National Calibration
6721 Edith Blvd NE, Suite C, 87113, Albuquerque, NM, United States
Visit website- Scope lines
- 17
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 17 scope lines.
A2LA certificate 1892.02 · 17 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 8 in |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1892.02) 07/05/2024 Page 2 of 16
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Micrometers
3 –
Depth Micrometers
ID Micrometers
OD Micrometers
Up to 6 in
(6 to 12) in
Up to 8 in
(8 to 16) in
(16 to 24) in
(24 to 32) in
(32 to 40) in
Up to 8 in
(8 to 16) in
(16 to 24) in
(24 to 32) in
(32 to 40) in
29 µin + 1.6 µin/in
8.8 µin + 4.4 µin/in
58 µin + 1 µin/in
49 µin + 2.3 µin/in
48 µin + 2.3 µin/in
43 µin + 2.6 µin/in
32 µin + 2.9 µin/in
28 µin + 1.3 µin/in
19 µin + 3.1 µin/in
33 µin + 1 µin/in
22 µin + 2.9 µin/in
24 µin + 3.2 µin/in
Gage blocks
Pin Gauges/Plug Gages
(0.011 to 0.060) in
(0.061 to 0.250) in
(0.251 to 0.500) in
(0.501 to 0.625) in
(0.626 to 1.000) in
(1.000 to 4.000) in
(24 + 0.1D) µin
(24 + 0.1D) µin
(24 + 0.1D) µin
(24 + 0.1D) µin
(24 + 0.3D) µin
(24 + 1D) µin
Supermicrometer
TM
Thread Plug Gages –
(Pitch & Major
Diameter)
Up to 6 in
Major Diameter
Pitch Diameter
(21 + 1.4D) µin
(120 + 1.9D) µin
Supermicrometer
TM,
thread wires | to 40 in |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1892.02) 07/05/2024 Page 3 of 16
II. Electrical – DC/Low Frequency
Parameter/Range
Range
CMC2, 5, 6 (±)
Comments
Oscilloscopes
3 –
Square Wave Signal
10 Hz to 10 kHz
50 Ω Impedance
1 MΩ Impedance
Level Sine Wave
Flatness –
50 kHz Ref
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
600 MHz to 1.1 GHz
(1 to 24.999) mV
p-p
(25 to 109.999) mVp-p
(0.11 to 2.1999) Vp-p
(2.2 to 6.6) Vp-p
(1 to 24.999) mVp-p
(25 to 109.999) mVp-p
(0.11 to 2.1999) Vp-p
(2.2 to 10.999) Vp-p
(11 to 130) Vp-p
Up to 10 mV
(10 to 40) mV
(40 to 400) mV
(0.4 to 1.3) V
(1.3 to 5.5) V
Up to 10 mV
(10 to 40) mV
(40 to 400) mV
(0.4 to 1.3) V
(1.3 to 5.5) V
Up to 10 mV
(10 to 40) mV
(40 to 400) mV
(0.4 to 1.3) V
(1.3 to 5.5) V
Up to 10 mV
(10 to 40) mV
(40 to 400) mV
(0.4 to 1.3) V
(1.3 to 5.5) V
Up to 10 mV
(10 to 40) mV
(40 to 400) mV
(0.4 to 1.3) V
0.10 mV
p-p
0.34 mVp-p
0.0058 Vp-p
0.017 Vp-p
0.069 mVp-p
0.16 mVp-p
0.0024 Vp-p
0.012 Vp-p
0.15 Vp-p
0.5 mV
0.7 mV
4.3 mV
0.02 V
0.1 V
0.25 mV
0.55 mV
4.6 mV
0.015 V
0.075 V
0.3 mV
0.7 mV
6.1 mV
0.021 V
0.1 V
0.5 mV
1.3 mV
4.3 mV
0.041 V
0.2 V
0.6 mV
1.6 mV
15 mV
0.05 V
Fluke 5522A-
SC1100
Fluke 5522A-
SC1100 time
marker
Fluke 5522A-
SC1100 | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1892.02) 07/05/2024 Page 4 of 16
Parameter/Range
Frequency
