Valle Umbra Servizi
Via Bianca 15 - ZI San Eraclio, 06034, Foligno, Italy
Visit website- Accredited standards
- 6
- ACCREDIA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 6 standard numbers and the 6 official names we hold. When no standard matches, it searches the method text of every scope line.
APAT CNR IRSA 2060 Man 29 2003pH
ISO 9308-2Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 2: Most probable number method
ISO 10304-1Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 1: Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate
ISO 15680Water quality - Gas-chromatographic determination of a number of monocyclic aromatic hydrocarbons, naphthalene and several chlorinated compounds using purge-and-trap and thermal desorption
ISO 16266-2Water quality - Detection and enumeration of Pseudomonas aeruginosa - Part 2: Most probable number method
ISO 17294-2Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Part 2: Determination of selected elements including uranium isotopes
UNI CEI EN ISO/IEC 17025:2018; APAT CNR IRSA 2060 Man 29 2003; UNI EN ISO 15680:2005; UNI EN ISO 17294-2:2023; UNI EN ISO 10304-1:2009; UNI EN ISO 9308-2:2014; AFNOR IDX 33/03-10/13; AFNOR IDX 33/06-06/19; UNI EN ISO 16266-2:2022
Read from the scope as published by ACCREDIA. Register refreshed 2026-11-20.
Scope as published by ACCREDIA
1 line
ISO/IEC 17025
Active01953
Accredited scope, certificate 01953
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | UNI CEI EN ISO/IEC 17025:2018; APAT CNR IRSA 2060 Man 29 2003; UNI EN ISO 15680:2005; UNI EN ISO 17294-2:2023; UNI EN ISO 10304-1:2009; UNI EN ISO 9308-2:2014; AFNOR IDX 33/03-10/13; AFNOR IDX 33/06-06/19; UNI EN ISO 16266-2:2022 | Acque destinate al consumo umano; Drinking waters | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Italy
- &LABPerugia · ~34 kmACCREDIAShares 1 accredited test methodAPAT CNR IRSA 2060 Man 29 2003
- IgienstudioJesi · ~78 kmACCREDIAShares 1 accredited test methodAPAT CNR IRSA 2060 Man 29 2003
- ARGO GROUP S.C.a R.L.Fermo · ~82 kmACCREDIAShares 1 accredited test methodAPAT CNR IRSA 2060 Man 29 2003
- LABOR CHIMICAArezzo · ~91 kmACCREDIAShares 1 accredited test methodAPAT CNR IRSA 2060 Man 29 2003
- ACQUAGESTPesaro · ~107 kmACCREDIAShares 1 accredited test methodAPAT CNR IRSA 2060 Man 29 2003
Accreditation data refreshed from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.