SGS Analytics Sweden

Bromsgatan 4, 653 41, Karlstad, Sweden

SWEDAC|a001119-003ISO/IEC 17025Register collected 2026-08-22
Certificates
1
Scope items
7
Locations
10

Contact this laboratory

Visit website
054-21 30 77
Open SWEDAC register entry
Watch this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at SGS Analytics Sweden?

Claim this profile to keep it accurate.

Claim this profile

Register record

SWEDACCollected
a001119-003Active

Certificates and scope

1
SWEDAC

ISO/IEC 17025

Active

a001119-003

View on SWEDAC

Accredited scope, certificate a001119-003

DisciplineMethodMatrixRange
Biological TestingSS-EN ISO 6222 Fresh water Yes 2 No Total count of culturable micro-organisms 22; SS-EN ISO 6222 Drinking water Yes 2 No Fresh water Yes 2 No Total count of culturable micro-organisms 30; SS-EN ISO 6222 Fresh water Yes 2 No Total count of culturable micro-organisms 36; SS-EN ISO 6222; SS-EN ISO 6222 Drinking water Yes 2 No Fresh water Yes 2 No Changes in the scope of accreditation are in boldFresh water-
Biological TestingSS-EN ISO 7899-2 Drinking water Yes 2 No Fresh water Yes 2 No Sea water Yes 2 No Waste water/Leach water Yes 2 No Legionella SS-EN ISO 11731 Drinking water Yes 2 No Fresh water Yes 2 No Microfungi; SS-EN ISO 14189 Drinking water Yes 2 No Fresh water Yes 2 No Pseudomonas aeruginosa SS-EN ISO 16266 Drinking water Yes 2 No Fresh water Yes 2 No Salmonella SS-EN ISO 19250 Drinking water Yes 2 No Fresh water Yes 2 No Sea water Yes 2 No Waste water/Leach water Yes 2 No Slowgrowing bacteria 22; SS-EN ISO 6222; SS-EN ISO 10705-2 Waste water/Leach water Yes 2 No SS-EN ISO 10705-2; ISO 7899-2 Drinking water Yes 2 No Fresh water Yes 2 No Sea water Yes 2 No Waste water/Leach water Yes 2 No Legionella SS-EN ISO 11731 Drinking water Yes 2 No Fresh water Yes 2Drinking water-
Biological TestingSS-EN ISO 7027-1 Nephelometry Drinking water Yes 2 No Nephelometry Fresh water Yes 2 No Nephelometry Waste water/Leach water Yes 2 No Microbiological analysis Technical area Parameter Method Technique Material Flex Type of flex Field Molecular biology Legionella pneumophila; SS-EN ISO 9308-2 Drinking water Yes 2 No Fresh water Yes 2 No Escherichia coli SS 028167 Drinking water Yes 2 No Fresh water Yes 2 No Waste water/Leach water Yes 2 No SS 028167; SS-EN ISO 9308-1 Drinking water Yes 2 No SS-EN ISO 9308-2 Drinking water Yes 2 No Fresh water Yes 2 No Page 5; ISO 7027-1 Nephelometry Drinking water Yes 2 No Nephelometry Fresh water Yes 2 No Nephelometry Waste water/Leach water Yes 2; ISO 9308-2 Drinking water Yes 2 No Fresh water Yes 2 No Escherichia coli SS 028167 Drinking water Yes 2 No Fresh water Yes 2 No Waste water/Leach water Yes 2 No SS 028167Drinking water-
Chemical TestingSS-EN ISO/IEC 17025:2018 SGS Analytics Sweden AB Karlstad Accreditation number 1006 Karlstad A001119-003 Biological examinations Technical area Parameter Method Technique Material Flex Type of flex Field Water analysis Toxicitet; SS-EN ISO 11348-3; SS-EN ISO 9963-2; SS-EN ISO 11732 Flow analysis/Spectrom etry Drinking water Yes 2 No Flow analysis/Spectrom etry Fresh water Yes 2 No Flow analysis/Spectrom etry Waste water/Leach water Yes 2 No Biochemical oxygen demand; SS-EN ISO 5815-1/SS-EN ISO 5814 Electrode Fresh water Yes 2 No Electrode Waste water/Leach water Yes 2 No Page 1Fresh water-
