Registers refreshed 2026-11-08.See refresh dates
United States

Schneider Electric Systems USA

70 Mechanic Street, 02035, Foxboro, MA, United States

Visit website
A2LA 6418.01A2LA 6418.02ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
44
A2LA certificates
2
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 44 standard numbers and the 31 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 61000 series20
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-3-11Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current ≤ 75 A and subject to conditional connection
IEC 61000-3-12Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase

Certificate says EN 61000-3-12. Probably the same standard; not checked against the EN document.

IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-4-16
Show all 20
IEC 61000-4-20
IEC 61000-4-21
IEC 61000-4-22
IEC 61000-4-29Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
IEC 61000-4-34
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environmentsSome clauses

Limits written next to it

IEC 61000-6-4 (only CISPR 11)

Some clauses. Written next to it on line 2 of A2LA certificate 6418.01.

IEC 60068 series10
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)

Certificate says EN 60068-2-6. Probably the same standard; not checked against the EN document.

IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock

Certificate says EN 60068-2-27. Probably the same standard; not checked against the EN document.

IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-31Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens
IEC 60068-2-38Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance

Certificate says EN 60068-2-64. Probably the same standard; not checked against the EN document.

IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
IEC 61326 series5
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements

Certificate says EN 61326-1. Probably the same standard; not checked against the EN document.

IEC 61326-2-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications
IEC 61326-2-3Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning
IEC 61326-2-5
IEC 61326-3-1
IEC4
IEC 60240-2
IEC 60529Degrees of protection provided by enclosures (IP Code)
IEC 61010-1Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
IEC 61131-2
IEC 60079 series4
IEC 60079-0
IEC 60079-7
IEC 60079-11
IEC 60079-15
Other standards1
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement

Read from the A2LA scope documents we downloaded on 2026-03-14 and 2026-10-27. Register refreshed 2026-11-06.

Scope as published by A2LA

8 lines
A2LA

ISO/IEC 17025

Active

6418.01

The scope document we hold says it is valid until 2027-07-31.

View scope

Accredited scope, certificate 6418.01

LineMethodMatrixRange
1CISPR 11; EN 61000-4-2; IEC 61000-4-2; EN 61000-4-3; IEC 61000-4-3; EN 61000-4-4; IEC 61000-4-4; EN 61000-4-5; IEC 61000-4-5; EN 61000-4-6; IEC 61000-4-6; EN 61000-4-8; IEC 61000-4-8; EN 61000-4-11; IEC 61000-4-11; EN 61000-4-16; IEC 61000-4-16-See scope document
2EN 61000-4-29; IEC 61000-4-29; EN 61326-1; IEC 61326-1; EN 61000-3-2; IEC 61000-3-2; EN 61000-3-3; IEC 61000-3-3; EN 61000-3-11; IEC 61000-3-11; EN 61000-3-12; IEC 61000-3-12; EN 61131-2; IEC 61131-2; EN 61000-4-2; IEC 61000-4-2; EN 61000-4-3; IEC 61000-4-3; EN 61000-4-4; IEC 61000-4-4; EN 61000-4-5; IEC 61000-4-5; EN 61000-4-6; IEC 61000-4-6; EN 61000-4-8; IEC 61000-4-8; EN 61000-4-11; IEC 61000-4-11; EN 61326-2-1; IEC 61326-2-1; EN 61326-2-3; IEC 61326-2-3; EN 61326-2-5; IEC 61326-2-5; EN 61326-3-1; IEC 61326-3-1; EN 61000-4-34; IEC 61000-4-34; IEC 61000-6-1; IEC 61000-4-20; IEC 61000-4-21; IEC 61000-4-22; IEC 61000-4-34; IEC 61000-6-2; IEC 61000-6-4--
3A2LA R101--
4

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited SCHNEIDER ELECTRIC SYSTEMS USA, INC. Foxboro, MA for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 11th day of August 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 6418.01 Valid to July 31, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

A2LA

ISO/IEC 17025

Active

6418.02

The scope document we hold says it is valid until 2027-07-31.

View scope

Accredited scope, certificate 6418.02

LineMethodMatrixRange
1IEC 60068-2-1; IEC 60068-2-2; IEC 60068-2-6; IEC 60068-2-14; IEC 60068-2-27; IEC 60068-2-30; IEC 60068-2-31; IEC 60068-2-38; IEC 60068-2-78; IEC 60068-2-64; IEC 60079-0--
2IEC 60079-11; IEC 60079-15; IEC 61010-1; IEC 60240-2; CES 288:8; CES 288:49; ISTA 3A; CES 288:56; NEMA 250, Clause 5.7; NEMA 250, Clause 5.11; IEC 60529, Clause 14.2.6; IEC 60529, Clause 14.2.7; CAN/CSA 22.2 NO. 61010-1-12, Clauses 4.1. 4.2, & 4.3; CES 288:75; EN 60079-0, Clauses 26.5 & 26.5.1--
3EN 60079-7; CSA-C22.2 No. 213; CSA-C22.2 No. 61010-2-201; IEC 60079-7; EN 60079-15; ISA-12.12.01; ISA-12.12.01/CSA-C22.2 No. 213; UL 61010-1/CSA-C22.2 No. 61010-1; UL 61010-2-201--
4ISO/IEC 17025:2017--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

70 Mechanic Street, Foxboro, MA, 02035, US

42.09535, -71.26163

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.