Studio Sperimentale Metalsiderurgico SSM
Via degli Artigiani, 86, 16162, Bolzaneto, Italy
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Studio Sperimentale Metalsiderurgico SSM?
Claim this profile to keep it accurate.
Register record
- ACCREDIARefreshed
- 00874Active
Certificates and scope
1ISO/IEC 17025
Active00874
Accredited scope, certificate 00874
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | materials | ASTM E415-21; ASTM E1086-22; UNI EN 10164:2018; ASTM E381-22; UNI EN ISO 17638:2016; UNI EN ISO 9015-1:2011; ASME BPVC IX QW 290.5:2025; ASME BPVC IX QW 183:2025; ASME BPVC IX QW 184:2025; UNI EN ISO 17639:2022; UNI EN ISO 17637:2017; UNI EN ISO 5173:2023; ASME BPVC IX QW 160:2025; UNI EN ISO 9016:2022 + UNI EN ISO 148-1:2016; ASME BPVC IX QW 170:2025; ASME BPVC IX QW 150:2025; UNI EN ISO 5178:2019 + UNI EN ISO 6892-1:2020; UNI EN ISO 4136:2022 + UNI EN ISO 6892-1:2020; ASME BPVC IX QW 150:2025 | Acciai basso legati/Low alloy steels; Acciai/Steels; Acciai inossidabili austenitico/Austenitic stainless steels; Acciai inossidabili non austenitici (1)/Non austenitic stainless (1); Acciai/Steels; Barre d'acciaio/Steel bars; Billette /Billets; Blumi/Blooms; Fucinati/Forgings; Giunti saldati di materiali metallici/Welds of metallics materials; Leghe metalliche/Metallic alloys; Materiali metallici/Metallic material | - |
| 2 | materials | UNI 3137:1965; UNI EN ISO 3452-1:2021; UNI EN ISO 6506-1:2015; ASTM E10-23; UNI EN ISO 6507-1:2023; ASTM E92-23; ASTM E3-11(2025); ASTM E340-23; UNI EN ISO 148-1:2016; ASTM E23-25; ASTM A370-24a; ASTM E8/E8M-25; UNI EN ISO 6892-1:2020; ASTM A370-24a + ASTM E8/E8M-25 | Metal | 0 to 450 J |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Italy
- L.P.M. S.N.C. DI MOLINARI VINCENZO E C.Gragnano Trebbiense · ~81 kmACCREDIAShares 3 accredited methods and materialsASTM E10-23ASTM E415-21Metal
- C.T.S. Centro Tecnologico SperimentaleCeparana di Bolano · ~85 kmACCREDIAShares 3 accredited methods and materialsASTM E10-23ASTM E415-21Metal
- BYTEST s.r.l.Volpiano · ~119 kmACCREDIAShares 3 accredited methods and materialsASTM E10-23ASTM E415-21Metal
- Laboratorio T.O.S.I.Legnano · ~126 kmACCREDIAShares 3 accredited methods and materialsASTM E10-23ASTM E415-21Metal
- MTC s.r.l.Rosta · ~132 kmACCREDIAShares 3 accredited methods and materialsASTM E10-23ASTM E415-21Metal
Accreditation data refreshed from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.