SIMCO Electronics - Minneapolis
6537 Cecilia Circle, 55439, Bloomington, MN, United States
Visit website- Scope lines
- 15
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 15 scope lines.
A2LA certificate 1395.14 · 15 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.14) 07/29/2025 Page 2 of 14
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Adjustable Thread Ring
Gages –
Functional Diameter
Up to 4 in for
(8 to 80) TPI
W Class Set Plug
Tolerance
Master setting plug
Micrometers3 –
Linearity
Flatness
Parallelism
Up to 36 in
Up to 1 in
Up to 0.001 in
100 µin + 4.2L
7.4 µin
7.4 µin
Gage blocks
Optical flat
Optical parallel
Calipers3
Up to 40 in
180 µin + 4.2L
Gage blocks
Dial, Test, & Digital
Indicators3
Up to 2 in
Up to 6 in
15 µin + 2.4L
110 µin + 2.4L
Gage blocks
Electronic Gage
Amplifiers
(-0.01 to + 0.01) in
4.5 µin + 2.2L
Gage blocks | to 40 in |
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.14) 07/29/2025 Page 3 of 14
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 6, 7 (±)
Comments
DC Voltage3 – Generate
(0 to 220) mV
(0.22 to 2.2) V
(2.2 to 11) V
(11 to 22) V
(22 to 220) V
(220 to 1100) V
8.3 µV/V + 0.4 µV
5.3 µV/V + 0.7 µV
3.9 µV/V + 2.5 µV
3.8 µV/V + 4 µV
5.2 µV/V + 40 µV
6.7 µV/V + 400 µV
Fluke 5720A series II
DC Voltage3 – Measure
(0 to 100) mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 1000) V*
5.5 µV/V + 0.32 µV
4.3 µV/V + 0.32 µV
4.3 µV/V + 0.51 µV
6.2 µV/V + 32 µV
6.2 µV/V + 0.10 mV
HP 3458A opt-2
*add 12(Vin/1000)2 106
to all Vin >100 V
DC Current3 – Generate
(0 to 220) µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
(1.1 to 11) A
(11 to 20) A
43 µA/A + 6.0 nA
55 µA/A + 7.0 nA
54 µA/A + 40 nA
62 µA/A + 0.7 μA
110 µA/A + 12 µA
0.05 % + 500 µA
0.1 % + 750 µA
Fluke 5720A series II
Fluke 5520A/SC1100
DC Current3 – Measure
(0 to 1) µA
(1 to 10) µA
(10 to 100) µA
100 µA to 1 mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
21 µA/A + 70 pA
21 µA/A + 300 pA
21 µA/A + 810 pA
21 µA/A + 5.1 nA
22 µA/A + 51 nA
36 µA/A + 510 nA
0.011 % + 10 µA
HP 3458A opt-2
Resistance3 – Measure
(0 to 10) Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
(0.1 to 1) GΩ
15 µΩ/Ω + 50 µΩ
12 µΩ/Ω + 0.5 mΩ
10 µΩ/Ω + 0.5 mΩ
10 µΩ/Ω + 5 mΩ
10 µΩ/Ω + 50 mΩ
16 µΩ/Ω + 2 Ω
82 µΩ/Ω + 100 Ω
0.051 % + 1 kΩ
0.5 % + 10 kΩ
HP 3458A opt-2
Within ± 1 °C of last
ACAL &
± 5 °C of TCAL | to 1100 V |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.14) 07/29/2025 Page 4 of 14
Parameter/Equipment
Range
CMC2, 5, 6, 7 (±)
Comments
Resistance3 – Generate
Fixed Points
0 Ω
(1, 1.9) Ω
(10, 19) Ω
(100, 190) Ω
1 kΩ
(1.9, 19) kΩ
(100, 190) kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
40 µΩ
95 µΩ/Ω
23 µΩ/Ω
31 µΩ/Ω
9 µΩ/Ω
9.7 µΩ/Ω
13 µΩ/Ω
21 µΩ/Ω
24 µΩ/Ω
44 µΩ/Ω
67 µΩ/Ω
240 µΩ/Ω
Fluke 5720 series II
Resistance3 – Generate
(0 to 11) Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
(0.33 to 1.1) kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
(0.33 to 1.1) MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
(0.33 to 1.1) GΩ
(1 to 10) GΩ
(10 to 100) GΩ
100 GΩ to 1 TΩ
83 µΩ/Ω + 1 mΩ
59 µΩ/Ω + 1.5 mΩ
