6721 Edith Blvd NE, Suite C, 87113, Albuquerque, NM, United States

Visit website
A2LA 1892.02ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
17
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 17 scope lines.

A2LA certificate 1892.02 · 17 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-to 8 in
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.02) 07/05/2024 Page 2 of 16 Parameter/Equipment Range CMC2, 4 (±) Comments Micrometers 3 – Depth Micrometers ID Micrometers OD Micrometers Up to 6 in (6 to 12) in Up to 8 in (8 to 16) in (16 to 24) in (24 to 32) in (32 to 40) in Up to 8 in (8 to 16) in (16 to 24) in (24 to 32) in (32 to 40) in 29 µin + 1.6 µin/in 8.8 µin + 4.4 µin/in 58 µin + 1 µin/in 49 µin + 2.3 µin/in 48 µin + 2.3 µin/in 43 µin + 2.6 µin/in 32 µin + 2.9 µin/in 28 µin + 1.3 µin/in 19 µin + 3.1 µin/in 33 µin + 1 µin/in 22 µin + 2.9 µin/in 24 µin + 3.2 µin/in Gage blocks Pin Gauges/Plug Gages (0.011 to 0.060) in (0.061 to 0.250) in (0.251 to 0.500) in (0.501 to 0.625) in (0.626 to 1.000) in (1.000 to 4.000) in (24 + 0.1D) µin (24 + 0.1D) µin (24 + 0.1D) µin (24 + 0.1D) µin (24 + 0.3D) µin (24 + 1D) µin Supermicrometer TM Thread Plug Gages – (Pitch & Major Diameter) Up to 6 in Major Diameter Pitch Diameter (21 + 1.4D) µin (120 + 1.9D) µin Supermicrometer TM, thread wires
to 40 in
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.02) 07/05/2024 Page 3 of 16 II. Electrical – DC/Low Frequency Parameter/Range Range CMC2, 5, 6 (±) Comments Oscilloscopes 3 – Square Wave Signal 10 Hz to 10 kHz 50 Ω Impedance 1 MΩ Impedance Level Sine Wave Flatness – 50 kHz Ref 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz 600 MHz to 1.1 GHz (1 to 24.999) mV p-p (25 to 109.999) mVp-p (0.11 to 2.1999) Vp-p (2.2 to 6.6) Vp-p (1 to 24.999) mVp-p (25 to 109.999) mVp-p (0.11 to 2.1999) Vp-p (2.2 to 10.999) Vp-p (11 to 130) Vp-p Up to 10 mV (10 to 40) mV (40 to 400) mV (0.4 to 1.3) V (1.3 to 5.5) V Up to 10 mV (10 to 40) mV (40 to 400) mV (0.4 to 1.3) V (1.3 to 5.5) V Up to 10 mV (10 to 40) mV (40 to 400) mV (0.4 to 1.3) V (1.3 to 5.5) V Up to 10 mV (10 to 40) mV (40 to 400) mV (0.4 to 1.3) V (1.3 to 5.5) V Up to 10 mV (10 to 40) mV (40 to 400) mV (0.4 to 1.3) V 0.10 mV p-p 0.34 mVp-p 0.0058 Vp-p 0.017 Vp-p 0.069 mVp-p 0.16 mVp-p 0.0024 Vp-p 0.012 Vp-p 0.15 Vp-p 0.5 mV 0.7 mV 4.3 mV 0.02 V 0.1 V 0.25 mV 0.55 mV 4.6 mV 0.015 V 0.075 V 0.3 mV 0.7 mV 6.1 mV 0.021 V 0.1 V 0.5 mV 1.3 mV 4.3 mV 0.041 V 0.2 V 0.6 mV 1.6 mV 15 mV 0.05 V Fluke 5522A- SC1100 Fluke 5522A- SC1100 time marker Fluke 5522A- SC1100
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.02) 07/05/2024 Page 4 of 16 Parameter/Range Frequency CMC2, 5, 6 (±) Comments Oscilloscope 3 – (cont) Amplitude Time Markers (5-2-1 Sequence) into a 50 Ω Load Rise Time 10 mV to 2.5 V (1 to 2) ns (5 to 100) ns 100 ns to 20 ms 50 ms to 5 s 1 ns to 1 ms 0.0009 ns 0.0041 ns + 0.0006 ns/ns 0.0042 ms 0.0041 ms + 0.007 s/s 350 ps Fluke 5522A- SC1100 Parameter/Range Range CMC2, 5, 6 (±) Comments DC Voltage 3 – Generate (0 to 330) mV (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1050) V 0.0016 % + 0.81 µV 0.000 89 % + 1.6 µV 0.000 98 % + 16 µV 0.0014 % + 0.13 mV 0.0014 % + 1.4 mV Fluke 5522A DC Voltage 3 – Measure (0 to 200) mV 200 mV to 2 V (2 to 20) V (20 to 200) V (200 to 1000) V 7.5 µV/V + 0.1 µV 6.6 µV/V + 0.4 µV 3.5 µV/V + 4 µV 5.3 µV/V + 40 µV 5.2 µV/V + 0.4 mV Fluke 8508A DC Current3 – Generate Clamp-On Only³ (0 to 329.999) µA (0.33 to 3.299 999) mA (3.3 to 32.999 99) mA (33 to 329.9999) mA (0.33 to 1.099 99) A (1.1 to 2.999 99) A (3 to 10.9999) A (11 to 20.5) A (16.5 to 149.999) A (150 to 1025) A 0.012 % + 0.016 µA 0.0077 % + 0.042 µA 0.0077 % + 0.22 µA 0.008 % + 2 µA 0.016 % + 31 µA 0.03 % + 21 µA 0.039 % + 0.41 mA 0.078 % + 0.52 mA 0.027 A + 0.0038 A/A 0.68 A + 0.0006 A/A Fluke 5522A Fluke 5522A w/ 5500A Coil
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.02) 07/05/2024 Page 5 of 16 Parameter/Range Range CMC2, 5, 6 (±) Comments DC Current 3 – Measure (0 to 200) µA 200 µA to 2 mA (2 to 20) mA (20 to 200) mA 200 mA to 2 A (2 to 20) A (20 to 1000) A 14 µA/A + 0.4 nA 14 µA/A + 4 nA 15 µA/A + 40 nA 43 µA/A + 0.8 µA 0.2 mA/A + 1.6 µA 0.44 mA/A + 200 µA 0.024 A/A + 0.64 A Fluke 8508A Clamp-on ammeter Resistance3 – Generate (0 to 10.9999) Ω (11 to 32.9999) Ω (33 to 109.9999) Ω (110 to 329.9999) Ω 330 Ω to 1.099 999 kΩ (1.1 to 3.299 999) kΩ (3.3 to 10.999 99) kΩ (11 to 32.999 99) kΩ (33 to 109.9999) kΩ (110 to 329.9999) kΩ 330 kΩ to 1.099 999 MΩ (1.1 to 3.299 999) MΩ (3.3 to 10.999 99) MΩ (11 to 32.999 99) MΩ (33 to 109.9999) MΩ (110 to 329.9999) MΩ (330 to 1100) MΩ 0.0046 % + 0.78 mΩ 0.0017 % + 1.4 mΩ 0.0022 % + 1.1 mΩ 0.0022 % + 1.6 mΩ 0.0022 % + 1.6 mΩ 0.0022 % + 16 mΩ 0.0022 % + 16 mΩ 0.0022 % + 0.16 Ω 0.0022 % + 0.16 Ω 0.0025 % + 1.6 Ω 0.0025 % + 1.6 Ω 0.0047 % + 23 Ω 0.01 % + 39 Ω 0.019 % + 1.9 kΩ 0.039 % + 2.3 kΩ 0.23 % + 78 kΩ 1.2 % + 0.39 MΩ Fluke 5522A Resistance3 – Measure (0 to 2) Ω (2 to 20) Ω (20 to 200) Ω 200 Ω to 2 kΩ (2 to 20) kΩ (20 to 200) kΩ 200 kΩ to 2 MΩ (2 to 20) MΩ (20 to 200) MΩ 200 MΩ to 2 GΩ (2 to 20) GΩ 17 µΩ/Ω + 4 µΩ 11 µΩ/Ω + 14 Ω 9.8 µΩ/Ω + 50 mΩ 13 µΩ/Ω + 0.5 mΩ 10 µΩ/Ω + 5 mΩ 8.8 µΩ/Ω + 50 mΩ 11 µΩ/Ω + 1 Ω 18 µΩ/Ω + 100 Ω 58 µΩ/Ω + 10 kΩ 1.0 mΩ/Ω + 1 MΩ 0.14 % + 10 MΩ Fluke 8508A
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.02) 07/05/2024 Page 6 of 16 Parameter/Range Frequency CMC2, 6 (±) Comments AC Voltage3 – Generate (1 to 33) mV (33 to 330) mV (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz 0.064 % + 0.0049 mV 0.0096 % + 0.0075 mV 0.0076 % + 0.011 mV 0.061 % + 0.013 mV 0.27 % + 0.01 mV 0.14 % + 0.33 mV 0.023 % + 0.0067 mV 0.011 % + 0.0068 mV 0.013 % + 0.0067 mV 0.027 % + 0.0075 mV 0.062 % + 0.026 mV 0.16 % + 0.057 mV 0.028 % + 0.000 027 V 0.012 % + 0.000 046 V 0.015 % + 0.000 047 V 0.023 % + 0.000 04 V 0.055 % + 0.000 098 V 0.19 % + 0.000 47 V 0.027 % + 0.000 37 V 0.012 % + 0.000 47 V 0.019 % + 0.000 48 V 0.027 % + 0.000 47 V 0.07 % + 0.0013 V 0.015 % + 0.0018 V 0.016 % + 0.0048 V 0.02 % + 0.0046 V 0.025 % + 0.0041 V 0.16 % + 0.039 V 0.023 % + 0.0083 V 0.019 % + 0.013 V 0.023 % + 0.013 V Fluke 5522A
