Registers refreshed 2026-11-20.See refresh dates
Germany

KRIWAN Testzentrum

Teslastraße 2, 74670, Forchtenberg, Germany

Visit website
DAKKS D-PL-12091-01-00DAKKS D-PL-12091-01-01DAKKS D-PL-12091-01-02ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
130
DAKKS certificates
3
Site in our directory
1
DAKKS accredited scope

What this lab is accredited for

Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 130 standard numbers and the 78 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 61000 series22
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection

Certificate says EN 61000-3-3. Probably the same standard; not checked against the EN document.

IEC 61000-3-11Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current ≤ 75 A and subject to conditional connection
IEC 61000-3-12Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase

Certificate says EN 61000-3-12. Probably the same standard; not checked against the EN document.

IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test

Certificate says EN 61000-4-2. Probably the same standard; not checked against the EN document.

IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test

Certificate says EN 61000-4-5. Probably the same standard; not checked against the EN document.

IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-4-13Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics including mains signalling at a.c. power port, low frequency immunity tests
Show all 22
IEC 61000-4-20
IEC 61000-4-22
IEC 61000-4-28
IEC 61000-4-29Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
IEC 61000-4-34
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments

Certificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.

IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
IEC 61000-6-7
EN19
EN 1154
EN 1155
EN 1158
EN 12015Electromagnetic compatibility - Product family standard for lifts, escalators and moving walks - Emission
EN 12016
EN 12101-9
EN 12101-10
EN 12895
EN 13309
EN 14604
EN 14637
EN 16034
Show all 19
EN 50121-3-2Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
EN 50121-4Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus
EN 50130-4Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
EN 50130-5
EN 50155Railway applications - Rolling stock - Electronic equipment
EN 50295
EN 50370-2
IEC 60068 series19
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold

Certificate says EN 60068-2-1. Probably the same standard; not checked against the EN document.

IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-5
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)

Certificate says EN 60068-2-6. Probably the same standard; not checked against the EN document.

IEC 60068-2-11Environmental testing - Part 2-11: Tests - Test Ka: Salt mist
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-31Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens
IEC 60068-2-38Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test
IEC 60068-2-42
IEC 60068-2-52Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution)
IEC 60068-2-53
Show all 19
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance

Certificate says EN 60068-2-64. Probably the same standard; not checked against the EN document.

IEC 60068-2-67
IEC 60068-2-75
IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
IEC 60068-2-80Environmental testing - Part 2-80: Tests - Test Fi: Vibration - Mixed mode
IEC 60068-2-273
IEC 60068-2-803
CISPR10
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement

Certificate says EN 55011. Probably the same standard; not checked against the EN document.

CISPR 12Vehicles, boats and devices with internal combustion engines or traction batteries - Radio disturbance characteristics - Limits and methods of measurement for the protection of off-board receivers

Certificate says EN 55012. Probably the same standard; not checked against the EN document.

CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission

Certificate says EN 55014-1. Probably the same standard; not checked against the EN document.

CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard

Certificate says EN 55014-2. Probably the same standard; not checked against the EN document.

CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment

Certificate says EN 55015. Probably the same standard; not checked against the EN document.

CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement

Certificate says EN 55022. Probably the same standard; not checked against the EN document.

CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurement

Certificate says EN 55024. Probably the same standard; not checked against the EN document.

CISPR 25Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of on-board receivers

Certificate says EN 55025. Probably the same standard; not checked against the EN document.

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements

Certificate says EN 55035. Probably the same standard; not checked against the EN document.

EN 54 series10
EN 54-2
EN 54-3
EN 54-4
EN 54-5
EN 54-7
EN 54-11
EN 54-13
EN 54-17
EN 54-18
EN 54-25
IEC9
IEC 60034-5
IEC 60529Degrees of protection provided by enclosures (IP Code)
IEC 60730-1Automatic electrical controls - Part 1: General requirements
IEC 60945Maritime navigation and radiocommunication equipment and systems - General requirements - Methods of testing and required test results
IEC 61131-2
IEC 61373Railway applications - Rolling stock equipment - Shock and vibration tests
IEC 61547Equipment for general lighting purposes - EMC immunity requirements

Certificate says EN 61547. Probably the same standard; not checked against the EN document.