Chemical TestingSS-EN ISO 7887; SS-EN 27888 Electrode Drinking water Yes 2 No Electrode Fresh water Yes 2 No Electrode Waste water/Leach water Yes 2 No Corrosive carbonic acid Std Methods 4500-CO2 Calculation Drinking water Yes 2 No Dry matter SS 028113 Gravimetry Waste water/Leach water Yes 2 No Kisel; SS-EN ISO 13395 Calculation Drinking water Yes 2 No Calculation Fresh water Yes 2 No Calculation Waste water/Leach water Yes 2 No Page 2; ISO 15705 Photometry Fresh water Yes 2 No Photometry Waste water/Leach water Yes 2; ISO 7887Fresh water-
Chemical TestingSS-EN ISO 13395 Flow analysis/Spectrom etry Drinking water Yes 2 No Flow analysis/Spectrom etry Fresh water Yes 2 No Flow analysis/Spectrom etry Waste water/Leach water Yes 2 No Nitrite nitrogen and nitrate nitrogen SS-EN ISO 13395 Flow analysis/Spectrom etry Fresh water Yes 2 No Flow analysis/Spectrom etry Waste water/Leach water Yes 2 No Nitrogen; SS-EN ISO 11905-1; SS-EN ISO 20236 Combustion Fresh water Yes 2 No Combustion Waste water/Leach water Yes 2 No Odour Inhouse method; SS-EN 25813 Titration Drinking water Yes 2 No Titration Fresh water Yes 2 No Titration Waste water/Leach water Yes 2 No Page 3; ISO 13395 Flow analysis/Spectrom etry Drinking water Yes 2 No Flow analysis/Spectrom etry Fresh water Yes 2 No Flow analysis/Spectrom etry Waste water/Leach water Yes 2 No Nitrite nitrogen and nitrate nitrogen SS-EN ISO 13395 Flow analysis/Spectrom etry Fresh water Yes 2 No Flow analysis/Spectrom etry Waste water/Leach water Yes 2Drinking water-
Chemical TestingSS-EN ISO 10523 Electrode Drinking water Yes 2 No Electrode Fresh water Yes 2 No Electrode Waste water/Leach water Yes 2 No Phosphate phosphorous SS-EN ISO 15681-2 Flow analysis/Spectrom etry Drinking water Yes 2 No Flow analysis/Spectrom etry Fresh water Yes 2 No Flow analysis/Spectrom etry Waste water/Leach water Yes 2 No Phosphorous; SS-EN ISO 15681-2 Flow analysis/Spectrom etry Fresh water Yes 2 No Flow analysis/Spectrom etry Waste water/Leach water Yes 2 No Sulfid SS 028115 Colorimetry Drinking water Yes 2 No Colorimetry Fresh water Yes 2 No SS 028117 Colorimetry Waste water/Leach water Yes 2 No Suspended solids SS-EN 872 Gravimetry Fresh water Yes 2 No Gravimetry Waste water/Leach water Yes 2 No Transmittans NS 9462 Photometry Drinking water Yes 2 No Photometry Fresh water Yes 2 No Page 4; ISO 10523 Electrode Drinking water Yes 2 No Electrode Fresh water Yes 2 No Electrode Waste water/Leach water Yes 2 No Phosphate phosphorous SS-EN ISO 15681-2 Flow analysis/Spectrom etry Drinking water Yes 2 No Flow analysis/Spectrom etry Fresh water Yes 2 No Flow analysis/Spectrom etry Waste water/Leach water Yes 2; ISO 15681-2 Flow analysis/Spectrom etry Fresh water Yes 2 No Flow analysis/Spectrom etry Waste water/Leach water Yes 2 No Sulfid SS 028115 Colorimetry Drinking water Yes 2 No Colorimetry Fresh water Yes 2 No SS 028117 Colorimetry Waste water/Leach water Yes 2 No Suspended solids SS-EN 872 Gravimetry Fresh water Yes 2 No Gravimetry Waste water/Leach water Yes 2 No Transmittans NS 9462 Photometry Drinking water Yes 2 No Photometry Fresh water Yes 2 No Page 4Drinking water-

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one.

Location

Bromsgatan 4, Karlstad, 653 41, SE

59.38881, 13.47770

Open in Maps

Other Locations

9 other sites in this organization

Accreditation data collected from the SWEDAC register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the SWEDAC entry linked above.