Registers refreshed 2026-11-08.See refresh dates
United States

Schweitzer Engineering

2350 NE Hopkins Ct., 99163, Pullman, WA, United States

Visit website
A2LA 3354.01A2LA 3354.02ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
30
A2LA certificates
2
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 30 standard numbers and the 19 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC8
IEC 60529Degrees of protection provided by enclosures (IP Code)
IEC 60825-1
IEC 60825-2
IEC 61131-2
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements

Certificate says EN 61326-1. Probably the same standard; not checked against the EN document.

IEC 61326-2-2Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems
IEC 61850-3
IEC 61869-13
IEC 60255 series6
IEC 60255-1
IEC 60255-21-1
IEC 60255-21-2
IEC 60255-21-3
IEC 60255-26
IEC 60255-27
IEC 60068 series5
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
IEC 61000 series5
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments+1 national

National versions in the same scope

KS C 9610-6-2national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments+1 national

National versions in the same scope

KS C 9610-6-4national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

CISPR4
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+2 national

National versions in the same scope

AS/NZS CISPR 11national version with changes

KS C 9811national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55011. Probably the same standard; not checked against the EN document.

CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement

Certificate says EN 55022. Probably the same standard; not checked against the EN document.

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+1 national

National versions in the same scope

KS C 9832national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements+1 national

National versions in the same scope

KS C 9835national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55035. Probably the same standard; not checked against the EN document.

Other standards2
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
FCC PART 15Radio Frequency Devices

Read from the A2LA scope documents we downloaded on 2026-10-27. Register refreshed 2026-11-06.

Scope as published by A2LA

8 lines
A2LA

ISO/IEC 17025

Active

3354.01

The scope document we hold says it is valid until 2028-07-31.

