International Certification Services
1100 Falcon Ave, 55336-3363, Glencoe, MN, United States
Visit website- Accredited standards
- 10
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 10 standard numbers and the 9 official names we hold. When no standard matches, it searches the method text of every scope line.
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ANSI/TIA-603-E
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+2 national
National versions in the same scope
AS CISPR 11national version with changes
KS C 9811national version with changes
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+4 national
National versions in the same scope
AS CISPR 14.1national version with changes
AS/NZS CISPR 14.1national version with changes
CNS 13783-1identical to it
KS C 9814-1national version with changes
CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment+3 national
National versions in the same scope
AS CISPR 15national version with changes
AS/NZS CISPR 15national version with changes
KS C 9815national version with changes
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+3 national
National versions in the same scope
AS/NZS CISPR 32identical to it
KS C 9832national version with changes
VCCI-CISPR 32probably the same standard; matched by number only
FCC PART 15Radio Frequency Devices
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)+1 national
National versions in the same scope
KS C 9610-3-2national version with changes
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection+1 national
National versions in the same scope
KS C 9610-3-3national version with changes
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test+1 national
National versions in the same scope
KS C 9610-4-2national version with changes
CFR 47, FCC Part 15, Subpart B (using ANSI C63.4:2014); ANSI C63.4-2014; CFR 47, FCC Part 18 (using FCC MP-5:1986); CAN/CSA-CEI/IEC CISPR 11; CSA-CISPR 11; AS CISPR 11; ICES-001; ICES-003; ICES-005; CAN/CSA-CISPR 22; CISPR 13; BS EN 55011; EN 55011; CISPR 11; AS CISPR 11; CISPR 11; KS C 9811; CNS 13803; BS EN IEC 55014-1; EN IEC 55014-1; CISPR 14-1; AS/NZS CISPR 14.1; AS CISPR 14.1; CNS 13783-1; J55014-1; CNS 13783-1; KS C9814-1; J55014; BS EN 55015; BS EN IEC 55015; EN 55015; EN IEC 55015; CISPR 15; AS/NZS CISPR 15; AS CISPR 15; CNS 14115; J55015; KS C9815; J55015; CNS 14115; CISPR 22; VCCI-CISPR 32; BS EN 55032; EN 55032; CISPR 32; AS/NZS CISPR 32; KS C 9832; CNS 13439; CNS 13438; BS EN 61000-3-2; BS EN IEC 61000-3-2; IEC 61000-3-2; EN 61000-3-2; EN IEC 61000-3-2; JIS C 61000-3-2; KS C 9610-3-2; BS EN IEC 61000-3-3; IEC 61000-3-3; EN 61000-3-3; KS C 9610-3-3; BS EN 61000-4-2; IEC 61000-4-2; EN 61000-4-2; KS C 9610-4-2
ANSI C63.4:2014; FCC MP-5 (February 1986); ANSI C63.10:2013; ANSI C63.10:2020; ANSI C63.17:2013; FCC KDB 905462 D02 (v02); ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C63.26:2015
ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C63.26:2015
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
7 lines
ISO/IEC 17025
Active6244.01
The scope document we hold says it is valid until 2027-09-30.
