Test Labs Limited
Unit 21/22 Coningsby Road, Bretton, PE3 8SB, Peterborough, United Kingdom
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Test Labs Limited?
Claim this profile to keep it accurate.
Register record
- UKASRefreshed
- 22215Active
Accredited standards
9Our reading of the UKAS scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
EN 1276Name not checked yet
BS EN 1276:2019; BS EN 1650:2019 Bactericidal quantitative suspension test for medical applications MIC-TP-002 based on BS EN 13727:2012; BS EN 13624:2021; BS EN 16615:2015; ISO/IEC 17025:2017 Test Labs Limited Issue No: 011 Issue date: 03 September 2025 Unit 22 Coningsby Road Bretton Peterborough PE3 8
EN 1650Name not checked yet
BS EN 1276:2019; BS EN 1650:2019 Bactericidal quantitative suspension test for medical applications MIC-TP-002 based on BS EN 13727:2012; BS EN 13624:2021; BS EN 16615:2015; ISO/IEC 17025:2017 Test Labs Limited Issue No: 011 Issue date: 03 September 2025 Unit 22 Coningsby Road Bretton Peterborough PE3 8
EN 13624Name not checked yet
BS EN 1276:2019; BS EN 1650:2019 Bactericidal quantitative suspension test for medical applications MIC-TP-002 based on BS EN 13727:2012; BS EN 13624:2021; BS EN 16615:2015; ISO/IEC 17025:2017 Test Labs Limited Issue No: 011 Issue date: 03 September 2025 Unit 22 Coningsby Road Bretton Peterborough PE3 8
EN 13727Name not checked yet
BS EN 1276:2019; BS EN 1650:2019 Bactericidal quantitative suspension test for medical applications MIC-TP-002 based on BS EN 13727:2012; BS EN 13624:2021; BS EN 16615:2015; ISO/IEC 17025:2017 Test Labs Limited Issue No: 011 Issue date: 03 September 2025 Unit 22 Coningsby Road Bretton Peterborough PE3 8
EN 16615Name not checked yet
BS EN 1276:2019; BS EN 1650:2019 Bactericidal quantitative suspension test for medical applications MIC-TP-002 based on BS EN 13727:2012; BS EN 13624:2021; BS EN 16615:2015; ISO/IEC 17025:2017 Test Labs Limited Issue No: 011 Issue date: 03 September 2025 Unit 22 Coningsby Road Bretton Peterborough PE3 8
EN 17272Name not checked yet
BS EN ISO 15883-5:2021; BS EN ISO 15883-2:2009; BS EN ISO 17665-1:2006; BS EN 17272:2020 employing test chamber sizes of 67; BS 8628
ISO 15883-2Washer-disinfectors - Part 2: Requirements and tests for washer-disinfectors employing thermal disinfection for critical and semi-critical medical devices
BS EN ISO 15883-5:2021; BS EN ISO 15883-2:2009; BS EN ISO 17665-1:2006; BS EN 17272:2020 employing test chamber sizes of 67; BS 8628
ISO 15883-5Washer-disinfectors - Part 5: Performance requirements and test method criteria for demonstrating cleaning efficacy
BS EN ISO 15883-5:2021; BS EN ISO 15883-2:2009; BS EN ISO 17665-1:2006; BS EN 17272:2020 employing test chamber sizes of 67; BS 8628
ISO 17665-1Sterilization of health care products - Moist heat - Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices
BS EN ISO 15883-5:2021; BS EN ISO 15883-2:2009; BS EN ISO 17665-1:2006; BS EN 17272:2020 employing test chamber sizes of 67; BS 8628
Scope as published by UKAS
2 lines
ISO/IEC 17025
Active22215
Accredited scope, certificate 22215
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | Biological Testing | BS EN 1276:2019; BS EN 1650:2019 Bactericidal quantitative suspension test for medical applications MIC-TP-002 based on BS EN 13727:2012; BS EN 13624:2021; BS EN 16615:2015; ISO/IEC 17025:2017 Test Labs Limited Issue No: 011 Issue date: 03 September 2025 Unit 22 Coningsby Road Bretton Peterborough PE3 8 | Food products | - |
| 2 | Mechanical Testing | BS EN ISO 15883-5:2021; BS EN ISO 15883-2:2009; BS EN ISO 17665-1:2006; BS EN 17272:2020 employing test chamber sizes of 67; BS 8628 | Soil | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United Kingdom
- RPS Environmental Management Limited trading as RPS MountainheathBedfordshire · ~58 kmUKASShares 2 accredited materialsFood productsSoil
- Chemtech EnvironmentalCounty Durham · ~256 kmUKASShares 2 accredited materialsFood productsSoil
- Agri-Food and Biosciences Institute (AFBI)Northern Ireland · ~496 kmUKASShares 2 accredited materialsFood productsSoil
- Soil Property TestingHuntingdon · ~27 kmUKASShares 1 accredited materialSoil
- LGC LimitedCambridgeshire · ~35 kmUKASShares 1 accredited materialFood products
Accreditation data refreshed from the UKAS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the UKAS entry linked above.