SIMCO Electronics - Washington D.C.
45472 Holiday Dr., Suite #1, 20166, Sterling, VA, United States
Visit website- Scope lines
- 25
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 25 scope lines.
A2LA certificate 1395.08 · 25 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 1 in |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.08) Revised 04/16/2025 Page 2 of 24
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range CMC2, 8 (±) Comments
DC Voltage – Generate3
(0 to 220) mV
(0.22 to 2.2) V
(2.2 to 11) V
(11 to 22) V
(22 to 220) V
(220 to 1100) V
7.7 µV/V + 0.40 µV
5.3 µV/V + 0.70 µV
4.0 µV/V + 2.5 µV
4.0 µV/V + 4.0 µV
5.3 µV/V + 40 µV
6.8 µV/V + 400 µV
Fluke 5700A/EP
DC Voltage – Measure3
Auto, 10 MΩ, 1 MΩ
Auto, 10 MΩ, 1 MΩ
Auto, 10 MΩ, 1 MΩ
Auto, 10 MΩ
1 MΩ
Auto, 10 MΩ
1 MΩ
Up to 200 mV
200 mV to 2 V
(2 to 20) V
(20 to 200) V
(20 to 200) V
200 V to 1.0 kV
200 V to 1.0 kV
7.7 µV/V + 0.40 µV
3.0 µV/V + 0.60 µV
3.0 µV/V + 0.60 µV
4.4 µV/V + 60 µV
9.7 µV/V + 1 mV
4.5 µV/V + 500 µV
9.8 µV/V + 25 mV
Fluke 8588A
DC Current – Generate3
(0 to 220) µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
(2.2 to 11) A
(11 to 20.5) A
39 µA/A + 7.0 nA
32 µA/A + 7.0 nA
32 µA/A + 7.0 nA
39 µA/A + 0.8 µA
70 µA/A + 15 µA
280 µA/A + 480 µA
780 µA/A + 750 µA
Fluke 5700A/EP w/
5725A
Fluke 5520A
DC Current – Measure3
Up to 20 µA
(20 to 200) µA
200 µA to 2 mA
(2 to 20) mA
(20 to 200) mA
200 mA to 2 A
(2 to 20) A
(20 to 30) A
28 µA/A + 7.0 nA
10 µA/A + 7.0 nA
9 µA/A + 70 nA
14 µA/A + 0.7 µA
58 µA/A + 7.0 µA
140 µA/A + 0.1 mA
240 µA/A + 1.6 mA
560 µA/A + 5.4 mA
Fluke 8588A
Resistance – Measure3
Up to 2 Ω
(2 to 20) Ω
(20 to 200) Ω
200 Ω to 2 kΩ
(2 to 20) kΩ
(20 to 200) kΩ
200 kΩ to 2 MΩ
(2 to 20) MΩ
(20 to 200) MΩ
(0.2 to 2) GΩ
(2 to 20) GΩ
17 µΩ/Ω + 0.1 µΩ
10 µΩ/Ω + 0.3 µΩ
9.4 µΩ/Ω + 1 µΩ
9.3 µΩ/Ω + 10 µΩ
9.4 µΩ/Ω + 100 µΩ
9.5 µΩ/Ω + 1.0 mΩ
11 µΩ/Ω + 20 mΩ
19 µΩ/Ω + 20 mΩ
69 µΩ/Ω + 20 mΩ
240 µΩ/Ω + 200 mΩ
1400 µΩ/Ω + 20 MΩ
Fluke 8588A | ||
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.08) Revised 04/16/2025 Page 3 of 24
Parameter/Equipment
Range CMC2, 8 (±) Comments
Resistance – Generate3
0 Ω
1 Ω
1.9 Ω
10 Ω
19 Ω
100 Ω
190 Ω
1 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
46 µΩ
97 µΩ
97 µΩ
24 µΩ
24 µΩ
11 µΩ
11 µΩ
9.7 µΩ
9.7 µΩ
9.7 µΩ
9.7 µΩ
11 µΩ
11 µΩ
20 µΩ
21 µΩ
40 µΩ
47 µΩ
100 µΩ
Fluke 5700A/EP
Oscilloscopes3 –
Level Sine Absolute
50 kHz Reference
Level Sine Flatness
5 mV to 5.5 V relative to
50 kHz Reference
Amplitude Square Wave
1 MΩ, 1 kHz
50 Ω, 1 kHz
Square Wave
1 MΩ, 1 kHz
50 Ω, 1 kHz
Time Marker Output into
50 Ω
Pulse Rise Time
5 mV
p-p to 2.5 Vp-p
5 mV
p-p to 5.5 Vp-p
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
(600 to 1000) MHz
± 1 mV ± 130 Vp-p
± 1 mV ± 6.6 Vp-p
100 mV, 1 V, 10 V
2 ns to 20 ms
50 ms to 5 s
(200 to 300) ps
1 kHz to 2 MHz
(200 to 350) ps
(> 2 to 10) MHz
2.0 % + 300 µV
1.5 % + 100 µV
2.0 % + 100 µV
4.0 % + 100 µV
5.0 % + 100 µV
0.10 % + 40 µV
0.25 % + 40 µV
3.0 % + 100 µV
3.0 % + 100 µV
2.5 x 10
-6 s
(25 + 1000t) µs/s
300 ps
350 ps
Fluke 5520A/SC1100
9500B – Fluke A2LA
t = time in seconds | to 1000 MHz |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.08) Revised 04/16/2025 Page 4 of 24
Parameter/Equipment
