Intel Corporation - Oregon CPRS
5200 N.E. Elam Young Parkway, 97124-6497, Hillsboro, OR, United States
- Accredited standards
- 9
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 9 standard numbers and the 7 official names we hold. When no standard matches, it searches the method text of every scope line.
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ASTM E573
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
KS C 9811national version with changes
CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+3 national
National versions in the same scope
CNS 15936identical to it
KS C 9832national version with changes
VCCI-CISPR 32probably the same standard; matched by number only
FCC PART 15Radio Frequency Devices
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)+1 national
National versions in the same scope
KS C 9610-3-2national version with changes
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection+1 national
National versions in the same scope
KS C 9610-3-3national version with changes
IEC 62321-3-1
IEC 62321-3-1:2013-06; IEC 62321-3-1; ASTM E573; ANSI C63.4:2014; FCC MP-5:1986
47 CFR, FCC Part 15, Subpart B (using ANSI 63.4:2014); 47 CFR, FCC Part 18, (using MP-5:1986); CISPR 11:2009+A1:2010; CISPR 11:2015; CISPR 11; CISPR 11:2015+A1:2016 CSV+A2:2019 CSV; CISPR 22:2005+AMD 1:2005-07; CISPR 22:2005+AMD 1:2005-07+AMD 2:2006; CISPR 22:2008; CISPR 22; CISPR 32:2012; CISPR 32:2015; CISPR 32:2015+AMD1:2019 CSV; CISPR 32; CNS 15936:2016; CNS 15936 (up to 6 GHz); EN 55011:2009+A1:2010; EN 55011:2016; EN 55011:2016/A1:2017; EN 55011:2016/A11:2020; EN 55011; EN 55022:2010; EN 55022; EN 55032:2012/AC:2013; EN 55032:2015; EN 55032:2015/A11:2020; EN 55032; EN 61000-3-2:2014; EN 61000-3-2; EN 61000-3-3:2013; EN 61000-3-3; KS C 9811; KS C 9610-3-2; KS C 9610-3-3; KS C 9832 3m only; (excluding equipment under the scope of CISPR 13) QCVN 118:2018/BTTTT; TCVN 7189:2009; TCVN 7189 (up to 6 GHz); VCCI 32-1; VCCI-CISPR 32
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
4 lines
ISO/IEC 17025
Active1130.01
The scope document we hold says it was valid until 2026-05-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.
Accredited scope, certificate 1130.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | 47 CFR, FCC Part 15, Subpart B (using ANSI 63.4:2014); 47 CFR, FCC Part 18, (using MP-5:1986); CISPR 11:2009+A1:2010; CISPR 11:2015; CISPR 11; CISPR 11:2015+A1:2016 CSV+A2:2019 CSV; CISPR 22:2005+AMD 1:2005-07; CISPR 22:2005+AMD 1:2005-07+AMD 2:2006; CISPR 22:2008; CISPR 22; CISPR 32:2012; CISPR 32:2015; CISPR 32:2015+AMD1:2019 CSV; CISPR 32; CNS 15936:2016; CNS 15936 (up to 6 GHz); EN 55011:2009+A1:2010; EN 55011:2016; EN 55011:2016/A1:2017; EN 55011:2016/A11:2020; EN 55011; EN 55022:2010; EN 55022; EN 55032:2012/AC:2013; EN 55032:2015; EN 55032:2015/A11:2020; EN 55032; EN 61000-3-2:2014; EN 61000-3-2; EN 61000-3-3:2013; EN 61000-3-3; KS C 9811; KS C 9610-3-2; KS C 9610-3-3; KS C 9832 3m only; (excluding equipment under the scope of CISPR 13) QCVN 118:2018/BTTTT; TCVN 7189:2009; TCVN 7189 (up to 6 GHz); VCCI 32-1; VCCI-CISPR 32 | - | - |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1130.01) Revised 03/03/2026 Page 2 of 3
Test Technology: Test Method(s):
Radiated / Line Conducted Emissions
(Continued)
IEC 61000-3-2:2014; IEC 61000-3-2;
IEC 61000-3-3:2013; IEC 61000-3-3;
ICES-001 (Issue 5); ICES 003 (Issue 7);
CSA CISPR 11:2019; CSA CISPR 11; AS CISPR 11;
AS/NZS CISPR 11:2011; AS CISPR 11:2017;
CAN/CSA CISPR 32:2017; CAN/CSA CISPR 32;
AS/NZS CISPR 32:2015; AS/NZS CISPR 32
ISM IEC 61326-1:2012; IEC 61326-1;
EN 61326-1:2013; EN 61326-1
Immunity CISPR 24:2010; CISPR 24 Ed. 2.1:2015-04;
CISPR 24:2010+AMD1:2015 CSV; CISPR 24;
CISPR 35:2016; CISPR 35;
EN 55024:2010; EN 55024;
EN 55035:2017; EN 55035;
EN 55035:2017/A11:2020;
EN 61000-6-1:2007; EN 61000-6-1;
IEC 61000-6-1:2005; IEC 61000-6-1;
KS C 9610-6-1; KS C 9835
(excluding equipment under the scope of CISPR 20);
TCVN 7317:2003; TCVN 7317
ESD IEC 61000-4-2:2008; IEC 61000-4-2;
EN 61000-4-2:2009; EN 61000-4-2
Radiated IEC 61000-4-3:2006+A1:2007+A2:2010;
EN 61000-4-3:2006+A1:2008+A2:2010;
IEC 61000-4-3; EN 61000-4-3
Electric Fast Transient / Burst IEC 61000-4-4:2012; IEC 61000-4-4:2004+A1:2010;
EN 61000-4-4:2012; EN 61000-4-4:2004+A1:2010;
IEC 61000-4-4; EN 61000-4-4
Surge IEC 61000-4-5:2014; IEC 61000-4-5:2005;
IEC 61000-4-5; EN 61000-4-5:2014;
EN 61000-4-5:2006; EN 61000-4-5
Conducted IEC 61000-4-6:2013; IEC 61000-4-6:2008;
IEC 61000-4-6; EN 61000-4-6:2014;
EN 1000-4-6:2009; EN 61000-4-6
Power Frequency Magnetic Field IEC 61000-4-8:2009; IEC 61000-4-8;
EN 61000-4-8:2010; IEC 61000-4-8
Voltage Dips, Short Interruptions,
and Voltage Variations
IEC 61000-4-11:2004; IEC 61000-4-11;
EN 61000-4-11:2004; EN 61000-4-11 | ||
| 3 | IEC 62321-3-1:2013-06; IEC 62321-3-1; ASTM E573; ANSI C63.4:2014; FCC MP-5:1986 | - | to 40000 MHz |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
INTEL CORPORATION – OREGON CPRS LABS
Hillsboro, OR
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 5th day of April 2024.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 1130.01
Valid to May 31, 2026
Revised March 3, 2026 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- ElectroMagnetic InvestigationsHillsboro, OR · under 1 kmA2LAShares 2 accredited test methodsANSI C63.4:2014CISPR 11
- CETECOMMilpitas, CA · ~901 kmA2LAShares 2 accredited test methodsANSI C63.4:2014CISPR 11
- HCT AmericaMilpitas, CA · ~904 kmA2LAShares 2 accredited test methodsANSI C63.4:2014CISPR 11
- Vista Laboratories, Inc.San Clemente, CA · ~1,421 kmA2LAShares 2 accredited test methodsANSI C63.4:2014CISPR 11
- Intertek Testing Services NAFridley, MN · ~2,312 kmA2LAShares 2 accredited test methodsANSI C63.4:2014CISPR 11
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.