Świętokrzyskie Centrum Badania Jakości
ul. Aleja Solidarności 9, 27-400, Ostrowiec Świętokrzyski, Poland
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Świętokrzyskie Centrum Badania Jakości?
Claim this profile to keep it accurate.
Register record
- PCARefreshed
- AB 1336Active
Certificates and scope
1ISO/IEC 17025
ActiveAB 1336
The scope document we hold says it is valid until 2028-05-20.
Accredited scope, certificate AB 1336
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | mechanical | - | Construction products and materials | - |
| 2 | materials | PN-EN ISO 3452-1:2021-12; PN-EN 1371-1:2012; PN-EN 10228-2:2016-07; PN-EN ISO 9934-1:2017-02; PN-EN ISO 17638:2017-01; PN-EN 1369:2013-04; PN-EN 10228-1:2016-07; PN-EN ISO 5579:2014-02; PN-EN ISO 17636-1:2023-02; PN-EN 13018:2016-04; PN-EN ISO 17637:2017-02; PN-EN ISO 16810:2014-06; PN-EN ISO 17640:2019-01; PN-EN 10160:2001; PN-EN 10228-3:2016-07; PN-EN 10228-4:2016-07; PN-EN 12680-1:2005; PN-EN 12680-2:2005; PN-EN 12680-3:2012; PN-EN ISO 16809:2019-08; PN-EN ISO 6892-1:2020-05; PN-EN ISO 4136:2022-12; PN-EN ISO 7438:2021-04; PN-EN ISO 5173:2023-06 | Wyroby i materiały metalowe; Odlewy; Odkuwki stalowe; Złącza spawane materiałów i wyrobów ferromagnetycznych; Złącza spawane; Wyroby stalowe płaskie; Odlewy staliwne i żeliwne; Metale, stopy metali, wyroby metalowe | 2 to 200 mm |
| 3 | materials | PN-EN ISO 148-1:2017-02; PN-EN ISO 9016:2022-09; PN-EN ISO 9017:2018-03; PN-EN ISO 6506-1:2014-12; PN-EN ISO 6508-1:2024-06; PN-EN ISO 6507-1:2024-04; DIN 50159-1:2022-06; PN-EN ISO 17639:2022-07 | Metale, stopy metali, wyroby metalowe; Złącza spawane | to 650 HBW |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Poland
- Laboratorium Spawalnicze "GAMMA-MONTEX"Częstochowa · ~161 kmPCAShares 2 accredited methods and materialsEN ISO 3452-1:2021-12Construction products and materials
- Komplex90 Badanie MateriałówMikołów · ~197 kmPCAShares 2 accredited methods and materialsEN ISO 3452-1:2021-12Construction products and materials
- NAVITEST Sp. z o.o.Gdańsk · ~425 kmPCAShares 2 accredited methods and materialsEN ISO 3452-1:2021-12Construction products and materials
- Staltest PomorzeGdańsk · ~425 kmPCAShares 2 accredited methods and materialsEN ISO 3452-1:2021-12Construction products and materials
- NAFTO Spółka AkcyjnaKraków · ~144 kmPCAShares 1 accredited materialConstruction products and materials
Accreditation data refreshed from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.