Range CMC2 (±) Comments
Electrical Simulation of
Thermocouple – Generate
& Measure
3 –
Type E
Type J
Type K
Type T
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.50 °C
0.16 °C
0.14 °C
0.16 °C
0.21 °C
0.27 °C
0.16 °C
0.14 °C
0.17 °C
0.23 °C
0.33 °C
0.18 °C
0.16 °C
0.26 °C
0.40 °C
0.63 °C
0.24 °C
0.16 °C
0.14 °C
Fluke 5520A/SC1100
Parameter/Range
Frequency
CMC2, 8 (±)
Comments
AC Voltage – Generate3
(2.2 to 22) mV
(22 to 220) mV
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
230 µV/V + 5 µV
89 µV/V + 5 µV
78 µV/V + 5 µV
190 µV/V + 5 µV
470 µV/V + 6 µV
1000 µV/V + 12 µV
1300 µV/V + 25 µV
2600 µV/V + 25 µV
230 µV/V + 15 µV
89 µV/V + 8 µV
78 µV/V + 8 µV
200 µV/V + 8 µV
470 µV/V + 20 µV
1000 µV/V + 25 µV
1300 µV/V + 30 µV
2600 µV/V + 60 µV
Fluke 5700A/EP | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.08) Revised 04/16/2025 Page 5 of 24
Parameter/Range
Frequency
CMC2, 8 (±)
Comments
AC Voltage – Generate3
(cont)
(0.22 to 2.2) V
(2.2 to 22) V
(22 to 220) V
(220 to 1100) V
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(15 to 50) Hz
50 Hz to 1 kHz
(40 to 1) kHz
(1 to 20) kHz
(20 to 30) kHz
(30 to 50) kHz*
(50 to 100) kHz*
230 µV/V + 50 µV
85 µV/V + 20 µV
41 µV/V + 10 µV
70 µV/V + 12 µV
100 µV/V + 40 µV
390 µV/V + 100 µV
930 µV/V + 250 µV
1600 µV/V + 600 µV
230 µV/V + 500 µV
85 µV/V + 200 µV
41 µV/V + 70 µV
70 µV/V + 120 µV
93 µV/V + 250 µV
250 µV/V + 800 µV
930 µV/V + 2500 µV
1400 µV/V + 4000 µV
230 µV/V + 5.0 mV
85 µV/V + 2.0 mV
51 µV/V + 0.7 mV
78 µV/V + 1.2 mV
140 µV/V + 3.0 mV
850 µV/V + 20 mV
4200 µV/V + 50 mV
7800 µV/V + 100 mV
280 µV/V + 20 mV
66 µV/V + 4.0 mV
70 µV/V + 4.0 mV
130 µV/V + 6.0 mV
470 µV/V + 11 mV
470 µV/V + 11 mV
1800 µV/V + 45 mV
Fluke
5700A/EP
* Max voltage
750 V | ||
| 6 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.08) Revised 04/16/2025 Page 6 of 24
Parameter/Range
Frequency
CMC2, 8 (±)
Comments
AC Voltage – Measure3
Up to 12.12 mV,
Auto, 10 MΩ, 1 MΩ
(12 to 121.2) mV,
Auto, 10 MΩ, 1 MΩ
(0.121 to 1.212) V,
Auto, 10 MΩ, 1 MΩ
(1.212 to 12.12) V,
Auto, 10 MΩ, 1 MΩ
(12.12 to 121.2) V,
10 MΩ
(12.12 to 121.2) V,
Auto, 1 MΩ
(121.2 to 1050) V,
10 MΩ
(1 to 2) kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(2 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
(1 to 2) kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(2 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
(1 to 2) kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(2 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
1 Hz to 1 kHz
(1 to 2) kHz
(2 to 10) kHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
1 Hz to 1 kHz
(1 to 2) kHz
(2 to 10) kHz
290 µV/V + 1.7 µV
370 µV/V + 1.7 µV
380 µV/V + 1.7 µV
3000 µV/V + 1.2 µV
10 000 µV/V + 6.1 µV
20 000 µV/V + 6.1 µV
89 µV/V + 790 nV
130 µV/V + 790 µV
230 µV/V + 1.6 µV
530 µV/V + 7.9 µV
2100 µV/V + 48 µV
10 000 µV/V + 160 µV
15 000 µV/V + 790 µV
41 000 µV/V + 1.6 mV
78 000 µV/V + 1.6 mV
160 000 µV/V + 1.6 mV
76 µV/V + 7.9 µV
120 µV/V + 7.9 µV
230 µV/V + 16 µV
530 µV/V + 79 µV
2100 µV/V + 490 µV
10 000 µV/V + 16 mV
15 000 µV/V + 79 mV
40 000 µV/V + 160 mV
78 000 µV/V + 160 mV
150 000 µV/V + 160 mV
76 µV/V + 79 µV
120 µV/V + 79 µV
230 µV/V + 160 µV
530 µV/V + 790 µV
2100 µV/V + 5 mV
10 000 µV/V + 16 mV
