Registers refreshed 2026-11-20.See refresh dates
United States

Tektronix, Inc. - N. Billerica Test

7 Sterling Road, 01862, North Billerica, MA, United States

Visit website
A2LA 2357.23ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
14
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 14 standard numbers and the 8 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 60068 series10
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-13
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-29
IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance

Certificate says EN 60068-2-64. Probably the same standard; not checked against the EN document.

IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
ASTM4
ASTM D4169
ASTM D4332
ASTM D6653
ASTM D7386

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

7 lines
A2LA

ISO/IEC 17025

Active

2357.23

The scope document we hold says it is valid until 2027-03-31.

View scope

Accredited scope, certificate 2357.23

LineMethodMatrixRange
1MIL-STD-810C; MIL-STD-810D; MIL-STD-810E; MIL-STD-810F; MIL-STD-810G; MIL-STD-810G w/ Change 1; MIL-STD-810H; MIL-STD-202G; MIL-STD-750E; MIL-STD-883-1; RTCA/DO-160E; RTCA/DO-160F; RTCA/DO-160G; IEC 60068-2-27; IEC 60068-2-29; IEC 60068-2-6Electronic and Electro-Mechanical DevicesSee scope document
2MIL-STD-883-1: Method 2007; RTCA/DO-160E (Section 8); RTCA/DO-160F (Section 8); RTCA/DO-160G (Section 8); MIL-STD-167-1; MIL-STD 167-1; ISTA, ASTM D4169, Fixed Displacement, Sine, and Random; IEC 60068-2-6; IEC 60068-2-64; MIL-STD-202G: Method 105; MIL-STD-750E: Method 1001; MIL-STD-810C: Method 500.1; MIL-STD-810D: Method 500.2; MIL-STD-810E: Method 500.3; MIL-STD-810F: Method 500.4; MIL-STD-810G: Method 500.5; MIL-STD-810G w/ Change 1, 500.6; MIL-STD-810H: 500.6; IEC 60068-2-13; ASTM D4169; ASTM D6653; RTCA/DO-160E (Section 4); RTCA/DO-160F; RTCA/DO-160G; MIL-STD-202G: Method 109; MIL-STD-810C: Method 511.1; MIL-STD-810D: Method 511.2; MIL-STD-810E: Method 511.3; MIL-STD-810F: Method 511.4; MIL-STD-810G: Method 511.5; MIL-STD-810G w/ Change 1, Method 511.6; MIL-STD-810H: Method 511.7; MIL-STD-202: Method 109B; RTCA/DO-160E (Section 9.0); RTCA/DO-160F; RTCA/DO-160G-5 to 3000 Hz
3MIL-STD-810C: Method 501.1; MIL-STD-810D: Method 501.2; MIL-STD-810E: Method 501.3; MIL-STD-810F: Method 501.4; MIL-STD-810G: Method 501.5; MIL-STD-810G w/ Change 1, Method 501.6; MIL-STD-810H: Method 501.7; MIL-STD-810C: Method 502.1; MIL-STD-810D: Method 502.2; MIL-STD-810E: Method 502.3; MIL-STD-810F: Method 502.4; MIL-STD-810G: Method 502.5; MIL-STD-810G w/ Change 1, Method 502.6; MIL-STD-810H: Method 502.7; IEC 60068-2-1; IEC 60068-2-2; IEC 60068-2-14; RTCA/DO-160E; RTCA/DO-160F; RTCA/DO-160G; MIL-STD-202G: Method 107; MIL-STD-750E: Method 1051; MIL-STD-810C: Method 503.1; MIL-STD-810D: Method 503.2; MIL-STD-810E: Method 503.3; MIL-STD-810F: Method 503.4; MIL-STD-810G: Method 503.5; MIL-STD-810G w/ Change 1, Method 503.6; MIL-STD-810H: Method 503.7; MIL-STD-883-1: Method 1010; RTCA/DO-160E (Section 5); RTCA/DO-160F (Section 5); RTCA/DO-160G; MIL-STD-202G: Methods 103 and 106; MIL-STD-750E: Method 1021; MIL-STD-810C: Method 507.1; MIL-STD-810D: Method 507.2; MIL-STD-810E: Method 507.3; MIL-STD-810F: Method 507.4; MIL-STD-810G: Method 507.5; MIL-STD-810G w/ Change 1, Method 507.6; MIL-STD-810H: Method 507.6; MIL-STD-202: Method 103B; MIL-STD-883-1: Method 1004; IEC 60068-2-30; IEC 60068-2-78; ISTA ASTM D4169; ISTA/ASTM D4332; RTCA/DO-160E (6.0); RTCA/DO-160F; RTCA/DO-160G; ISTA; ASTM D4169; ASTM D7386; MIL-STD-810G: Method 516--75 to 190 ºC
