National Calibration

1395 N Hayden Rd, 85257, Scottsdale, AZ, United States

Visit website
A2LA 1892.01ISO/IEC 17025Register refreshed 2026-10-23

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
24
A2LA certificate
1
Sites in our directory
4
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 24 scope lines.

A2LA certificate 1892.01 · 24 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-to 80 in
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.01) Revised 12/17/2025 Page 2 of 23 Parameter/Equipment Range CMC2, 4 (±) Comments Height Master Up to 36 in (76 + 1.7L) µin Gage blocks Indicators3 Up to 6 in (29 + 0.8L) μin LabmasterTM, Gage blocks, SupermicrometerTM Length Standards Up to 12 in (12 to 40) in (4 + 1.9L) μin (23 + 2.8L) μin LabmasterTM, gage blocks, Electronic height gage, surface plate, gage blocks (standardization) Micrometers3 – ID Mics OD Mics Depth Mics Tri-Mics V-Anvil Mics Up to 8 in (8 to 16) in (16 to 24) in (24 to 32) in (32 to 40) in Up to 8 in (8 to 16) in (16 to 24) in (24 to 32) in (32 to 40) in (40 to 48) in (48 to 56) in Up to 6 in (6 to 12) in (0.01 to 0.018) in (0.15 to 6) in Up to 2 in (58 + 0.72L) µin (49 + 2.3L) µin (48 + 2.3L) µin (43 + 2.6L) µin (32 + 2.9L) µin (28 + 1.3L) µin (19 + 3.1L) µin (24 + 2.8L) µin (22 + 2.9L) µin (14 + 3.1L) µin (33 + 2.6L) µin (20 + 2.9L) µin (29 + 1.1L) µin (8.8 + 4.4L) µin (37 + 0.025D) µin (120 + 4.0D) µin (61 + 7.6L) µin Gage blocks Gage blocks Gage blocks, triangle base Ring gages Plug gages Pin Gauges/Plug Gages (0.011 to 0.060) in (0.061 to 0.250) in (0.251 to 0.500) in (0.501 to 0.625) in (0.626 to 1.000) in (1.000 to 4.000) in (8.1 + 32D) μin (8.7 + 1.4D) μin (7.6 + 5.6D) μin (8.6 + 3.7D) μin (4.1 + 8.1D) μin (8.6 + 6.4D) μin LabMasterTM
to 36 in
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.01) Revised 12/17/2025 Page 3 of 23 Parameter/Equipment Range CMC2, 4 (±) Comments Digital Protractors Up to 45° 0.005° Sine Plate & Gage Blocks Plain Ring Gage (0.04 to 0.125) in (0.125 to 0.25) in (0.25 to 1) in (1 to 10) in (6.6 + 14.7D) μin (8.4 + 24.2D) μin (17 + 9.5D) μin (2 + 8.4D) μin LabMasterTM Ruler Calibrator Up to 40 in 0.0005 in Gage blocks Rules Up to 40 in 0.002 in Rule calibrator Thread Plug Gages – (Pitch & Major Diameter) Up to 6 in Pitch Diameter Major Diameter (120 + 1.9D) µin (21 + 1.3D) µin SupermicrometerTM SupermicrometerTM Up to 10 in total length Up to 1 in travel from reference (6.8 + 6.7L) µin Gage blocks, force gage LabMasterTM Up to 12 in total length Up to 2 in travel from reference Ratiometric / Repeatability 2 in 3 in 4 in 3.0 μin + 3.9 μin/in from Datum 6.2 μin 8.2 μin 10 μin Gage blocks, force gage Feeler Gages Up to 0.25 in (14 + 0.1L) μin SupermicrometerTM, LabmasterTM
to 45 °
