Electronics Test Centre - Airdrie (MPB Technologies Inc.)
Airdrie, Canada
Visit website- Accredited standards
- 87
- A2LA certificates
- 2
- Sites in our directory
- 3
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 87 standard numbers and the 58 official names we hold. When no standard matches, it searches the method text of every scope line.
ETSI25
ETSI EN 300 019-2-1
ETSI EN 300 019-2-2
ETSI EN 300 019-2-3
ETSI EN 300 019-2-4
ETSI EN 300 132-1
ETSI EN 300 132-2
ETSI EN 300 220-1
ETSI EN 300 220-2
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 330Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 300 386
ETSI EN 300 440
Show all 25
ETSI EN 300 487
ETSI EN 301 489-1
ETSI EN 301 489-2
ETSI EN 301 489-3
ETSI EN 301 489-5
ETSI EN 301 489-7
ETSI EN 301 489-17
ETSI EN 301 489-19
ETSI EN 301 893
ETSI EN 301 908-1
ETSI EN 302 502
ETSI EN 303 413Satellite Earth Stations and Systems (SES); Global Navigation Satellite System (GNSS) receivers; Radio equipment operating in the 1 164 MHz to 1 300 MHz and 1 559 MHz to 1 610 MHz frequency bands; Harmonised Standard for access to radio spectrum
ETSI EN 303 417
IEC 61000 series15
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-4-17
IEC 61000-4-22
IEC 61000-4-29Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
IEC 61000-4-32
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
IEC 60068 series12
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-11Environmental testing - Part 2-11: Tests - Test Ka: Salt mist
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-18
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-31Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens
IEC 60068-2-52Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution)
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance
IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
ISO7
ISO 9022-2Optics and photonics - Environmental test methods - Part 2: Cold, heat and humidity
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
ISO 13766-1Earth-moving and building construction machinery - Electromagnetic compatibility (EMC) of machines with internal electrical power supply - Part 1: General EMC requirements under typical electromagnetic environmental conditions
ISO 14982Agricultural and forestry machinery - Electromagnetic compatibility - Test methods and acceptance criteria
ISO 20653Road vehicles - Degrees of protection (IP code) - Protection of electrical equipment against foreign objects, water and access
CISPR6
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurement
CISPR 25Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of on-board receivers
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirementsExclusion
Limits written next to it
EN 55035 (excluding xDSL-specific req.)
EN6
EN 12015Electromagnetic compatibility - Product family standard for lifts, escalators and moving walks - Emission
EN 12016
EN 50121-3
EN 50121-4Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus
EN 50155Railway applications - Rolling stock - Electronic equipment
EN 50498Electromagnetic compatibility (EMC) - Product family standard for aftermarket electronic equipment in vehicles
IEC6
IEC 16750-4
IEC 60529Degrees of protection provided by enclosures (IP Code)
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 60945Maritime navigation and radiocommunication equipment and systems - General requirements - Methods of testing and required test results
IEC 61326-2-6Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical electrical equipment
IEC 61373Railway applications - Rolling stock equipment - Shock and vibration tests
ISO 16750 series3
ISO 16750-2Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads
ISO 16750-3Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 3: Mechanical loads
ISO 16750-4Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 4: Climatic loads
ISO 7637 series3
