SGS-CEC New Energy Technology (Chongqing) Co.,
Building 13 & 14, No. 1839, Ranjun Road, Shuangfu Street, Jiangjin District, Chongqing, China, ChongQing, People's Republic of China, ChongQing, China
Visit website- Accredited standards
- 20
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 20 standard numbers and the 3 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC12
IEC 60335-1Household and similar electrical appliances - Safety - Part 1: General requirements+1 national
National versions in the same scope
AS/NZS 60335.1national version with changes
IEC 60335-2-29+1 national
National versions in the same scope
AS/NZS 60335.2.29national version with changes
IEC 61851-1
IEC 61851-23
IEC 62040-1
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements+1 national
National versions in the same scope
AS/NZS 62368.1national version with changes
IEC 62368-3
IEC 62477-1+1 national
National versions in the same scope
AS IEC 62477.1probably the same standard; matched by number only
IEC 62752
IEC 62933-2-1
IEC 62933-5-2
IEC 62955
IEC 61439 series7
IEC 61439-1+1 national
National versions in the same scope
AS/NZS 61439.1probably the same standard; matched by number only
IEC 61439-2+1 national
National versions in the same scope
AS/NZS 61439.2probably the same standard; matched by number only
IEC 61439-3+1 national
National versions in the same scope
AS/NZS 61439.3probably the same standard; matched by number only
IEC 61439-4+1 national
National versions in the same scope
AS/NZS 61439.4probably the same standard; matched by number only
IEC 61439-5+1 national
National versions in the same scope
AS/NZS 61439.5probably the same standard; matched by number only
IEC 61439-6+1 national
National versions in the same scope
AS/NZS 61439.6probably the same standard; matched by number only
IEC 61439-7
Other standards1
ISO 6469-1Electrically propelled road vehicles - Safety specifications - Part 1: Rechargeable energy storage system (RESS)
IEC 62368-1; EN 62368-1; EN IEC 62368-1; UL 62368-1; CSA C22.2 No. 62368-1; BS EN 62368-1; BS EN IEC 62368-1; AS/NZS 62368.1; IEC 62368-3; IEC 60335-1; EN 60335-1; EN IEC 60335-1; BS EN IEC 60335-1; AS/NZS 60335.1; IEC 60335-2-29; EN IEC 60335-2-29; BS EN 60335-2-29; BS EN IEC 60335-2-29; AS/NZS 60335.2.29; AS/NZS 60335.2.114; IEC 62040-1; EN IEC 62040-1; BS EN IEC 62040-1; AS 62040.1; UL 1778; CSA C22.2 No. 107.3; IEC 62477-1; EN IEC 62477-1; BS EN IEC 62477-1; AS IEC 62477.1; SA TS 5398; AS/NZS 4763; UL 1012; CSA No. 22.2 No. 107.1; CSA No. 22.2 No. 107.2; IEC 61851-1; EN IEC 61851-1; TR25-1; TR25-2; TR25-3; TR25-4; IEC 61851-23; EN IEC 61851-23; UL 2594; CSA C22.2 No. 280; UL 2231-1; CAN/CSA-C22.2 No.281.1; UL 2231-2; CAN/CSA-C22.2 No.281.2; IEC 62752; EN 62752; IEC 62955; UL 9741; CSA C22.2 No. 348; IET 01; UL 67; UL 869A; UL 916; UL 1008; IEC 61439-1; EN IEC 61439-1; AS/NZS 61439.1; IEC 61439-2; EN IEC 61439-2; AS/NZS 61439.2; IEC 61439-7; EN IEC 61439-7; IEC 61439-3
ANSI/UL 9540; CAN/UL 9540; IEC 62933-2-1; IEC 62933-5-2; TR 77-1; IEC TS 62933-3-1; TR 77-2; IEC TS 62933-5-1; TR 77-3; IEC TS 62933-3-2; IEC 62368-1; EN 62368-1; EN IEC 62368-1; UL 62368-1; CSA C22.2 No. 62368-1; BS EN 62368-1; BS EN IEC 62368-1; AS/NZS 62368.1; IEC 62040-1; EN IEC 62040-1; BS EN IEC 62040-1; AS 62040.1; UL 1778; CSA C22.2 No. 107.3; IEC 62477-1; EN 62477-1; BS EN 62477-1; ISO 6469-1; SAE J2464; IEC 60335-1; EN 60335-1; EN IEC 60335-1; BS EN 60335-1; AS/NZS 60335.1; UL 1741 Supplement SA; UL 1741 Supplement SB; UL 2594; IEC 61439-1; EN IEC 61439-1; AS/NZS 61439.1; IEC 61439-2; EN IEC 61439-2; AS/NZS 61439.2; IEC 61439-7; EN IEC 61439-7; IEC 61439-3; EN IEC 61439-3; AS/NZS 61439.3; IEC 61439-4; EN 61439-4; AS/NZS 61439.4; IEC 61439-5; EN IEC 61439-5; AS/NZS 61439.5; IEC 61439-6; EN 61439-6; AS/NZS 61439.6
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
4 lines
ISO/IEC 17025
Active6670.01
The scope document we hold says it is valid until 2028-05-31.