34 µΩ/Ω + 1.4 mΩ
31 µΩ/Ω + 2.0 mΩ
33 µΩ/Ω + 2.0 mΩ
31 µΩ/Ω + 20 mΩ
31 µΩ/Ω + 20 mΩ
31 µΩ/Ω + 200 mΩ
31 µΩ/Ω + 200 mΩ
41 µΩ/Ω + 2.0 Ω
39 µΩ/Ω + 2.0 Ω
83 µΩ/Ω + 30 Ω
0.015 % + 50 Ω
0.027 % + 2.5 kΩ
0.061 % + 3.0 kΩ
0.30 % + 0.1 MΩ
1.5 % + 0.5 MΩ
0.30 mΩ/Ω + 0.6R
3.6 mΩ/Ω + 0.6R
3.8 mΩ/Ω + 0.6R
Fluke 5520A/SC1100
CMCs shown are
based on 4-wire
compensation only;
for 2-wire & 2-wire
compensation add
5 µV per ampere
stimulus current
(R
floor = E/I)
IET HRRS-B-6-1M-
5kV decade resistor
Capacitance3 – Generate
(0.19 to 0.3999) nF
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.9999) nF
(11 to 32.9999) nF
(33 to 109.999) nF
(110 to 329.999) nF
(0.33 to 1.099 99) µF
(1.1 to 3.299 99) µF
(3.3 to 10.9999) µF
(11 to 32.9999) µF
(33 to 109.999) µF
0.66 % + 10 pF
0.63 % + 10 pF
0.64 % + 10 pF
0.28 % + 10 pF
0.27 % + 0.1 nF
0.23 % + 0.1 nF
0.29 % + 0.3 nF
0.25 % + 1.0 nF
0.21 % + 3.0 nF
0.22 % + 10 nF
0.34 % + 30 nF
0.37 % + 0.1 µF
Fluke 5520A | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.14) 07/29/2025 Page 5 of 14
Parameter/Equipment
Range
CMC2, 6, 7 (±)
Comments
Capacitance3 – Generate
(cont)
(110 to 329.999) µF
(0.33 to 1.099 99) mF
0.37 % + 0.3 µF
0.38 % + 1.0 µF
Fluke 5520A
Electrical Simulation of
Thermocouples3 –
Type E
Type J
Type K
Type T
Type S
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
(0 to 250) °C
(250 to 1000) °C
(1000 to 1400) °C
(1400 to 1767) °C
0.58 °C
0.19 °C
0.17 °C
0.19 °C
0.25 °C
0.32 °C
0.32 °C
0.18 °C
0.21 °C
0.28 °C
0.39 °C
0.22 °C
0.19 °C
0.31 °C
0.47 °C
0.73 °C
0.29 °C
0.21 °C
0.19 °C
0.55 °C
0.42 °C
0.44 °C
0.54 °C
Fluke 5520A
Electrical Calibration of
RTDs
3 –
Pt 385, 100 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
0.080 °C
0.080 °C
0.096 °C
0.11 °C
Fluke 5520A | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.14) 07/29/2025 Page 6 of 14
Parameter/Equipment
Range
CMC2, 5, 6, 7 (±)
Comments
Electrical Calibration of
RTDs3 – (cont)
Pt 385, 100 Ω
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
0.12 °C
0.14 °C
0.25 °C
Fluke 5520A
DC Current Generate –
Clamp Meters
(10 to 25) A
(25 to 150) A
(150 to 1025) A
0.62 % + 0.02 A
0.62 % + 0.14 A
0.62 % + 0.5 A
Fluke 5520A,
Fluke 5500A coil
Oscilloscope3 –
DC Signal
50 Ω
1 MΩ
Square Wave
50 Ω
1 MΩ
Leveled Sine Wave
5 mV to 5 V
5 mV to 2 V
Time Markers
50 Ω
Edge Transition
10 Hz to 2 MHz rate
10 Hz to 2 MHz rate
10 Hz to 1 MHz rate
Pulse Width
1 mV to 200 V
1 mV to 50 V
1 mV
pk-pk to 200 Vpk-pk
40 µVpk-pk to 1 mVpk-pk
50 kHz to 10 MHz
0.1 Hz to 300 MHz
(>300 to 550) MHz
(>0.55 to 3) GHz
(>3 to 6.4) GHz
9.0091 ns to <83 µs
>83 µs to 55 s
500 ps
150 ps
70 ps
(1 to 100) ns
0.06 % + 25 μV
0.06 % + 25 µV
0.37 % + 10 µV
0.28 % + 10 µV
1.3 %
1.9 %
2.2 %
2.4 %
2.8 %
0.42 µs/s
2.4 µs/s
33 ps
14 ps
8.0 ps
4.1 % + 200 ps
Fluke 9500B w/ 9530
& 9560 active head | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.14) 07/29/2025 Page 7 of 14
Parameter/Range
Frequency
CMC2, 6, 7 (±)
Comments
AC Voltage3 – Measure
(1 to 10) mV
(10 to 100) mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
0.036 % + 3.6 µV
0.028 % + 2.3 µV
0.036 % + 2.3 µV
0.11 % + 2.3 µV
