Powiatowa Stacja Sanitarno-Epidemiologiczna w Tychach
ul. Budowlanych 131, 43-100, Tychy, Poland
- Accredited standards
- 18
- PCA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the PCA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 18 standard numbers and the 16 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO13
ISO 6059Water quality - Determination of the sum of calcium and magnesium - EDTA titrimetric method
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
ISO 6332Water quality - Determination of iron - Spectrometric method using 1,10-phenanthroline
ISO 7027-1Water quality - Determination of turbidity - Part 1: Quantitative methods
ISO 7887Water quality - Examination and determination of colour
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 8467Water quality - Determination of permanganate index
ISO 9297Water quality - Determination of chloride - Silver nitrate titration with chromate indicator (Mohr's method)
ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
ISO 9308-3Water quality - Detection and enumeration of Escherichia coli and coliform bacteria - Part 3: Miniaturized method (Most Probable Number) for the detection and enumeration of E. coli in surface and waste water
ISO 10523Water quality - Determination of pH
ISO 11731Water quality - Enumeration of Legionella
ISO 16266Water quality - Detection and enumeration of Pseudomonas aeruginosa - Method by membrane filtration
EN3
EN 872Water quality - Determination of suspended solids - Method by filtration through glass fibre filters
EN 26777Water quality - Determination of nitrite - Molecular absorption spectrometric method
EN 27888Water quality - Determination of electrical conductivity
Other standards2
C-04576-4:1994
PN-82/C-04576.08
PN-EN 26777:1999; PN-C-04576-4:1994; PN-82/C-04576.08; PN-ISO 9297:1994; PN-EN ISO 8467:2001; PN-ISO 6059:1999; PN-ISO 6332:2001+Ap1:2016-06; PN-EN 872:2007+Ap1:2007; PN-EN ISO 7027-1:2016-09; PN-EN ISO 10523:2012; PN-EN 27888:1999
PN-EN ISO 9308-1:2014-12 +A1:2017-04; PN-EN ISO 7899-2:2004; PN-EN ISO 11731:2017-08 +AP1:2019-12; PN-EN ISO 6222:2004; PN-EN ISO 16266:2009; PN-EN ISO 9308-3:2002; Metodyka PZH ZHK:2007
PN-EN ISO 7887:2012+Ap1:2015; OLKŚ/PB-02 wyd. 2 z dn. 02.01.2020r.; PN-82/C-04576.08; PN-EN ISO 8467:2001; PN-ISO 6332:2001+Ap1:2016-06; PN-EN ISO 10523:2012; OL/KŚ/PB-03 wyd. 5 z dn. 09.01.2025 r.; PN-EN ISO 7027-1:2016-09
Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-20.
Scope as published by PCA
5 lines
ISO/IEC 17025
ActiveAB 500
The scope document we hold says it is valid until 2028-07-08.
Accredited scope, certificate AB 500
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | WaterShow page textExtracted from the scope document; tables may not line up. View scope for the original. PCA Zakres akredytacji Nr AB 500
Scope of accreditation No AB 500
ZAKRES AKREDYTACJI
LABORATORIUM BADAWCZEGO
SCOPE OF ACCREDITATION FOR TESTING LABORATORY
Nr/No AB 500
wydany przez / issued by
POLSKIE CENTRUM AKREDYTACJI
01-382 Warszawa, ul. Szczotkarska 42
Wydanie/Issue 28 z/of 12.05.2025
KIEROWNIK DZIAŁU AKREDYTACJI
BADAŃ I CERTYFIKACJI ŻYWNOŚCI
HANNA TUGI
Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr AB 500 z dnia 26.11.2020 r.
Cykl akredytacji od 11.06.2024 r. do 08.07.2028 r.
Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl
This document is an annex to accreditation certificate No AB 500 of 23.06.2020
Accreditation cycle from 11.06.2024 to 08.07.2028
The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl
Wydanie nr / Issue No 28, 12.05.2025 1/6
Nazwa i adres / Name and address
POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA
W TYCHACH
ul. Budowlanych 131
43-100 Tychy
Kod identyfikacyjny /
Identification code *) Dziedzina i przedmiot badań / Field of testing and item:
- C/28, C/29 - Badania chemiczne wody, wody do spożycia przez ludzi / Chemical tests of water, drinking water
- K/3, K/28, K/29 - Badania mikrobiologiczne obiektów i materiałów biologicznych przeznaczonych do badań, wody,
wody do spożycia pr zez ludzi / Microbiological tests of biological items and materials for testing,
water, drinking water
- N/28, N/29 - Badania właściwości fizycznych wody, wody do spożycia przez ludzi / Tests of physical properties of
water, drinking water
Wersja strony/Page version: A
*) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB -07 dostępnym na stronie internetowej www.pca.gov.pl /
The identification code according to the Annex to document DAB -07, available at PCA website www.pca.gov.pl
AB 500 | - |
| 2 | PN-EN 26777:1999; PN-C-04576-4:1994; PN-82/C-04576.08; PN-ISO 9297:1994; PN-EN ISO 8467:2001; PN-ISO 6059:1999; PN-ISO 6332:2001+Ap1:2016-06; PN-EN 872:2007+Ap1:2007; PN-EN ISO 7027-1:2016-09; PN-EN ISO 10523:2012; PN-EN 27888:1999 | Drinking water | See scope document |
| 3 | PN-EN ISO 7887:2012+Ap1:2015; OLKŚ/PB-02 wyd. 2 z dn. 02.01.2020r.; PN-82/C-04576.08; PN-EN ISO 8467:2001; PN-ISO 6332:2001+Ap1:2016-06; PN-EN ISO 10523:2012; OL/KŚ/PB-03 wyd. 5 z dn. 09.01.2025 r.; PN-EN ISO 7027-1:2016-09 | Drinking water | See scope document |
| 4 | PN-EN ISO 9308-1:2014-12 +A1:2017-04; PN-EN ISO 7899-2:2004; PN-EN ISO 11731:2017-08 +AP1:2019-12; PN-EN ISO 6222:2004; PN-EN ISO 16266:2009; PN-EN ISO 9308-3:2002; Metodyka PZH ZHK:2007 | Drinking water | - |
| 5 | - | Kał; Biologiczne wskaźniki kontroli skuteczności sterylizacji (Sporal A, Sporal S)Show page textExtracted from the scope document; tables may not line up. View scope for the original. PCA Zakres akredytacji Nr AB 500
Wydanie nr 28, 12.05.2025 r. 5/6
Oddział Laboratoryjny
Sekcja Badań Chorób Zakaźnych i Zakażeń
ul. Budowlanych 131, 43-100 Tychy
Przedmiot badań/wyrób Rodzaj działalności/
badane cechy/metoda Dokumenty odniesienia
Kał
Obecność pałeczek Salmonella spp.
i Shigella spp.
Metoda hodowlana z potwierdzeniem
biochemicznym i serologicznym
OL/B/PB-01
wydanie 8 z dnia 10.01.2022 r.
W oparciu o „Etiologia, obraz kliniczny
i diagnostyka ostrych zakażeń i
zarażeń przewodu pokarmowego oraz
zatruć pokarmowych” pod redakcją
Marka Jagielskiego Warszawa 2010
Obecność pałeczek Salmonella
Enteritidis
Metoda hodowlana z potwierdzeniem
biochemicznym i serologicznym
Obecność pałeczek Escherichia coli
Metoda hodowlana z potwierdzeniem
biochemicznym
OL/B/PB-04
wydanie 4 z dnia 02.01.2020 r.
W oparciu o „Etiologia, obraz kliniczny
i diagnostyka ostrych zakażeń i
zarażeń przewodu pokarmowego oraz
zatruć pokarmowych” pod redakcją
Marka Jagielskiego Warszawa 2010
Obecność i identyfikacja pałeczek
Yersinia sp.
Metoda hodowlana z potwierdzeniem
biochemicznym
OL/B/PB-06
wydanie 4 z dnia 02.01.2020 r.
W oparciu o „Etiologia, obraz kliniczny
i diagnostyka ostrych zakażeń i
zarażeń przewodu pokarmowego oraz
zatruć pokarmowych” pod redakcją
Marka Jagielskiego Warszawa 2010
Biologiczne wskaźniki kontroli
skuteczności sterylizacji
(Sporal A, Sporal S)
Obecność drobnoustrojów
wskaźnikowych Geobacillus
stearothermophilus
Metoda hodowlana
OL/B/PB-02
wydanie 5 z dnia 10.01.2022 r.
W oparciu o instrukcje producenta
testów
Obecność drobnoustrojów
wskaźnikowych Bacillus subtilis
Metoda hodowlana
Wersja strony: A | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Poland
- MS LAB POZNAŃPoznań · ~292 kmPCAShares 3 accredited methods and materialsPN-82/C-04576.08Drinking waterWater
- LabStar Mateusz OlejnikStargard · ~450 kmPCAShares 3 accredited methods and materialsEN 26777:1999Drinking waterWater
- Centrum Badań i DozoruLędziny · ~10 kmPCAShares 2 accredited materialsDrinking waterWater
- Eurofins OBIKŚ PolskaKatowice · ~11 kmPCAShares 2 accredited materialsDrinking waterWater
- SGS Polska Sp. z o.o.Pszczyna · ~16 kmPCAShares 2 accredited materialsDrinking waterWater
Accreditation data refreshed from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.