SIMCO Electronics - Silicon Valley
3131 Jay Street, 95054, Santa Clara, CA, United States
Visit website- Scope lines
- 18
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 18 scope lines.
A2LA certificate 1395.17 · 18 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.17) 08/12/2025 Page 2 of 17
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Linear Indicator –
Digital & Analog
Up to 10 in:
50 µin resolution
100 µin resolution
0.001 in resolution
(20 + 5.3L) µin
(35 + 5.3L) µin
(130 + 5.3L) µin
Gage blocks
Linear Length –
Micrometer Standards,
Attribute Length
Standards
Up to 12 in
(10 + 1.6L) µin
Pratt & Whitney
LabMaster™, gage
block set
Ring Gages
Up to 1 in
(>1 to 4) in
(>4 to 14) in
(5.4 + 0.78L) µin
(4.6 + 0.93L) µin
(8.1 + 0.93L) µin.
Pratt & Whitney
LabMaster™, gage
block set
Cylindrical Gages –
Pins, Plugs, Discs
(0.01 to 12) in
(5.7 + 2.5L) µin
Pratt & Whitney
LabMaster™, gage
block set
Threaded Plug Gages –
Pitch (60˚ Threads)
Major Diameter
(5 to 80) TPI
Up to 12 in
(67 + 4.2L) µin
(36 + 4.2L) µin
Gage blocks with
thread wire & Pratt &
Whitney
LabMaster™
Adjustable Thread Ring
Gages
Up to 5 in
Setting Plug Tolerance
Grade W
Master setting plug
Bore Gages, Inside
Micrometers, Intramikes
3
(0.081 to 6.0) in
(58 + 18L) µin
Gage blocks & ring
gages
Linear Length – Non-
Contact Measure
Up to 12 in
(>12 to 24) in
(>24 to 40) in
(0.0016 + 3.8L) µin
(0.0024 + 3.8L) µin
(0.0032 + 3.8L) µin
Denmark designs
linear encoder | to 10 in |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.17) 08/12/2025 Page 3 of 17
III. Electrical – DC/Low Frequency
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
AC Current – Clamp-on
Meter3
Toroidal
(20 to 150) A
(150 to 1000) A
Non-Toroidal
(20 to 150) A
(150 to 1000) A
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
0.38 % + 0.029 A
0.93 % + 0.032 A
0.38 % + 0.1 A
0.93 % + 0.12 A
0.68 % + 0.29 A
1.2 % + 0.29 A
0.67 % + 1 A
1.2 % + 1 A
Fluke 55XX Fluke
5500A/coil
AC Current – Generate3
(0.2 to 2) mA
(2 to 20) mA
(20 to 200) mA
(0.2 to 2) A
(2 to 11) A
(11 to 20) A
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
20 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
100 Hz to1 kHz
(1 to 5) kHz
0.028 % + 0.6 μA
0.016 % + 0.035 μA
0.013 % + 0.035 μA
0.021 % + 0.11 μA
0.11 % + 0.65 μA
0.026 % + 0.4 μA
0.017 % + 0.35 μA
0.013 % + 0.35 μA
0.021 % + 0.55 μA
0.11 % + 5 μA
0.026 % + 4 μA
0.017 % + 3.5 μA
0.013 % + 2.6 μA
0.022 % + 3.5 μA
0.11 % + 10 μA
0.027 % + 0.035 mA
0.047 % + 0.08 mA
0.71 % + 0.16 mA
0.047 % + 0.17 mA
0.096 % + 0.38 mA
0.36 % + 0.75 mA
0.12 % + 5 mA
0.15 % + 5 mA
3 % + 5 mA
Fluke 5720A
Fluke 5725A
Fluke 55XX | ||
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.17) 08/12/2025 Page 4 of 17