0.50 % + 2.3 µV
4.0 % + 2.8 μV
89 µV/V + 4.0 µV
89 µV/V + 2.0 µV
0.015 % + 2.0 µV
0.035 % + 2.0 µV
0.082 % + 2.0 µV
0.30 % + 10 µV
1.0 % + 10 µV
77 µV/V + 40 µV
77 µV/V + 20 µV
0.014 % + 20 µV
0.03 % + 20 µV
0.8 mV/V + 20 µV
3.0 mV/V + 100 µV
10 mV/V + 100 µV
78 µV/V + 400 µV
78 µV/V + 200 µV
0.14 mV/V + 200 µV
0.3 mV/V + 200 µV
0.8 mV/V + 200 µV
3.0 mV/V + 1.0 mV
10 mV/V + 1.0 mV
0.2 mV/V + 4.0 mV
0.2 mV/V + 2.0 mV
0.2 mV/V + 2.0 mV
0.36 mV/V + 2.0 mV
1.2 mV/V + 2.0 mV
4.0 mV/V + 10 mV
15 mV/V + 10 mV
HP 3458A opt-2 | ||
| 8 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.14) 07/29/2025 Page 8 of 14
Parameter/Range
Frequency
CMC2, 6, 7 (±)
Comments
AC Voltage3 – Measure
(cont)
(100 to 700) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
0.4 mV/V + 40 mV
0.4 mV/V + 20 mV
0.6 mV/V + 20 mV
1.2 mV/V + 20 mV
3.0 mV/V + 20 mV
HP 3458A opt-2
AC Voltage3 – Generate
(0 to 2.2) mV
(>2.2 to 22) mV
(>22 to 220) mV
(10 to 20) Hz
(>20 to 40) Hz
(>0.040 to 20) kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
(>300 to 500) kHz
(>0.5 to 1) MHz
(10 to 20) Hz
(>20 to 40) Hz
(>0.040 to 20) kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
(>300 to 500) kHz
(>0.5 to 1) MHz
(10 to 20) Hz
(>20 to 40) Hz
(>0.040 to 20) kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
(>300 to 500) kHz
(>0.5 to 1) MHz
0.22 % + 4.0 µV
0.18 % + 4.0 µV
0.18 % + 4.0 µV
0.29 % + 4.0 µV
0.39 % + 5.0 µV
0.69 % + 10 µV
1.0 % + 20 µV
1.2 % + 20 µV
0.048 % + 4 µV
0.030 % + 4 µV
0.030 % + 4 µV
0.054 % + 4 µV
0.088 % + 5 µV
0.19 % + 10 µV
0.24 % + 20 µV
0.43 % + 20 µV
0.029 % + 12 µV
0.018 % + 7 µV
0.011 % + 7 µV
0.025 % + 7 µV
0.056 % + 17 µV
0.10 % + 20 µV
0.16 % + 25 µV
0.32 % + 45 µV
Fluke 5720 series II | 100 to 700 V |
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.14) 07/29/2025 Page 9 of 14
Parameter/Range
Frequency
CMC2, 6, 7 (±)
Comments
AC Voltage3 – Generate
(cont)
(>0.22 to 2.2) V
(>2.2 to 22) V
(>22 to 220) V
(>220 to 1020) V
(220 to 750) V
(750 to 1100) V
(10 to 20) Hz
(>20 to 40) Hz
(>0.040 to 20) kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
(>300 to 500) kHz
(>0.5 to 1) MHz
(10 to 20) Hz
(>20 to 40) Hz
(>0.040 to 20) kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
(>300 to 500) kHz
(>0.5 to 1) MHz
(10 to 20) Hz
(>20 to 40) Hz
(>0.040 to 20) kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
(>300 to 500) kHz
(>0.5 to 1) MHz
(15 to 50) Hz
(>0.05 to 1) kHz
(30 to 50) kHz
(50 to 100) kHz
40 Hz to 1kHz
(1 to 20) kHz
(20 to 30) kHz
0.026 % + 40 µV
0.0099 % + 15 µV
0.0062 % + 8 µV
0.011 % + 10 µV
0.016 % + 30 µV
0.052 % + 80 µV
0.11 % + 200 µV
0.23 % + 300 µV
0.027 % + 400 µV
0.010 % + 150 µV
0.0066 % + 50 µV
0.011 % + 100 µV
0.016 % + 200 µV
0.044 % + 600 µV
0.12 % + 2.0 mV
0.24 % + 3.2 mV
0.027 % + 4.0 mV
0.011 % + 1.5 mV
0.0079 % + 0.6 mV
0.014 % + 1.0 mV
0.022 % + 2.5 mV
0.094 % + 16 mV
0.45 % + 40 mV
0.82 % + 80 mV
0.030 % + 16 mV
0.0080 % + 3.5 mV
0.24 % + 11 mV
0.33 % + 45 mV
0.011 % + 4 mV
0.018 % + 6 mV
0.060 % + 11 mV
Fluke 5720 series II
Fluke 5720 Series II,
5725A | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.14) 07/29/2025 Page 10 of 14
