Registers refreshed 2026-11-08.See refresh dates
United States

EXTRON

1001 E. Ball Rd., 92805, Anaheim, CA, United States

Visit website
A2LA 3429.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
26
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 26 standard numbers and the 18 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 61000 series9
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)+2 national

National versions in the same scope

AS/NZS 61000.3.2identical to it

KS C 9610-3-2national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection+2 national

National versions in the same scope

AS/NZS 61000.3.3identical to it

KS C 9610-3-3national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test+2 national

National versions in the same scope

AS/NZS 61000.4.2probably the same standard; matched by number only

KS C 9610-4-2national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06. The others are matched by number only.

IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test+2 national

National versions in the same scope

AS/NZS 61000.4.3probably the same standard; matched by number only

KS C 9610-4-3national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06. The others are matched by number only.

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test+2 national

National versions in the same scope

AS/NZS 61000.4.4probably the same standard; matched by number only

KS C 9610-4-4national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06. The others are matched by number only.

IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test+2 national

National versions in the same scope

AS IEC 61000.4.5probably the same standard; matched by number only

KS C 9610-4-5national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06. The others are matched by number only.

IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields+2 national

National versions in the same scope

AS IEC 61000.4.6probably the same standard; matched by number only

KS C 9610-4-6national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06. The others are matched by number only.

IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test+2 national

National versions in the same scope

AS/NZS 61000.4.8probably the same standard; matched by number only

KS C 9610-4-8national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06. The others are matched by number only.

IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase+2 national

National versions in the same scope

AS/NZS 61000.4.11probably the same standard; matched by number only

KS C 9610-4-11probably the same standard; matched by number only

ETSI8
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 301 406
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-6
ETSI EN 301 489-17
ETSI EN 301 893
ETSI EN 303 687
CISPR5
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+1 national

National versions in the same scope

AS CISPR 11national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55011. Probably the same standard; not checked against the EN document.

CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement+1 national

National versions in the same scope

AS/NZS CISPR 22identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55022. Probably the same standard; not checked against the EN document.

CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurement+1 national

National versions in the same scope

AS/NZS CISPR 24identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55024. Probably the same standard; not checked against the EN document.

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+4 national

National versions in the same scope

AS/NZS CISPR 32identical to it

CNS 15936identical to it

KS C 9832national version with changes

VCCI-CISPR 32probably the same standard; matched by number only

Identical and changed are as the national standards body lists them; we read that on 2026-10-06. The others are matched by number only.

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements+1 national

National versions in the same scope

KS C 9835national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55035. Probably the same standard; not checked against the EN document.

Other standards4
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ANSI C63.10
FCC PART 15Radio Frequency DevicesExclusion

Limits written next to it

CFR 47, FCC Part 15 Subpart E (excluding DFS testing),

Exclusion. Written next to it on line 3 of A2LA certificate 3429.01.

IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.

Scope as published by A2LA

6 lines
A2LA

ISO/IEC 17025

Active

3429.01

The scope document we hold says it is valid until 2027-06-30.

