SWS Werkstoffprüfung
Plauener Straße 36 b, 08491, Netzschkau, Germany
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at SWS Werkstoffprüfung?
Claim this profile to keep it accurate.
Register record
- DAKKSRefreshed
- D-PL-19010-01-01Active
- D-PL-19010-01-02Active
- D-PL-19010-01-00Active
Certificates and scope
3ISO/IEC 17025
ActiveD-PL-19010-01-01
Accredited scope, certificate D-PL-19010-01-01
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | ndt | DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001 | - | - |
| 2 | ndt | DIN EN ISO 5579; DIN EN ISO 17636-1; DIN EN 12681-1; DIN EN ISO 17640; DIN EN ISO 16810; DIN EN 10308; DIN EN 10160; DIN EN 10307; DIN EN 10228-3; DIN EN 10228-4 | Metal | 6 to mm |
| 3 | ndt | DIN EN ISO 9934-1; DIN EN ISO 17638; DIN EN 1369; DIN EN 10228-1; DIN EN ISO 3452-1; DIN EN 10228-2; DIN EN 1371-1; DIN EN 1371-2; DIN EN ISO 17637; DIN EN 13018 | Schmiedestücken aus Stahl; Schweißverbindungen; Gießereiwesen; Schweißnähten | - |
| 4 | ndt | DIN EN 1370; AD 2000-Merkblatt HP 5/3; DIN EN ISO 17635 | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
ActiveD-PL-19010-01-02
Accredited scope, certificate D-PL-19010-01-02
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | materials | DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001 | metallische Werkstoffe | - |
| 2 | mechanical | DIN EN ISO 148-1; DIN EN ISO 6892-1; DIN EN ISO 4136; DIN EN ISO 7438; DIN EN ISO 5173; DIN EN ISO 6507-1; DIN EN ISO 9015-1 | Metallische Werkstoffe | - |
| 3 | materials | DIN EN ISO 17639; SOP 14 | Metal | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
ActiveD-PL-19010-01-00
Accredited scope, certificate D-PL-19010-01-00
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | - | DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001 | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Germany
- CEWUS Chemnitzer Werkstoff- und Oberflächentechnik GmbH CEWUS Erstes Chemnitzer Werkstoff- und SchadensanalyselaborChemnitz · ~51 kmDAKKSShares 5 accredited methods and materialsEN ISO 17640EN ISO 9001ISO 3452-1
- TQD Technische Qualitätssicherung DreiländereckZittau · ~185 kmDAKKSShares 4 accredited methods and materialsEN ISO 17640EN ISO 9001ISO 3452-1
- wbm Prüflabor GmbHEberswalde · ~271 kmDAKKSShares 4 accredited methods and materialsEN ISO 17640EN ISO 9001ISO 3452-1
- RSE Röntgen Service EglyMannheim · ~291 kmDAKKSShares 4 accredited methods and materialsEN ISO 17640EN ISO 9001ISO 3452-1
- MG-ZfPSt. Johann · ~318 kmDAKKSShares 4 accredited methods and materialsEN ISO 17640EN ISO 9001ISO 3452-1
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.