Parameter/Range
Frequency
CMC2, 6, 7 (±)
Comments
AC Current3 – Measure
(5 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(45 to 1000) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(45 to 100) Hz
(0.1 to 5) kHz
(45 to 100) Hz
(0.1 to 5) kHz
(45 to 100) Hz
(0.1 to 5) kHz
0.061 % + 30 nA
0.062 % + 200 nA
0.034 % + 200 nA
0.062 % + 2 µA
0.034 % + 2 µA
0.062 % + 20 µA
0.034 % + 20 µA
0.085 % + 200 µA
0.1 % + 200 µA
HP 3458A opt-2
AC Current3 – Generate
(0 to 220) µA
(>0.22 to 2.2) mA
(>2.2 to 22) mA
(>22 to 220) mA
(10 to 20) Hz
(>20 to 40) Hz
(>0.04 to 1) kHz
(>1 to 5) kHz
(>5 to 10) kHz
(10 to 20) Hz
(>20 to 40) Hz
(>0.04 to 1) kHz
(>1 to 5) kHz
(>5 to 10) kHz
(10 to 20) Hz
(>20 to 40) Hz
(>0.04 to 1) kHz
(>1 to 5) kHz
(>5 to 10) kHz
(10 to 20) Hz
(>20 to 40) Hz
(>0.04 to 1) kHz
(>1 to 5) kHz
(>5 to 10) kHz
0.025 % + 16 nA
0.016 % + 10 nA
0.013 % + 8.0 nA
0.028 % + 12 µA
0.11 % + 65 µA
0.025 % + 40 nA
0.017 % + 35 nA
0.013 % + 35 nA
0.020 % + 110 nA
0.11 + 650 nA
0.027 % + 400 nA
0.018 % + 350 nA
0.014 % + 350 nA
0.021 % + 550 nA
0.11 % + 5.0 µA
0.027 % + 4.0 µA
0.018 % + 3.5 µA
0.014 % + 2.5 µA
0.021 % + 3.5 µA
0.11 % + 10 µA
Fluke 5720A series II | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.14) 07/29/2025 Page 11 of 14
Parameter/Range
Frequency
CMC2, 5, 6, 7 (±)
Comments
AC Current3 – Generate
(cont)
(>0.22 to 2.2) A
(>2.2 to 11) A
(11 to 20) A
(0.02 to 1) kHz
(>1 to 5) kHz
(>5 to 10) kHz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
45 Hz to 1 kHz
(>1 to 5) kHz
0.027 % + 35 µA
0.046 % + 80 µA
0.7 % + 160 µA
0.047 % + 0.17 mA
0.095 % + 0.38 mA
0.36 % + 0.75 mA
0.15 % + 5.0 mA
3.0 % + 5.0 mA
Fluke 5720A series II
Fluke 5720A Series II,
5725A
Fluke 5520A/SC1100
AC Current Generate –
Clamp Meters –
(10 to 25) A
(25 to 150) A
(150 to 1025) A
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
0.71 % + 0.03 A
1.3 % + 0.03 A
0.73 % + 0.25 A
1.7 % + 0.25 A
0.72 % + 0.9 A
1.6 % + 0.9 A
Fluke 5520A,
Fluke 5500A coil
AC Power – Generate
PF = 1
(0.01 to 0.1) W
(0.1 to 890) W
(0.89 to 3) kW
(3 to 11) kW
(11 to 20.4) kW
45 Hz to 1 kHz
45 Hz to 1 kHz
45 Hz to 1 kHz
45 Hz to 1 kHz
45 Hz to 1 kHz
0.22 %
0.18 %
0.19 %
0.26 %
0.27 %
Fluke 5520A | ||
| 12 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.14) 07/29/2025 Page 12 of 14
III. Mechanical
Parameter/Equipment
Range
CMC2, 5, 9 (±)
Comments
Pressure Measuring
Equipment – Gauges,
Indicators & Transducers3
Pneumatic
Hydraulic
(2 to 50) in WC
(2 to 5) psi
(5 to 30) psi
(30 to 100) psi
(10 to 10 000) psi
0.14 % full scale
0.08 % full scale
0.03 % full scale
0.03 % full scale
0.027 %
Pressure calibrator &
modules, DMM
Dead weight tester
Atmospheric Pressure
(Vacuum) Measuring
Equipment3 – Indicators
& Transducers
(0 to 26.5) in·Hg
0.06 % full scale
Pressure calibrator &
modules, DMM
Force – Measuring
Equipment, Tension &
Compression
(0 to 1000) gf
(0 to 2) lbf
(2 to 20) lbf
(20 to 110) lbf
2.3 mgf
0.04 lbf
0.05 lbf
0.05 lbf
Dead weight method
Torque Wrenches –
Measuring Equipment
(10 to 100) lbf·in
100 lbf·in to 50 lbf·ft