Accredited scope, certificate 6244.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | CFR 47, FCC Part 15, Subpart B (using ANSI C63.4:2014); ANSI C63.4-2014; CFR 47, FCC Part 18 (using FCC MP-5:1986); CAN/CSA-CEI/IEC CISPR 11; CSA-CISPR 11; AS CISPR 11; ICES-001; ICES-003; ICES-005; CAN/CSA-CISPR 22; CISPR 13; BS EN 55011; EN 55011; CISPR 11; AS CISPR 11; CISPR 11; KS C 9811; CNS 13803; BS EN IEC 55014-1; EN IEC 55014-1; CISPR 14-1; AS/NZS CISPR 14.1; AS CISPR 14.1; CNS 13783-1; J55014-1; CNS 13783-1; KS C9814-1; J55014; BS EN 55015; BS EN IEC 55015; EN 55015; EN IEC 55015; CISPR 15; AS/NZS CISPR 15; AS CISPR 15; CNS 14115; J55015; KS C9815; J55015; CNS 14115; CISPR 22; VCCI-CISPR 32; BS EN 55032; EN 55032; CISPR 32; AS/NZS CISPR 32; KS C 9832; CNS 13439; CNS 13438; BS EN 61000-3-2; BS EN IEC 61000-3-2; IEC 61000-3-2; EN 61000-3-2; EN IEC 61000-3-2; JIS C 61000-3-2; KS C 9610-3-2; BS EN IEC 61000-3-3; IEC 61000-3-3; EN 61000-3-3; KS C 9610-3-3; BS EN 61000-4-2; IEC 61000-4-2; EN 61000-4-2; KS C 9610-4-2 | - | to 40 GHz |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6244.01) 09/26/2025 Page 2 of 6
Test Technology: Test Method(s) 1:
Immunity (continued)
EFT BS EN 61000-4-4; IEC 61000-4-4; EN 61000-4-4;
KS C 9610-4-4
Surge BS EN 61000-4-5; IEC 61000-4-5; EN 61000-4-5;
KS C 9610-4-5
Conducted Immunity BS EN 61000-4-6; IEC 61000-4-6; EN 61000-4-6;
KS C 9610-4-6
Magnetic Fields BS EN 61000-4-8; IEC 61000-4-8; EN 61000-4-8;
KS C 9610-4-8
Voltage Dips,
Short Interruptions,
and Voltage Variations (VDI)
BS EN 61000-4-11; BS EN IEC 61000-4-11;
IEC 61000-4-11; EN 61000-4-11; EN IEC 61000-4-11;
KS C 9610-4-11
Radiated Immunity
(80 MHz to 6 GHz, 10V/m)
IEC 61000-4-3; EN 61000-4-3; BS EN IEC 61000-4-3;
KS C 9610-4-3
Radiated fields in Close Proximity IEC 61000-4-39;
EN 61000-4-39
Generic and Product Specific EMC BS EN 60601-1-2; IEC 60601-1-2; EN 60601-1-2;
BS EN 50561-1; BS EN 50561-3; EN 50561-1; EN 50561-3;
BS EN 55014-2; EN 55014-2; CISPR 14-2; CNS 13783-2;
J55014-2; AS/NZS CISPR 14-2; KS C 9814-2;
BS EN 61547; IEC 61547; EN 61547; KS C 9547;
BS EN 55035; EN 55035; CISPR 35; KS C 9835;
BS EN 61000-6-1 2; IEC 61000-6-1 2; EN 61000-6-1 2;
CNS 14674-1; BS EN 61000-6-2 2; IEC 61000-6-2 2;
EN 61000-6-2 2; CNS 14674-2; BS EN 61000-6-3 2;
IEC 61000-6-3 2; EN 61000-6-3 2; AS/NZS 61000.6.3;
CNS 14674-3; BS EN 61000-6-4 2; IEC 61000-6-4 2;
EN 61000-6-4 2; AS/NZS 61000.6.4; CNS 14674-4;
EN 60947-5-2; EN 61000-6-8; EN 61326-1 2; EN 61326-2-1;
EN 61326-2-2; EN 61326-2-3; EN 12016; ISO 22200;
IEC 62026-2; IEC 62026-3;
EN 301 489-1; EN 301 489-3; EN 301 489-9;
EN 301 489-17; EN 301 489-19; EN 301 489-22;
EN 301 489-27; EN 301 489-33; EN 301 489-34;
EN 301 489-50; EN 301 489-52 | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6244.01) 09/26/2025 Page 3 of 6
Test Technology: Test Method(s) 1:
Radio Communications
Intentional and Unintentional
Radiators
47 CFR Part 15C (using ANSI C63.10:2013 and
ANSI C63.10:2020);
47 CFR Part 15D (using ANSI C63.17:2013);
47 CFR Part 15E (using ANSI C63.10:2013,
ANSI C63.10:2020, and FCC KDB 905462 D02 (v02));
47 CFR Part 15F (using ANSI C63.10:2013 and
ANSI C63.10:2020);
47 CFR Part 15G (using ANSI C63.10:2013 and
ANSI C63.10:2020);
47 CFR Part 15H (using ANSI C63.10:2013 and
ANSI C63.10:2020);
47 CFR Parts 20 (using ANSI C63.26:2015);
47 CFR Parts 22, 24, 25, 27, 30, 73, 74, 80, 87, 90, 95, 96, 97,
and 101 (using ANSI/TIA-603-E, TIA-102.CAAA-E, or
ANSI C63.26:2015);
RSS-GEN; RSS-111; RSS-112; RSS-119; RSS-123;
RSS-125; RSS-127; RSS-130; RSS-131; RSS-132; RSS-133;
RSS-134; RSS-135; RSS-137; RSS-139; RSS-140; RSS-141;
RSS-142; RSS-170; RSS-181; RSS-182; RSS-192; RSS-194;
RSS-195; RSS-196; RSS-197; RSS-199; RSS-213; RSS-215;