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.01) Revised 12/17/2025 Page 4 of 23 II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 5, 6 (±) Comments Oscilloscopes3 – Square Wave Signal 10 Hz to 10 kHz 50Ω Impedance 10 Hz to 10 kHz 1MΩ Impedance Level Sine Wave Flatness 50 kHz Ref 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz 600 MHz to 1.1 GHz (1 to 24.999) mV p-p (25 to 109.999) mVp-p (0.11 to 2.1999) Vp-p (2.2 to 6.6) Vp-p (1 to 24.999) mV p-p (25 to 109.999) mVp-p (0.11 to 2.1999) Vp-p (2.2 to 10.999) Vp-p (11 to 130) Vp-p Up to 10 mV (10 to 40) mV (40 to 400) mV (0.4 to 1.3) V (1.3 to 5.5) V Up to 10 mV (10 to 40) mV (40 to 400) mV (0.4 to 1.3) V (1.3 to 5.5) V Up to 10 mV 10 to 40 mV 40 to 400 mV 0.4 to 1.3 V 1.3 to 5.5V Up to 10 mV (10 to 40) mV (40 to 400) mV (0.4 to 1.3) V (1.3 to 5.5) V Up to 10 mV (10 to 40) mV (40 to 400) mV (0.4 to 1.3) V 0.10 mV p-p 0.34 mVp-p 0.0058 Vp-p 0.017 Vp-p 0.069 mV p-p 0.16 mVp-p 0.0024 Vp-p 0.012 Vp-p 0.15 Vp-p 0.7 mV 0.5 mV 4.3 mV 0.02 V 0.1 V 0.25 mV 0.55 mV 4.6 mV 0.015 V 0.075 V 0.3 mV 0.7 mV 6.1 mV 0.021 V 0.1 V 0.5 mV 1.3 mV 4.3 mV 0.041 V 0.2 V 0.6 mV 1.6 mV 15 mV 0.05 V Fluke 5522A- SC1100
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.01) Revised 12/17/2025 Page 5 of 23 Parameter/Equipment Range CMC2, 5, 6 (±) Comments Oscilloscopes3 – (cont) Amplitude Time Markers (5-2-1 Sequence) into a 50 Ω Load Rise Time 10 mV to 2.5 V (1 to 2) ns (5 to 100) ns 100 ns to 20 ms 50 ms to 5 s 1 ns to 1 ms 0.0009 ns 0.0041 ns + 0.0006 ns/ns 0.0042 ms 0.0041 ms + 0.007 s/s 350 ps Fluke 5522A- SC1100 DC Voltage3 – Generate (0 to 220) mV 220 mV to 2.2 V (2.2 to 11) V (11 to 22) V (22 to 220) V (220 to 1100) V 9.5 µV/V + 0.4 µV 5.9 µV/V + 0.7 µV 4.1 µV/V + 2.5 µV 4.1 µV/V + 4 µV 5.9 µV/V + 40 µV 7.6 µV/V + 0.4 mV Fluke 5730A DC Voltage3 – Measure (0 to 200) mV 200 mV to 2 V (2 to 20) V (20 to 200) V (200 to 1000) V 7.5 µV/V + 0.1 µV 6.6 µV/V + 0.4 µV 3.5 µV/V + 4 µV 5.3 µV/V + 40 µV 5.2 µV/V + 0.4 mV Fluke 8508A DC High Voltage – Measure (1 to 10) kV (10 to 35) kV (35 to 100) kV 0.18 + 0.49 mV/V 0.18 + 0.72 mV/V 0.96 + 1.2 mV/V Vitrek 4700 with HVL100 DC Current3 – Generate Clamp-On Only³ (0 to 220) µA 220 µV to 2.2 mA (2.2 to 22) mA (22 to 220) mA 220 mA to 2.2 A (2.2 to 11) A (11 to 20) A (16.5 to 149.999) A (150 to 1025) A 48 µA/A + 6 nA 42 µA/A + 7 nA 42 µA/A + 40 nA 53 µA/A + 0.7 µA 0.12 mA/A + 12 µA 0.42 mA/A + 0.48 mA 0.82 mA/A + 0.75 mA 0.39 % + 15 mA 0.48 % + 50 mA Fluke 5730A Fluke 5522A Fluke 5522A w/ 5500A Coil
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.01) Revised 12/17/2025 Page 6 of 23 Parameter/Equipment Range CMC2, 6 (±) Comments DC Current3 – Measure (0 to 200) µA 200 µA to 2 mA (2 to 20) mA (20 to 200) mA 200 mA to 2 A (2 to 20) A (20 to 1000) A 14 µA/A + 0.4 nA 14 µA/A + 4 nA 15 µA/A + 40 nA 43 µA/A + 0.8 µA 0.2 mA/A + 1.6 µA 0.44 mA/A + 200 µA 0.24 A/A + 0.64 A Fluke 8508A Clamp-on ammeter Resistance3 – Generate, Fixed Points 0 Ω 1 Ω 1.9 Ω 10.0 Ω 19.0 Ω 100 Ω 190 Ω 1.0 kΩ 1.9 kΩ 10 kΩ 19 kΩ 100 kΩ 190 kΩ 1.0 MΩ 1.9 MΩ 10 MΩ 19 MΩ 100 MΩ 46 µΩ 0.11 mΩ 0.11 mΩ 0.13 mΩ 0.27 mΩ 1.2 mΩ 1.2 mΩ 9.8 mΩ 9.8 mΩ 0.1 Ω 0.1 Ω 1.3 Ω 1.3 Ω 24 Ω 25 Ω 0.52 kΩ 0.58 kΩ 13 kΩ Fluke 5730A Resistance3 – Measure (0 to 2) Ω (2 to 20) Ω (20 to 200) Ω 200 Ω to 2 kΩ (2 to 20) kΩ (20 to 200) kΩ 200 kΩ to 2 MΩ (2 to 20) MΩ (20 to 200) MΩ 200 MΩ to 2 GΩ (2 to 20) GΩ 17 µΩ/Ω + 4 µΩ 11 µΩ/Ω + 14 µΩ 9.8 µΩ/Ω + 50 µΩ 13 µΩ/Ω + 0.5 mΩ 10 µΩ/Ω + 5 mΩ 8.8 µΩ/Ω + 50 mΩ 11 µΩ/Ω + 1 Ω 18 µΩ/Ω + 100 Ω 58 µΩ/Ω + 10 kΩ 1.0 mΩ/Ω + 1 MΩ 0.14 % + 10 MΩ Fluke 8508A