Accredited scope, certificate 6670.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | IEC 62368-1; EN 62368-1; EN IEC 62368-1; UL 62368-1; CSA C22.2 No. 62368-1; BS EN 62368-1; BS EN IEC 62368-1; AS/NZS 62368.1; IEC 62368-3; IEC 60335-1; EN 60335-1; EN IEC 60335-1; BS EN IEC 60335-1; AS/NZS 60335.1; IEC 60335-2-29; EN IEC 60335-2-29; BS EN 60335-2-29; BS EN IEC 60335-2-29; AS/NZS 60335.2.29; AS/NZS 60335.2.114; IEC 62040-1; EN IEC 62040-1; BS EN IEC 62040-1; AS 62040.1; UL 1778; CSA C22.2 No. 107.3; IEC 62477-1; EN IEC 62477-1; BS EN IEC 62477-1; AS IEC 62477.1; SA TS 5398; AS/NZS 4763; UL 1012; CSA No. 22.2 No. 107.1; CSA No. 22.2 No. 107.2; IEC 61851-1; EN IEC 61851-1; TR25-1; TR25-2; TR25-3; TR25-4; IEC 61851-23; EN IEC 61851-23; UL 2594; CSA C22.2 No. 280; UL 2231-1; CAN/CSA-C22.2 No.281.1; UL 2231-2; CAN/CSA-C22.2 No.281.2; IEC 62752; EN 62752; IEC 62955; UL 9741; CSA C22.2 No. 348; IET 01; UL 67; UL 869A; UL 916; UL 1008; IEC 61439-1; EN IEC 61439-1; AS/NZS 61439.1; IEC 61439-2; EN IEC 61439-2; AS/NZS 61439.2; IEC 61439-7; EN IEC 61439-7; IEC 61439-3 | - | - |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6670.01) 02/27/2026 Page 2 of 3
Test(s):
Test Method(s)1, 2:
Low Voltage Power Assembly
(cont.)
