Mensor, LP
201 Barnes Drive, 78666, San Marcos, TX, United States
Visit website- Scope lines
- 4
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 4 scope lines.
A2LA certificate 2066.01 · 4 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | 0 to 100 V |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2066.01) Revised 02/11/2026 Page 2 of 3
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Resistance – Generate–
Generate
1 Ω
100 Ω
450 Ω
1 kΩ
45 kΩ
500 kΩ
1 MΩ
5.6 μΩ/Ω
550 μΩ/Ω
2.5 mΩ/Ω
5.5 mΩ/Ω
460 mΩ/Ω
7.5 Ω/Ω
15 Ω/Ω
Ohm Labs Multiple
Resistance Standard
(MRS) – Fixed Range
Resistors
II. Mechanical
Parameter/Equipment
Range
CMC
2, 4, 6 (±)
Comments
Pressure – Gauges,
Controllers, & Transducers
Gauge, Pneumatic
Absolute, Pneumatic
Absolute/Gage, Pneumatic
Absolute/Gauge,
Hydraulic
(-370 to -93) kPa
(-93 to 0) kPa
(0 to 172) kPa
(0 to 172) kPa
(172 to 6900) kPa
(6.9 to 55) MPa
(55 to 103) MPa
(1 to 207) MPa
(207 to 500) MPa
0.0017 %
0.000 91 % + 7 mPa
0.000 86 % + 9.5 mPa
0.000 91 % + 35 mPa
0.0012 %
0.0019 %
0.0021 %
0.0028 %
0.0072 %
Fluke CPC6050
Dual Ruska DWTs
Ruska DWTs
Ruska DWTs
DHB DWTs
DHB DWTs
Fluke DWTs
DHB DWTs
DHB DWTs
Mass – Measure
Up to 1 kg
(1 to 10) kg
0.24 mg
2.5 mg
Reference mass set
and Mettler balance
III. Thermodynamics
Parameter/Equipment Range CMC 2, 4 (±) Comments
Temperature – Measuring
Equipment
(-40 to 420) °C
0.057 °C
PRT
____________________________________________ | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2066.01) Revised 02/11/2026 Page 3 of 3
1 Commercial calibration service is available for this laboratory.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 This scope meets A2LA’s P112 Flexible Scope Policy.
4 The type of instrument or material being calib rated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
5 The stated measured values are determined usi ng the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a
fraction/percentage of the reading plus a fixed floor specification.
6 In the statement of CMC, percentages are percentages of reading, unless otherwise indicated. | ||
| 4 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- NI Global Calibration Services dba NI Calibration Services AustinAustin, TX · ~46 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- ETS LindgrenCedar Park, TX · ~72 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Southwest Research InstituteSan Antonio, TX · ~74 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- G.T. MICHELLI CO., LLC - HOUSTONHouston, TX · ~249 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Technology & Calibration, Inc. dba Tech CalHouston, TX · ~249 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.