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.01) Revised 12/17/2025 Page 7 of 23 Parameter/Range Frequency CMC2, 6 (±) Comments AC Voltage3 – Generate (0.22 to 2.2) mV (2.2 to 22) mV (22 to 220) mV 220 mV to 2.2 V (2.2 to 22) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz 1.0 mV/V + 4 µV 0.98 mV/V + 4 µV 0.91 mV/V + 4 µV 0.78 mV/V + 4 µV 0.78 mV/V + 5 µV 1.3 mV/V + 10 µV 1.8 mV/V + 20 µV 3.4 mV/V + 20 µV 1.4 mV/V + 4 µV 0.20 mV/V + 4 µV 0.30 mV/V + 46 µV 0.30 mV/V + 4 µV 0.60 mV/V + 5 µV 1.2 mV/V + 10 µV 1.6 mV/V + 20 µV 3.1 mV/V + 20 µV 0.30 mV/V + 12 µV 0.10 mV/V + 7 µV 0.081 mV/V + 7 µV 0.23 mV/V + 7 µV 0.50 mV/V + 17 µV 1.0 mV/V + 20 µV 1.6 mV/V + 25 µV 3.1 mV/V + 45 µV 0.85 mV/V + 40 µV 0.82 mV/V + 15 µV 0.82 mV/V + 8 µV 0.82 mV/V + 10 µV 0.82 mV/V + 30 µV 0.92 mV/V + 80 µV 1.3 mV/V + 200 µV 1.9 mV/V + 300 µV 0.86 mV/V + 400 µV 0.82 mV/V + 150 µV 0.82 mV/V + 50 µV 0.82 mV/V + 100 µV 0.82 mV/V + 200 µV 0.86 mV/V + 600 µV 2.3 mV/V + 2 mV 1.9 mV/V + 3.2 mV Fluke 5730A
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.01) Revised 12/17/2025 Page 8 of 23 Parameter/Range Frequency CMC2, 6 (±) Comments AC Voltage3 – Generate (cont) (22 to 220) V (220 to 250) V (220 to 1100) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (15 to 50) Hz 50 Hz to 1 kHz 0.86 mV/V + 4 mV 0.82 mV/V + 1.5 mV 0.82 mV/V + 0.6 mV 0.82 mV/V + 1 mV 0.84 mV/V + 2.5 mV 1.3 mV/V + 16 mV 4.5 mV/V + 40 mV 8.0 mV/V + 80 mV 0.29 mV/V + 16 µV 67 µV/V + 3.5 µV Fluke 5730A AC Voltage3 – Measure Up to 199.99 mV 200 mV to 1.9999 V (2 to 19.999) V (20 to 199.99) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz 0.40 mV/V + 4 µV 0.26 mV/V + 4 µV 0.26 mV/V + 4 µV 0.36 mV/V + 4 µV 0.68 mV/V + 5 µV 1.4 mV/V + 10 µV 2.2 mV/V + 20 µV 3.4 mV/V + 20 µV 0.27 mV/V + 12 µV 0.11 mV/V + 7 µV 0.10 mV/V + 7 µV 0.21 mV/V + 7 µV 0.50 mV/V + 17 µV 0.90 mV/V + 20 µV 1.4 mV/V + 25 µV 2.7 mV/V + 45 µV 0.44 mV/V + 40 µV 0.38 mV/V + 150µV 0.37 mV/V + 8 µV 0.38 mV/V + 10 µV 0.39 mV/V + 30 µV 0.56 mV/V + 80 µV 1.0 mV/V + 200 µV 1.7 mV/V + 300 µV 0.88 mV/V + 400 µV 0.76 mV/V + 150 µV 0.75 mV/V + 50 µV 0.76 mV/V + 100 µV 0.77 mV/V + 200 µV 0.93 mV/V + 600 µV 2.1 mV/V + 2 mV 3.1 mV/V + 3.2 mV Fluke 5790A
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.01) Revised 12/17/2025 Page 9 of 23 Parameter/Range Frequency CMC2, 6 (±) Comments AC Voltage3 – Measure (cont) (200 to 1050) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz 0.88 mV/V + 400 µV 0.76 mV/V + 150 µV 0.75 mV/V + 50 µV 0.76 mV/V + 100 µV 0.77 mV/V + 200 µV 0.93 mV/V + 600 µV 2.1 mV/V + 600 µV 2.7 mV/V + 45 µV Fluke 5790A AC High Voltage – Measure (50 to 60) Hz (1 to 10) kV (10 to 35) kV (35 to 100) kV 0.25 V + 4.6 mV/V 0.25 V + 4.8 mV/V 4.9 V + 4.9 mV/V Vitrek 4700 with HVL100 AC Current3 – Generate Up to 220 µA 220 µA to 2.2 mA (2.2 