View scope

Accredited scope, certificate 3429.01

LineMethodMatrixRange
1FCC CFR 47; FCC Part 15 Subpart B; ANSI C63.4-2014; ISED ICES-003; VCCI VCCI-CISPR 32:2016; EN 55011; CISPR 11; EN 55022; CISPR 22 Ed. 6, 2008-09; CISPR 22; CISPR 32; EN 55032; EN / IEC 60601-1-2; AS CISPR 11: 2017 + A1:2020; AS/NZS CISPR 22:2009 + A1:2010; AS/NZS CISPR 32:2015+A1:2020; SANS 211; CISPR 11; SABS CISPR 11; SANS 222; CISPR 22; SABS CISPR 22; SANS 2332; CISPR 32; SANS 60601-1-2; CNS 15936 (2016); GB/T 9254.1-2021; KS C 9832:2024--
2CISPR 32; SI 961 Part 32; QCVN 118:2018/BTTTT (CISPR 32:2015); HKTA 1007 (CISPR 11); EN / IEC / UK EN / IEC 61000-3-2; AS/NZS 61000.3.2:2023; SANS 61000-3-2:2009; IEC 61000-3-2:2009; KS C 9610-3-2; EN / IEC / UK EN / IEC 61000-3-3; AS/NZS 61000.3.3:2023; SANS 61000-3-3:2009; IEC 61000-3-2:2008; KS C 9610-3-3; EN & CISPR / IEC / UK EN 55024; CISPR 24 Ed 2.0, 2010-08; CISPR 24; EN 55035; CISPR 35; EN / IEC 61000-4-2; EN / IEC 61000-4-3; EN / IEC 61000-4-4; EN / IEC 61000-4-5; EN / IEC 61000-4-6; EN / IEC 61000-4-8; EN / IEC 61000-4-11; EN / IEC 60601-1-2; AS/NZS CISPR 24:2013; AS/NZS 61000.4.2:2013; AS/NZS 61000.4.3:2021; AS/NZS 61000.4.4:2013; AS IEC 61000.4.5:2017; AS IEC 61000.4.6:2024; AS/NZS 61000.4.8:2012; AS/NZS 61000.4.11:2005-to 40 GHz
3SANS 2335:2018; CISPR 35:2016; SANS 61000-4-2:2009; IEC 61000-4-2:2008; SANS 61000-4-3:2008; IEC 61000-4-3:2008; SANS 61000-4-4:2011; IEC 61000-4-4:2011; SANS 61000-4-5:2006; IEC 61000-4-5:2005; SANS 61000-4-6:2017; IEC 61000-4-6:2008; SANS 61000-4-8:2009; IEC 61000-4-8:2009; SANS 61000-4-11:2005; IEC 61000-4-11:2005; KS C 9835:2019; KS C 9610-4-2; KS C 9610-4-3; KS C 9610-4-4; KS C 9610-4-5; KS C 9610-4-6; KS C 9610-4-8; KS C 9610-4-11; CISPR 24, Edition 2.1:2015-04; SI 961 Part 24; TCVN 7317:2003; CISPR 24:1997; GB/T 9254.2-2021; FCC CFR 47, FCC Part 15 Subpart C; ANSI C63.10-2020; CFR 47, FCC Part 15 Subpart E; ANSI C63.10: 2020; ISED RSS-GEN; RSS-247; RSS-248; EN 301 406; EN 301 489-1; EN 301 489-3; EN 301 489-6; EN 301 489-17; EN 300 328; EN 301 893; EN 303 687-to 40 GHz
4AS/NZS 4268:2017 + Amd 1: 2021; ETSI EN 300 328 V2.2.2(2019-07); IMDA TS SRD; IMDA TS CT-CTS; HKCA 1039; HKTA 1034; HKCA 1042; HKCA 1081; SANS 301 489-1:2005; ETSI EN 301 489-1:2005; SANS 301 489-3:2014; ETSI EN 301 489-3:2014; SANS 301 489-6:2016; ETSI EN 301 489-6:2008; SANS 301 489-17:2016; ETSI EN 301 489-17:2012; SANS 301 406:2015; ETSI EN 301 406:2009; KS X 3123:2023; KS X 3124:2020; KS X 3125:2020; KS X 3126:2020; KS X 3128:2014; QCVN 18:2022/BTTTT; QCVN 65:2021/BTTTT; QCVN 113:2017/BTTTT; LP0002:2024; RTTE01:2020; MCMC MTSFB TC T007:2014; IFT-008-2015; IFT-016-2024; IFT-017-2023; NOM-208-SCFI-2016; IEEE C95.3--
5ANSI C63.4:2014; ANSI C63.10:2020-to 40000 MHz
6

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited EXTRON Anaheim, CA for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 27th day of May 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 3429.01 Valid to June 30, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1001 E. Ball Rd., Anaheim, CA, 92805, US

33.83475, -117.91173

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.