IEC 61800-3Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods for PDS and machine tools
IEC 61800-5-2
ISO9
ISO 6270-1Paints and varnishes - Determination of resistance to humidity - Part 1: Condensation (single-sided exposure)
ISO 6270-2Paints and varnishes - Determination of resistance to humidity - Part 2: Condensation (in-cabinet exposure with heated water reservoir)
ISO 9227Corrosion tests in artificial atmospheres - Salt spray tests
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
ISO 13766-1Earth-moving and building construction machinery - Electromagnetic compatibility (EMC) of machines with internal electrical power supply - Part 1: General EMC requirements under typical electromagnetic environmental conditions
ISO 13766-2Earth-moving and building construction machinery - Electromagnetic compatibility (EMC) of machines with internal electrical power supply - Part 2: Additional EMC requirements for functional safety
ISO 14982Agricultural and forestry machinery - Electromagnetic compatibility - Test methods and acceptance criteriaSome clauses

Limits written next to it

ISO 14982:2009 ohne Kapitel 6

Some clauses. Written next to it on line 34 of DAKKS certificate D-PL-12091-01-01.

ISO 20567-1Paints and varnishes - Determination of stone-chip resistance of coatings - Part 1: Multi-impact testing
ISO 21927-9Smoke and heat control systems - Part 9: Specification for control equipmentSome clauses

Limits written next to it

ISO 21927-9 nur Kapitel 13

Some clauses. Written next to it on line 33 of DAKKS certificate D-PL-12091-01-01.

IEC 61326 series6
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61326-2-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications
IEC 61326-2-2Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems
IEC 61326-2-3Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning
IEC 61326-3-1
IEC 61326-3-2
DIN5
DIN 14676-1
DIN 18232-9
DIN 40050-9
DIN 75200
DIN 75220
IEC 60512 series5
IEC 60512-2-1
IEC 60512-2-2
IEC 60512-3-1
IEC 60512-4-1
IEC 60512-5-1
ISO 11452 series4
ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methodsSome clauses

Limits written next to it

ISO 11452-4:2020 Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods nur Kapitel 6

Some clauses. Written next to it on line 35 of DAKKS certificate D-PL-12091-01-01.

ISO 11452-5Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 5: Stripline
ISO 11452-8Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 8: Immunity to magnetic fields
CISPR 16 series3
CISPR 16-2-1Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements

Certificate says EN 55016-2-1. Probably the same standard; not checked against the EN document.

CISPR 16-2-3Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements

Certificate says EN 55016-2-3. Probably the same standard; not checked against the EN document.

CISPR 16-2-4

Certificate says EN 55016-2-4. Probably the same standard; not checked against the EN document.

ISO 16750 series3
ISO 16750-2Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads
ISO 16750-3Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 3: Mechanical loads
ISO 16750-4Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 4: Climatic loads
ISO 19453 series3
ISO 19453-3Road vehicles - Environmental conditions and testing for electrical and electronic equipment for drive system of electric propulsion vehicles - Part 3: Mechanical loads
ISO 19453-4Road vehicles - Environmental conditions and testing for electrical and electronic equipment for drive system of electric propulsion vehicles - Part 4: Climatic loads
ISO 19453-5Road vehicles - Environmental conditions and testing for electrical and electronic equipment for drive system of electric propulsion vehicles - Part 5: Chemical loadsSome clauses

Limits written next to it

ISO 19453-5:2018-03 Straßenfahrzeuge - Umgebungsbedingungen und Tests für elektrische und elektronische Einrichtungen von Antriebssystemen für Elektrofahrzeuge - Teil 3: Mechanische Beanspruchungen CN 05 0215-1:2017-01 CLAAS Umweltanforderungen für Elektrik- und Elektronikkomponenten ohne Kapitel 4

Some clauses. Written next to it on line 37 of DAKKS certificate D-PL-12091-01-01.

ISO 8092 series3
ISO 8092-2Road vehicles - Connections for on-board electrical wiring harnesses - Part 2: Terminology, test methods and general performance requirements
ISO 8092-3Road vehicles - Connections for on-board electrical wiring harnesses - Part 3: Tabs for multi-pole connections - Dimensions and specific requirements
ISO 8092-4Road vehicles - Connections for on-board electrical wiring harnesses - Part 4: Pins for single- and multi-pole connections - Dimensions and specific requirements

Read from the scope as published by DAKKS. Register refreshed 2026-11-20.

Scope as published by DAKKS

58 lines
DAKKS

ISO/IEC 17025

Active

D-PL-12091-01-00

View scope
DAKKS

ISO/IEC 17025

Active

D-PL-12091-01-01

View scope
DAKKS

ISO/IEC 17025

Active

D-PL-12091-01-02

View scope

Location

Teslastraße 2, Forchtenberg, 74670, DE

49.29211, 9.56463

Open in Maps

Accreditation data refreshed from the DAKKS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.