to 22) mA (22 to 220) mA 220 mA to 2.2 A (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 20 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.36 mA/A + 16 nA 0.21 mA/A + 10 nA 0.14 mA/A + 8 nA 0.33 mA/A + 12 nA 1.3 mA/A + 65 nA 0.36 mA/A + 40 nA 0.20 mA/A + 35 nA 0.14 mA/A + 35 nA 0.23 mA/A + 0.11 µA 1.3 mA/A + 0.65 µA 0.35 mA/A + 0.40 µA 0.21 mA/A + 0.35µA 0.14 mA/A + 0.35 µA 0.23 mA/A + 0.55 µA 1.3 mA/A + 5.0 µA 0.37 mA/A + 4.0 µA 0.72 mA/A + 3.5 µA 0.14 mA/A + 3.5 µA 0.23 mA/A + 3.5 µA 1.3 mA/A + 10 µA 0.30 mA/A + 35 µA 0.53 mA/A + 80 µA 8.1 mA/A + 0.16 mA Fluke 5730A
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.01) Revised 12/17/2025 Page 10 of 23 Parameter/Range Frequency CMC2, 6 (±) Comments AC Current3 – Generate (cont) Clamp-on Meters³ Toroidal (16.5 to 149.999) A (150 to 1025) A Non-Toroidal (16.5 to 1025) A (45 to 65) Hz (65 to 440) Hz (45 to 440) Hz 0.58 A + 3 mA/A 0.57 A + 3 mA/A 0.58 A + 5.8 mA/A Fluke 5522A w/ 5500A Coil AC Current3 – Measure (0 to 200) µA 200 µA to 2 mA (2 to 20) mA (20 to 200) mA 200 mA to 2 A (2 to 20) A (20 to 1000) A (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz 10 Hz to 10 kHz 10 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz 10 Hz to 2 kHz (2 to 10) kHz (10 to 100) Hz (100 to 500) Hz 1.0 mA/A + 20 nA 0.55 mA/A + 20 nA 0.075 mA/A + 20 nA 0.62 mA/A + 0.20 µA 0.33 mA/A + 0.20 µA 0.75 mA/A + 0.20 µA 0.89 mA/A + 2.0 µA 0.32 mA/A + 2.0 µA 0.75 mA/A + 2.0 µA 0.29 mA/A + 20 µA 0.69 mA/A + 0.20 mA 0.82 mA/A + 0.20 mA 3.5 mA/A + 0.20 mA 0.93 mA/A + 2.0 mA 2.9 mA/A + 2.0 mA 0.65 A + 23 mA/A 0.69 A + 29 mA/A Fluke 8508A Clamp on ammeter
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.01) Revised 12/17/2025 Page 11 of 23 Parameter/Range Frequency CMC2, 5, 6 (±) Comments AC Flatness – Measure (220 to 700) mV 700 mV to 2.2 V (2.2 to 7) V (10 to 30) Hz (30 to 120) Hz (0.12 to 1.2) kHz (1.2 to 120) kHz (120 to 500) kHz (0.5 to 1.2) MHz (1.2 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (10 to 30) Hz (30 to 120) Hz (0.12 to 1.2) kHz (1.2 to 120) kHz (120 to 500) kHz (0.5 to 1.2) MHz (1.2 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (10 to 30) Hz (30 to 120) Hz (0.12 to 1.2) kHz (1.2 to 120) kHz (120 to 500) kHz (0.5 to 1.2) MHz (1.2 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz 0.1 % 0.03 % 0.03 % 0.04 % 0.04 % 0.06 % 0.06 % 0.14 % 0.27 % 0.35 % 0.1 % 0.04 % 0.04 % 0.03 % 0.03 % 0.06 % 0.07 % 0.1 % 0.2 % 0.35 % 0.1 % 0.04 % 0.04 % 0.04 % 0.04 % 0.05 % 0.06 % 0.1 % 0.2 % 0.35 % Fluke 5790A
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.01) Revised 12/17/2025 Page 12 of 23 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of Thermocouple Indicators3 – Generate & Measure Type E Type J Type K Type N Type R Type S Type T (-270 to 0) °C (0 to 600) °C (600 to 1000) °C (-210 to -0) °C (0 to 600) °C (600 to 1200) °C (-200 to 0) °C (0 to 600) °C (600 to 1372) °C (-200 to 0) °C (0 to 600) °C (600 to 1300) °C (0 to 400) °C (400 to 1000) °C (1000 to 1767) °C (0 to 500) °C (500 to 1000) °C (1000 to 1767) °C (-250 to 0) °C (0 to 120) °C (120 to 400) °C 0.032 °C 0.035 °C 0.039 °C 0.069 °C 0.038 °C 0.044 °C 0.091 °C 0.045 °C 0.063 °C 0.15 °C 0.057 °C 0.057 °C 0.27 °C 0.14 °C 0.13 °C 0.27 °C 0.18 °C 0.13 °C 0.21 °C 0.042 °C 0.038 °C Fluke 5730A. Fluke Ice Point 9101, Fluke 8508A
