Registers refreshed 2026-11-20.See refresh dates
United States

Packaging Compliance

10 Cook St, Suite 3, 01821, Billerica, MA, United States

Visit website
A2LA 3774.02ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
32
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 32 standard numbers and the 6 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM19
ASTM D999
ASTM D4169
ASTM D4279
ASTM D4332
ASTM D4728
ASTM D5276
ASTM D5487
ASTM D6653
ASTM D7386
ASTM E171
ASTM F88
ASTM F1440
Show all 19
ASTM F1886
ASTM F1929
ASTM F1980
ASTM F2096
ASTM F2203
ASTM F2825
ASTM F3039
IEC 60068 series9
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-13
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-29
IEC 60068-2-38Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test
IEC 60068-2-39
IEC 60068-2-40
IEC 60068-2-55
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance

Certificate says EN 60068-2-64. Probably the same standard; not checked against the EN document.

IEC3
IEC 60601-1-11Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment
IEC 60601-2-24
IEC 60721-3-4
Other standards1
ISO 16750-3Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 3: Mechanical loads

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

3 lines
A2LA

ISO/IEC 17025

Active

3774.02

The scope document we hold says it is valid until 2027-08-31.

View scope

Accredited scope, certificate 3774.02

LineMethodMatrixRange
1MIL STD 167-1; MIL STD 202; MIL STD 810; MIL STD 883; ASTM F1980; ASTM D4332; ASTM E171; ASTM D4279; ASTM F2825; RTCA/DO-160; IEC 60068-2-14; IEC 60068-2-38; IEC 600068-2-78; IEC 60601-1-11; ISTA 7D; ASTM D999; IEC 60068-2-55; IEC 60068-2-6; IEC 60068-2-29; IEC 60068-2-64; IEC 60601-2-24; IEC 60721-3-4; ISO 16750-3; ANSI C136.31; ASTM D7386; ASTM D4169; ASTM D5276; ASTM D5487; ASTM D4728; ISTA 1A; ISTA 1B; ISTA 1C; ISTA 1D; ISTA 1G; ISTA 1H; ISTA 2A; ISTA 2B; ISTA 2C; ISTA 3A; ISTA 3B; ISTA 3E; ISTA 3FMedical devicesSee scope document
2MIL STD 810; ASTM D6653; RTCA/DO-160; IEC 60068-2-13; IEC 60068-2-39; IEC 60068-2-40; IEC 60601-1-11; ASTM F1440; ASTM F88; ASTM F1886; ASTM F1929; ASTM F3039; ASTM F2096; ASTM F2203--
3

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation. Accredited Laboratory A2LA has accredited PACKAGING COMPLIANCE LABS, LLC Billerica, MA for technical competence in the field of Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 21st day of November 2025. __ _____________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 3774.02 Valid to August 31, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

10 Cook St, Suite 3, Billerica, MA, 01821, US

42.55843, -71.26895

Open in Maps

Other Locations

1 other site in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.