Parameter/Equipment
Range
CMC2, 4, 7 (±)
Comments
AC High Voltage –
Measure3
(1 to 70) kV
0.64 % + 0.6R
HP 34401A,
Hallmark PVD100
Parameter/Range
Frequency
CMC2, 4, 7 (±)
Comments
AC Current – Measure3
(10 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(1 to 3) A
(3 to 30) A
(30 to 300) A
45 Hz to 1 kHz
(45 to 100) Hz
100 Hz to 5 kHz
(45 to 100) Hz
100 Hz to 5 kHz
(45 to 100) Hz
100 Hz to 5 kHz
(45 to 100) Hz
100 Hz to 5 kHz
45 Hz to 2 kHz
(2 to 10) kHz
(45 to 400) Hz
(45 to 400) Hz
0.072 % + 0.035 μA
0.070 % + 0.23 μA
0.037 % + 0.23 μA
0.070 % + 2.3 μA
0.037 % + 2.3 μA
0.070 % + 23 μA
0.037 % + 23 μA
0.093 % + 0.23 mA
0.12 % + 0.23 mA
0.58 % + 0.0023 A
1.2 % + 0.011 A
0.58 % + 0.21 A
0.58 % + 0.43 A
Agilent 3458A
GW Instek
PCS-1000 | 1 to 70 kV |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.17) 08/12/2025 Page 5 of 17
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
AC Voltage – Generate3
Up to 2.2 mV
(>2.2 to 22) mV
(>22 to 220) mV
(>0.22 to 2.2) V
Up to 20 Hz
(>20 to 40) Hz
>40 Hz to 20 kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
(>300 to 500) kHz
(>0.5 to 1) MHz
Up to 20 Hz
(>20 to 40) Hz
>40 Hz to 20 kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
(>300 to 500) kHz
(>0.5 to 1) MHz
Up to 20 Hz
(>20 to 40) Hz
>40 Hz to 20 kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
(>300 to 500) kHz
(>0.5 to 1) MHz
Up to 20 Hz
(>20 to 40) Hz
>40 Hz to 20 kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
(>300 to 500) kHz
(>0.5 to 1) MHz
0.079 % + 4 µV
0.076 % + 4 µV
0.08 % + 4 µV
0.13 % + 4 µV
0.13 % + 5 µV
0.21 % + 10 µV
0.28 % + 20 µV
0.5 % + 20 µV
0.025 % + 4 µV
0.012 % + 4 µV
0.013 % + 4 µV
0.024 % + 4 µV
0.054 % + 5 µV
0.11 % + 10 µV
0.15 % + 20 µV
0.3 % + 20 µV
0.025 % + 12 µV
0.0097 % + 7 µV
0.0088 % + 7 µV
0.021 % + 7 µV
0.047 % + 17 µV
0.091 % + 20 µV
0.14 % + 25 µV
0.28 % + 45 µV
0.024 % + 40 µV
0.0095 % + 15 µV
0.0054 % + 8 µV
0.0081 % + 10 µV
0.0011 % + 30 µV
0.043 % + 80 µV
0.1 % + 0.2 mV
0.17 % + 0.3 mV
Fluke 5720A | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.17) 08/12/2025 Page 6 of 17
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
AC Voltage – Generate3
(cont)
(>2.2 to 22) V
(>22 to 220) V
(>220 to 1100) V
Up to 20 Hz
(>20 to 40) Hz
>40 Hz to 20 kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
(>300 to 500) kHz
(>0.5 to 1) MHz
Up to 20 Hz
(>20 to 40) Hz
>40 Hz to 20 kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
(>300 to 500) kHz
(>0.5 to 1) MHz
Up to 50 Hz
>50 Hz to 1 kHz
0.024 % + 0.4 mV
0.0095 % + 0.4 mV
0.0054 % + 0.051 mV
0.0081 % + 0.1 mV
0.01 % + 0.2 mV
0.029 % + 0.6 mV
0.1 % + 2 mV
0.16 % + 3.2 mV