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.01) Revised 12/17/2025 Page 13 of 23 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of RTD Indicators3 – Generate & Measure Pt 385, 100 Ω Pt 3926, 100 Ω Pt 3916, 100 Ω Pt 385, 200 Ω Pt 385, 500 Ω Pt 385, 1000 Ω (-200 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C (-200 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (-200 to -190) °C (-190 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 100) °C (100 to 260) °C (260 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 600) °C (600 to 630) °C 0.05 °C 0.07 °C 0.09 °C 0.10 °C 0.12 °C 0.23 °C 0.05 °C 0.07 °C 0.09 °C 0.10 °C 0.12 °C 0.25 °C 0.04 °C 0.05 °C 0.06 °C 0.07 °C 0.08 °C 0.09 °C 0.10 °C 0.23 °C 0.04 °C 0.05 °C 0.12 °C 0.13 °C 0.14 °C 0.16 °C 0.04 °C 0.05 °C 0.06 °C 0.08 °C 0.09 °C 0.11 °C 0.03 °C 0.04 °C 0.05 °C 0.06 °C 0.07 °C 0.23 °C Fluke 5522A, Fluke 8508A
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.01) Revised 12/17/2025 Page 14 of 23 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of RTD Indicators3 (cont) – Generate & Measure PtNi 385, 120 Ω Cu 427, 10 Ω (-80 to 100) °C (100 to 260) °C (-100 to 260) °C 0.08 °C 0.14 °C 0.3 °C Fluke 5522A, Fluke 8508A Parameter/Range Frequency CMC2 (±) Comments Distortion – Measure (-75 to 0) dB Dist (-99.99 to 0) dB Dist 10 Hz to 500 kHz 9 kHz to 30 MHz 0.74 dB 1.2 dB U8903A E4440A Capacitance – Generate3 (220 to 399.9) pF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.999) nF (11 to 32.999) nF (33 to 109.999) nF (110 to 329.999) nF (0.33 to 1.1) µF (1.1 to 3.3) µF (3.3 to 11) µF (11 to 33) µF (33 to 110) µF (110 to 330) µF (0.33 to 1.1) mF (1.1 to 3.3) mF (3.3 to 11) mF (11 to 33) mF (33 to 110) mF 10 Hz to 10 kHz 10 Hz to 10 kHz 10 Hz to 3 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz (10 to 600) Hz (10 to 300) Hz (10 to 150) Hz (10 to 120) Hz (10 to 80) Hz DC to 50 Hz DC to 20 Hz DC to 6 Hz DC to 2 Hz DC to 0.6 Hz DC to 0.2 Hz 12 pF 0.015 nF 0.035 nF 0.035 nF 0.085 nF 0.26 nF 0.78 nF 0.0035 µF 0.011 µF 0.035 µF 0.15 µF 0.55 µF 2.4 µF 0.0055 mF 0.017 mF 0.055 mF 0.26 mF 1.2 mF Fluke 5522A
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.01) Revised 12/17/2025 Page 15 of 23 Parameter/Range Frequency CMC2, 5, 6 (±) Comments Capacitance – Generate3 (cont) Fixed Points 1 pF 10 pF 100 pF 1000 pF 0.01 µF 0.10 µF 1.0 µF 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 0.0012 pF 0.012 pF 0.12 pF 1.2 pF 0.000 74 µF 0.000 82 µF 0.0015 µF HP 16380A & HP 16380C standard capacitor sets Capacitance – Measure 10 pF 100 pF 1000 pF 0.1 µF 10 µF 120 Hz to 300 kHz 120 Hz to 300 kHz 120 Hz to 300 kHz 120 Hz to 100 kHz 120 Hz to 100 kHz 0.028 pF 0.19 pF 1.2 pF 0.000 61 µF 0.093 µF Agilent E4980A III. Electrical RF/Microwave