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.02) 07/05/2024 Page 7 of 16 Parameter/Range Frequency CMC2, 6 (±) Comments AC Voltage3 – Measure (0 to 200) mV (0.2 to 2) V (2 to 20) V (20 to 200) V (200 to 1050) V (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (10 to 40) Hz (40 to 10) kHz (10 to 30) kHz (30 to 100) kHz 0.013 % + 4 µV 0.011 % + 4 µV 0.011 % + 2 µV 0.011 % + 4 µV 0.030 % + 8 µV 0.071 % + 20 µV 0.011 % + 20 µV 85 µV/V + 20 µV 65 µV/V + 20 µV 85 µV/V + 20 µV 0.021 % + 40 µV 0.051 % + 200 µV 0.3 % + 2 mV 1 % + 2 mV 0.011 % + 200 µV 85 µV/V + 200 µV 65 µV/V + 200 µV 85 µV/V + 200 µ V 0.021 % + 400 µV 0.051 % + 2 mV 0.3 % + 20 mV 1 % + 20 mV 0.011 % + 2 mV 85 µV/V + 2 mV 65 µV/V + 2 mV 85 µV/V + 2 mV 0.021 % + 4 mV 0.051 % + 20 mV 0.3 % + 200 mV 1 % + 200 mV 0.011 % + 0.02 V 95 µV/V + 0.02 V 0.021 % + 0.04 V 0.051 % + 0.2 V Fluke 8508A
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.02) 07/05/2024 Page 8 of 16 Parameter/Range Frequency CMC2, 6 (±) Comments AC Current 3 – Generate (1 to 329.99) µA (0.33 to 3.2999) mA (3.3 to 32.999) mA (33 to 329.99) mA (0.33 to 1.099 999) A (1.1 to 2.2) A (3 to 10.9999) A (11 to 20.5) A (10 to 20) Hz (20 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz (45 to 1000) Hz (1to 5) kHz (5 to 10) kHz (10 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (10 to 45) Hz (45 to 1000) Hz (1 to 5) kHz 0.16 % + 0.078 μA 0.12 % + 0.078 μA 0.098 % + 0.078 μA 0.23 % + 0.12 μA 0.62 % + 0.16 μA 1.2 % + 0.31 μA 0.16 % + 0.12 μA 0.098 % + 0.12 μA 0.078 % + 0.12 μA 0.16 % + 0.16 μA 0.4 % + 0.2 μA 0.78 % + 0.46 μA 0.14 % + 1.6 μA 0.071 % + 1.6 μA 0.034 % + 1.5 μA 0.064 % + 1.5 μA 0.16 % + 2.9 μA 0.32 % + 3.1 μA 0.14 % + 15 μA 0.071 % + 15 μA 0.033 % + 15 μA 0.079 % + 39 μA 0.16 % + 77 μA 0.32 % + 0.15 mA 0.14 % + 68 μA 0.04 % + 77 μA 0.47 % + 78 μA 1.9 % + 3.9 mA 0.14 % + 61 µA 0.059 % + 44 µA 0.47 % + 0.76 mA 1.9 % + 3.9 mA 0.051 % + 1.6 mA 0.081 % + 1.6 mA 2.3 % + 1.6 mA 0.095 % + 3.9 mA 0.12 % + 3.9 mA 2.3 % + 3.9 mA Fluke 5522A
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.02) 07/05/2024 Page 9 of 16 Parameter/Range Frequency CMC2, 6 (±) Comments AC Current3 – Generate (cont) Clamp-on Only³ - Toroidal (16.5 to 149.999) A (150 to 1025) A Non-Toroidal (16.5 to 1025) A (45 to 440) Hz (45 to 440) Hz (45 to 440) Hz 0.58 A + 3 mA/A 0.57 A + 3 mA/A 0.58 A + 5.8 mA/A Fluke 5522A w/ 5500A Coil AC Current 3 – Measure (0 to 200) µA 200 µA to 2 mA (2 to 20) mA (20 to 200) mA 200 mA to 2 A (2 to 20) A (20 to 1000) A (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz 10 Hz to 10 kHz 10 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz 10 Hz to 2 kHz (2 to 10) kHz (10 to 100) Hz (100 to 500) Hz 1.0 mA/A + 20 nA 0.55 mA/A + 20 nA 0.075 mA/A + 20 nA 0.62 mA/A + 0.20 µA 0.33 mA/A + 0.20 µA 0.75 mA/A + 0.20 µA 0.89 mA/A + 2.0 µA 0.32 mA/A + 2.0 µA 0.75 mA/A + 2.0 µA 0.29 mA/A + 20 µA 0.69 mA/A + 0.20 mA 0.82 mA/A + 0.20 mA 3.5 mA/A + 0.20 mA 0.93 mA/A + 2.0 mA 2.9 mA/A + 2.0 mA 0.65 A + 23 mA/A 0.69 A + 29 mA/A Fluke 8508A Clamp on ammeter