0.025 % + 4 mV
0.0094 % + 1.5 mV
0.0056 % + 0.061 mV
0.0089 % + 1 mV
0.016 % + 2.5 mV
0.09 % + 16 mV
0.44 % + 40 mV
0.8 % + 80 mV
0.03 % + 16 mV
0.0074 % + 3.6 mV
Fluke 5720A
AC Voltage – Measure3
(1 to 10) mV
(10 to 100) mV
(0.1 to 1) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.1 to 1) MHz
0.039 % + 3.5 μV
0.029 % + 1.3 μV
0.039 % + 1.3 μV
0.012 % + 1.3 μV
0.6 % + 1.3 μV
4.6 % + 2.3 μV
91 μV/V + 4.6 μV
91 μV/V + 2.3 μV
0.017 % + 2.3 μV
0.037 % + 2.3 μV
0.093 % + 2.3 μV
0.35 % + 12 μV
1.2 % + 12 μV
83 μV/V + 46 μV
83 μV/V + 23 μV
0.016 % + 23 μV
0.035 % + 23 μV
0.092 % + 23 μV
0.35 % + 0.12 mV
1.2 % + 0.12 mV
Agilent 3458A | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.17) 08/12/2025 Page 7 of 17
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
AC Voltage – Measure3
(cont)
(1 to 10) V
(10 to 100) V
(100 to 1000) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.2 to 1) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
86 μV/V + 0.47 mV
89 μV/V + 0.23 mV
0.017 % + 0.23 mV
0.035 % + 0.23 mV
0.093 % + 0.23 mV
0.35 % + 1.2 mV
1.2 % + 1.2 mV
0.023 % + 4.6 mV
0.023 % + 2.3 mV
0.023 % + 2.3 mV
0.04 % + 2.3 mV
0.14 % + 2.3 mV
0.046 % + 47 mV
0.046 % + 24 mV
0.069 % + 23 mV
0.14 % + 23 mV
0.35 % + 23 mV
Agilent 3458A
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
Capacitance – Generate3
(0.19 to 0.3999) nF
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.9999) nF
(11 to 32.9999) nF
(33 to 109.9999) nF
(110 to 329.999) nF
(0.33 to 1.099 99) µF
(1.1 to 3.299 99) µF
(3.3 to 10.9999) µF
(11 to 32.9999) µF
(33 to 109.999) µF
(110 to 329.999) µF
(0.33 to 1.099 99) mF
(1.1 to 3.2999) mF
(3.3 to 10.9999) mF
(11 to 32.9999) mF
(33 to 110) mF
1.5 % + 0.01 nF
0.74 % + 0.01 nF
0.82 % + 0.01 nF
0.32 % + 0.01 nF
0.6 % + 0.1 nF
0.32 % + 0.1 nF
0.3 % + 0.1 nF
0.34 % + 1.0 nF
0.49 % + 3.0 nF
0.32 % + 3.0 nF
0.51 % + 10 nF
0.55 % + 100 nF
0.67 % + 300 nF
0.54 % + 1 µF
0.56 % + 3 µF
0.54 % + 10 µF
0.9 % + 30 µF
1.3 % + 100 µF
Fluke 55XX | ||
| 8 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.17) 08/12/2025 Page 8 of 17
Parameter/Equipment
Range
CMC2, 4, 5, 7 (±)
Comments
DC Current – Clamp on
Meters3
(20 to 150) A
(150 to 1000) A
0.61 % + 0.16 A
0.61 % + 0.58 A
Fluke 55XXA
Fluke 5500A/coil
DC Current – Generate3
Up to 220 µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
(2.2 to 11) A
(11 to 20) A
(>20 to 100) A
40 µA/A + 6 nA
42 µA/A + 8.1 nA
42 µA/A + 47 nA
53 µA/A + 0.8 µA
93 µA/A + 14 µA
0.036 % + 480 µA
0.27 % + 1 mA
0.017 % + 1.1 mA
Fluke 5720A
Fluke 5725A
Fluke 55XX
Keysight N8732A w/
shunt & meter
DC Current – Measure3
Up to 1 nA
(>1 to 10) nA
(>10 to 100) nA
(>0.1 to 1) μA
(>1 to 10) μA
(>10 to 100) μA