View scope

Accredited scope, certificate 3354.01

LineMethodMatrixRange
147 CFR, Part 15 Subpart B (using ANSI C63.4:2014); CISPR 11; CISPR 11:2009 + A1:2010; EN 55011; EN 55011:2009 + A1:2010; CISPR 22; CISPR 22:2008; EN 55022; EN 55022:2010 + AC:2011; CISPR 32:2015 + A1:2019; EN 55032; EN 55032:2012 (excluding Broadcast Receivers); ICES-001 Issue 5; ICES-003 Issue 7; CSA CISPR 11:19; CNS 13438:2006 (up to 6 GHz); AS/NZS CISPR 11; KS C 9811; KN 22; KS C 9832 (excluding broadcast receiver equipment); IEC 61000-3-2; IEC 61000-3-2:2014; EN 61000-3-2; EN 61000-3-2:2014; IEC 61000-3-3; IEC 61000-3-3:2013; EN 61000-3-3; EN 61000-3-3:2013; IEEE C37.90.1; IEEE C37.90.1:2012; IEC 61000-4-2; IEC 61000-4-2:2008; IEEE C37.90.3; IEEE C37.90.3:2001; EN 61000-4-2; EN 61000-4-2:2009protective relays; substation equipment; devices intended to operate with protective relays and substation equipment-
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3354.01) 08/14/2026 Page 2 of 5 Test: Test Method(s) 1: Radiated RF Immunity IEC 61000-4-3; IEC 61000-4-3:2006 + A1:2007 + A2:2010; EN 61000-4-3; EN 61000-4-3:2006 + A1:2008 + A2:2010; IEEE C37.90.2; IEEE C37.90.2:2004 Electrical Fast Transient Burst Immunity IEC 61000-4-4; IEC 61000-4-4:2012; EN 61000-4-4; EN 61000-4-4:2012 Surge Immunity IEC 61000-4-5; IEC 61000-4-5:2005 + Corr:2009; EN 61000-4-5; EN 61000-4-5:2006 Conducted RF Immunity IEC 61000-4-6; IEC 61000-4-6:2008; EN 61000-4-6; EN 61000-4-6:2009 Power Frequency Magnetic Field (Greater than or equal to 3 A/m) IEC 61000-4-8; IEC 61000-4-8:2009; EN 61000-4-8; EN 61000-4-8:2010 Pulse Magnetic Field IEC 61000-4-9; IEC 61000-4-9:1993 + A1:2000; EN 61000-4-9; EN 61000-4-9:1993 + A1:2001 Damped Oscillatory Magnetic Field IEC 61000-4-10; IEC 61000-4-10:1993 + A1:2000; EN 61000-4-10; EN 61000-4-10:1993 + A1:2001 AC Voltage Dips and Interruptions IEC 61000-4-11; IEC 61000-4-11:2004; EN 61000-4-11; EN 61000-4-11:2004 Ring Wave IEC 61000-4-12; IEC 61000-4-12:2017; EN 61000-4-12; EN 61000-4-12:2017 Harmonics and Interharmonics IEC 61000-4-13; IEC 61000-4-13:2002 +A1:2009 +A2:2015; EN 61000-4-13; EN 61000-4-13:2002 +A1:2009 +A2:2016 Power Frequency IEC 61000-4-16; IEC 61000-4-16:1998 + A2:2009; EN 61000-4-16; EN 61000-4-16:1998 + A2:2011 Ripple on DC Input Power Port IEC 61000-4-17; IEC 61000-4-17:1999 + A1:2001 + A2:2008; EN 61000-4-17; EN 61000-4-17:1999 + A1:2004 + A2:2009 Damped Oscillatory Wave IEC 61000-4-18; IEC 61000-4-18:2006 + A1:2010; EN 61000-4-18; EN 61000-4-18:2007 + Corr:2007 + A1:2010 DC Voltage Dips and Interruptions IEC 61000-4-29; IEC 61000-4-29:2000; EN 61000-4-29; EN 61000-4-29:2000
3IEC 60529; IEC 60529:1989/A1:1991/A2:2013; EN 60529; EN 60529:1991/A1:2000/A2:2013/AC:2019; IEEE C37.90; IEEE C37.90:2005; EN/IEC/UL 61010-1; CAN/CSA-C22.2 No. 61010-1-12; EN/IEC/UL 61010-2-201; EN 60825-1; EN 60825-1:2014; IEC 60825-1; IEC 60825-1:2014; IEC 60825-2; IEC 60825-2:2004 + A1:2006 + A2:2010; EN 60825-2; EN 60825-2:2004 + A1:2007 + A2:2010; IEC 60255-1; IEC 60255-1:2009; IEC 60255-1:2022; EN 60255-1; EN 60255-1:2010; EN 60255-1:2023; KS C IEC 60255-1:2019; IEC 60255-26; IEC 60255-26:2013; IEC 60255-26:2023; EN 60255-26; EN 60255-26:2013 + AC:2013; EN 60255-26:2025; KS C 60255-26:2020; IEC 60255-27; IEC 60255-27:2013; IEC 60255-27:2023; EN 60255-27; EN 60255-27:2014; EN 60255-27:2025; KS C 60255-27:2013; IEC 61000-6-2; IEC 61000-6-2:2005; EN 61000-6-2; EN 61000-6-2:2005; KS C 9610-6-2; IEC 61000-6-4; IEC 61000-6-4:2006 + A1:2010; EN 61000-6-4; EN 61000-6-4:2007 + A1:2011; KS C 9610-6-4--
4EN 61326-1; EN 61326-1:2013; IEC 61326-1; IEC 61326-1:2012; EN 61326-2-2; EN 61326-2-2:2013; IEC 61326-2-2; IEC 61326-2-2:2013; EN 61131-2; EN 61131-2:2007; IEC 61131-2; IEC 61131-2:2007; CISPR 35; CISPR 35:2016; EN 55035; EN 55035:2017; KS C 9835; IEEE 1613; IEEE 1613:2009; IEEE 1613.1; IEEE 1613.1:2013; IEC 61850-3; IEC 61850-3:2013; EN 61850-3; EN 61850-3:2014; IEC 61869-13:2021; EN 61869-13:2021; IEC 60255-1Electrical equipment for measurement, control and laboratory use; Programmable controllers; Multimedia equipment; Communications Networking Devices; Instrument Transformers-
5ANSI C63.4:2014Unintentional RadiatorsSee scope document
6ISO/IEC 17025:2017--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

A2LA

ISO/IEC 17025

Active

3354.02

The scope document we hold says it is valid until 2028-07-31.

View scope

Accredited scope, certificate 3354.02

LineMethodMatrixRange
1IEC 60255-21-1; IEC 60255-21-1:1988; EN 60255-21-1; EN 60255-21-1:1995; IEC 60255-21-2; IEC 60255-21-2:1988; EN 60255-21-2; EN 60255-21-2:1995; IEC 60255-21-3; IEC 60255-21-3:1993; EN 60255-21-3; EN 60255-21-3:1995; IEEE 1613; IEEE 1613:2009; IEC 60068-2-1; IEC 60068-2-1:2007; EN 60068-2-1; EN 60068-2-1:2007; IEC 60068-2-14; IEC 60068-2-14:2009; IEC 60068-2-14:2023; EN 60068-2-14; EN 60068-2-14:2009; IEC 60068-2-2; IEC 60068-2-2:2007; EN 60068-2-2; EN 60068-2-2:2007; IEC 60068-2-30; IEC 60068-2-30:2005; EN 60068-2-30; EN 60068-2-30:2005; IEC 60068-2-78; IEC 60068-2-78:2001; IEC 60068-2-78:2012; EN 60068-2-78; EN 60068-2-78:2001; EN 60068-2-78:2013protective relays; substation equipment and devices intended to operate with protective relays and substation equipment-
2ISO/IEC 17025:2017--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

2350 NE Hopkins Ct., Pullman, WA, 99163, US

46.73043, -117.17390

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.