15 000 µV/V + 79 mV
40 000 µV/V + 160 mV
78 000 µV/V + 160 mV
150 000 µV/V + 160 mV
250 µV/V + 0.8 µV
1000 µV/V + 0.8 µV
20 000 µV/V + 1.6 µV
90 µV/V + 0.8 µV
110 µV/V + 0.8 µV
230 µV/V + 1.6 µV
590 µV/V + 7.9 µV
3700 µV/V + 73 µV
10 000 µV/V + 790 µV
250 µV/V + 13 µV
3700 µV/V + 630 µV
10 000 µV/V + 7 mV
Fluke 8588A | to 1050 V |
| 7 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.08) Revised 04/16/2025 Page 7 of 24
Parameter/Range5
Frequency CMC2, 8 (±)
Comments
AC Voltage –
Measure3 (cont)
(121.2 to 1050) V
Auto, 1 MΩ
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
110 µV/V + 34 µV
110 µV/V + 34 µV
230 µV/V + 34 µV
590 µV/V + 34 µV
Fluke 8588A
AC Current – Generate
(22 to 220) µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
(2.2 to 11) A
(11 to 20.5) A
(20 to 150) A
(150 to 1025) A
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(0.02 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(0.04 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
1 kHz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
230 µA/A + 20 nA
160 µA/A + 12 nA
110 µA/A + 10 nA
270 µA/A + 15 nA
1000 µA/A + 80 nA
230 µA/A + 50 nA
160 µA/A + 40 nA
110 µA/A + 40 nA
190 µA/A + 130 nA
1000 µA/A + 800 nA
230 µA/A + 500 nA
150 µA/A + 400 nA
110 µA/A + 400 nA
190 µA/A + 700 nA
1000 µA/A + 6000 nA
230 µA/A + 5.0 µA
160 µA/A + 4.0 µA
110 µA/A + 3.0 µA
190 µA/A + 4.0 µA
1000 µA/A + 12 µA
250 µA/A + 40 µA
390 µA/A + 100 µA
6200 µA/A + 200 µA
360 µA/A + 170 µA
740 µA/A + 380 µA
2800 µA/A + 750 µA
0.12 % + 5.0 mA
0.29 % + 22 mA
0.64 % + 24 mA
0.30 % + 81 mA
0.65 % + 90 mA
Fluke 5700A/EP w/
5725A
Fluke 5520A
Fluke 5520A w/
5500/coil | 121.2 to 1050 V |
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.08) Revised 04/16/2025 Page 8 of 24
Parameter/Range5
Frequency
CMC2, 8 (±)
Comments
AC Current –
Measure3
Up to 20.2 µA
(20 to 202) µA
(0.202 to 2.02) mA
(2.02 to 20.20) mA
(20.2 to 202) mA
(0.202 to 2.02) A
(2.02 to 20.2) A
(20.2 to 30.2) A
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
10 Hz to 2 kHz
(2 to 10) kHz
10 Hz to 2 kHz
(2 to 10) kHz
2000 µA/A + 7 nA
2000 µA/A + 7 nA
2000 µA/A + 7 nA
280 µA/A + 13 nA
530 µA/A + 13 nA
740 µA/A + 13 nA
4100 µA/A + 26 nA
280 µA/A + 130 nA
530 µA/A + 130 nA
740 µA/A + 130 nA
4100 µA/A + 260 nA
280 µA/A + 1.3 µA
530 µA/A + 1.3 µA
740 µA/A + 1.3 µA
4100 µA/A + 2.6 µA
280 µA/A + 13 µA
520 µA/A + 13 µA
740 µA/A + 13 µA
300 µA/A + 260 µA
550 µA/A + 260 µA
790 µA/A + 260 µA
840 µA/A + 1.3 mA
840 µA/A + 1.3 mA
650 µA/A + 12 mA
960 µA/A + 12 mA
Fluke 8588A
Phase Angle – Generate3
(0 to 180)°
(10 to 65) Hz
(65 to 500) Hz
500 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
0.11°
0.28°
0.57°
2.9°
5.7°
11°
Fluke
5520A/SC1100 | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.08) Revised 04/16/2025 Page 9 of 24
Parameter/Equipment5
Range CMC2, 4, 8 (±)
Comments
Capacitance – Generate3
(0.19 to 0.3999) nF
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.999) nF
(11 to 32.999) nF
(33 to 109.99) nF
(110 to 329.99) nF
(0.33 to 1.0999) µF
(1.1 to 3.2999) µF
(3.3 to 10.999) µF
(11 to 32.999) µF
(33 to 109.99) µF
(110 to 329.99) µF
330 µF to 1.1 mF
(1.1 to 3.3) mF
(3.3 to 11) mF
(11 to 33) mF
(33 to 110) mF
0.57 % + 0.01 nF