RSS-222; RSS-236; RSS-238; RSS-243; RSS-244; RSS-246;
RSS-247; RSS-248; RSS-251; RSS-252; RSS-287; RSS-310
RSS-210 (up to 40 GHz);
RSS-216 (up to 40 GHz);
RSS-220 (up to 40 GHz);
AS/NZS 4771; AS/NZS 4268; AS/NZS 4295;
Radio Communications
ANSI C63.4; ANSI C63.10; ANSI C63.26;
ANSI C63.10-2020+COR. 1-2023+C63.10A-2024;
ANSI/TIA 603-E; TIA-102.CAAA-E;
EN 300 086; EN 300 113; EN 300 219; EN 300 390;
EN 300 328; EN 301 893; EN 300 220-1; EN 300 220-2;
EN 300 220-3-1; EN 300 220-3-2; EN 300220-4;
EN 300 440-1; EN 300 440-2; EN 300 440; EN 300 113;
EN 300 330-1; EN 300 330-2; EN 300 330; EN 302 291;
EN 302 291-2; EN 302 208; EN 300 422-1; EN 300 422-2;
EN 300 422-3; EN 300 422-4; EN 303 413; EN 303 417;
EN 301 357; EN 303 345-1; EN 303 345-2; EN 303 345-3;
EN 303 345-4; EN 303 345-5; EN 303 609; EN 303 372-2;
EN 302 502; EN 300 609-4; EN 301 511; EN 301 908-1;
EN 301 908-2; EN 301 908-10; EN 301 908-11;
EN 301 908-12; EN 301 908-13; EN 301 908-14;
EN 301 908-15; EN 301 908-18; EN 300 086; EN 300 296; | ||
| 4 | HKCA 1007; HKCA 1008; HKCA 1035; HKCA 1039; HKCA 1042; HKCA 1053; HKCA 1061; HKCA 1033; HKCA 1048; HKCA 1054; HKCA 1057; HKCA 1073; HKCA 1020; HKCA 1043; HKCA 1056; HKCA 1065; HKCA 1072; HKCA 1076; HKCA 1074; HKCA 1075; HKCA 1078; HKCA 1080; HKCA 1081; AS/ACIF S042.3; AS/CA S042.4; AS/NZS 4768; AS/NZS 4365; AS/CA S042.1; ARIB T-33; ARIB T-66; ARIB T-71; IMDA TS AR; IMDA RS SCS; IMDA TS CMT; IMDA TS CT-CTS; IDMA TS DSCRC; IMDA TS IOT; IMDA TS UWB; IMDA TS WSD; IMDA TS DVBT2; IMDA TS LMR; IMDA TS SRD; IMDA TS WBA; Article 2, Paragraph 1 of the Ordinance: Item (1)-12; Item (1)-12-2; Item (6)-2; Item (6)-3; Item (7); Item (8); Item (10); Item (10)-2; Item (19); Item (19)-2; Item (19)-2-2; Item (19)-2-3; Item (19)-3; Item (19)-5; Item (19)-7; Item (19)-9; Item (11)-3; Item (11)-7; Item (11)-19; Item (11)-21; Item (11)-30; Item (11)-34; Item (21); Item (21)-2; Item (21)-3; Item (47); Item (47)-2; Item (47)-4; Item (54); Item (54)-6; Item (67); Taiwan Radio LP0001; LP0002; PLMN01; PLMN05; PLMN07; PLMN08; PLMN10; PLMN12; RTTE01 | - | - |
| 5 | ANSI C63.4:2014; FCC MP-5 (February 1986); ANSI C63.10:2013; ANSI C63.10:2020; ANSI C63.17:2013; FCC KDB 905462 D02 (v02); ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C63.26:2015 | - | to 40000 MHz |
| 6 | ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C63.26:2015 | - | to 40000 MHz |
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
INTERNATIONAL CERTIFICATION SERVICES LLC
Glencoe, MN
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 29th day of September 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 6244.01
Valid to September 30, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Element Materials Technology Minneapolis - Brooklyn ParkBrooklyn Park, MN · ~73 kmA2LAShares 2 accredited test methodsANSI C63.4:2014ANSI/TIA-603-E
- TUV SUD AmericaNew Brighton, MN · ~81 kmA2LAShares 2 accredited test methodsANSI C63.4-2014ANSI C63.4:2014
- Elite Electronic EngineeringDowners Grove, IL · ~597 kmA2LAShares 2 accredited test methodsANSI C63.4:2014ANSI/TIA-603-E
- Element Materials Technology Dallas – Plano WestPlano, TX · ~1,325 kmA2LAShares 2 accredited test methodsANSI C63.4:2014ANSI/TIA-603-E
- TUV SUD AmericaAlpharetta, GA · ~1,457 kmA2LAShares 2 accredited test methodsANSI C63.4-2014ANSI C63.4:2014
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.