4MIL-STD-810C: Method 516.2; MIL-STD-810D: Method 516.3; MIL-STD-810E: Method 516.4; MIL-STD-810F: Method 516.5; MIL-STD-810G: Method 516.6; MIL-STD-810G w/ Change 1, 516.7; MIL-STD-810H: 516.8; MIL-STD-202G: Method 213B; MIL-STD-750E: Method 2016; MIL-STD-883-1: Method 2002; RTCA/DO-160E (Section 7); RTCA/DO-160F (Section 7); RTCA/DO-160G (Section 7); IEC 60068-2-27 (2008-02, Edition 4.0); IEC 60068-2-29; MIL-STD-810C: Method 514.2; MIL-STD-810D: Method 514.3; MIL-STD-810E: Method 514.4; MIL-STD-810F: Method 514.5; MIL-STD-810G: Method 514.6; MIL-STD-810G w/ Change 1, 514.7; MIL-STD-810H: 514.8; MIL-STD-810D: Method 520.0; MIL-STD-810E: Method 520.1; MIL-STD-810F: Method 520.2; MIL-STD-810G: Method 520.3; MIL-STD-810G w/ Change 1, 520.4; MIL-STD-810H: 520.5; MIL-STD-810G: Method 520.5; IEC 60068-2-6 (2007-12, Edition 7.0); MIL-STD-202G: Methods 201A, 204D, and 214A; MIL-STD-750E: Methods 2046 and 2056; MIL-STD-883-1: Method 2007; RTCA/DO-160E (Section 8); RTCA/DO-160F (Section 8); RTCA/DO-160G (Section 8); MIL-STD-167-1; MIL-STD 167-1; ISTA, ASTM D4169, Fixed Displacement, Sine, and Random; IEC 60068-2-6; IEC 60068-2-64-5 to 3000 Hz
5MIL-STD-883-1: Method 200; MIL-STD-202G: Method 212 TC, B, and C; MIL-STD-750E: Method 2006; MIL-STD-810C: Method 513.2; MIL-STD-810D: Method 513.3; MIL-STD-810E: Method 513.4; MIL-STD-810F: Method 513.5; MIL-STD-810G: Method 513.6; MIL-STD-810G w/ Change 1, 513.7; MIL-STD-810H: 513.8; MIL-STD-202G: Method 212A; RTCA/DO-160E; RTCA/DO-160F; RTCA/DO-160G; MIL-STD-202G: Method 105; MIL-STD-750E: Method 1001; MIL-STD-810C, Method 500.1; MIL-STD-810D, Method 500.2; MIL-STD-810E, Method 500.3; MIL-STD-810F, Method 500.4; MIL-STD-810G, Method 500.5; MIL-STD-810G w/ Change 1, 500.6; MIL-STD-810H, 500.6; IEC 60068-2-13; ASTM D4169; ASTM D6653; RTCA/DO-160E Section 4; RTCA/DO-160F; RTCA/DO-160G; MIL-STD-810C: Method 501.1; MIL-STD-810D: Method 501.2; MIL-STD-810E: Method 501.3; MIL-STD-810F: Method 501.4; MIL-STD-810G: Method 501.5; MIL-STD-810G w/ Change 1, Method 501.6; MIL-STD-810H: Method 501.7; MIL-STD-810C: Method 502.1; MIL-STD-810D: Method 502.2; MIL-STD-810E: Method 502.3; MIL-STD-810F: Method 502.4; MIL-STD-810G: Method 502.5; MIL-STD-810G w/ Change 1, Method 502.6; MIL-STD-810H: Method 502.7; IEC 60068-2-1; IEC 60068-2-2; IEC 60068-2-14-1 to 120 g
6MIL-STD-202G: Method 107; MIL-STD-750E: Method 1051; MIL-STD-810C: Method 503.1; MIL-STD-810D: Method 503.2; MIL-STD-810E: Method 503.3; MIL-STD-810F: Method 503.4; MIL-STD-810G: Method 503.5; MIL-STD-810G w/ Change 1, Method 503.6; MIL-STD-810H: Method 503.7; MIL-STD-883-1: Method 1010; RTCA/DO-160E (Section 5); RTCA/DO-160F (Section 5); RTCA/DO-160G; MIL-STD-202G: Methods 103 and 106; MIL-STD-750E: Method 1021; MIL-STD-810C: Method 507.1; MIL-STD-810D: Method 507.2; MIL-STD-810E: Method 507.3; MIL-STD-810F: Method 507.4; MIL-STD-810G: Method 507.5; MIL-STD-810G w/ Change 1, Method 507.6; MIL-STD-810H: Method 507.6; MIL-STD-202: Method 103B; MIL-STD-883-1: Method 1004; IEC 60068-2-30; IEC 60068-2-78; ISTA ASTM D4169; ISTA/ASTM D4332; RTCA/DO-160E (6.0); RTCA/DO-160F; RTCA/DO-160G; ISTA; ASTM D4169; ASTM D7386; MIL-STD-810G: Method 516--75 to 200 ºC
7

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation. Accredited Laboratory A2LA has accredited TEKTRONIX, INC. N. Billerica, MA for technical competence in the field of Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 3rd day of February 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 2357.23 Valid to March 31, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

7 Sterling Road, North Billerica, MA, 01862, US

42.58526, -71.28776

Open in Maps

Accreditation data refreshed from the A2LA register on .