0.57 % + 0.01 nF
0.57 % + 0.01 nF
0.28 % + 0.01 nF
0.28 % + 0.1 nF
0.28 % + 0.1 nF
0.28 % + 0.3 nF
0.28 % + 1 nF
0.28 % + 3 nF
0.28 % + 10 nF
0.46 % + 30 nF
0.51 % + 100 nF
0.51 % + 300 nF
0.51 % + 1 µF
0.51 % + 3 µF
0.51 % + 10 µF
0.85 % + 30 µF
1.3 % + 100 µF
Fluke 55XXA
AC/DC High Voltage –
Measure3
DC High Voltage
AC High Voltage
(60 Hz)
Up to 20 kV
(20 to 35) kV
(35 to 40) kV
Up to 28 kV
2.0 %
2.0 %
2.0 %
5.0 %
Fluke 80k-40i w/
Fluke 87 Series | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.08) Revised 04/16/2025 Page 10 of 24
III. Electrical – RF/Microwave
Parameter/Range
Frequency
CMC2, 4, 8 (±)
Comments
Amplitude Modulation –
Measure
Rate: 50 Hz to 10 kHz
Depth:
(5 to 99) %
Rate: 50 Hz to 100 kHz
Depth:
(5 to 20) %
(20 to 99) %
Rate: 50 Hz to 100 kHz
Depth:
(5 to 20) %
(20 to 99) %
Depth:
(5 to 20) %
(20 to 99) %
Depth:
(5 to 20) %
(20 to 99) %
(0.1 to 10) MHz
(0.01 to 3) GHz
(3 to 26.5) GHz
(26.5 to 31.15) GHz
(31.15 to 50) GHz
0.87 %
2.9 %
0.58 %
5.2 %
1.7 %
7.9 %
2.2 %
30 %
6.9 %
Agilent N5531S
Frequency Modulation – Measure
Rate: 20 Hz to 10 kHz Deviation:
200 Hz to 40 kHz
Rate: 50 Hz to 200 kHz
Deviation: 250 Hz to 400 kHz
(0.25 to 10) MHz
> 0.2 ß
> 1.2 ß
(0.01 to 6.6) GHz
> 0.2 ß
> 0.45 ß
(6.6 to 13.2) GHz
> 0.2 ß
> 8 ß
(13.2 to 31.15) GHz
> 0.2 ß
> 16 ß
(31.15 to 50) GHz
> 0.2 ß
> 32 ß
1.7 %
1.2 %
1.7 %
1.2 %
2.9 %
1.2 %
4.4 %
4.4 %
9.8 %
1.2 %
Agilent N5531S,
ß is the ratio of
frequency deviation
to modulation rate | ||
| 11 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.08) Revised 04/16/2025 Page 11 of 24
Parameter/Range
Frequency
CMC2, 4, 8 (±)
Comments
Phase Modulation –
Measure
> 0.7 rad
> 0.3 rad
> 2 rad
> 0.6 rad
> 4 rad
> 1.2 rad
> 4 rad
> 1.3 rad
> 8 rad
> 2.4 rad
100 kHz to 6.6 GHz
(6.6 to 13.2) GHz
(13.2 to 26.5) GHz
(26.5 to 31.5) GHz
(31.5 to 50) GHz
1.2 % + 0.00082 rad
3.5 % + 0.00082 rad
1.2 % + 0.00082 rad
3.5 % + 0.00082 rad
1.2 % + 0.00082 rad
3.5 % + 0.00082 rad
1.2 % + 0.00082 rad
3.5 % + 0.00082 rad
1.2 % + 0.00082 rad
3.5 % + 0.00082 rad
Agilent N5531S
Distortion – Measure
(-80 to 0) dB
(-65 to 0) dB
20 Hz to 20 kHz
(20 to 100) kHz
1.8 dB
4.5 dB
HP 8903B
Digital Modulation –
Measure
Carrier: 2 MHz to 2.65 GHz
Error Vector Magnitude
Formats Other Than FSK
Error Vector Magnitude
For FSK Modulation
Mod Frequency Span:
1 Hz to 100 kHz
(0.1 to 1) MHz
(1 to 10) MHz
Mod Frequency:
3.2 kHz
1.152 kHz
0.46 % rms
0.78 % rms
1.2 % rms
0.72 % rms
2.1 % rms
HP 89441A vector
signal analyzer | -80 to 0 dB |
| 12 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.08) Revised 04/16/2025 Page 12 of 24
Parameter/Range
Frequency
CMC2, 4, 8 (±)
Comments
RF Absolute Power –
Measure, Standard Coaxial
Thermistor Mount with Type
IV Meter
Power Reference3
1 mW, Type-N(f), 50 Ω
Coaxial Power Sensors3
(+20 to -30) dBm, 50 Ω
(+20 to -30) dBm, 50 Ω
(+20 to -30) dBm, 50 Ω
(+20 to -30) dBm, 50 Ω
(+20 to -70) dBm, 50 Ω
(+20 to -70) dBm, 50 Ω
(+20 to -30) dBm, 50 Ω
50 MHz
100 kHz to 4.2 GHz
10 MHz to 18 GHz
50 MHz to 26.5 GHz
50 MHz to 50 GHz
10 MHz to 18 GHz
50 MHz to 26.5GHz
100 kHz to 2.6 GHz
0.029 dB (0.68 %)
0.12 dB (2.8 %)
0.12 dB (2.8 %)
0.13 dB (3.1 %)
0.13 dB (3.1 %)
0.12 dB (2.8 %)
0.13 dB (3.1 %)
0.12 dB (2.8 %)
HP 432A power meter w/