CMC2, 5, 6 (±)
Comments
Oscilloscope
3 – (cont)
Amplitude Time Markers
(5-2-1 Sequence) into a
50 Ω Load
Rise Time
10 mV to 2.5 V
(1 to 2) ns
(5 to 100) ns
100 ns to 20 ms
50 ms to 5 s
1 ns to 1 ms
0.0009 ns
0.0041 ns + 0.0006 ns/ns
0.0042 ms
0.0041 ms + 0.007 s/s
350 ps
Fluke 5522A-
SC1100
Parameter/Range
Range
CMC2, 5, 6 (±)
Comments
DC Voltage
3 –
Generate
(0 to 330) mV
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1050) V
0.0016 % + 0.81 µV
0.000 89 % + 1.6 µV
0.000 98 % + 16 µV
0.0014 % + 0.13 mV
0.0014 % + 1.4 mV
Fluke 5522A
DC Voltage
3 – Measure
(0 to 200) mV
200 mV to 2 V
(2 to 20) V
(20 to 200) V
(200 to 1000) V
7.5 µV/V + 0.1 µV
6.6 µV/V + 0.4 µV
3.5 µV/V + 4 µV
5.3 µV/V + 40 µV
5.2 µV/V + 0.4 mV
Fluke 8508A
DC Current3 –
Generate
Clamp-On Only³
(0 to 329.999) µA
(0.33 to 3.299 999) mA
(3.3 to 32.999 99) mA
(33 to 329.9999) mA
(0.33 to 1.099 99) A
(1.1 to 2.999 99) A
(3 to 10.9999) A
(11 to 20.5) A
(16.5 to 149.999) A
(150 to 1025) A
0.012 % + 0.016 µA
0.0077 % + 0.042 µA
0.0077 % + 0.22 µA
0.008 % + 2 µA
0.016 % + 31 µA
0.03 % + 21 µA
0.039 % + 0.41 mA
0.078 % + 0.52 mA
0.027 A + 0.0038 A/A
0.68 A + 0.0006 A/A
Fluke 5522A
Fluke 5522A
w/ 5500A Coil | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1892.02) 07/05/2024 Page 5 of 16
Parameter/Range
Range
CMC2, 5, 6 (±)
Comments
DC Current
3 – Measure
(0 to 200) µA
200 µA to 2 mA
(2 to 20) mA
(20 to 200) mA
200 mA to 2 A
(2 to 20) A
(20 to 1000) A
14 µA/A + 0.4 nA
14 µA/A + 4 nA
15 µA/A + 40 nA
43 µA/A + 0.8 µA
0.2 mA/A + 1.6 µA
0.44 mA/A + 200 µA
0.024 A/A + 0.64 A
Fluke 8508A
Clamp-on
ammeter
Resistance3 – Generate
(0 to 10.9999) Ω
(11 to 32.9999) Ω
(33 to 109.9999) Ω
(110 to 329.9999) Ω
330 Ω to 1.099 999 kΩ
(1.1 to 3.299 999) kΩ
(3.3 to 10.999 99) kΩ
(11 to 32.999 99) kΩ
(33 to 109.9999) kΩ
(110 to 329.9999) kΩ
330 kΩ to 1.099 999 MΩ
(1.1 to 3.299 999) MΩ
(3.3 to 10.999 99) MΩ
(11 to 32.999 99) MΩ
(33 to 109.9999) MΩ
(110 to 329.9999) MΩ
(330 to 1100) MΩ
0.0046 % + 0.78 mΩ
0.0017 % + 1.4 mΩ
0.0022 % + 1.1 mΩ
0.0022 % + 1.6 mΩ
0.0022 % + 1.6 mΩ
0.0022 % + 16 mΩ
0.0022 % + 16 mΩ
0.0022 % + 0.16 Ω
0.0022 % + 0.16 Ω
0.0025 % + 1.6 Ω
0.0025 % + 1.6 Ω
0.0047 % + 23 Ω
0.01 % + 39 Ω
0.019 % + 1.9 kΩ
0.039 % + 2.3 kΩ
0.23 % + 78 kΩ
1.2 % + 0.39 MΩ
Fluke 5522A
Resistance3 – Measure
(0 to 2) Ω
(2 to 20) Ω
(20 to 200) Ω
200 Ω to 2 kΩ
(2 to 20) kΩ
(20 to 200) kΩ
200 kΩ to 2 MΩ
(2 to 20) MΩ
(20 to 200) MΩ
200 MΩ to 2 GΩ
(2 to 20) GΩ
17 µΩ/Ω + 4 µΩ
11 µΩ/Ω + 14 Ω
9.8 µΩ/Ω + 50 mΩ
13 µΩ/Ω + 0.5 mΩ
10 µΩ/Ω + 5 mΩ
8.8 µΩ/Ω + 50 mΩ
11 µΩ/Ω + 1 Ω
18 µΩ/Ω + 100 Ω
58 µΩ/Ω + 10 kΩ
1.0 mΩ/Ω + 1 MΩ
0.14 % + 10 MΩ