(50 to 1000) lbf·ft
0.21 %
0.18 %
0.19 %
AKO Torque
calibrator w/ torque
transducers
Torque Watches &
Screwdrivers – Measuring
Equipment
(0.5 to 215) ozf∙in
(2.5 to 25) lbf∙in
(10 to 100) ozf∙in
0.39 %
0.21 %
0.21 %
Waters 6500 TS
calibrator w/ weights
& wheels
Torque transducers | 0 to 1000 lbf·ft |
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.14) 07/29/2025 Page 13 of 14
IV. Thermodynamics4
Parameter/Equipment
Range
CMC2, 9 (±)
Comments
Temperature – Measuring
Equipment
(-20 to 140) °C
(140 to 350) °C
0.084 °C
0.14 °C
Precision oil bath, dry
block calibrator or
environmental chamber,
electronic ice point
comparison w/ PRT
Temperature – Measure3
(-196 to 420) °C
0.068 °C
Hart 1502A w/ Hart
5615 PRT
Relative Humidity –
Measure3
(10 to 50) % RH
(50 to 90) % RH
(90 to 95) % RH
1.2 % RH
1.4 % RH
2.4 % RH
Vaisala HMI 41 w/
HMP 46 probe
Relative Humidity –
Measuring Equipment
(10 to 50) % RH
(50 to 90) % RH
1.2 % RH
1.4 % RH
General Eastern M1
dew point meter
V. Time & Frequency
Parameter/Equipment
Range
CMC2, 5, 9 (±)
Comments
Frequency – Measuring
Equipment3
10 MHz Reference
DC to 80 MHz
10 MHz to 26.5 GHz
0.01 nHz/Hz
0.01 nHz/Hz + 0.6R
0.01 nHz/Hz + 0.6R
HP 58503A GPS
reference monitor
Agilent 33250A
HP 8340B
Frequency – Measure3
0.1 Hz to 225 MHz
100 MHz to 26.5 GHz
0.01 nHz/Hz + 0.6R
0.01 nHz/Hz + 0.6R
Agilent 53131A
HP 5351B
Stopwatches & Timers
(0 to 19.99) s/day
0.037 s/day
Helmut Klein 4500
Timometer
Tachometer – Optical
(60 to 200 000) RPM
0.0017 % + 0.6R
HP 3325B
____________________________________________ | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.14) 07/29/2025 Page 14 of 14
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 Type of devices calibrated under the Thermodynamic parameters: Liquid in Glass Thermometers, Bi -
metallic Thermometers, Thermometry Systems, Thermocouple Probes and Wires, Temperature
Indicators, Temperature Transmitters, Relative Humidity Indicators, Rela tive Humidity Transmitters,
Ovens, Chambers, Temperature Controllers, Temperature Measuring Equipment, Thermometry System
Calibrators and Temperature Meter and Probe Combinations.
5 In the statement of CMC, R is the numerical value of the resolution of the device and L is the length in
inches. In the statement of CMC, the value is defined as the percentage of reading.
6 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
7 Floor noise is additive to all readings.
8 This scope meets A2LA’s P112 Flexible Scope Policy.
9 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 15 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- United StandardsBloomington, MN · under 1 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- J&W InstrumentsNew Brighton, MN · ~27 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- PRECISION REPAIR AND CALIBRATIONSBlaine, MN · ~37 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Technical Maintenance, Inc. - ROCKFORDRockford, IL · ~451 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Quality Calibration ServiceNew Berlin, WI · ~466 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.