Komplex90 Badanie Materiałów
ul. Gliwicka 86, 43-190, Mikołów, Poland
Visit website- Accredited standards
- 10
- PCA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the PCA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 10 standard numbers and the 10 official names we hold. When no standard matches, it searches the method text of every scope line.
EN 10160Ultrasonic testing of steel flat product of thickness equal to or greater than 6 mm (reflection method)
EN 13018Non-destructive testing - Visual testing - General principles
ISO 3452-1Non-destructive testing - Penetrant testing - Part 1: General principles
ISO 9934-1Non-destructive testing - Magnetic particle testing - Part 1: General principles
ISO 16809Non-destructive testing - Ultrasonic thickness determination
ISO 16810Non-destructive testing - Ultrasonic testing - General principles
ISO 17636-1Non-destructive testing of welds - Radiographic testing - Part 1: X- and gamma-ray techniques with film
ISO 17637Non-destructive testing of welds - Visual testing of fusion-welded joints
ISO 17638Non-destructive testing of welds - Magnetic particle testing
ISO 17640Non-destructive testing of welds - Ultrasonic testing - Techniques, testing levels, and assessment
PN-EN ISO 17636-1:2023-06; PN-EN ISO 16810:2025-04; PN-EN 10160:2001; PN-EN ISO 17640:2019-01; PN-EN ISO 16809:2019-08; PN-EN ISO 9934-1:2017-02; PN-EN ISO 17638:2017-01; PN-EN ISO 3452-1:2021-12; PN-EN 13018:2016-04; PN-EN ISO 17637:2017-02
Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-20.
Scope as published by PCA
2 lines
ISO/IEC 17025
ActiveAB 1886
The scope document we hold says it is valid until 2027-12-05.
Accredited scope, certificate AB 1886
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | Construction products and materialsShow page textExtracted from the scope document; tables may not line up. View scope for the original. PCA Zakres akredytacji Nr AB 1886
Scope of accreditation No. AB 1886
ZAKRES AKREDYTACJI
LABORATORIUM BADAWCZEGO
SCOPE OF ACCREDITATION FOR TESTING LABORATORY
Nr/No. AB 1886
wydany przez / issued by
POLSKIE CENTRUM AKREDYTACJI
01-382 Warszawa, ul. Szczotkarska 42
Wydanie/Issue 2 z/of 18.11.2025
KIEROWNIK DZIAŁU AKREDYTACJI
BADAŃ MECHANICZNYCH I FIZYCZNYCH
MARIA SZAFRAN
Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr A B 1886 z dnia 06.12.2023 r.
Cykl akredytacji od 06.12.2023 r. do 05.12.2027 r.
Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl
This document is an annex to accreditation certificate No. AB 1886 of 06.12.2023
Accreditation cycle from 06.12.2023 to 05.12.2027
The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl
Wydanie nr / Issue No. 2, 18.11.2025 1/3
Nazwa i adres / Name and address
„KOMPLEX 90” BADANIE MATERIAŁÓW SP. Z O.O.
Laboratorium Badań Nieniszczących Komplex 90
ul. Gliwicka 86
43-190 Mikołów
Kod identyfikacyjny /
Identification code *) Dziedzina i przedmiot badań / Field of testing and item:
- L/8 - Badania nieniszczące – wyroby i materiały konstrukcyjne / Non-destructive tests – construction
products and materials
Wersja strony/Page version: A
*) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB -07 dostępnym na stronie internetowej www.pca.gov.pl /
The identification code according to the Annex to document DAB -07, available at PCA website www.pca.gov.pl
AB 1886 | - |
| 2 | PN-EN ISO 17636-1:2023-06; PN-EN ISO 16810:2025-04; PN-EN 10160:2001; PN-EN ISO 17640:2019-01; PN-EN ISO 16809:2019-08; PN-EN ISO 9934-1:2017-02; PN-EN ISO 17638:2017-01; PN-EN ISO 3452-1:2021-12; PN-EN 13018:2016-04; PN-EN ISO 17637:2017-02 | Złącza spawane materiałów metalowych; Wyroby stalowe płaskie; Wyroby i materiały metalowe; Wyroby i materiały metalowe ferromagnetyczne | 2 to 100 mm |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Poland
- Laboratorium Spawalnicze "GAMMA-MONTEX"Częstochowa · ~73 kmPCAShares 2 accredited methods and materialsEN ISO 3452-1:2021-12Construction products and materials
- Świętokrzyskie Centrum Badania JakościOstrowiec Świętokrzyski · ~197 kmPCAShares 2 accredited methods and materialsEN ISO 3452-1:2021-12Construction products and materials
- NAVITEST Sp. z o.o.Gdańsk · ~474 kmPCAShares 2 accredited methods and materialsEN ISO 3452-1:2021-12Construction products and materials
- Staltest PomorzeGdańsk · ~474 kmPCAShares 2 accredited methods and materialsEN ISO 3452-1:2021-12Construction products and materials
- Ośrodek Badań i Certyfikacji SIMPTESTCERTKatowice · ~9 kmPCAShares 1 accredited materialConstruction products and materials
Accreditation data refreshed from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.