478A-H76 power sensor
HP 436A or 438A power
meter w/8482A, type-
N(m) power sensor
HP 436A or 438A power
meter w/8481A, type-
N(m) power sensor
HP 436A or 438A power
meters w/ 8485A, 3.5
mm(m) power sensor
HP 436A or 438A power
meter w/ 8487A, 2.4
mm(m) power sensor
HP E4419A power meter
w/ E4412A type-N(m)
power sensor
HP E4419A power meter
w/ E4413A, 3.5 mm(m)
8902A w/ 11722A,
type-N (m) | 20 to -30 dBm |
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.08) Revised 04/16/2025 Page 13 of 24
Parameter/Range
Frequency
CMC2, 8 (±)
Comments
Attenuation,
Relative – Measure3
0 dB, Reference
(-0.0 to -10) dB
(-10 to -20) dB
(-20 to -30) dB
(-30 to -40) dB
(-40 to -50) dB
(-50 to -60) dB
(-60 to -70) dB
(-70 to -80) dB
(-80 to -90) dB
(-90 to -100) dB
(-100 to -110) dB
(-110 to -127) dB
2.5 MHz to 26.5 GHz
0 dB
0.026 dB
0.048 dB
0.07 dB
0.10 dB
0.13 dB
0.15 dB
0.17 dB
0.21 dB
0.23 dB
0.25 dB
0.27 dB
0.29 dB
HP 8902A measuring
receiver
RF Absolute Power –
Generate3
Sine Wave into 50 Ω
(10 to 3) VP-P
2.99 V
P-P to 1 mVP-P
(10 to 3) V
P-P
2.999 V
P-P to 1 mVP-P
(2.999 to 0.1) V
P-P
(99.99 to 1) mVP-P
Sine Wave
Full Amplitude, 50 Ω
13.01 dBm
0.001 Hz to 100 kHz
SWR 1.2:1
0.001 Hz to 100 kHz
SWR 1.2:1
100 kHz to 20 MHz
SWR 1.2:1
100 kHz to 10 MHz
SWR 1.2:1
(10 to 20) MHz
SWR 1.2:1
(10 to 20) MHz
SWR 1.2:1
1 kHz to 25 MHz
200 kHz to 80 MHz
0.1 dB
0.2 dB
0.3 dB
0.5 dB
0.5 dB
0.8 dB
0.12 dB
0.2 dB
Function generator
3325 A/B with BNC(f),
monitored output | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.08) Revised 04/16/2025 Page 14 of 24
Parameter/Range
Frequency
CMC2, 4, 8 (±)
Comments
RF Absolute Power –
Generate3 (cont)
Attenuation, 50 Ω
(0 to 18) dB
(20 to 58) dB
(60 to 98) dB
Sine Wave:
Analog Attenuator
(0 to 1.99) dB
Into 50 Ω
(+13 to -119.9) dBm
(-120 to -130) dBm
Into 50 Ω (Absolute)
(> +20 to +24) dBm
(> +14 to +20) dBm
(-17 to +14) dBm
(-48 to < -17) dBm
(> -74 to < -48) dBm
(> -84 to -74) dBm
(> -94 to -84) dBm
(-130 to -94) dBm
Attenuation 50 Ω
(0 to 33) dB
(33 to 64) dB
(64 to 100) dB
(100 to 116) dB
(+13 to -10) dBm
(+13 to -10) dBm
(+13 to -10) dBm
(+10 to -10) dBm
200 Hz to 80 MHz
200 Hz to 80 MHz
200 Hz to 80 MHz
100 kHz to 80 MHz
SWR 1.5:1
100 kHz to 1280 MHz
SWR 1.5:1
100 kHz to 1280 MHz
SWR 1.5:1
10 Hz to 125 MHz
10 Hz to 1.4 GHz
10 Hz to 4 GHz
10 Hz to 4 GHz
100 kHz to 4 GHz
100 kHz to 4 GHz
100 kHz to 3 GHz
100 kHz to 3 GHz
100 kHz to 100 MHz
100 kHz to 100 MHz
100 kHz to 100 MHz
100 kHz to 100 MHz
10 MHz to 4.2 GHz
10 MHz to 18 GHz
10 MHz to 26.5 GHz
(26.5 to 50) GHz
0.24 dB
0.29 dB
0.4 dB
0.020 dB
1.0 dB
3.0 dB
0.050 dB
0.050 dB
0.050 dB
0.050 dB
0.20 dB
0.50 dB
0.50 dB
1.5 dB
0.035 dB
0.04 dB
0.10 dB
0.20 dB
0.16 dB (3.7 %)
0.16 dB (3.6 %)
0.16 dB (3.8 %)
2.1 dB
Function generator
3325 A/B with BNC(f),
monitored output
Level generator 3335A
with BNC(f),
monitored output
Synthesized signal
generator 8662A
w/ type-N(f), monitored
output
Fluke 9640A RF
reference standard
type-N w/9640A-50
leveling head
Fluke 9640A RF
reference standard,
type-N w/ 9640A-50 Ω
leveling head, relative
to +16 dBm
HP sweeper 83630A,
3.5mm(m) w/ 8482A
power sensor, power
splitter 11667A
HP sweeper 83630A,
3.5mm(m) w/ 8481A
power sensor, power
splitter 11667A
