Registers refreshed 2026-11-20.See refresh dates
United Kingdom

Kiwa Ltd t/a Kiwa Electrical Compliance

Arnolds Court, Arnolds Farm Lane, Mountnessing, Brentwood, CM13 1UT, Essex, United Kingdom

Visit website
UKAS 2360ISO/IEC 17025Register refreshed 2026-11-20
Part of the Kiwa group: 40 sites in our directory.

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
80
UKAS certificate
1
Site in our directory
1
UKAS accredited scope

What this lab is accredited for

Our reading of the UKAS scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 80 standard numbers and the 36 official names we hold. When no standard matches, it searches the method text of every scope line.

ETSI39
ETSI EN 300 086-1
ETSI EN 300 086-2
ETSI EN 300 113-1
ETSI EN 300 113-2
ETSI EN 300 220-1
ETSI EN 300 220-2
ETSI EN 300 220-3
ETSI EN 300 225
ETSI EN 300 296Exclusion

Limits written next to it

EN 300 296:V2.1.1 (Excluding clause 7.6

Exclusion. Written next to it on line 8 of UKAS certificate 2360.

ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 330-1
ETSI EN 300 330-2
Show all 39
ETSI EN 300 422-1Exclusion

Limits written next to it

EN 300 422-1 V1.4.2 (Except for

Exclusion. Written next to it on line 9 of UKAS certificate 2360.

ETSI EN 300 422-2Exclusion

Limits written next to it

EN 300 422-2 V1.3.1 (Except for

Exclusion. Written next to it on line 9 of UKAS certificate 2360.

ETSI EN 300 440-1
ETSI EN 300 440-2
ETSI EN 300 720Exclusion

Limits written next to it

EN 300 720:V2.1.1 (Excluding clause 7)

Exclusion. Written next to it on line 9 of UKAS certificate 2360.

ETSI EN 301 178Exclusion

Limits written next to it

EN 301 178:V2.2.2 (Excluding clause 7)

Exclusion. Written next to it on line 9 of UKAS certificate 2360.

ETSI EN 301 357-1
ETSI EN 301 357-2
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-4
ETSI EN 301 489-5
ETSI EN 301 489-9
ETSI EN 301 489-17
ETSI EN 301 489-19
ETSI EN 301 489-33
ETSI EN 301 489-52
ETSI EN 301 511Global System for Mobile communications (GSM); Mobile Stations (MS) equipment; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EUSome clauses

Limits written next to it

EN 301 511 V12.5.1 (Clause 4.2.16 to

Some clauses. Written next to it on line 9 of UKAS certificate 2360.

ETSI EN 301 893
ETSI EN 301 908-1
ETSI EN 302 065-2
ETSI EN 302 326-2
ETSI EN 302 567Exclusion

Limits written next to it

EN 302 567 V2.1.1 (Excluding clause

Exclusion. Written next to it on line 11 of UKAS certificate 2360.

EN 302 567 V2.2.1 (Excluding clause

Exclusion. Written next to it on line 11 of UKAS certificate 2360.

ETSI EN 303 413Satellite Earth Stations and Systems (SES); Global Navigation Satellite System (GNSS) receivers; Radio equipment operating in the 1 164 MHz to 1 300 MHz and 1 559 MHz to 1 610 MHz frequency bands; Harmonised Standard for access to radio spectrum
ETSI EN 303 722
ETSI EN 305 550-1
ETSI EN 305 550-2
CISPR10
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement

Certificate says EN 55011-200. Probably the same standard; not checked against the EN document.

CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission

Certificate says EN 55014-1. Probably the same standard; not checked against the EN document.

CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard

Certificate says EN 55014-2. Probably the same standard; not checked against the EN document.

CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment

Certificate says EN 55015. Probably the same standard; not checked against the EN document.

CISPR 16-2-1Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements

Certificate says EN 55016-2-1. Probably the same standard; not checked against the EN document.

CISPR 16-2-3Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements

Certificate says EN 55016-2-3. Probably the same standard; not checked against the EN document.

CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement

Certificate says EN 55022. Probably the same standard; not checked against the EN document.

CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurement

Certificate says EN 55024. Probably the same standard; not checked against the EN document.

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirementsExclusion

Limits written next to it

EN 55035:2017 (Excluding Broadband

Exclusion. Written next to it on line 6 of UKAS certificate 2360.

EN 55035:2017 + A11 2020 (Excluding

Exclusion. Written next to it on line 6 of UKAS certificate 2360.

Certificate says EN 55035. Probably the same standard; not checked against the EN document.

EN7
EN 50081-1
EN 50081-2
EN 50082-1
EN 50121-3-2Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - ApparatusExclusion

Limits written next to it

EN 50121-3-2:2016 (Excluding AC

Exclusion. Written next to it on line 6 of UKAS certificate 2360.

EN 50130-4Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
EN 50498Electromagnetic compatibility (EMC) - Product family standard for aftermarket electronic equipment in vehicles
EN 55103-2
IEC 61000 series7
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments

Certificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.

IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
IEC5
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 60801-2

Certificate says IEC 801-2. Probably the same standard; not checked against the EN document.

IEC 60801-4

Certificate says IEC 801-4. Probably the same standard; not checked against the EN document.

IEC 60945Maritime navigation and radiocommunication equipment and systems - General requirements - Methods of testing and required test results
IEC 61547Equipment for general lighting purposes - EMC immunity requirements

Certificate says EN 61547. Probably the same standard; not checked against the EN document.

IEC 61326 series5
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61326-2-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications
IEC 61326-2-2Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems
IEC 61326-2-3Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning
IEC 61326-2-6Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical electrical equipment
ANSI3
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ANSI C63.10
ANSI C63.26
ISO3
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
Other standards1
FCC PART 15Radio Frequency Devices

Read from the scope as published by UKAS. Register refreshed 2026-11-20.

Scope as published by UKAS

18 lines
UKAS

ISO/IEC 17025

Active

2360

View scope

Location

Arnolds Court, Arnolds Farm Lane, Mountnessing, Brentwood, Essex, CM13 1UT, GB

51.64633, 0.35673

Open in Maps

Accreditation data refreshed from the UKAS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the UKAS entry linked above.