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.02) 07/05/2024 Page 10 of 16 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of Thermocouple Indicators 3 – Generate & Measure Type E Type J Type K Type T (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.41 °C 0.18 °C 0.16 °C 0.18 °C 0.21 °C 0.24 °C 0.18 °C 0.16 °C 0.18 °C 0.22 °C 0.28 °C 0.19 °C 0.18 °C 0.24 °C 0.34 °C 0.51 °C 0.22 °C 0.18 °C 0.17 °C Fluke 5522A Electrical Calibration of RTD Indicators 3 – Generate & Measure Pt 385, 100 Ω Pt 3926, 100 Ω (-200 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C (-200 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C 0.05 °C 0.07 °C 0.09 °C 0.10 °C 0.12 °C 0.23 °C 0.05 °C 0.07 °C 0.09 °C 0.10 °C 0.12 °C Fluke 5522A, Fluke 8508A
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.02) 07/05/2024 Page 11 of 16 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of RTD Indicators 3 – Generate & Measure (cont) Pt 3916, 100 Ω Pt 385, 200 Ω Pt 385, 500 Ω (-200 to -190) °C (-190 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 100) °C (100 to 260) °C (260 to 400) °C (400 to 600) °C (600 to 630) °C 0.25 °C 0.04 °C 0.05 °C 0.06 °C 0.07 °C 0.08 °C 0.09 °C 0.10 °C 0.23 °C 0.04 °C 0.05 °C 0.12 °C 0.13 °C 0.14 °C 0.16 °C 0.04 °C 0.05 °C 0.06 °C 0.08 °C 0.09 °C 0.11 °C Fluke 5522A, Fluke 8508A
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.02) 07/05/2024 Page 12 of 16 Parameter/Range Frequency CMC2, 6 (±) Comments Capacitance – Generate (220 to 399.9) pF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.999) nF (11 to 32.999) nF (33 to 109.999) nF (110 to 329.999) nF (0.33 to 1.1) µF (1.1 to 3.3) µF (3.3 to 11) µF (11 to 33) µF (33 to 110) µF (110 to 330) µF (0.33 to 1.1) mF (1.1 to 3.3) mF (3.3 to 11) mF (11 to 33) mF (33 to 110) mF 10 Hz to 10 kHz 10 Hz to 10 kHz 10 Hz to 3 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz (10 to 600) Hz (10 to 300) Hz (10 to 150) Hz (10 to 120) Hz (10 to 80) Hz DC to 50 Hz DC to 20 Hz DC to 6 Hz DC to 2 Hz DC to 0.6 Hz DC to 0.2 Hz 12 pF 0.015 nF 0.035 nF 0.035 nF 0.085 nF 0.26 nF 0.78 nF 0.0035 µF 0.011 µF 0.035 µF 0.15 µF 0.55 µF 2.4 µF 0.0055 mF 0.017 mF 0.055 mF 0.26 mF 1.2 mF Fluke 5522A III. Mechanical Parameter/Equipment Range CMC 2, 4, 5, 7 (±) Comments Scales & Balances 3 Linearity Repeatability Linearity 0.01 mg to 42 g (43 to 210) g 210 g to 5.1 kg (5.1 to 30) kg 0.01 mg to 42 g (43 to 210) g 210 g to 5.1 kg (5.1 to 30) kg Up to 1500 lb 0.000 21 g 0.000 25 g 0.028 g 0.028 g 0.000 028 g 0.000 14 g 0.019 g 0.000 26 kg 0.0058 lb + 0.0004 lb/lb Class 00, Class 0 & Class 1 weights Class F weights Mass – Measure 0.01 mg to 42 g (43 to 210) g 210 g to 6 kg (6 to 30) kg 0.000 03 g + 0.36 µg/g 0.000 15 g + 0.08 µg/g 0.018 g + 1.9 µg/g 0.17 g + 0.8 mg/g Analytical balances Top loading balances Torque – Measure 3 0.5 ozfꞏin to 600 lbfꞏft 0.3 % Torque transducers
