UL International
Admiral-Rosendahl-Straße 9, 63263, Neu-Isenburg, Germany
Visit website- Scope lines
- 9
- DAKKS certificates
- 2
- Sites in our directory
- 2
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 9 scope lines.
DAKKS certificate D-PL-11095-01-00 · 2 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018 | - | - |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. This accreditation certificate is the property of the German Accreditation Body
The Deutsche Akkreditierungsstelle GmbH (DAkkS) is the entrusted national accreditation body of the
Federal Republic of Germany according to § 8 section 1 AkkStelleG in conjunction with § 1 section 1
AkkStelleGBV. DAkkS is designated as the national accreditation authority by Germany according to
Art. 4 Para. 4 of Regulation (EC) 765/2008 and clause 4.7 of DIN EN ISO/IEC 17000.
Pursuant to Art. 11 section 2 of Regulation (EC) 765/2008, the accreditation certificate shall be recognised as
equivalent by the national authorities within the scope of this Regulation as well as by the
WTO member states that have committed themselves in bilateral or multilateral mutual agreements to
recognise the certificates of accreditation bodies that are members of ILAC or IAF as equivalent.
DAkkS is a signatory to the multilateral agreements for mutual recognition of the European co-operation for
Accreditation (EA), International Accreditation Forum (IAF) and International Laboratory Accreditation Co-
operation (ILAC).
The up-to-date state of membership can be retrieved from the following websites:
EA: www.european-accreditation.org
ILAC: www.ilac.org
IAF: www.iaf.nu
Deutsche Akkreditierungsstelle GmbH
Office Berlin
Spittelmarkt 10
10117 Berlin | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
DAKKS certificate D-PL-11095-01-01 · 7 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018 | - | - |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. Annex to the Accreditation Certificate D-PL-11095-01-01
Valid from : 13.02.2026
Date of issue : 13.02.2026 Page 2 of 7
This document is a translation. The definitive version is the original German annex to the accreditation certificate.
Test in the fields:
1 Wind Energy Generation Systems .................. ................................................................................... 3
1.1 Determination of the Power Performance Characte ristic Curve and standardized Energy Yields 3
1.2 Accomplishment and Evaluation of Wind Measureme nts ............................................................ 3
1.3 Verification of Remote Sensing Devices ........ ................................................................................ 3
1.4 Load Measurements ...................................................................................................................... 4
2 Power Generating Units and Plants ............... .................................................................................... 4
2.1 Grid Integration .............................................................................................................................. 4
Flexible Scope of Accreditation:
Within the indicated test areas the testing laboratory is permitted without being required to prior
inform and obtain approval from DAkkS
[Flex B] to have the free choice from standardised or equivalent test methods.
The testing laboratory has an up-to-date list of all test methods within the flexible scope of
accreditation. The list is publicly available on the website of the testing laboratory. | ||
| 3 | - | wind energy generation systemsShow page textExtracted from the scope document; tables may not line up. View scope for the original. Annex to the Accreditation Certificate D-PL-11095-01-01
Valid from : 13.02.2026
Date of issue : 13.02.2026 Page 3 of 7
This document is a translation. The definitive version is the original German annex to the accreditation certificate.
1 Wind Energy Generation Systems
1.1 Determination of the Power Performance Characteristic Curve and standardized Energy Yields
Scope
Nr.
[Flex Cat.]
or
Issue
Type of Test / Method / Procedure / Title of Standard Restrictions /
Field of Testing /
Parameter
1.1.1 [Flex B]
Determination of the Power Performance Characteristic Curve
and Standardized Energy Yields
/
Measurement of relevant meteorological and operational data
/
Wind measurements using anemometer and wind vane, LIDAR-
or SODAR- remote sensing devices,
measurement of electrical power using current and voltage
measurements
N/A
1.2 Accomplishment and Evaluation of Wind Measurements
Scope
Nr.
[Flex Cat.]
or
Issue
Type of Test / Method / Procedure / Title of Standard Restrictions /
Field of Testing /
Parameter
1.2.1 [Flex B]
Measurement of wind speed and wind direction using
anemometer and wind vane, LIDAR- or SODAR- remote sensing
devices
N/A
1.3 Verification of Remote Sensing Devices
Scope
Nr.
[Flex Cat.]
or
Issue
Type of Test / Method / Procedure / Title of Standard Restrictions /
Field of Testing /
Parameter
1.3.1 [Flex B]
Verification of ground based LIDAR- or SODAR - remote sensing
devices
N/A | - |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. Annex to the Accreditation Certificate D-PL-11095-01-01
Valid from : 13.02.2026
Date of issue : 13.02.2026 Page 4 of 7
This document is a translation. The definitive version is the original German annex to the accreditation certificate.
1.4 Load Measurements
Scope
Nr.
[Flex Cat.]
or
Issue
Type of Test / Method / Procedure / Title of Standard Restrictions /
Field of Testing /
Parameter
1.4.1 [Flex B] Measurement of Stresses and Loads
/
Electrical, optical and mechanical measurement of mechanical
quantities
/
Measurement of strain, measurement of force, measurement of
bending moment and torque, measurement of acceleration,
measurement of displacement, measurement of angles,
measurement of pulses and frequencies,
proximity measurements temperature measurement
Only the sections of
the respective
standard that are
relevant to the test.
For details, see the list
of all test methods
within the flexible
scope of accreditation.
2 Power Generating Units and Plants
2.1 Grid Integration
Scope
Nr.
[Flex Cat.]
or
Issue
Type of Test / Method /
Procedure / Title of Standard
Restrictions /
Test Area /
Parameter
2.1.1 [Flex B] Determination of Electrical Characteri stics of Power Generating
Units and Power Generating Systems (PGU and PGS), Energy
Storage Systems as well as Their Components and Grid Integration
/
*Testing of grid disturbances (power quality effects);
*Measurement of active power output and reactive power
provision;
*Measurement of control performance characteristics;
*Measurement of fault ride-through (FRT) capability
*Validation measurements;
/
Current and voltage measurements;
measurement of auxiliary signals;
measurement of setpoint signals (analog or digital)
Only the sections of
the respective
standard that are
relevant to the test.
For details, see the list
of all test methods
within the flexible
scope of accreditation. | ||
| 5 | NTS | Power park modules (PPM); Synchronous or asynchronous power generating modules (SPGM) | - |
| 6 | NTS; NTS SENP | Power park controllers (PPC); Synchronous Compensator; Power park modules (PPM) connected through power electronics like wind turbines, photovoltaic inverter, storage inverter systems, fuel cells, etc.; Synchronous or asynchronous power generating modules (SPGM) like cogeneration combined heat and power, combustion engines, combustion turbines, hydropower, etc. | - |
| 7 | DIN; EN; IEC; ISO | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
1 other site in this organization
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.