ARPA Abruzzo - Agenzia Regionale per la Protezione Ambientale - Distretto Provinciale di Teramo
Via Isidoro e Lepido Facii, snc, Zona Industriale Servizi, 64100, Sant'Atto, Italy
Visit website- Accredited standards
- 14
- ACCREDIA certificate
- 1
- Sites in our directory
- 3
What this lab is accredited for
Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 14 standard numbers and the 12 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO11
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
ISO 7027-1Water quality - Determination of turbidity - Part 1: Quantitative methods
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 9308-2Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 2: Most probable number method
ISO 10304-1Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 1: Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate
ISO 11465Sludge and solid environmental matrices - Determination of dry residue or water content and calculation of the dry matter fraction on a mass basis
ISO 14189Water quality - Enumeration of Clostridium perfringens - Method using membrane filtration
ISO 14911Water quality - Determination of dissolved Li+, Na+, NH4+, K+, Mn2+, Ca2+, Mg2+, Sr2+ and Ba2+ using ion chromatography - Method for water and waste water
ISO 15680Water quality - Gas-chromatographic determination of a number of monocyclic aromatic hydrocarbons, naphthalene and several chlorinated compounds using purge-and-trap and thermal desorption
ISO 15705Water quality - Determination of the chemical oxygen demand index (ST-COD) - Small-scale sealed-tube methodExclusion
Limits written next to it
ISO 15705:2002 - escluso/except Cap
ISO 15705:2002 - escluso/except Cap. 10.3
ISO 16266Water quality - Detection and enumeration of Pseudomonas aeruginosa - Method by membrane filtration
Other standards3
AOAC 2012.01
APAT CNR IRSA 7030 F Man 29 2003
EN 26461-2Water quality - Detection and enumeration of the spores of sulfite-reducing anaerobes (clostridia) - Part 2: Method by membrane filtration
Rapporti ISTISAN 2007/31 pag 126; Met ISS CBB006; UNI EN ISO 7027-1:2016; UNI EN ISO 9308-2:2014; UNI EN ISO 6222:2001; ISO 14189:2013; UNI EN ISO 7899-2:2003; UNI EN ISO 14911:2001; UNI EN ISO 10304-1:2009; UNI EN ISO 15680:2005
Rapporti ISTISAN 2007/31 pag 68 Met ISS BCA023; Rapporti ISTISAN 2019/07 pag 43 Met ISS CAC015 - solo/only Metodo UHPLC Parte B; AFNOR IDX 33/04-02/15; APAT CNR IRSA 7030 F Man 29 2003; ISO 15705:2002 - escluso/except Cap. 10.3; UNI EN 26461-2:1994; UNI EN ISO 16266:2008; DM 10/02/2015 GU n 50 02/03/2015 All IV Par 2.5; AOAC 2012.01 2016; DM 06/09/1994 GU n 288 10/12/1994 All 2 Met A; DM 06/09/1994 GU n 288 10/12/1994 All 3; ISO 11465:1993/Cor 1:1994; DM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met II.1
Read from the scope as published by ACCREDIA. Register refreshed 2026-11-20.
Scope as published by ACCREDIA
3 lines
ISO/IEC 17025
Active00566
Accredited scope, certificate 00566
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Rapporti ISTISAN 2007/31 pag 126; Met ISS CBB006; UNI EN ISO 7027-1:2016; UNI EN ISO 9308-2:2014; UNI EN ISO 6222:2001; ISO 14189:2013; UNI EN ISO 7899-2:2003; UNI EN ISO 14911:2001; UNI EN ISO 10304-1:2009; UNI EN ISO 15680:2005 | Drinking water | - |
| 2 | Rapporti ISTISAN 2007/31 pag 68 Met ISS BCA023; Rapporti ISTISAN 2019/07 pag 43 Met ISS CAC015 - solo/only Metodo UHPLC Parte B; AFNOR IDX 33/04-02/15; APAT CNR IRSA 7030 F Man 29 2003; ISO 15705:2002 - escluso/except Cap. 10.3; UNI EN 26461-2:1994; UNI EN ISO 16266:2008; DM 10/02/2015 GU n 50 02/03/2015 All IV Par 2.5; AOAC 2012.01 2016; DM 06/09/1994 GU n 288 10/12/1994 All 2 Met A; DM 06/09/1994 GU n 288 10/12/1994 All 3; ISO 11465:1993/Cor 1:1994; DM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met II.1 | Drinking water | - |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. ARPA Abruzzo – Agenzia Regionale per la Protezione Ambientale –
Distretto Provinciale di Teramo
UNI CEI EN ISO/IEC 17025:2018
Allegato al certificato di accreditamento n. 00566 rev. 8 del 06/02/2025
Piazza Martiri Pennesi, 29
64100 Teramo TE
Legenda/Note
Revisione: 28
Sede A
Data: 23/10/2025
pag. 3 di 3
Il simbolo (1), se presente, indica: "Materiale/Prodotto/Matrice" non previsto dal metodo ma assimilabile/The symbol (1), if present, means: Material/Product/Matrix not
provided for by the method but acceptable
Per la definizione della “categoria" di prova indicata nel titolo, si veda il Regolamento Generale ACCREDIA RG-02/For the definition of the test “category” indicated in the title,
see ACCREDIA General Regulation RG-02.
Il QRcode consente di accedere direttamente al sito www.accredia.it per verificare la validità dell'elenco prove e del certificato di accreditamento
rilasciato al laboratorio/The QRcode allows to directly access to the website www.accredia.it to verify the validity of the test list and of the
accreditation certificate issued to the laboratory.
L’eventuale simbolo “X” riportato nella colonna “O&I” indica che il laboratorio è accreditato anche per fornire opinioni e interpretazioni basate sui
risultati delle specifiche prove contrassegnate/Any "X" symbol in the "O&I" column indicates that the laboratory is also accredited to provide opinions
and interpretations based on the results of the specific marked tests.
L'eventuale simbolo (*) indica che è attiva una sospensione dell’accreditamento per la specifica attività riportata a fianco/Any symbol (*) indicates that
a suspension of accreditation is active for the specific activity shown next to it. | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Via Isidoro e Lepido Facii, snc, Zona Industriale Servizi, Sant'Atto, 64100, IT
42.70743, 13.80767
Open in MapsOther Locations
2 other sites in this organization
Labs with overlapping accredited scope in Italy
- GEOCHIMGualdo Tadino · ~102 kmACCREDIAShares 2 accredited methods and materialsAPAT CNR IRSA 7030 F Man 29 2003Drinking water
- LAB Ambiente e SicurezzaRipalimosani · ~141 kmACCREDIAShares 2 accredited methods and materialsAPAT CNR IRSA 7030 F Man 29 2003Drinking water
- TecnoLab AlimentareForlì · ~221 kmACCREDIAShares 2 accredited methods and materialsEN ISO 7027-1:2016Drinking water
- ANALISISAngri · ~228 kmACCREDIAShares 2 accredited methods and materialsAPAT CNR IRSA 7030 F Man 29 2003Drinking water
- Laboratorio Analisi Dr.ssa Antonia Console S.r.l. a socio unicoBari · ~310 kmACCREDIAShares 2 accredited methods and materialsAPAT CNR IRSA 7030 F Man 29 2003Drinking water
Accreditation data refreshed from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.