ISO 7637-1Road vehicles - Electrical disturbances from conduction and coupling - Part 1: Vocabulary and general considerations
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
Other standards4
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ASTM B117Standard Practice for Operating Salt Spray (Fog) Apparatus
FCC PART 15Radio Frequency Devices
ICES-001Industrial, Scientific and Medical (ISM) Equipment
ASAE EP455 Section 5.15; IEC 60945 Section 8.73; MIL-STD-810 Section 514; MIL-STD-167-1A3; RTCA/DO-160 Section 8; UN Section 38.3.4.3; ISO 16750-3; IEC 60068-2-64; IEC 60068-2-6; EN 61373; SAE J1455 Sections 4.10.4.1, 4.10.4.2; GR-63 Sections 5.4.2, 5.4.3; GR-3108 Section 6.1.3.5, 6.3.3; ETSI EN 300-019-2-1; ETSI EN 300-019-2-2; ETSI EN 300-019-2-3; ETSI EN 300-019-2-4; ASAE EP455 Section 5.14; MIL-STD-810 Section 516; RTCA DO-160 Section 7 Procedure I; CLAAS CN 050215; ISO 16750-3; EN 61373; IEC 60068-2-27; ETSI EN 300-019-2-1; ETSI EN 300-019-2-2; ETSI EN 300-019-2-3; ETSI EN 300-019-2-4; GR-3108 Section 6.3.1.3
MIL-STD-810 Section 516; IEC 60945 Section 8.6.1; ISO 16750-3 Section 4.3; IEC 60068-2-31; SAE J1455 Sections 4.11.3.1, 4.11.3.2; GR-63 Section 5.3; GR-3108 Section 6.3.1.2, 6.1.3.4; ETSI EN 300-019-2-2; MIL-STD-810 Section 514; UN Section 38.3.4.4; IEC 60068-2-27; ASAE EP455 Sections 5.2.1, 5.2.2; MIL-STD-810 Section 500; RTCA DO-160 Section 4.6; UN Section 38.3.4.1; IEC 60529 IP5X; IEC 60529 IP6X; ISO 16750-4 Section 5.11; ISO 20653; CLAAS CN 050215; ASAE EP 455 Sections 5.1.1, 5.1.2; IEC 60945 Sections 8.2, 8.4; MIL-STD-810 Sections 501, 502; RTCA/DO-160 Sections 4, 5; CLAAS CN 050215 Sections 3.2, 3.4; IEC 60068-2-1; IEC 60068-2-2; ISO 9022-2 Sections 4.2.2, 4.2.3, 4.3.2; UN Section 38.3.4.2; ISO 16750-4 Section 5.2; SAE J1455 Section 4.1.3.1; GR-63 Section 5.1.2, 5.1.3; GR-63 Section 5.1.4, 5.1.5, 5.1.7; ETSI EN 300-019-2-1; ETSI EN 300-019-2-3; ETSI EN 300-019-2-4; ATPD-2167 Section 3.1
ASAE EP 455 Section 5.1.3; IEC 60945 Section 8.5; MIL-STD-810 Section 503; CLAAS CN 050215 Section 3.3; IEC 60068-2-14; ISO 9022-2 Section 4.3.3; ISO 16750-4 Section 5.3; SAE J1455 Section 4.1.3.2; GR-63 Section 5.1.1.1, 5.1.1.3; GR-3108 Section 4.4; ASAE EP 455 Sections 5.13.1, 5.13.2; IEC 60945 Section 8.3; MIL-STD-810 Section 507; RTCA/DO-160 Section 6; IEC 60068-2-30; IEC 60068-2-78; ISO 9022-2 Sections 4.2.4, 4.3.4; CLAAS CN050215 Section 3.4.1; ISO 16750-4; SAE J1455 Section 4.2; GR-63 Section 5.1.1.2, 5.1.2; GR-3108 Section 4.4, 4.6; ETSI EN 300-019-2-1; ETSI EN 300-019-2-2; ETSI EN 300-019-2-3; ETSI EN 300-019-2-4; ATPD-2167 Section 3.4; ASAE EP455 Section 5.5; MIL-STD-810 Section 512; NEMA 250 Section 5.11; IEC 60529; IPX7; IPX8; IEC 16750-4 Section 5.4.3; ISO 20653; IPX7; IPX8; IEC 60068-2-18 method Rc 1
ASAE EP455 Section 5.6; NEMA 250 Section 5.4; NEMA 250 Section 5.5.1.3; NEMA 250 Section 5.7; IEC 60529 IPX1; IEC 60529 IPX2; IEC 60529 IPX3; IEC 60529 IPX4; IEC 60529 IPX5; IEC 60529 IPX6; RTCA DO-160 Section 10 Cat. 10.3.1; RTCA DO-160 Section 10.3.2; RTCA DO-160 Section 10.3.4; MIL-STD-810 Section 506 Procedure 3; ISO 20653 IPX1; ISO 20653 IPX2; ISO 20653 IPX3; ISO 20653 IPX4; ISO 20653 IPX5; ISO 20653 IPX6; IEC 60945 Section 8.8; IEC 60068-2-18 method Ra 2; IEC 60068-2-18 method Rb 1.2; IEC 60068-2-18 method Rb 2; ETSI EN 300-019-2-1; ETSI EN 300-019-2-2; ETSI EN 300-019-2-4; ISO 20653 IPX9K; SAE J1455 Section 4.5; IEC 60529 IPX9K; NEMA 250 Section 5.15; IEC 60068-2-18 method Rb 3; IEC 60945 Section 12.1; ISO 20653 IP1X; ISO 20653 IP2X; ISO 20653 IP3X; ISO 20653 IP4X; IEC 60529 IP1X; IEC 60529 IP2X; IEC 60529 IP3X; IEC 60529 IP4X; MIL-STD-810 Section 509; ISO 16750-4; IEC 60068-2-52; IEC 60945 Section 8.12; SAE J1455 Section 4.3.3.1; ASAE EP455 Section 5.9; RTCA DO-160 Section 14; ASTM B117; NEMA 250 Section 5.8; NEMA 250 Section 5.9.1; NEMA 250 Section 5.10; GR-3108 Section 6.2; IEC 60068-2-11; ETSI EN 300-019-2-4; NEMA 250 Section 5.6; RTCA DO-160 Section 24 Cat. A; RTCA DO-160 Section 24 Cat. C; MIL-STD-810 Section 521; UN Section 38.3.4.6; UN Section 38.3.4.8; UN Section 38.3.4.7
