Registers refreshed 2026-11-20.See refresh dates
United States

Intel Corporation - Oregon CPRS

5200 N.E. Elam Young Parkway, 97124-6497, Hillsboro, OR, United States

A2LA 1130.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
9
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 9 standard numbers and the 7 official names we hold. When no standard matches, it searches the method text of every scope line.

ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ASTM E573
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+1 national

National versions in the same scope

KS C 9811national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55011. Probably the same standard; not checked against the EN document.

CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement

Certificate says EN 55022. Probably the same standard; not checked against the EN document.

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+3 national

National versions in the same scope

CNS 15936identical to it

KS C 9832national version with changes

VCCI-CISPR 32probably the same standard; matched by number only

Identical and changed are as the national standards body lists them; we read that on 2026-10-06. The others are matched by number only.

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

FCC PART 15Radio Frequency Devices
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)+1 national

National versions in the same scope

KS C 9610-3-2national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection+1 national

National versions in the same scope

KS C 9610-3-3national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 62321-3-1

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

4 lines
A2LA

ISO/IEC 17025

Active

1130.01

The scope document we hold says it was valid until 2026-05-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.

View scope

Accredited scope, certificate 1130.01

LineMethodMatrixRange
147 CFR, FCC Part 15, Subpart B (using ANSI 63.4:2014); 47 CFR, FCC Part 18, (using MP-5:1986); CISPR 11:2009+A1:2010; CISPR 11:2015; CISPR 11; CISPR 11:2015+A1:2016 CSV+A2:2019 CSV; CISPR 22:2005+AMD 1:2005-07; CISPR 22:2005+AMD 1:2005-07+AMD 2:2006; CISPR 22:2008; CISPR 22; CISPR 32:2012; CISPR 32:2015; CISPR 32:2015+AMD1:2019 CSV; CISPR 32; CNS 15936:2016; CNS 15936 (up to 6 GHz); EN 55011:2009+A1:2010; EN 55011:2016; EN 55011:2016/A1:2017; EN 55011:2016/A11:2020; EN 55011; EN 55022:2010; EN 55022; EN 55032:2012/AC:2013; EN 55032:2015; EN 55032:2015/A11:2020; EN 55032; EN 61000-3-2:2014; EN 61000-3-2; EN 61000-3-3:2013; EN 61000-3-3; KS C 9811; KS C 9610-3-2; KS C 9610-3-3; KS C 9832 3m only; (excluding equipment under the scope of CISPR 13) QCVN 118:2018/BTTTT; TCVN 7189:2009; TCVN 7189 (up to 6 GHz); VCCI 32-1; VCCI-CISPR 32--
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1130.01) Revised 03/03/2026 Page 2 of 3 Test Technology: Test Method(s): Radiated / Line Conducted Emissions (Continued) IEC 61000-3-2:2014; IEC 61000-3-2; IEC 61000-3-3:2013; IEC 61000-3-3; ICES-001 (Issue 5); ICES 003 (Issue 7); CSA CISPR 11:2019; CSA CISPR 11; AS CISPR 11; AS/NZS CISPR 11:2011; AS CISPR 11:2017; CAN/CSA CISPR 32:2017; CAN/CSA CISPR 32; AS/NZS CISPR 32:2015; AS/NZS CISPR 32 ISM IEC 61326-1:2012; IEC 61326-1; EN 61326-1:2013; EN 61326-1 Immunity CISPR 24:2010; CISPR 24 Ed. 2.1:2015-04; CISPR 24:2010+AMD1:2015 CSV; CISPR 24; CISPR 35:2016; CISPR 35; EN 55024:2010; EN 55024; EN 55035:2017; EN 55035; EN 55035:2017/A11:2020; EN 61000-6-1:2007; EN 61000-6-1; IEC 61000-6-1:2005; IEC 61000-6-1; KS C 9610-6-1; KS C 9835 (excluding equipment under the scope of CISPR 20); TCVN 7317:2003; TCVN 7317 ESD IEC 61000-4-2:2008; IEC 61000-4-2; EN 61000-4-2:2009; EN 61000-4-2 Radiated IEC 61000-4-3:2006+A1:2007+A2:2010; EN 61000-4-3:2006+A1:2008+A2:2010; IEC 61000-4-3; EN 61000-4-3 Electric Fast Transient / Burst IEC 61000-4-4:2012; IEC 61000-4-4:2004+A1:2010; EN 61000-4-4:2012; EN 61000-4-4:2004+A1:2010; IEC 61000-4-4; EN 61000-4-4 Surge IEC 61000-4-5:2014; IEC 61000-4-5:2005; IEC 61000-4-5; EN 61000-4-5:2014; EN 61000-4-5:2006; EN 61000-4-5 Conducted IEC 61000-4-6:2013; IEC 61000-4-6:2008; IEC 61000-4-6; EN 61000-4-6:2014; EN 1000-4-6:2009; EN 61000-4-6 Power Frequency Magnetic Field IEC 61000-4-8:2009; IEC 61000-4-8; EN 61000-4-8:2010; IEC 61000-4-8 Voltage Dips, Short Interruptions, and Voltage Variations IEC 61000-4-11:2004; IEC 61000-4-11; EN 61000-4-11:2004; EN 61000-4-11
3IEC 62321-3-1:2013-06; IEC 62321-3-1; ASTM E573; ANSI C63.4:2014; FCC MP-5:1986-to 40000 MHz
4

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited INTEL CORPORATION – OREGON CPRS LABS Hillsboro, OR for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 5th day of April 2024. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 1130.01 Valid to May 31, 2026 Revised March 3, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

5200 N.E. Elam Young Parkway, Hillsboro, OR, 97124-6497, US

45.52289, -122.98983

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.