Carcoustics Tech Center North America
1400 Durant Dr., 48843, Howell, MI, United States
Visit website- Accredited standards
- 8
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 8 standard numbers and the 7 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM D3574Standard Test Methods for Flexible Cellular Materials - Slab, Bonded, and Molded Polyurethane Foams
IEC 60695-2-11
ISO 527-3Plastics - Determination of tensile properties - Part 3: Test conditions for films and sheets
ISO 845Cellular plastics and rubbers - Determination of apparent density
ISO 1798Flexible cellular polymeric materials - Determination of tensile strength and elongation at break
ISO 2440Flexible and rigid cellular polymeric materials - Accelerated ageing tests
ISO 3386-1Polymeric materials, cellular flexible - Determination of stress-strain characteristics in compression - Part 1: Low-density materials
ISO 3795Road vehicles, and tractors and machinery for agriculture and forestry - Determination of burning behaviour of interior materials
ASTM D3574; ISO 2440; ISO 527-3; ISO 1798; ISO 3386-1
ISO/IEC 17025:2017; ISO 845; ISO 3795; IEC 17025; IEC 60695-2-11
Read from the A2LA scope document we downloaded on 2025-12-02. Register refreshed 2026-11-06.
Scope as published by A2LA
3 lines
ISO/IEC 17025
Active6105.01
The scope document we hold says it is valid until 2027-01-31.
Accredited scope, certificate 6105.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ISO 845; ISO 3795; IEC 17025; IEC 60695-2-11 | Plastics | - |
| 2 | ASTM D3574; ISO 2440; ISO 527-3; ISO 1798; ISO 3386-1 | Plastics | - |
| 3 | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- John J Farber Technology and Innovation CenterRichmond, IN · ~320 kmA2LAShares 2 accredited methods and materialsISO 3795Plastics
- Advanced Composites, Inc. Tennessee Facility - EngineeringNashville, TN · ~763 kmA2LAShares 2 accredited methods and materialsISO 3795Plastics
- ACI PlasticsFlint, MI · ~53 kmA2LAShares 1 accredited materialPlastics
- Michigan Testing InstituteSterling Heights, MI · ~78 kmA2LAShares 1 accredited materialPlastics
- Ghesquiere Plastic TestingHarper Woods, MI · ~89 kmA2LAShares 1 accredited materialPlastics
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.