HP sweeper 83630A,
3.5mm(m) w/ 8485A
power sensor, power
splitter 11667B
HP sweeper 83650A,
2.4mm(m) | ||
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.08) Revised 04/16/2025 Page 15 of 24
Parameter/Range
Frequency
CMC2, 8 (±)
Comments
Attenuation –
Generate3
Coaxial, 1 dB Step
0 dB
(0 to 12) dB
Coaxial, 10 dB Step
0 dB
10 dB
20 dB
30 dB
40 dB
50 dB
60 dB
70 dB
80 dB
90 dB
100 dB
Reference
0.10 MHz
0.30 MHz
50 MHz
Reference
0.10 MHz
0.30 MHz
50 MHz
0.10 MHz
0.30 MHz
50 MHz
0.10 MHz
0.30 MHz
50 MHz
0.10 MHz
0.30 MHz
50 MHz
0.10 MHz
0.30 MHz
50 MHz
0.10 MHz
0.30 MHz
50 MHz
0.10 MHz
0.30 MHz
50 MHz
0.10 MHz
0.30 MHz
50 MHz
0.10 MHz
0.30 MHz
50 MHz
0.10 MHz
0.30 MHz
50 MHz
Reference
0.090 dB
Reference
0.11 dB
0.12 dB
0.12 dB
0.13 dB
0.15 dB
0.17 dB
0.20 dB
0.21 dB
0.24 dB
0.24 dB
Agilent attenuator
355C w/ BNC(f)
Agilent attenuator
355D w/ BNC(f) | ||
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.08) Revised 04/16/2025 Page 16 of 24
Parameter/Range
Frequency
CMC2, 8 (±)
Comments
Attenuation – Generate3
(cont)
Coaxial, 10 dB Step
110 dB
120 dB
0.10 MHz
0.30 MHz
50 MHz
0.10 MHz
0.30 MHz
50 MHz
0.25 dB
0.29 dB
Agilent attenuator
355D w/ BNC(f)
Reflection S11/S22 –
Measure
(0.6 to 1) lin
(0.2 to 0.5) lin
(0.0 to 0.1) lin
(0.6 to 1) lin
(0.2 to 0.5) lin
(0.0 to 0.1) lin
(0.6 to 1) lin
(0.2 to 0.5) lin
(0.0 to 0.1) lin
(0.6 to 1) lin
(0.2 to 0.5) lin
(0.0 to 0.1) lin
300 kHz to 6 GHz
300 kHz to 6 GHz
45 MHz to 18 GHz
45 MHz to 20 GHz
(0.012 to + 0.024) lin
(1.2 to + 1.9)°
(0.006 to + 0.014) lin
(1.3 to + 2.5)°
(0.004 to + 0.007) lin
(2.9 to + 180)°
(0.0070 to + 0.014) lin
(0.70 to + 1.0)°
(0.0040 to + 0.0080) lin
(0.90 to + 1.7)°
(0.0020 to + 0.0040) lin
(1.7 to + 180)°
(0.012 to + 0.018) lin
(0.83 to + 0.94)°
(0.0064 to + 0.011) lin
(1.1 to + 1.8)°
(0.0051 to + 0.0056) lin
(3.3 to + 180)°
(0.0093 to + 0.015) lin
(0.63 to + 0.72)°
(0.0048 to + 0.0081) lin
(0.77 to + 1.4)°
(0.0035 to + 0.004) lin
(2.3 to + 180)°
8753ES
85032F/E type-N
cal kit
8753ES
85031B 7mm cal.
kit
8510C, 8515A,
85054B type-N
(sliding load cal)
8510C, 8515A,
85050C 7mm
(TRL cal) | ||
| 17 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.08) Revised 04/16/2025 Page 17 of 24
Parameter/Range5
Frequency
CMC2, 8 (±)
Comments
Reflection S11/S22 –
Measure (cont)
(0.6 to 1) lin
(0.2 to 0.5) lin
(0.0 to 0.1) lin
45 MHz to 26.5 GHz
(0.014 to + 0.023) lin
(1.2 to + 1.2)°
(0.0073 to + 0.012) lin
(1.3 to + 2.1)°
(0.0059 to + 0.0064) lin
(3.8 to + 180)°
8510C, 8515A,
85052B 3.5mm
(sliding load cal)
Transmission S12/S21 –
Measure
10 dB
0 dB
-10 dB
-20 dB
-30 dB
-40 dB
-50 dB
-60 dB
(-70 to -100) dB
10 dB
0 dB
-10 dB
-20 dB
300 kHz to 6 GHz
300 kHz to 6 GHz
(0.24 to + 0.24) dB
(3.7 to + 3.7)°
(0.070 to + 0.085) dB
(0.50 to + 0.59)°
(0.084 to + 0.10) dB
(0.75 to + 0.82)°
(0.090 to + 0.10) dB
(0.80 to + 0.90)°
(0.090 to + 0.11) dB
(0.8 to + 0.90)°
(0.090 to + 0.12) dB
(0.81 to + 0.90)°
(0.098 to + 0.12) dB
(0.85 to + 0.93)°
(0.14 to + 0.15) dB
(1.2 to + 1.4)°
(0.14 to + 10) dB
(1.2 to + 180)°
(0.27 to + 0.27) dB
(3.5 to + 3.5)°
(0.059 to + 0.066) dB
(0.40 to + 0.44)°
(0.072 to + 0.077) dB
(0.66 to + 0.69)°
(0.078 to + 0.082) dB
(0.72 to + 0.77)°
8753ES
85032F/E type-N
cal. kit
8753ES
85031B 7 mm cal.
