Registers refreshed 2026-11-20.See refresh dates
United States

Schap Laboratory Services

17309 Taft Road, Unit 5, 49456, Spring Lake, MI, United States

Visit website
A2LA 3611.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
13
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 13 standard numbers and the 7 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO6
ISO 105-X12Textiles - Tests for colour fastness - Part X12: Colour fastness to rubbing
ISO 5402Leather - Physical and mechanical tests - Determination of flex resistance by flexometer methodExclusion

Limits written next to it

ISO 5402 (Except Wet)

Exclusion. Written next to it on line 1 of A2LA certificate 3611.01.

ISO 6452Rubber- or plastics-coated fabrics - Determination of fogging characteristics of trim materials in the interior of automobiles
ISO 11640Leather - Tests for colour fastness - Colour fastness to cycles of to-and-fro rubbingExclusion

Limits written next to it

Veslic Colorfastness ISO 11640 (Except Sec

Exclusion. Written next to it on line 2 of A2LA certificate 3611.01.

ISO 17071Leather - Physical and mechanical tests - Determination of fogging characteristics
ISO 32100Rubber- or plastics-coated fabrics - Physical and mechanical tests - Determination of flex resistance by the flexometer method
ASTM5
ASTM D523Standard Test Method for Specular Gloss
ASTM D2097
ASTM D3776
ASTM D4157
ASTM D6182
Other standards2
AATCC 8
DIN 75201

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

5 lines
A2LA

ISO/IEC 17025

Active

3611.01

The scope document we hold says it was valid until 2026-06-30. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.

View scope

Accredited scope, certificate 3611.01

LineMethodMatrixRange
1ASTM D6182; ISO 5402; ISO 32100; TSL 5101G; ASTM D2097; Ford FLTM BN 102-02; JIS L0849; L1084; Nissan M0154; M0155; M0602; TSL 5100G; 5101G; HONDA 8102Z-TLA-G100 B 6-2-3Textile-
2ASTM D4157; GM9082P; SAE J948; SAE J1530; TSL 5101G; ISO 11640; GMW 3208; MS 300-31; NES M0602; 8102Z-TLA-G100; AATCC 8; ISO 105-X12; ASTM D3776; GMW 3182; MS 300-31; NES M0602; TSL 5101G; GM 2756M; TL 52064; TSL 5101G; NES M0602; 8102Z-SZN-G100; ASTM D523; AATCC-1; ISO-105-A02; TL 52064; PV 1200; WSS-M99P43-E1; WSS-M99P43-E2; Nissan M0602; GMW3262; GMW14124; TL 52064; SAE J1756; GMW3235; LP-463DB-12-01; TSM0503; PV 3010; DIN 75201; DIN EN ISO 17071; MS 300-54; NES M0161; HES D6508; ISO 6452--
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3611.01) 07/16/2024 Page 3 of 4 CALIBRATION7,8 I. Dimensional Testing/Calibration Parameter/Equipment Range CMC3, 6 (±) Comments Length 1D4,5 – Measure Up to 304mm 0.15 mm Caliper II. Mechanical Parameter/Equipment Range CMC3, 6 (±) Comments Mass – Measure4 Up to 2 kg (2 to 200) kg 0.15 g 0.17 kg Scales Force – Measure5 Up to 88 N 0.38 N Force gage Speed – Measure4 (5 to 99 999) RPM 0.34 RPM Tachometer III. Thermodynamic Parameter/Equipment Range CMC3, 6 (±) Comments Temperature – Measure (0 to 110) °C 0.027 °C Fluke 1560 and thermistor probes IV. Time and Frequency Parameter/Equipment Range CMC3, 6 (±) Comments Speed – Measure4 5-60 seconds 0.14 s Bench timer __________________
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3611.01) 07/16/2024 Page 4 of 4 1 The laboratory is only accredited for the test methods listed. The accredited test methods are used in determining compliance with the material specifications listed below. The inclusion of these material specifications on this Scope does not confer labor atory accreditation to the material specifications nor does it confer accreditation for the method(s) embedded within the specifications. 2 This laboratory’s scope contains withdrawn or superseded methods. As a clarifier, this indicates that the applicable method itself has been withdrawn or is now considered “historical” and not that the laboratory’s accreditation for the method has been withdrawn. 3 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 4 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 5 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for the types of dimensional tests listed above and is considered equivalent to that of a calibration certificate. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 7 This scope meets A2LA’s P112 Flexible Scope Policy. 8 This laboratory offers commercial dimensional testing and commercial and field calibration services where noted.
5

Extracted from the scope document; tables may not line up. View scope for the original.

For the types of tests and calibrations to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation. Accredited Laboratory A2LA has accredited SCHAP LABORATORY SERVICES, LLC Spring Lake, MI for technical competence in the field of Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 16th day of July 2024. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 3611.01 Valid to June 30, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

17309 Taft Road, Unit 5, Spring Lake, MI, 49456, US

43.07696, -86.19700

Open in Maps

Accreditation data refreshed from the A2LA register on .