Parameter/Equipment Range CMC2, 4, 5, 7 (±) Comments RF Attenuation - Tuned RF Power Measurement 100kHz to 10 MHz 10MHz to 3.05 GHz (3.05 to 6.6) GHz (6.6 to 13.2) GHz (13.2 to 19.2) GHz (19.2 to 26.5) GHz 0.89 dBm 0.2 dBm 0.2 dBm 0.2 dBm 0.2 dBm 0.2 dBm SP 8902A with 11722A N5531S MMR System RF Power – Generate (20 to 24) dBm (0.01 to 100) kHz (0.1 to 125) MHz (14 to 20) dBm (0.01 to 100) kHz (0.1 to 125) MHz (125 to 300) MHz (0.3 to 1.4) GHz 0.06 dB 0.06 dB 0.04 dB 0.06 dB 0.09 dB 0.23 dB Fluke 96270A Reference Source w/Leveling Head Output
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.01) Revised 12/17/2025 Page 16 of 23 Parameter/Equipment Range CMC3, 4, 5, 7 (±) Comments RF Power – Generate (cont) (-17 to 14) dBm (0.01 to 100) kHz (0.1 to 125) MHz (125 to 300) MHz (0.3 to 1.4) GHz (1.4 to 4.0) GHz (-120 to 16) dBm (2.4 to 8.0) GHz (8.0 to 12.0) GHz (12.0 to 18.0) GHz (18.0 to 22.0) GHz (22.0 to 26.5) GHz 0.04 dB 0.06 dB 0.09 dB 0.23 dB 0.35 dB 0.8 dB 0.8 dB 0.8 dB 0.8 dB 0.8 dB Fluke 96270A Reference Source w/Leveling Head Output Fluke 96270A Reference Source w/11667B Splitter Parameter/Range Frequency CMC4, 4, 5, 7 (±) Comments RF Attenuation - Tuned RF Power Measurement (-48 to -17) dBm (-74 to -48) dBm (-84 to -74) dBm (-94 to -84) dBm (-94 to -124) dB (0.01 to 100) kHz (0.1 to 125) MHz (125 to 300) MHz (0.3 to 1.4) GHz (1.4 to 3.0) GHz (3.0 to 4.0) GHz (0.1 to 10) MHz (10 to 125) MHz (125 to 300) MHz (0.3 to 1.4) GHz (1.4 to 4.0) GHz (0.1 to 10) MHz (10 to 125) MHz (125 to 300) MHz (0.3 to 1.4) GHz (1.4 to 4.0) GHz (0.1 to 10) MHz (10 to 125) MHz (125 to 300) MHz (0.3 to 3.0) GHz (10 to 125) MHz (125 to 300) MHz (0.3 to 1.4) GHz (1.4 to 3.0) GHz 0.04 dB 0.06 dB 0.09 dB 0.25 dB 0.40 dB 0.59 dB 0.23 dB 0.11 dB 0.11 dB 0.46 dB 0.57 dB 0.60 dB 0.10 dB 0.34 dB 0.57 dB 1.2 dB 0.60 dB 0.40 dB 0.60 dB 1.2 dB 0.80 dB 1.8 dB 1.8 dB 1.8 dB SP 8902A with 11722A N5531S MMR System
17

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.01) Revised 12/17/2025 Page 17 of 23 Parameter/Range Frequency CMC5, 4, 5, 7 (±) Comments RF Power – Measure (+20 to -30) dBm (+20 to -10) dBm DC – 30 MHz 30 MHz – 2.0 GHz (2 to 4.2) GHz (4.2 to 18) GHz (18 to 26.5) GHz 0.52 dBm + 1 digit 0.23 dBm 0.23 dBm 0.32 dBm 0.45 dBm 8902A with 1722A N5531S MMR System with N5532B Power Reference Measure 1 mW, 50 MHz 1.2 % N432A, HP 3458A, HP 478A-H55 Thermistor Mount Parameter/Equipment Range CMC6, 4, 5, 7 (±) Comments Amplitude Modulation – Measure 100 kHz to 10 MHz 10 MHz to 3 GHz 3 GHz to 26.5 GHz Rate: 50 Hz to 10 kHz Depth: 5% to 99% Rate: 50 Hz to 100 kHz Depth: 20 % to 99% Depth: 5% to 20% Rate: 50 Hz to 100kHz Depth: 20 % to 99% Depth: 5% to 20% 2.3 % + 1 digit 0.58 % 2.9 % 1.7 % 5.2 % 8902A Measuring Receiver N5531S MMR System with N5532B Frequency Modulation – Measure Rate: 0.02 to 10 kHz Rate: 0.05 to 200 kHz ≤ 40kHz peak (0.25 to 10) MHz ≤ 400kHz peak (0.01 to 26.5) GHz 1.2 % Deviation 1.2 % Deviation N5531S MMR System with N5532B Phase Modulation – Measure 100 kHz to 6.6 GHz (6.6 to 13.2) GHz (13.2 to 26.5) GHz > 0.7 Rad > 0.3 to 0.7 Rad > 2.0 Rad > 0.6 to 2.0 Rad > 4.0 Rad > 1.2 to 4.0 Rad 1.6 % Deviation 3.7 % Deviation 1.3 % Deviation 3.5 % Deviation 1.2 % Deviation 3.5 % Deviation N5531S MMR System with N5532B