EN IEC 61439-3; AS/NZS 61439.3
IEC 61439-4; EN 61439-4; AS/NZS 61439.4;
IEC 61439-5; EN IEC 61439-5; AS/NZS 61439.5;
IEC 61439-6; EN 61439-6; AS/NZS 61439.6; IEC 62909-1;
EN IEC 62909-1; IEC 62909-2; EN IEC 62909-2; UL 4900;
UL 1977
Performance Test
IP Test
IEC 60529; EN 60529; ISO 20653
Environmental Testing
IEC 60068-2-6; IEC 60068-2-52
Mechanical testing IEC 60068-2-75; IEC 62262; IEC 60068-2-27
Battery Test
Consumer Battery IEC 62133-1; EN 62133-1; UL 62133-1;
CSA C22.2 No. 62133-1; IEC 62133-2; EN 62133-2;
UL 62133-2; CSA C22.2 No. 62133-2; UL 1642; UL 2054;
ST/SG/AC.10/11/Section 38.3; IEC 62281; EN IEC 62281;
IEC 63118-1; EN IEC 63118-1
ESS/EV IEC 62619; EN IEC 62619; IEC 62620; EN 62620;
JIS C 8715-1; JIS C 8715-2; INMETRO Ordinance 140;
IEC 63056; EN IEC 63056; ANSI/UL 9540A;
CAN/UL 9540A; IEC 63057; EN IEC 63057; ANSI/UL 2743;
CAN/UL 2743;
ANSI/UL 1973; CAN/UL 1973; VDE 2510-50;
IEC 62660-1; EN IEC 62660-1; IEC 62660-2;
EN IEC 62660-2;
IEC 62660-3; EN IEC 62660-3;
UN ECE R100; ANSI/UL 2580; CAN/ULC 2580;
ISO 12405-4; ISO 6469-1; SAE J2380; SAE J2464;
IEC 62282-3-100; CSA/ANSI FC 1;
CSA C22.2 NO. 62282-3-100;
VDE-AR-E 2510-2; IEC 62932-2-2;
EN IEC 62932-2-2;
IEC 61373;
UL 9540B; IEC 62282-4-101;
IEC 62282-2-100; IEC 63115-1; IEC 63115-2;
UL 1487; EN 18060; IEC 62282-5-100; UL 5800
LEV & LEV Battery
UN ECE R136; ANSI/UL 2271; CAN/ULC 2271;
ANSI/UL 2272; CAN/UL 2272; ANSI/UL 2849;
CAN/UL 2849; UL 2850; EN 17128; EN 50604-1;
ISO 13063-1; ISO 13063-2; ISO 13063-3; EN 15194;
ISO 18243; EN ISO 18243 | ||
| 3 | ANSI/UL 9540; CAN/UL 9540; IEC 62933-2-1; IEC 62933-5-2; TR 77-1; IEC TS 62933-3-1; TR 77-2; IEC TS 62933-5-1; TR 77-3; IEC TS 62933-3-2; IEC 62368-1; EN 62368-1; EN IEC 62368-1; UL 62368-1; CSA C22.2 No. 62368-1; BS EN 62368-1; BS EN IEC 62368-1; AS/NZS 62368.1; IEC 62040-1; EN IEC 62040-1; BS EN IEC 62040-1; AS 62040.1; UL 1778; CSA C22.2 No. 107.3; IEC 62477-1; EN 62477-1; BS EN 62477-1; ISO 6469-1; SAE J2464; IEC 60335-1; EN 60335-1; EN IEC 60335-1; BS EN 60335-1; AS/NZS 60335.1; UL 1741 Supplement SA; UL 1741 Supplement SB; UL 2594; IEC 61439-1; EN IEC 61439-1; AS/NZS 61439.1; IEC 61439-2; EN IEC 61439-2; AS/NZS 61439.2; IEC 61439-7; EN IEC 61439-7; IEC 61439-3; EN IEC 61439-3; AS/NZS 61439.3; IEC 61439-4; EN 61439-4; AS/NZS 61439.4; IEC 61439-5; EN IEC 61439-5; AS/NZS 61439.5; IEC 61439-6; EN 61439-6; AS/NZS 61439.6 | - | - |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s «field» Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
SGS-CEC NEW ENERGY TECHNOLOGY
(CHONGQING) CO., LTD
Chongqing, People’s Republic of China
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 27th day of February 2026.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 6670.01
Valid to May 31, 2028 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Labs with overlapping accredited scope in China
- Attestation of Global Compliance (Shenzhen) Co.,GuangdongA2LAShares 1 accredited test methodIEC 62368-1
- BTL Inc. (Dongguan)Dongguan, GuangdongA2LAShares 1 accredited test methodIEC 62368-1
- Bureau Veritas Shenzhen Co., Ltd. Dongguan BranchDongguan City, Guangdong ProvinceA2LAShares 1 accredited test methodIEC 62368-1
- Centre Testing International Group Co.,Shenzhen, GuangdongA2LAShares 1 accredited test methodIEC 62368-1
- CTC Laboratories, Inc.Shenzhen, GuangdongA2LAShares 1 accredited test methodIEC 62368-1
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.