Fluke 8508A | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1892.02) 07/05/2024 Page 6 of 16
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
AC Voltage3 – Generate
(1 to 33) mV
(33 to 330) mV
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
0.064 % + 0.0049 mV
0.0096 % + 0.0075 mV
0.0076 % + 0.011 mV
0.061 % + 0.013 mV
0.27 % + 0.01 mV
0.14 % + 0.33 mV
0.023 % + 0.0067 mV
0.011 % + 0.0068 mV
0.013 % + 0.0067 mV
0.027 % + 0.0075 mV
0.062 % + 0.026 mV
0.16 % + 0.057 mV
0.028 % + 0.000 027 V
0.012 % + 0.000 046 V
0.015 % + 0.000 047 V
0.023 % + 0.000 04 V
0.055 % + 0.000 098 V
0.19 % + 0.000 47 V
0.027 % + 0.000 37 V
0.012 % + 0.000 47 V
0.019 % + 0.000 48 V
0.027 % + 0.000 47 V
0.07 % + 0.0013 V
0.015 % + 0.0018 V
0.016 % + 0.0048 V
0.02 % + 0.0046 V
0.025 % + 0.0041 V
0.16 % + 0.039 V
0.023 % + 0.0083 V
0.019 % + 0.013 V
0.023 % + 0.013 V
Fluke 5522A | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1892.02) 07/05/2024 Page 7 of 16
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
AC Voltage3 – Measure
(0 to 200) mV
(0.2 to 2) V
(2 to 20) V
(20 to 200) V
(200 to 1050) V
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(10 to 40) Hz
(40 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
0.013 % + 4 µV
0.011 % + 4 µV
0.011 % + 2 µV
0.011 % + 4 µV
0.030 % + 8 µV
0.071 % + 20 µV
0.011 % + 20 µV
85 µV/V + 20 µV
65 µV/V + 20 µV
85 µV/V + 20 µV
0.021 % + 40 µV
0.051 % + 200 µV
0.3 % + 2 mV
1 % + 2 mV
0.011 % + 200 µV
85 µV/V + 200 µV
65 µV/V + 200 µV
85 µV/V + 200 µ
V
0.021 % + 400 µV
0.051 % + 2 mV
0.3 % + 20 mV
1 % + 20 mV
0.011 % + 2 mV
85 µV/V + 2 mV
65 µV/V + 2 mV
85 µV/V + 2 mV
0.021 % + 4 mV
0.051 % + 20 mV
0.3 % + 200 mV
1 % + 200 mV
0.011 % + 0.02 V
95 µV/V + 0.02 V
0.021 % + 0.04 V
0.051 % + 0.2 V
Fluke 8508A | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1892.02) 07/05/2024 Page 8 of 16
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
AC Current
3 – Generate
(1 to 329.99) µA
(0.33 to 3.2999) mA
(3.3 to 32.999) mA
(33 to 329.99) mA
(0.33 to 1.099 999) A
(1.1 to 2.2) A
(3 to 10.9999) A
(11 to 20.5) A
(10 to 20) Hz
(20 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
(45 to 1000) Hz
(1to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(10 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
0.16 % + 0.078 μA
0.12 % + 0.078 μA
0.098 % + 0.078 μA
0.23 % + 0.12 μA
0.62 % + 0.16 μA
1.2 % + 0.31 μA
0.16 % + 0.12 μA
0.098 % + 0.12 μA
0.078 % + 0.12 μA
0.16 % + 0.16 μA
0.4 % + 0.2 μA
0.78 % + 0.46 μA
0.14 % + 1.6 μA
0.071 % + 1.6 μA
0.034 % + 1.5 μA
0.064 % + 1.5 μA
0.16 % + 2.9 μA
0.32 % + 3.1 μA
0.14 % + 15 μA
0.071 % + 15 μA
0.033 % + 15 μA
0.079 % + 39 μA
0.16 % + 77 μA
0.32 % + 0.15 mA