(>0.1 to 1) mA
(>1 to 10) mA
(>10 to 100) mA
(>0.1 to 1) A
(>1 to 10) A
(>10 to 300) A
240 µA/A + 0.036 pA
180 µA/A + 0.036 pA
89 µA/A + 0.047 pA
5.9 µA/A + 0.3 pA
5.7 µA/A + 0.3 pA
5.3 µA/A + 30 pA
6.6 µA/A + 0.3 nA
6.2 µA/A + 30 nA
5.5 µA/A + 0.3 µA
6.4 µA/A + 3 µA
20 µA/A + 30 µA
46 µA/A + 0.3 mA
Agilent 3458A,
precision resistors
DC High Voltage –
Measure3
(1 to 100) kV
0.07 % + 0.6R
HP 34401A Hallmark
PVD 100 | 20 to 100 A |
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.17) 08/12/2025 Page 9 of 17
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
DC Resistance – Generate3
(0 to 11) Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
(0.33 to 1.1) kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
(0.33 to 1.1) MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
(0.11 to 1.1) GΩ
0.02 % + 10 mΩ
0.011 % + 15 mΩ
56 µΩ/Ω + 15 mΩ
43 µΩ/Ω + 20 mΩ
36 µΩ/Ω + 20 mΩ
43 µΩ/Ω + 200 mΩ
34 µΩ/Ω + 100 mΩ
38 µΩ/Ω + 1 Ω
35 µΩ/Ω + 1 Ω
63 µΩ/Ω + 10 Ω
29 µΩ/Ω + 25 Ω
39 µΩ/Ω + 320 Ω
0.013 % + 520 Ω
0.023 % + 5.2 kΩ
0.057 % + 6.2 kΩ
0.33 % + 200 kΩ
1.7 % + 1.0 MΩ
Fluke 55XX
DC Resistance – Measure3
(0 to 10) Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
(0.1 to 1) GΩ
20 µΩ/Ω + 50 µΩ
17 µΩ/Ω + 0.5 mΩ
13 µΩ/Ω + 0.5 mΩ
13 µΩ/Ω + 5 mΩ
13 µΩ/Ω + 50 mΩ
20 µΩ/Ω + 2 Ω
68 µΩ/Ω + 100 Ω
0.59 mΩ/Ω + 1 kΩ
5.9 mΩ/Ω + 10 kΩ
Agilent 3458A
DC Voltage – Generate3
(0 to 220) mV
(0.22 to 2.2) V
(2.2 to 11) V
(11 to 22) V
(22 to 220) V
(220 to 1100) V
9 µV/V + 1.3 µV
5.2 µV/V + 1.4 µV
3.7 µV/V + 2.8 µV
3.7 µV/V + 4.2 µV
5.2 µV/V + 40 µV
6.7 µV/V + 0.41 mV
Fluke 5720A
DC Voltage – Measure3
(0 to 100) mV
(0 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 1100) V
7.2 µV/V + 0.45 µV
5.4 µV/V + 0.46 µV
5.4 µV/V + 0.94 µV
7.7 µV/V + 45 µV
7.9 µV/V + 0.23 µV
Agilent 3458A | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.17) 08/12/2025 Page 10 of 17
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Electrical Simulation of
Thermocouple Indicators
& Indicating Systems3 –
Type E
Type J
Type K
Type T
(-270 to -200) °C
(>-200 to 0) °C
(>0 to 600) °C
(>600 to 1000) °C
(-210 to -100) °C
(>-100 to 900) °C
(>900 to 1200) °C
(-270 to -200) °C
(>-200 to -100) °C
(>-100 to 600) °C
(>600 to 1000) °C
(>1000 to 1372) °C
(-270 to -200) °C
(>-200 to 0) °C
(>0 to 400) °C
0.091 °C
0.05 °C
0.041 °C
0.045 °C
0.056 °C
0.049 °C
0.053 °C
0.08 °C
0.052 °C
0.052 °C
0.057 °C
0.066 °C
0.14 °C
0.069 °C
0.051 °C
Fluke 55XX Vdc
output mode w/
external thermocouple
reference probe | ||
| 11 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.17) 08/12/2025 Page 11 of 17
Parameter/Range
Frequency
CMC2, 4, 5, 7 (±)
Comments
Oscilloscopes3 –
Level Sine Amp :
50 kHz Ref.
