Certificates and scope
1ISO/IEC 17025
Active01380
Accredited scope, certificate 01380
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | chemical | UNI CEI EN ISO/IEC 17025:2018; ISO 11731:2017; APAT CNR IRSA 2030 Man 29 2003; APAT CNR IRSA 7030 F Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; APAT CNR IRSA 7010 C Man 29 2003; UNI EN ISO 6222:2001; APAT CNR IRSA 3010 A + 3020 Man 29 2003 | Drinking water | - |
| 2 | chemical | APAT CNR IRSA 4030 A2 Man 29 2003; APAT CNR IRSA 3010 A + 3020 Man 29 2003; ISO 15705:2002; ISO 21527-1:2008; UNI EN ISO 4833-1:2022; UNI ISO 16649-2:2010; DM 17/06/2002 GU n 220 19/09/2002 suppl.7 Met III.3; UNI EN 13657:2004 par 6.1, APAT CNR IRSA 3020 Man 29 2003; CNR IRSA 2 Q 64 Vol 2 1984/Notiziario IRSA 2 2008; CNR IRSA 1 Q 64 Vol 3 1985 + APAT CNR IRSA 2060 Man 29 2003; MU 1962-2:06 (escl campionamento/except sampling) | Waste water | - |
| 3 | chemical; biological; materials | APAT CNR IRSA 2100 Man 29 2003; UNI EN ISO 19458:2006; ANPA RTI CTN_RIF 1/2000 Met 3; UNI EN ISO 18593:2018 | Waste water | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Italy
- ASTRA STUDIO CHIMICO ASSOCIATOTeramo · ~149 kmACCREDIAShares 4 accredited methods and materialsAPAT CNR IRSA 2030 Man 29 2003APAT CNR IRSA 4030 A2 Man 29 2003Drinking water
- White Lab srl - L.A.S. Laboratorio Ambiente e saluteNapoli · ~176 kmACCREDIAShares 4 accredited methods and materialsAPAT CNR IRSA 2030 Man 29 2003APAT CNR IRSA 2100 Man 29 2003Drinking water
- EURO QUALITY SYSTEMSNovara · ~523 kmACCREDIAShares 4 accredited methods and materialsAPAT CNR IRSA 2030 Man 29 2003APAT CNR IRSA 2100 Man 29 2003Drinking water
- ECOCONTROLPomezia · ~3 kmACCREDIAShares 3 accredited methods and materialsAPAT CNR IRSA 2100 Man 29 2003Drinking waterWaste water
- AGRI-BIO-ECO Laboratori RiunitiPomezia · ~3 kmACCREDIAShares 3 accredited methods and materialsAPAT CNR IRSA 2100 Man 29 2003Drinking waterWaste water