0.14 % + 68 μA
0.04 % + 77 μA
0.47 % + 78 μA
1.9 % + 3.9 mA
0.14 % + 61 µA
0.059 % + 44 µA
0.47 % + 0.76 mA
1.9 % + 3.9 mA
0.051 % + 1.6 mA
0.081 % + 1.6 mA
2.3 % + 1.6 mA
0.095 % + 3.9 mA
0.12 % + 3.9 mA
2.3 % + 3.9 mA
Fluke 5522A | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1892.02) 07/05/2024 Page 9 of 16
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
AC Current3 – Generate
(cont)
Clamp-on Only³ -
Toroidal
(16.5 to 149.999) A
(150 to 1025) A
Non-Toroidal
(16.5 to 1025) A
(45 to 440) Hz
(45 to 440) Hz
(45 to 440) Hz
0.58 A + 3 mA/A
0.57 A + 3 mA/A
0.58 A + 5.8 mA/A
Fluke 5522A
w/ 5500A Coil
AC Current
3 – Measure
(0 to 200) µA
200 µA to 2 mA
(2 to 20) mA
(20 to 200) mA
200 mA to 2 A
(2 to 20) A
(20 to 1000) A
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
10 Hz to 10 kHz
10 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
10 Hz to 2 kHz
(2 to 10) kHz
(10 to 100) Hz
(100 to 500) Hz
1.0 mA/A + 20 nA
0.55 mA/A + 20 nA
0.075 mA/A + 20 nA
0.62 mA/A + 0.20 µA
0.33 mA/A + 0.20 µA
0.75 mA/A + 0.20 µA
0.89 mA/A + 2.0 µA
0.32 mA/A + 2.0 µA
0.75 mA/A + 2.0 µA
0.29 mA/A + 20 µA
0.69 mA/A + 0.20 mA
0.82 mA/A + 0.20 mA
3.5 mA/A + 0.20 mA
0.93 mA/A + 2.0 mA
2.9 mA/A + 2.0 mA
0.65 A + 23 mA/A
0.69 A + 29 mA/A
Fluke 8508A
Clamp on ammeter | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1892.02) 07/05/2024 Page 10 of 16
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration of
Thermocouple
Indicators
3 – Generate &
Measure
Type E
Type J
Type K
Type T
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.41 °C
0.18 °C
0.16 °C
0.18 °C
0.21 °C
0.24 °C
0.18 °C
0.16 °C
0.18 °C
0.22 °C
0.28 °C
0.19 °C
0.18 °C
0.24 °C
0.34 °C
0.51 °C
0.22 °C
0.18 °C
0.17 °C
Fluke 5522A
Electrical Calibration of
RTD Indicators
3 –
Generate & Measure
Pt 385, 100 Ω
Pt 3926, 100 Ω
(-200 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
(-200 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
0.05 °C
0.07 °C
0.09 °C
0.10 °C
0.12 °C
0.23 °C
0.05 °C
0.07 °C
0.09 °C
0.10 °C
0.12 °C
Fluke 5522A,
Fluke 8508A | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1892.02) 07/05/2024 Page 11 of 16
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration of
RTD Indicators
3 –
Generate & Measure
(cont)
Pt 3916, 100 Ω
Pt 385, 200 Ω
Pt 385, 500 Ω
(-200 to -190) °C
(-190 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 100) °C
(100 to 260) °C
(260 to 400) °C
(400 to 600) °C
(600 to 630) °C
0.25 °C
0.04 °C
0.05 °C
0.06 °C
0.07 °C
0.08 °C
0.09 °C
0.10 °C
0.23 °C
0.04 °C
0.05 °C
0.12 °C
0.13 °C
0.14 °C
0.16 °C
0.04 °C
0.05 °C
0.06 °C
0.08 °C
0.09 °C
0.11 °C
Fluke 5522A,