18--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.01) Revised 12/17/2025 Page 18 of 23 Parameter/Equipment Range CMC7, 4, 5, 7 (±) Comments Single Sideband Phase Noise (SSB) – Measure CW Frequency: 10MHz to 26.5 GHz Offset from CW: 100Hz to 1 MHz 1.9 dB Keysight E4440A w/ N5532B-526 IV. Mechanical Parameter/Equipment Range CMC2, 5, 7 (±) Comments Acceleration & Vibration Amplitude Response (5 to 9) Hz (10 to 99) Hz 100 Hz (101 to 920) Hz (921 to 5000) Hz (5 to 10) kHz (10 to 15) kHz (15 to 20) kHz 2.2 % 1.7 % 1.3 % 1.4 % 1.7 % 2.2 % 2.8 % 3.5 % Modal Shop 9155 System using Back- to-Back Calibration Method Pressure – Measure & Measuring Equipment Pneumatic Pneumatic Hydraulic (-2.2 to 2.2) psig (0 to 15) psig (-14.7 to 60) psig Up to 200 psig Up to 500 psig Up to 1000 psig (0 to 34) inHg (50 to 10 000) psi (0 to 30 000) psi 0.000 12 psi 0.0004 psi 0.0090 psi 0.024 psi 0.060 psi 0.13 psi 0.012 inHg 0.0093 % 35 PSIG + 3.0 µPSIG/PSIG Fluke PPC3 pressure calibrator Mensor CPC 6000 Mensor CPC 6000 Deadweight tester Additel ADT672
10000000 to 26500000000 Hz
19

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.01) Revised 12/17/2025 Page 19 of 23 Parameter/Equipment Range CMC8, 4, 5, 7 (±) Comments Pressure – Field³, Measure & Measuring Equipment Hydraulic Pneumatic (5 to 10 000) psig Up to 1 psig Up to 5 psig Up to 30 psig Up to 100 psig Up to 300 psig Up to 1000 psig Up to 5000 psig 0.12 % 0.0012 psi 0.04 psi 0.018 psi 0.12 psi 0.17 psi 0.59 psi 4.7 psi Deadweight tester Fluke modules Scales & Balances3 – Linearity Repeatability Scales & Balances3 0.01 mg to 42 g (43 to 210) g 210 g to 5.1 kg (5.1 to 30) kg 0.01 mg to 42 g (43 to 210) g 210 g to 5.1 kg (5.1 to 30) kg (0 to 1500) lb 0.000 21 g 0.000 25 g 0.0028 g 0.028 g 0.000 028 g 0.000 14 g 0.019 g 0.000 26 kg 0.0058 lbf + 0.0004 lbf/lbf Class 00, Class 0 & Class 1 weights Class F weights Mass – Measure 0.01 mg to 42 g (43 to 210) g 210 g to 6 kg (6 to 30) kg 0.000 03 g + 0.36 µg/g 0.000 15 g + 0.08 µg/g 0.018 g + 1.9 µg/g 0.17 g + 0.8 mg/g Analytical balances Top loading balances Torque – Measure 0.5 ozf·in to 2000 lbf·ft (500 to 5000) lbf·ft 0.3 % 0.5 % Torque transducers Torque3 – Measure 5 lbf·in to 600 lbf·ft 0.35 % Torque transducers Torque Transducers (0.5 to 400) ozf·in (4 to 150) lbf·in (150 to 400) lbf·in (10 to 2000) lbf·ft 0.05 % 0.05 % 0.06 % 0.05 % Torque arms Class F weights
20-Magnesium; Mag/Aluminum; Aluminum
