EN IEC 55014-1; CISPR 15; EN IEC 55015; AS CISPR 15; J 55015; BS EN 55015; BS EN IEC 55015; CISPR 32; EN 55032; AS/NZS CISPR 32; CISPRJ 32; J 55032; BS EN 55032; IEC 61000-6-3; EN 61000-6-3; EN IEC 61000-6-3; AS/NZS 61000.6.3; BS EN 61000-6-3; BS EN IEC 61000-6-3; IEC 61000-6-4; EN 61000-6-4; EN IEC 61000-6-4; BS EN 61000-6-4; BS EN IEC 61000-6-4; AS/NZS 61000.6.4; AS 61000.6.4; IEC 61000-3-2; BS EN IEC 61000-3-2; EN IEC 61000-3-2; GB 17625.1; IEC 61000-3-3; EN 61000-3-3; BS EN 61000-3-3; GB/T 17625.2; CISPR 25; EN 55025; EN IEC 55025; BS EN 55025; BS EN IEC 55025; AS/NZS CIPR 25; EN 50498; BS EN 50498; ISO 7637-2; ECE R10; IEC 61000-4-2; EN 61000-4-2; BS EN 61000-4-2; IEC 61000-4-3; EN 61000-4-3; GB/T 17626.3; BS EN 61000-4-3; EN IEC 61000-4-3; BS EN 61000-4-3; BS EN IEC 61000-4-3 | - | to 40 GHz |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6759.01) 9/19/2024 Page 2 of 6
Test Technology:
Test Method(s) 1:
Immunity (Continued)
Electrical Fast
Transient/Burst (EFT)
IEC 61000-4-4; EN 61000-4-4; BS EN 61000-4-4
Surge Immunity IEC 61000-4-5; EN 61000-4-5; BS EN 61000-4-5
Conducted Immunity IEC 61000-4-6; EN 61000-4-6; BS EN 61000-4-6
Power frequency
magnetic field immunity
test
IEC 61000-4-8; EN 61000-4-8; BS EN 61000-4-8
Voltage Dips, Short
Interruptions, and
Voltage Variations
IEC 61000-4-11; EN 61000-4-11; EN IEC 61000-4-11; BS EN 61000-4-11;
BS EN IEC 61000-4-11
Ring wave immunity IEC 61000-4-12; EN 61000-4-12; BS EN 61000-4-12
Harmonics and
interharmonics including
mains signalling at a.c.
power port,low
frequency immunity
IEC 61000-4-13; EN 61000-4-13; BS EN 61000-4-13
Immunity—Electronic
Equipment in Vehicles
ISO 10605; ISO 10605:2008; ISO 10605:2023; ISO 7637-2; ISO 7637-3;
ISO 16750-2; ISO 11452-2;
ISO 11452-4; ISO 11452-9; ECE R10
Electromagnetic Fields
(EMF)
IEC 62233; EN 62233; BS EN 62233
Product Standards
(excluding audio
breakthrough test of
Clause 6.1.1.1 and
6.1.1.2 of standard
ETSI EN 301 489-52)
CISPR 35; EN 55035; BS EN 55035; IEC 61547; EN 61547;
BS EN 61547; CISPR 14-2; EN 55014-2; EN IEC 55014-2; BS EN 55014-2;
BS EN IEC 55014-2; BS EN IEC 61000-6-1; IEC 61000-6-1;
EN IEC 61000-6-1; AS/NZS 61000.6.1; IEC 61000-6-2; EN IEC 61000-6-2;
AS/NZS 61000.6.2; BS EN IEC 61000-6-2; ETSI EN 300 386; EN 61326-1;
EN IEC 61326-1; BS EN 61326-1; BS EN IEC 61326-1; EN 61326-2-1;
EN IEC 61326-2-1; BS EN IEC 61326-2-1; BS EN IEC 61326-2-1;
EN 61326-2-2; EN IEC 61326-2-2; BS EN 61326-2-2;
BS EN IEC 61326-2-2; EN 61326-2-3; EN IEC 61326-2-3;
BS EN 61326-2-3; BS EN IEC 61326-2-3; EN 61326-2-4;
EN IEC 61326-2-4; BS EN61326-2-4; BS EN IEC 61326-2-4;
EN 61326-2-5; EN IEC 61326-2-5; BS EN 61326-2-5;
BS EN IEC 61326-2-5; EN 61326-2-6; EN IEC 61326-2-6;
BS EN 61326-2-6; BS EN IEC 61326-2-6; IEC 61326-1; IEC 61326-2-1;
IEC 61326-2-2; IEC 61326-2-3; IEC 61326-2-4; IEC 61326-2-5;
IEC 61326-2-6; IEC 60601-1-2; EN 60601-1-2; BS EN 60601-1-2;
EN 50130-4; BS EN 50130-4; EN 50270; BS EN 50270; EN 50121-3-2;
BS EN 50121-3-2; EN 60945; IEC 60945; BS EN 60945; | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6759.01) 9/19/2024 Page 3 of 6
Test Technology:
Test Method(s) 1:
ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-7;
ETSI EN 301 489-9; ETSI EN 301 489-17; ETSI EN 301 489-19;
ETSI EN 301 489-24; ETSI EN 301 489-34; ETSI EN 301 489-52;
ICES-Gen Issue 1