Fluke 8508A | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1892.02) 07/05/2024 Page 12 of 16
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
Capacitance – Generate
(220 to 399.9) pF
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.999) nF
(11 to 32.999) nF
(33 to 109.999) nF
(110 to 329.999) nF
(0.33 to 1.1) µF
(1.1 to 3.3) µF
(3.3 to 11) µF
(11 to 33) µF
(33 to 110) µF
(110 to 330) µF
(0.33 to 1.1) mF
(1.1 to 3.3) mF
(3.3 to 11) mF
(11 to 33) mF
(33 to 110) mF
10 Hz to 10 kHz
10 Hz to 10 kHz
10 Hz to 3 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
(10 to 600) Hz
(10 to 300) Hz
(10 to 150) Hz
(10 to 120) Hz
(10 to 80) Hz
DC to 50 Hz
DC to 20 Hz
DC to 6 Hz
DC to 2 Hz
DC to 0.6 Hz
DC to 0.2 Hz
12 pF
0.015 nF
0.035 nF
0.035 nF
0.085 nF
0.26 nF
0.78 nF
0.0035 µF
0.011 µF
0.035 µF
0.15 µF
0.55 µF
2.4 µF
0.0055 mF
0.017 mF
0.055 mF
0.26 mF
1.2 mF
Fluke 5522A
III. Mechanical
Parameter/Equipment
Range
CMC
2, 4, 5, 7 (±)
Comments
Scales & Balances
3
Linearity
Repeatability
Linearity
0.01 mg to 42 g
(43 to 210) g
210 g to 5.1 kg
(5.1 to 30) kg
0.01 mg to 42 g
(43 to 210) g
210 g to 5.1 kg
(5.1 to 30) kg
Up to 1500 lb
0.000 21 g
0.000 25 g
0.028 g
0.028 g
0.000 028 g
0.000 14 g
0.019 g
0.000 26 kg
0.0058 lb + 0.0004 lb/lb
Class 00, Class 0 &
Class 1 weights
Class F weights
Mass – Measure
0.01 mg to 42 g
(43 to 210) g
210 g to 6 kg
(6 to 30) kg
0.000 03 g + 0.36 µg/g
0.000 15 g + 0.08 µg/g
0.018 g + 1.9 µg/g
0.17 g + 0.8 mg/g
Analytical balances
Top loading
balances
Torque – Measure
3
0.5 ozfꞏin to 600 lbfꞏft
0.3 %
Torque transducers | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1892.02) 07/05/2024 Page 13 of 16
Parameter/Equipment
Range
CMC2, 4, 5, 7 (±)
Comments
Force Measurement
3
(1 to 10) lbf
(10 to 100) lbf
(100 to 500) lbf
(500 to 1000) lbf
(1000 to 5000) lbf
(5000 to 10 000) lbf
(10 000 to 50 000) lbf
(50 000 to 500 000) lbf
0.0058 lbf + 15 µlbf/lbf
0.0058 lbf + 34 µlbf/lbf
0.053 lbf + 58 µlbf/lbf
0.57 lbf + 20 µlbf/lbf
5.8 lbf + 33 µlbf/lbf
12 lbf + 24 µlbf/lbf
57 lbf + 74 µlbf/lbf
210 lbf + 620 µlbf/lbf
Load cells, Class F,
Class 1 weights
Load cells
Pressure – Measure &
Measuring Equipment
Pneumatic
Hydraulic
(-14.7 to 50) PSI
(0 to 500) PSI
(300 to 1000) PSI
(1000 to 5000) PSI
(50 to 10 000) PSI
0.008 PSI +
9.7 µPSI/PSI
0.058 PSI +
0.72 µPSI/PSI
0.59 PSI
4.6 PSI + 9.7 µPSI/PSI
0.0025 PSI +
0.12 mPSI/PSI
Mensor 2101
(-15 to 50) PSI
Mensor 2101
(0 to 500) PSI
Fluke 700P
modules with Fluke
754
DHI 5303
Pressure –Field³,
Measure & Measuring
Equipment
Hydraulic
Pneumatic
(5 to 10 000) PSI
(-14.7 to 30) PSI
(30 to 100) PSI
(100 to 300) PSI
(300 to 1000) PSI
(1000 to 5000) PSI
1.7 PSI + 0.99 mPSI/PSI
0.024 PSI