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.01) Revised 12/17/2025 Page 20 of 23 Parameter/Equipment Range CMC2, 5, 7 (±) Comments Force Measurement3' Compression & Tension Compression Only (1 to 10) lbf (10 to 100) lbf (100 to 500) lbf (500 to 1000) lbf (1000 to 5000) lbf (5000 to 10 000) lbf (10 000 to 50 000) lbf (50 000 to 500 000) lbf 0.0058 lbf + 15 µlbf/ lbf 0.0058 lbf + 34 µlbf / lbf 0.053 lbf + 58 µlbf / lbf 0.57 lbf + 20 µlbf / lbf 5.8 lbf + 33 µlbf / lbf 12 lbf + 24 µlbf / lbf 57 lbf + 74 µlbf / lbf 210 lbf + 620 µlbf / lbf Load cells, Class F, Class 1 weights Load cells Force – Measure & Measuring Equipment Compression Tension (1 to 1000) lbf (65 to 6500) lbf (6500 to 50 000) lbf (1 to 1000) lbf (65 to 6500) lbf (500 to 50 000) lbf 0.12 % 0.98 lbf 7.3 lbf 0.12 % 0.98 lbf 7.3 lbf Class F Weights Proving rings Class F Weights Proving rings Nuclear Density Gauges, Fixed Points – Density3 Magnesium Mag/Aluminum Aluminum 110.45 lb/ft 3 139.20 lb/ft3 167.70 lb/ft3 1.2 lb/ft 3 1.6 lb/ft3 1.9 lb/ft3 Density blocks Nuclear Density Gauges, Fixed Points – Moisture³ Up to 35 lb/ft3 1.1 lb/ft3 Moisture blocks V. Thermodynamics Parameter/Equipment Range CMC2, 5, 7 (±) Comments Thermometers3 (-80 to -20) °C (-20 to 100) °C (100 to 400) °C (400 to 650) °C 0.012 °C 0.015 °C 0.038 °C 0.040 °C Liquid bath Dry block/PRT
See scope document
21AMS2750-See scope document
22

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.01) Revised 12/17/2025 Page 22 of 23 V. Time & Frequency Parameter/Equipment Range CMC2, 7 (±) Comments Stopwatches/Timers3 Up to 30 days 0.037 s/day Timometer Tachometer3 – Non-contact Contact (0 to 100 000) RPM (0 to 1500) RPM 0.062 RPM + 0.000 005 6 RPM/RPM 0.13 RPM + 0.0014 RPM/RPM 33250A Function Generator & LED strobe. Reference Tachometer Comparison Frequency – Measure3 (0 to 200) MHz 50 MHz to 26.5 GHz 1.2 parts in 107 Hz/Hz 1.2 parts in 107 Hz/Hz Agilent 53151A Agilent 53132A Frequency – Measuring Equipment 10 MHz DC to 4 GHz (4 to 26.5) GHz 3.4 parts in 109 MHz 5.8 parts in 108 Hz/Hz 5.8 parts in 108 Hz/Hz Agilent 33120A, 4410A GPS Fluke 96270A w/Leveling Head & Microwave Output Frequency – Measuring Equipment3 10 MHz DC to 4 GHz (4 to 26.5) GHz 6 parts in 1010 Hz/Hz 5.8 parts in 108 Hz/Hz 5.8 parts in 108 Hz/Hz 4410A GPS Frequency Standard Fluke 96270A w/Leveling Head & Microwave Output _______________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.
23

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1892.01) Revised 12/17/2025 Page 23 of 23 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the Calibration and Measurement Capability Uncertainty (CMC) found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, L is the numerical values of the nominal length of the device measured in inches, R is the numerical value of the resolution of the device in microinches, and D is the diameter of the device in inches 5 In the statement of CMC, a % denotes a percent of reading unless otherwise noted. 6 The measurands stated are generated using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure the measurand in the ranges indicated. CMC's are expressed as either a specific value that covers the full range or as a fraction/percentage of the reading plus a fixed floor specification. 7 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter 8 This scope meets A2LA’s P112 Flexible Scope Policy.
24ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.