kit | ||
| 18 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.08) Revised 04/16/2025 Page 18 of 24
Parameter/Range5
Frequency
CMC2, 8 (±)
Comments
Transmission S12/S21 –
Measure (cont)
-30 dB
-40 dB
-50 dB
-60 dB
(-60 to -100) dB
10 dB
0 dB
-10 dB
-20 dB
-30 dB
-40 dB
-50 dB
-60 dB
300 kHz to 6 GHz
45 MHz to 18 GHz
(0.078 to + 0.082) dB
(0.72 to + 0.77)°
(0.079 to + 0.083) dB
(0.73 to + 0.77)°
(0.083 to + 0.090) dB
(0.77 to + 0.81)°
(0.13 to + 0.14) dB
(0.11 to + 0.12)°
(0.13 to + 10) dB
(1.0 to +
180)°
(0.13 to + 0.22) dB
(1.3 to + 4.2)°
(0.051 to + 0.093) dB
(0.21 to + 3.9)°
(0.066 to + 0.093) dB
(0.33 to + 4.0)°
(0.067 to + 0.094) dB
(0.34 to + 4.0)°
(0.07 to + 0.097) dB
(0.37 to + 4.0)°
(0.076 to + 0.12) dB
(0.45 to + 4.2)°
(0.11 to + 0.20) dB
(0.73 to + 4.8)°
(0.24 to + 0.49) dB
(1.7 to + 6.7)°
8753ES
85032B/E type-N
cal kit
8510C, 8515A,
85054B
type-N (sliding load
cal) | -60 to -100 dB |
| 19 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.08) Revised 04/16/2025 Page 19 of 24
Parameter/Range5
Frequency
CMC2, 8 (±)
Comments
Transmission S12/S21 –
Measure (cont)
10 dB
0 dB
-10 dB
-20 dB
-30 dB
-40 dB
-50 dB
-60 dB
10 dB
0 dB
-10 dB
-20 dB
-30 dB
45 MHz to 20 GHz
45 MHz to 26.5 GHz
(0.068 to + 0.22) dB
(1.3 to + 3.8)°
(0.046 to + 0.049) dB
(0.18 to + 3.6)°
(0.050 to + 0.065) dB
(0.30 to + 3.7)°
(0.051 to + 0.067) dB
(0.31 to + 3.7)°
(0.054 to + 0.068) dB
(0.35 to + 3.7)°
(0.064 to + 0.073) dB
(0.43 to + 3.9)°
(0.11 to + 0.15) dB
(0.72 to + 4.5)°
(0.24 to + 0.45) dB
(1.7 to + 6.4)°
(0.13 to + 0.22) dB
(1.3 to + 5.8)°
(0.054 to + 0.11) dB
(0.21 to + 5.7)°
(0.069 to + 0.11) dB
(0.31 to + 5.7)°
(0.070 to + 0.11) dB
(0.34 to + 5.7)°
(0.073 to + 0.13) dB
(0.38 to + 5.9)°
8510C, 8515A,
85050C, 7mm
(TRL Cal)
8510C, 8515A,
85052B 3.5mm
(sliding load cal) | 45 to 26.5 MHz to GHz |
| 20 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.08) Revised 04/16/2025 Page 20 of 24
Parameter/Range5
Frequency
CMC2, 4, 8 (±)
Comments
Transmission S12/S21 –
Measure (cont)
-40 dB
-50 dB
-60 dB
45 MHz to 26.5 GHz
(0.078 to + 0.20) dB
(0.46 to + 6.4)°
(0.11 to + 0.46) dB
(0.75 to + 8.1)°
(0.24 to + 1.4) dB
(1.7 to + 14)°
8510C, 8515A,
85052B 3.5mm
(sliding load cal)
RF Power Sensors – Measure
Coaxial TC / Diode Power
Sensors:
Reference: 1 mW, 50 MHz
0.1 MHz
(0.3 to 1.0) MHz
3.0 MHz to 2.5 GHz
(3.0 to 3.5) GHz
(4.0 to 4.2) GHz
10 MHz
50 MHz
(0.5 to 5.0) GHz
(6.0 to 8.0) GHz
9.0 GHz
10 GHz
(11 to 12) GHz
12.4 GHz
13 GHz
14 GHz
(15 to 16) GHz
17 GHz
18 GHz
0.77 %*
0.71 %
0.68 %
0.71 %
0.73 %
0.77 %
0.71 %
0.67 %
0.71 %
0.73 %
0.80 %
0.74 %
0.71 %
0.74 %
0.76 %
0.81 %
0.90 %
0.98 %
HP 438A, 8482A-
H84
* % indicates
uncertainty of
adjusted reference
HP 438A, 8481A-
H84 | ||
| 21 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.08) Revised 04/16/2025 Page 21 of 24
Parameter/Range
Frequency
CMC2, 4, 8 (±)
Comments
RF Power Sensors – Measure
Coaxial TC / Diode Power
Sensors @ 1 mW;
Reference to 50 MHz
@1 mW
(0.05 to 4.0) GHz
(> 4.0 to 10) GHz
(11 to 12) GHz
(12.4 to 13) GHz
14 GHz
15 GHz
(16 to 17) GHz
18 GHz
19 GHz
20 GHz
21 GHz
22 GHz
(23 to 24) GHz
25 GHz
26 GHz
26.5 GHz
1.2 %
1.3 %
1.8 %
1.4 %
2.5 %
2.1 %
1.5 %
2.1 %
2.8 %
1.6 %
2.0 %
2.1 %
2.0 %
2.4 %
2.1 %
2.4 %
HP 432A power
meter w/ 8485A-H84
Phase Noise – Measure
250 kHz to 20 GHz
Offset:
1 Hz
10 Hz
100 Hz
1 kHz
10 kHz
20 kHz