0.082 PSI
0.18 PSI
0.59 PSI
4.7 PSI
Crystal
OKPSIXP21
Fluke 700P
modules with Fluke
754
Tachometers3 –
Non-Contact
(0 to 100 000) RPM
0.062 RPM
+ 0.000 005 6
RPM/RPM
Function generator
& LED strobe | ||
| 14 | AMS2750 | Magnesium; Mag/Aluminum; Aluminum; Moisture blocks; Liquid bath; Dry block | See scope document |
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1892.02) 07/05/2024 Page 15 of 16
Parameter/Equipment
Range
CMC2, 5, 7 (±)
Comments
Temperature – Measure
(-20 to < 0) °C
0 °C
(> 0 to 200) °C
(> 200 to 400) °C
(400 to 650) °C
0.084 °C
0.019 °C
0.040 °C
0.053 °C
0.067 °C
Accumac
AM1751
Relative Humidity –
Measure
3
(13 to 73) % RH @
25 °C
(10 to 95) % RH
1.2 %
1.8 %
Vaisala
HMI41/HMP46
V. Time & Frequency
Parameter/Equipment
Range
CMC
2, 7 (±)
Comments
Stopwatches/Timers
3
Up to 30 days
0.037 s/day
Timometer
Frequency – Measure3
Up to 200 MHz
1.2 parts in 107 Hz/Hz +
0.001 Hz
Agilent 53132A
Frequency – Measuring
Equipment
3
Up to 3 GHz
1.3 parts in 109 Hz/Hz
Signal generator
___________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC. | ||
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1892.02) 07/05/2024 Page 16 of 16
4 In the statement of CMC, L is the numerical values of the nominal length of the device measured in inches,
R is the numerical value of the resolutio n of the device in microinches, and D is the diameter of the
device in inches
5 In the statement of CMC, a % denotes a percent of reading unless otherwise noted.
6 The measurands stated are generated using the indi cated instrument (see Comm ents). This capability is
suitable for the calibration of the devices intended to measure the measurand in the ranges indicated.
CMC's are expressed as either a specific value that covers the full range or as a fraction/percentage of the
reading plus a fixed floor specification.
7 The type of instrument or material being calibrate d is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter
8 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 17 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in United States
- Technical Maintenance, Inc. - COLORADO SPRINGSColorado Springs, CO · ~447 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - PhoenixScottsdale, AZ · ~516 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Mass Flow One (dba) Precision FlowTempe, AZ · ~520 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- ATLAS MATERIAL TESTING TECHNOLOGY LLC ATLAS WEATHERING SERVICES GROUPPhoenix, AZ · ~522 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Applied Technical Services, LLC.Tempe, AZ · ~522 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.