EN 61000-3-2; IEC 61000-3-2; EN 61000-3-3; IEC 61000-3-3; EN 61000-4-22; IEC 61000-4-22; ISO 14982; CLAAS CN 050215; ISO 10605; SAE J1113 13; EN 61000-4-32; IEC 61000-4-32; ISO 11452-2; ISO 11452 5; IEEE C37.90.2; EN 61000-4-4; IEC 61000-4-4; EN 61000-4-5; IEC 61000-4-5; EN 61000-4-62; IEC 61000-4-62; ISO 11452-4; SAE J1113-4; EN 61000-4-8; IEC 61000-4-8; EN 61000-4-112; IEC 61000-4-112; EN 61000-4-29; IEC 61000-4-29; ETSI EN 300 132-1; ETSI EN 300 132-2; IEC 61000-4-17; EN 61000-4-17; ISO 7637-1:1990; ISO 7637-2:1990, 2004, 2011; ISO 7637-3:2007, 2014; ISO 16750-2; SAE J1113-11; SAE J1113-12; RTCA/DO-160 D, E, F, G Section 15; RTCA/DO-160 D, E, F, G Section 16; RTCA/DO-160 D, E, F, G Section 17; RTCA/DO-160 D, E, F, G Section 18; RTCA/DO-160 D, E, F, G Section 19; RTCA/DO-160 D, E, F, G Section 20
47 CFR FCC Part 15B (using ANSI C63.4:2014); 47 CFR FCC Part 18 (using FCC/OET MP-5:1986); ICES-001; ICES-003; ICES-005; CISPR 11; EN 55011; CISPR 22; EN 55022; CISPR 25; EN 55025; CISPR 32; EN 55032; IEC 60945; 47 CFR FCC Part 15C (using ANSI C63.10:2013); 47 CFR FCC Part 15E (using ANSI C63.10:2013); 47 CFR FCC Parts 22 (noncellular), 24 (below 3 GHz), 25 (below 3 GHz), 27 and 90 (using ANSI C63.26:2015); 47 CFR FCC Parts 22 (non cellular), 90 (below 3GHz), 95 (below 3 GHz), 97 (below 3 GHz) and 101 (below 3 GHz) (using ANSI C63.26-2015); RSS-GEN; RSS-119; RSS-132; RSS-133; RSS-134; RSS-139; RSS-170; RSS-210; RSS-215; RSS-216; RSS 247; ETSI EN 300 220-1; ETSI EN 300 220-2; ETSI EN 300 328; ETSI EN 300 440; ETSI EN 300 487; ETSI EN 301 893; ETSI EN 302 502; ETSI EN 303 413; ETSI EN 300 330; ETSI EN 301 908-1; ETSI EN 303 417
EN 61000-6-3; IEC 61000-6-3; EN 61000-6-4; IEC 61000-6-4; EN 50121-4; EN 50121-3; EN 50155; EN 50498; EN 12015; EN 12016; ETSI EN 300 386; ETSI EN 301 489-1; ETSI EN 301 489-2; ETSI EN 301 489-3; ETSI EN 301 489-5; ETSI EN 301 489-7; ETSI EN 301 489-17; ETSI EN 301 489-19; UN ECE R10.06; GR-3108; ISO 16750-2
MIL-STD-461F CE101; CE102; RE101; RE102; RS101; RS103; CS101; CS106; CS114; CS115; and CS116; MIL-STD-461G CE101; CE102; RE101; RE102; RS101; RS103; CS101; CS114; CS115; CS116; and CS118; MIL-STD-1399 300-Part 1 Table 1- Type I 60 Hz Single phase, 115Vrms; MIL-STD-1275E Sections 5.3.1.1; 5.3.1.2; 5.3.2; 5.3.3.1.2; 5.3.3.2.1; 5.3.3.2.2; and 5.3.4; GR-1089 Section 2.1 ESD; Section 2.2 EFT; Section 3.2 Emission; Section 3.3 Immunity; Section 4 Lightning; Section 6 DC Potential Difference; Section 7 Electrical and Optical Safety; Section 8 Corrosion; Section 9 Bonding and Grounding; Section 10 DC Power Port; ATIS-0600315 :2007; CISPR 24; CISPR 35; EN 55024; EN 55035; CISPR 25 Section 6; EN 55025 Section 6; EN 60601-1-2; IEC 61326; EN 61326; ISO 14982 Section 6;; EN ISO 13766-1 Sections 4.5, 4.6, 4.7, and 4.8; IEC 60945; EN 61000-6-1; IEC 61000-6-1; EN 61000-6-2; IEC 61000-6-2
ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2013; ANSI C63.26:2015
Read from the A2LA scope documents we downloaded on 2026-03-14 and 2026-10-27. Register refreshed 2026-11-20.
Scope as published by A2LA
12 lines
ISO/IEC 17025
Active2750.01
The scope document we hold says it is valid until 2026-11-30.
ISO/IEC 17025
Active2750.02
The scope document we hold says it is valid until 2026-11-30.
Other Locations
2 other sites in this organization
Labs with overlapping accredited scope in Canada
- Stancer Testing-LabLavalA2LAShares 2 accredited test methodsANSI C63.4:2014CISPR 24
- Element Materials Technology KitchenerKitchenerA2LAShares 1 accredited test methodIEC 60068-2-27
- Element Materials Technology MontréalChamblyA2LAShares 1 accredited test methodISO 16750-3
- Labtest CertificationDeltaA2LAShares 1 accredited test methodANSI C63.4:2014
- North American EMC Certification ServicesMaple RidgeA2LAShares 1 accredited test methodANSI C63.4:2014
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.