Level Sine Flatness:
5 mV to 5.5 V
Relative to 50 kHz
4 mV to 3.5 V
DC Signal:
50 Ω
1 MΩ
Square Wave:
1 MΩ, 10 Hz to 10 kHz
50 Ω, 1 Hz to 10 kHz
Time Marker:
Output Into 50 Ω
Rise Time – Generate
5 mV to 5.0 V(p-p)
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
(600 to 1100) MHz
(0 to 6.6) V
(0 to 130) V
1 mV to 130 V
(p-p)
1 mV to 6.6 V(p-p)
1 ns to 20 ms
1 kHz to 2 MHz,
(200 to 300) ps
(2 to 10) MHz,
(200 to 350) ps
3.4 % + 0.3 mV
3.2 % + 100 μV
3.4 % + 100 μV
4.3 % + 100 μV
4.3 % + 100 μV
0.20 % + 40 μV
0.27 % + 40 μV
0.21 % + 40 µV
0.35 % + 40 µV
5 µs/s
40 ps
59 ps
Fluke
55XX /SC1100 | to 1100 MHz |
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.17) 08/12/2025 Page 12 of 17
IV. Electrical – RF/Microwave
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
RF Power – Generate3
(7 to 0) dBm
(<0 to -129) dBm
(10 to 25) dBm
(10 to -10) dBm
(<-10 to -60) dBm
(<-60 to -110) dBm
(10 to 25) dBm
(10 to -10) dBm
(<-10 to -60) dBm
(<-60 to -110) dBm
(10 to -10) dBm
(<-10 to -60) dBm
(<-60 to -110) dBm
(10 to -10) dBm
(<-10 to -60) dBm
(<-60 to -110) dBm
250 kHz to 2 GHz
10 MHz to 2 GHz
(2 to 20) GHz
(>20 to 40) GHz
(>40 to 50) GHz
0.7 dB
0.6 dB
1.4 dB
0.72 dB
1.1 dB
1.6 dB
1.5 dB
0.83 dB
1.2 dB
1.8 dB
1.1 dB
1.4 dB
2 dB
2 dB
2.3 dB
3 dB
Agilent/HP E4432B
Agilent/HP 83650B
RF Power – Measure3
(-20 to +30) dBm
(-20 to +30) dBm
(-70 to 20) dBm
10 MHz to 18 GHz
(>18 to 26.5) GHz
(>26.5 to 40) GHz
(>40 to 50) GHz
0.63 dB
0.38 dB
0.38 dB
0.63 dB
Power meter/w
Agilent E4412A
Agilent E4413A
Agilent 8487A/D
Distortion – Measure3
(-80 to 0) dB
(-65 to 0) dB
20 Hz to 20 kHz
(20 to 100) kHz
1.7 dB
2.3 dB
HP 8903B | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.17) 08/12/2025 Page 13 of 17
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
RF Attenuation –
Measure3
(0 to -10) dB
(-10 to -20) dB
(-20 to -30) dB
(-30 to -40) dB
(-40 to -50) dB
(-50 to -60) dB
(-60 to -70) dB
(-70 to -80) dB
(-80 to -90) dB
(-90 to -100) dB
(-100 to -110) dB
(0 to -10) dB
(-10 to -20) dB
(-20 to -30) dB
(-30 to -40) dB
(-40 to -50) dB
(-50 to -60) dB
(-60 to -70) dB
(-70 to -80) dB
(-80 to -90) dB
(-90 to -100) dB
(-100 to -110) dB
(0 to -10) dB
(-10 to -20) dB
(-20 to -30) dB
(-30 to -40) dB
(-40 to -50) dB
(-50 to -60) dB
(-60 to -70) dB
(-70 to -80) dB
(-80 to -90) dB
(-90 to -100) dB
(-100 to -110) dB
(0 to -30) dB
(-30 to -70) dB
(0 to -30) dB
(-30 to -70) dB
0.25 MHz to 1.3 GHz
(>1.3 to 18) GHz
(>18 to 26.5) GHz
(>26.5 to 40) GHz
(>40 to 50) GHz
0.17 dB
0.19 dB
0.21 dB
0.24 dB
0.26 dB
0.28 dB
0.31 dB
0.33 dB
0.35 dB
0.37 dB
0.40 dB
0.38 dB
0.38 dB
0.49 dB
0.49 dB
0.60 dB
0.50 dB
0.55 dB
0.59 dB
0.66 dB
0.65 dB
0.70 dB
0.10 dB
0.10 dB
0.11 dB
0.12 dB
0.14 dB
0.16 dB
0.18 dB
0.21 dB
0.23 dB
0.32 dB
0.34 dB
0.42 dB
0.72 dB
0.74 dB
1.1 dB
Agilent/HP 8902A
measuring receiver
HP 8902A measuring
receiver w/11792A
sensor & 11793A
microwave converter
Agilent 8487A power
sensor w/ power meter
Agilent 8487D power
sensor w/ power meter | ||
| 14 | ASTM | - | to 2000 lbf |
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.17) 08/12/2025 Page 15 of 17
Parameter/Equipment
Range
CMC2, 7, 10 (±)
Comments
Torque Transducer –
Measuring Equipment3
(1 to 160) ozf·in
(10 to 100) lbf·in
(10 to 100) lbf·ft
(100 to 1000) lbf·ft
0.027 %
0.023 %
0.023 %
0.023 %
Calibration arms
& Class F weights
Mass – Measure,
Fixed
1 mg
2 mg
5 mg
10 mg
20 mg
50 mg
100 mg
200 mg
500 mg
1 g
2 g
5 g
10 g
20 g
50 g
100 g
200 g
500 g
1 kg