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.02) 07/05/2024 Page 13 of 16 Parameter/Equipment Range CMC2, 4, 5, 7 (±) Comments Force Measurement 3 (1 to 10) lbf (10 to 100) lbf (100 to 500) lbf (500 to 1000) lbf (1000 to 5000) lbf (5000 to 10 000) lbf (10 000 to 50 000) lbf (50 000 to 500 000) lbf 0.0058 lbf + 15 µlbf/lbf 0.0058 lbf + 34 µlbf/lbf 0.053 lbf + 58 µlbf/lbf 0.57 lbf + 20 µlbf/lbf 5.8 lbf + 33 µlbf/lbf 12 lbf + 24 µlbf/lbf 57 lbf + 74 µlbf/lbf 210 lbf + 620 µlbf/lbf Load cells, Class F, Class 1 weights Load cells Pressure – Measure & Measuring Equipment Pneumatic Hydraulic (-14.7 to 50) PSI (0 to 500) PSI (300 to 1000) PSI (1000 to 5000) PSI (50 to 10 000) PSI 0.008 PSI + 9.7 µPSI/PSI 0.058 PSI + 0.72 µPSI/PSI 0.59 PSI 4.6 PSI + 9.7 µPSI/PSI 0.0025 PSI + 0.12 mPSI/PSI Mensor 2101 (-15 to 50) PSI Mensor 2101 (0 to 500) PSI Fluke 700P modules with Fluke 754 DHI 5303 Pressure –Field³, Measure & Measuring Equipment Hydraulic Pneumatic (5 to 10 000) PSI (-14.7 to 30) PSI (30 to 100) PSI (100 to 300) PSI (300 to 1000) PSI (1000 to 5000) PSI 1.7 PSI + 0.99 mPSI/PSI 0.024 PSI 0.082 PSI 0.18 PSI 0.59 PSI 4.7 PSI Crystal OKPSIXP21 Fluke 700P modules with Fluke 754 Tachometers3 – Non-Contact (0 to 100 000) RPM 0.062 RPM + 0.000 005 6 RPM/RPM Function generator & LED strobe
14AMS2750Magnesium; Mag/Aluminum; Aluminum; Moisture blocks; Liquid bath; Dry blockSee scope document
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.02) 07/05/2024 Page 15 of 16 Parameter/Equipment Range CMC2, 5, 7 (±) Comments Temperature – Measure (-20 to < 0) °C 0 °C (> 0 to 200) °C (> 200 to 400) °C (400 to 650) °C 0.084 °C 0.019 °C 0.040 °C 0.053 °C 0.067 °C Accumac AM1751 Relative Humidity – Measure 3 (13 to 73) % RH @ 25 °C (10 to 95) % RH 1.2 % 1.8 % Vaisala HMI41/HMP46 V. Time & Frequency Parameter/Equipment Range CMC 2, 7 (±) Comments Stopwatches/Timers 3 Up to 30 days 0.037 s/day Timometer Frequency – Measure3 Up to 200 MHz 1.2 parts in 107 Hz/Hz + 0.001 Hz Agilent 53132A Frequency – Measuring Equipment 3 Up to 3 GHz 1.3 parts in 109 Hz/Hz Signal generator ___________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC.
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.02) 07/05/2024 Page 16 of 16 4 In the statement of CMC, L is the numerical values of the nominal length of the device measured in inches, R is the numerical value of the resolutio n of the device in microinches, and D is the diameter of the device in inches 5 In the statement of CMC, a % denotes a percent of reading unless otherwise noted. 6 The measurands stated are generated using the indi cated instrument (see Comm ents). This capability is suitable for the calibration of the devices intended to measure the measurand in the ranges indicated. CMC's are expressed as either a specific value that covers the full range or as a fraction/percentage of the reading plus a fixed floor specification. 7 The type of instrument or material being calibrate d is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter 8 This scope meets A2LA’s P112 Flexible Scope Policy.
17ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.