Registers refreshed 2026-11-20.See refresh dates
Canada

North American EMC Certification Services

Maple Ridge, Canada

Visit website
A2LA 4812.01A2LA 4812.02ISO/IEC 17025ISO/IEC 17065Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
3
A2LA certificates
2
Sites in our directory
3
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 3 standard numbers and the 2 official names we hold. When no standard matches, it searches the method text of every scope line.

ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ANSI C63.26
FCC PART 15Radio Frequency Devices

Read from the A2LA scope documents we downloaded on 2026-08-05 and 2026-10-27. Register refreshed 2026-11-20.

Scope as published by A2LA

7 lines
A2LA

ISO/IEC 17025

Active

4812.01

The scope document we hold says it is valid until 2028-05-31.

View scope

Accredited scope, certificate 4812.01

LineMethodMatrixRange
1ANSI C63.4:2014; ANSI C63.10:2013; ANSI C63.17:2013; 47 CFR FCC Part 15, Subpart B; 47 CFR FCC Part 15, Subpart C; 47 CFR FCC Part 15, Subpart D; 47 CFR FCC Part 15, Subpart E; 47 CFR FCC Part 15, Subpart F; 47 CFR FCC Part 15, Subpart G; 47 CFR FCC Part 15, Subpart H; 47 CFR FCC Part 18; FCC MP-5:1986; ANSI C63.10 :2020+Cor. 1 :2023+C63.10a :2024 + Errata to C63.10a:2024; ICES-001; ICES-003; ICES-006; RSS-102; RSS-102.NS.MEAS; SPR-002; RSS-111; RSS-112; RSS-117; RSS-119; RSS-123; RSS-125; RSS-127; RSS-130; RSS-131; RSS-132; RSS-133; RSS-134; RSS-135; RSS-137; RSS-139; RSS-140; RSS-141; RSS-142; RSS-170; RSS-181; RSS-182; RSS-191; RSS-192; RSS-193; RSS-194; RSS-195; RSS-196; RSS-197; RSS-198; RSS-199; RSS-210; RSS-211; RSS-213; RSS-215; RSS-216; RSS-220; RSS-222; RSS-236; RSS-238; RSS-243; RSS-244; RSS-246; RSS-247; RSS-248; RSS-251; RSS-252; RSS-287; RSS-288; RSS-310; RSS-GEN; BETS-1; BETS-3; BETS-4; BETS-5; BETS-6; BETS-7; BETS-8; BETS-9; ISO/IEC 17025:2017-See scope document
2ANSI C63.26:2015; ANSI/TIA-603-E; TIA-102.CAAA-E; 47 CFR FCC Part 22, 24, 25, and 27 (using ANSI C63.26:2015); 47 CFR FCC Part 22, 90, 95, 97, and 101 (using ANSI C63.26:2015); 47 CFR FCC Part 96 (using ANSI C63.26:2015); 47 CFR FCC Parts 80 and 87 (using ANSI C63.26:2015); 47 CFR FCC Parts 25, 30, 74, 90, and 101 (using ANSI C63.26:2015); 47 CFR FCC Parts 73 and 74 (using ANSI C63.26:2015); 47 CFR FCC Part 20 (using ANSI C63.26:2015); ANSI C63.4:2014; FCC MP-5 (February 1986); ANSI C63.10:2020+Cor. 1:2023; ANSI C63.17:2013; FCC KDB 905462 D02 (v02), April 4, 2016Receiver; Keyboard; Information Technology Equipment (ITE); Multimedia Equipment; WLAN Devices (with or without DFS); Household Appliances; Industrial Science and Medical (ISM) Equipment; Maritime Navigation Equipment; Airborne Equipment; Cellphones; PCS Equipment; Radio Communications & Telecommunications Equipment; Broadcasting Equipmentto 110000 MHz
3ANSI C63.26:2015-to 110000 MHz
4ISO/IEC 17025:2017--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

A2LA

ISO/IEC 17065

Active

4812.02

The scope document we hold says it is valid until 2028-05-31.

View scope

Accredited scope, certificate 4812.02

LineMethodMatrixRange
1ISO/IEC 17065:2012--
247 CFR Parts 22; 47 CFR Parts 73; 47 CFR Parts 74; 47 CFR Parts 90; 47 CFR Parts 95; 47 CFR Parts 97; 47 CFR Parts 101; 47 CFR Parts 80; 47 CFR Parts 87; 47 CFR Parts 25; 47 CFR Parts 30; 47 CFR Parts 95L; 47 CFR Parts 95M; 47 CFR Parts 96--
3ISO/IEC 17065:2012; A2LA R308--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Other Locations

2 other sites in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.