Registers refreshed 2026-11-20.See refresh dates
United States

Smithers - MSE Product Testing

425 West Market Street, 44303, Akron, OH, United States

Visit website
A2LA 6550.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
9
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 9 standard numbers and the 5 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM D380
ASTM D751
ASTM D2803
DIN 73411-2
ISO 1402Rubber and plastics hoses and hose assemblies - Hydrostatic testing
ISO 6803Rubber or plastics hoses and hose assemblies - Hydraulic-pressure impulse test without flexing
ISO 6945Rubber hoses - Determination of abrasion resistance of the outer cover
ISO 19879Metallic tube connections for fluid power and general use - Test methods for hydraulic fluid power connections
ISO 21507Earth-moving machinery - Performance requirements for non-metallic fuel tanks

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

3 lines
A2LA

ISO/IEC 17025

Active

6550.01

The scope document we hold says it is valid until 2028-03-31.

View scope

Accredited scope, certificate 6550.01

LineMethodMatrixRange
1-military, aerospace, automotive, medical, industrial, metals, plastics, rubber, electrical/electronic products and/or assemblies
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6550.01) Revised 03/03/2026 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 SMITHERS – MSE PRODUCT TESTING 425 West Market Street Akron, OH 44303-2088 Jeff Andrasik Phone: 330 762 7441 MECHANICAL Valid To: March 31, 2028 Certificate Number: 6550.01 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following tests on military, aerospace, automotive, medical, industrial, metals, plastics, rubber, electrical/electronic products and/or assemblies Using the following capabilities: Parameter1 Range Pressure Up to 20,000 psi Pressure Cycling Up to 8,000 psi Vacuum (0 to -26) in Hg Vibration Displacements Up to 6 in peak to peak Vibration Frequencies Up to 2,500 Hz Static & Dynamic Force Up to 10,000 lbs Acceleration Up to 50 g Temperature (-70 to 232) °C Temperature Cycling (-70 to 205) °C Humidity (10 to 95) % RH Air Flow Measurement (0.1 to 500) sccm Mechanical/Impact Shock Up to 2,000 g Thermal Shock (-65 to 200) ºC 1Also using customer specific test methods utilizing any combination of test equipment parameters listed above. 2The laboratory is only accredited for the properties listed above. The accredited properties are used in determining compliance with the product specifications listed below. The inclusion of these product specifications on this Scope does not confer laboratory accreditation to the product specifications.
-
2ASTM D380; ASTM D2803; ASTM D751; BMW DIN 73411-2; CS.00056; ESDG93-8260-AA; ESBB53-6C646-AA; ESBR33-9R504-AA; FMVSS 106; GMW16153; GMW14785; GMW16295; GMW15024; GMW16171; GMW14319; GMW14329; GMW18152; GMW15311; ISO 6803; ISO 6945; ISO 19879; ISO 1402; ISO 21507; MIL-STD-883 (Method 2005.2); MIL-DTL-24136; PF.90088; PF.90315; PF.90303; PF.11339; PF.90331; PF.90112; PF.12280; PF.90080; PF.90015; PF.90154; PF.90197; PF.90051; SAE J343; SAE J1610; SAE J2044; SAE J2030; SAE J1532; SAE J30; SAE J1942; SAE J2494-3; SAE J1131; SAE J188; SAE J2045; SAE J3062; SAE J517; SAE J2657; SAE J1205; SAE J1206; TR 22877313; TR 23775899; USCAR 21; USCAR 2; USCAR 38; USCAR 45--
3

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation. Accredited Laboratory A2LA has accredited SMITHERS – MSE PRODUCT TESTING Akron, OH for technical competence in the field of Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 18th day of February 2026. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 6550.01 Valid to March 31, 2028

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

425 West Market Street, Akron, OH, 44303, US

41.08306, -81.51848

Open in Maps

Other Locations

1 other site in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.