RF Testing ETSI EN 300 220-1; ETSI EN 300 220-2; ETSI EN 300 220-3-1;
ETSI EN 300 220-3-2; ETSI EN 300 220-4; ETSI EN 300 330;
ETSI EN 303 417; ETSI EN 300 440; ETSI EN 301 357;
ETSI EN 300 422-1; ETSI EN 300 422-2; ETSI EN 300 422-3;
ETSI EN 301 511; ETSI EN 303 609; ETSI EN 302 291-1;
ETSI EN 302 291-2; ETSI EN 302 208; ETSI EN 300 328;
ETSI EN 301 893, ETSI EN 302 502; ETSI EN 303 345-1;
ETSI EN 303 345-2; ETSI EN 303 345-3; ETSI EN 303 345-4;
ETSI EN 303 345-5; ETSI EN 303 413; ETSI EN 301 908-1;
ETSI EN 301 908-2; ETSI EN 301 908-13; EN 50663; EN 50665;
EN 62311; EN IEC 62311; BS EN 62311; BS EN IEC 62311; BS EN 50663;
BS EN 50665; EN 62479; BS EN 62479; ETSI EN 302 065-1;
ETSI EN 302 065-2; ETSI EN 302 065-3; ETSI EN 302 065-4;
ETSI EN 302 065-5; AS/NZS 4268;
47 CFR FCC Part 15 Subpart C (using ANSI C63.10:2013) (up to 40 GHz);
47 CFR FCC Part 15 Subpart E, U-NII without DFS Intentional Radiators
(using ANSI C63.10:2013);
47 CFR FCC Part 15 Subpart E, U-NII with DFS Intentional Radiators
(using FCC KDB 905462 D02);
47 CFR FCC Part 15 Subpart F (using ANSI C63.10:2013);
47 CFR FCC Parts 22, 24, 27, 74, 90, 95, 97, and 101
(using TIA-603-E-2016, ANSI/TIA-102.CAAA-E, ANSI C63.26:2015);
RSS-GEN; RSS-102; RSS-130; RSS-132; RSS-133; RSS-139; RSS-199;
RSS-210; RSS-215; RSS-216; RSS-247 (with DFS); RSS-248; RSS-310;
ARIB STD-T66; ARIB STD-T33
Electrical Product
Safety
ITAV, Information
Technology, Audio,
Video
*See Table #1
Exclusion List Below
IEC 62368-1; EN IEC 62368-1; BS EN 62368-1; AS/NZS 62368.1;
UL 62368-1
Audio, Video
*See Table #2
Exclusion List Below
AS/NZS 60065; IEC 60065
ITAV, Information
Technology
*See Table #3
Exclusion List Below
AS/NZS 60950.1; IEC 60950-1 | ||
| 4 | IEC 60335-1; EN 60335-1; AS/NZS 60335.1; BS EN 60335-1; IEC 60335-2-14; EN 60335-2-14; AS/NZS 60335.2.14; BS EN 60335-2-14; IEC 60335-2-23; BS EN 60335-2-23; EN 60335-2-23; AS/NZS 60335.2.23; IEC 60335-2-29; EN 60335-2-29; AS/NZS 60335.2.29; BS EN 60335-2-29; ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2013; FCC KDB 905462 D02 (v02); ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E; ANSI C63.26:2015 | - | to 40000 MHz |
| 5 | ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E; ANSI C63.26:2015 | - | to 40000 MHz |
| 6 | IEC 60950-1; IEC 60335-1 | - | - |
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
SHENZHEN QC TESTING LABORATORY CO., LTD.
Shenzhen, People’s Republic of China
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 19th day of September 2024.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 6759.01
Valid to September 30, 2026 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Labs with overlapping accredited scope in China
- Dongguan Nore Testing Center Co.,Dongguan, GuangdongA2LAShares 2 accredited test methodsANSI/TIA-603-EICES-001
- Eurofins Electrical Testing Service (Shanghai) Co.,ShanghaiA2LAShares 2 accredited test methodsICES-001IEC 60335-1
- Guangdong Global Testing Technology Co.,DongguanA2LAShares 2 accredited test methodsANSI/TIA-603-EICES-001
- Intertek Testing Services (Shanghai FTZ) Co.,ShanghaiA2LAShares 2 accredited test methodsANSI/TIA-603-EICES-001
- Intertek Testing Services Shenzhen Ltd., Longhua BranchShenzhenA2LAShares 2 accredited test methodsANSI/TIA-603-EICES-001
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.