100 kHz
2.8 dBc/Hz
2.5 dBc/Hz
2.4 dBc/Hz
2.4 dBc/Hz
2.4 dBc/Hz
2.4 dBc/Hz
2.3 dBc/Hz
E8257D Opt. UNX
w/ E5505A system
IV. Mechanical
Parameter/Equipment
Range CMC2, 4, 10 (±) Comments
Pressure3 – Measuring
Equipment
Pneumatic
(0 to 300) psig
(0 to 500) psig
0.030 % (of span)
0.030 % (of span)
Heise PTE-1/HQS-2 | ||
| 22 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.08) Revised 04/16/2025 Page 22 of 24
Parameter/Equipment
Range CMC2, 4, 10 (±) Comments
Scales & Balances3
(1 to 500) mg
> 500 mg to 5 g
(> 5 to 20) g
(> 20 to 453) g
> 453 g to 2 kg
(> 2 to 9) kg
(> 9 to 204) kg
0.003 mg + 0.6R
0.004 mg + 0.6R
0.66 mg + 0.6R
9.9 mg + 0.6R
23 mg + 0.6R
180 mg + 0.6R
(350 mg * N) + 0.6R
Class 1 & 2 weights
Class 6 weights
N = # of 50 lb
weights
R = resolution of
DUT
Torque – Measuring
Equipment3
(0.5 to 2.5) ozf•in
(2 to 10) ozf•in
0.24 % + 0.29 ozf•in
0.24 % + 0.058 ozf•in
Waters 6500-T3
Dial Wrenches, Click
Wrenches, Beam
Wrenches, Screwdrivers
(10 to 100) ozf•in
(20 to 200) ozf•in
(2.5 to 25) lbf•in
(10 to 100) lbf•in
(25 to 250) lbf•in
(100 to 1000) lbf•in
(25 to 250) lbf•ft
(75 to 750) lbf•ft
0.57 % ozf•in
0.39 % ozf•in
0.50 % lbf•in
0.29 % lbf•in
0.58 % lbf•in
0.38 % lbf•in
0.65 % lbf•ft
0.43 % lbf•ft
Reference torque
transducers
V. Thermodynamics
Parameter/Equipment
Range5 CMC2, 10 (±) Comments
Temperature –
Measure
3
(-196 to 0) °C
(0 to 100) °C
(100 to 200) °C
(200 to 420) °C
0.090 °C
0.030 °C
0.031 °C
0.046 °C
PRT 5614 w/ Fluke
1521
Temperature –
Measuring Equipment
(-20 to 50) °C
1.2 °C
Environmental
chamber w/ PRT
5614
Relative Humidity –
Measuring Equipment
(5 to 95) % RH
1.4 % RH
RH systems 973 | ||
| 23 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.08) Revised 04/16/2025 Page 23 of 24
VI. Time & Frequency
Parameter/Equipment
Range
CMC2, 10 (±)
Comments
Frequency – Timebase,
Measure
10 MHz
12 pHz/Hz
NIST FMAS system
w/ respect to UTC,
frequency counter
Frequency – Measure3
Up to 3 GHz
525 MHz to 26.5 GHz
2.4 nHz/Hz
0.23 µHz/Hz
HP 53132A, HP
5351B, NIST FMAS
system w/ respect to
UTC
Frequency –
Measuring Equipment3
1 Hz to 120 MHz
0.068 µHz/Hz
Fluke 96270A, NIST
FMAS system w/
respect to UTC
Timers & Stopwatches
Up to 24 hrs
51 ms
Frequency counter
/GPS controlled
frequency standard
___________________________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, the value is defined as the percentage of reading unless otherwise noted.
5 Where ranges are not specified, the CMC stated is for the cardinal points only.
6 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches.
7 Enrolled in Fluke’s DVMP Program for Proficiency Testing as compared to Fluke Primary Standards
Laboratory equipment. | to 3 GHz |
| 24 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.08) Revised 04/16/2025 Page 24 of 24
8 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent
or fraction of the reading plus a fixed floor specification.
9 This scope meets A2LA’s P112 Flexible Scope Policy.
10 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 25 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Automated PrecisionRockville, MD · ~23 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Electrical Test InstrumentsFrederick, MD · ~46 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- InvoCalRixeyville, VA · ~68 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994