2 kg
5 kg
10 kg
20 kg
30 kg
9.3 µg
9.4 µg
9.6 µg
5.2 µg
5.4 µg
5.7 µg
6.0 µg
6.0 µg
8.9 µg
9.5 µg
18 µg
18 µg
43 µg
56 µg
88 µg
140 µg
0.32 mg
8.7 mg
11 mg
11 mg
22 mg
35 mg
54 mg
51 mg
Mettler-Toledo
MX5
Sartorius ME-
215S
Sartorius
CC30001
Class 1 mass
weight set using
double
substitution
method
RPM – Measure3
(0 to 50) rpm
(>50 to 500) rpm
(>500 to 5000) rpm
(>5000 to 40 000) rpm
0.016 rpm + 0.58R
0.19 rpm + 0.58R
1.6 rpm + 0.58R
13 rpm + 0.58R
Ametek 1726
tachometer
VI. Thermodynamics
Parameter/Equipment
Range
CMC2, 10 (±)
Comments
Temperature – Measuring
Equipment
(-40 to 140) °C
0.027 °C
Fluke 1551A,
Isotech 798 | ||
| 16 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.17) 08/12/2025 Page 16 of 17
Parameter/Equipment
Range
CMC2, 10 (±)
Comments
Temperature – Measure3
(-40 to 140) °C
0.028 °C
Fluke 1551A
Humidity – Measure3
(11 to 90) % RH
(>90 to 95) %RH
1.6 % RH
2.2 % RH
Vaisala M170/HMP76
Humidity – Measuring
Equipment
(10 to 95) % RH
0.51 % RH
Thunder Scientific
2500
VII. Time & Frequency
Parameter/Equipment
Range
CMC2, 7, 10 (±)
Comments
Frequency – Measuring
Equipment
10 MHz
5 X 10-12 Hz/Hz
Fluke 910 GPS
controlled frequency
standard
Frequency – Measure
DC to 225 MHz
225 MHz to 26.5 GHz
(26.5 to 50) GHz
1.5 X 10-9 Hz/Hz + 0.58R
5 X 10-12 Hz/Hz + 1.3 Hz
5 X 10-12 Hz/Hz + 12 Hz
GPS Receiver w/:
53132A counter
5351B counter
8565E analyzer
Timers/Stopwatches3
Up to 24 hr
56 ms
Fluke 910 GPS
controlled rubidium
frequency standard
___________________________________________________________
1 This laboratory offers commercial and field calibration services.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavio r of the customer’s device and to influences from the
circumstances of the specific calibration. | -40 to 140 °C |
| 17 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.17) 08/12/2025 Page 17 of 17
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
5 Based on using the standard at the temperature the Fluke 5520A with SC600 was calibrated (tcal ± 5 oC)
and assuming the instrument is zeroed at least every seven days or when the ambient temperature changes
more than 5 oC. For resistance, a zero calibration is performed at least every 12 hours within ± 1 oC of
use.
6 Based on using the standard at the temperature the HP 3458A was calibrated (tcal ± 5 oC) and an auto-
calibration (ACAL) was performed within the previous 24 hours (± 1 oC of ambient temperature).
7 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches,
R is the numerical value of the resolution of the device. In the statement of CMC, the value is defined as
the percentage of reading.
8 In the statement of CMC, decade or cardinal values shown. Other values can be obtained using substitution
method with uncertainty increased by a multiple for each substitution.
9 This scope meets A2LA’s P112 Flexible Scope Policy.
10 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 18 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Trescal, Inc. - Silicon Valley, CASan Jose, CA · ~6 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Pacific Calibration ServiceCampbell, CA · ~8 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- HCT AmericaMilpitas, CA · ~10 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- International Process SolutionsSan Carlos, CA · ~32 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Pleasanton, CAPleasanton, CA · ~35 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994