Registers refreshed 2026-11-20.See refresh dates
United States

Parametric

4065 E La Palma Ave, Suite C, 92807, Anaheim, CA, United States

Visit website
A2LA 3865.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
4
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 4 scope lines.

A2LA certificate 3865.01 · 4 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3865.01) 05/23/2025 Page 1 of 3 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 PARAMETRIC, INC. 4065 E La Palma Ave, Suite C Anaheim, CA 92807 Drew Harris Phone: 714 694 6500 CALIBRATION Valid To: March 31, 2027 Certificate Number: 3865.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 5: I. Chemical II. Mechanical Parameter Range CMC2, 4 (±) Comments Conductivity – Measuring Equipment, Fixed Points3 1 μS 10 μS 100 μS 1413 μS 10 004 μS 0.33 μS 0.41 μS 1.0 μS 5.8 μS 36 μS Standard conductivity solution pH – Measuring Equipment, Fixed Points 3 4.0 pH 7.0 pH 10.0 pH 0.011 pH 0.012 pH 0.012 pH Standard pH buffer solution Parameter Range CMC2, 4 (±) Comments Non-Contact Tachometer Up to 50 RPM (50 to 500) RPM (500 to 5000) RPM (5000 to 50 000) RPM (50 000 to 200 000) RPM 0.0023 RPM 0.0034 RPM 0.014 RPM 0.13 RPM 1.3 RPM Fluke 5522A calibrator or equivalent
2-Measuring Equipment
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3865.01) 05/23/2025 Page 2 of 3 Parameter Range CMC2, 4 (±) Comments Vacuum – Measuring Equipment3 (-14.7 to 0) psi 0.0065 psi Additel ADT760-MA calibrator with Additel ADT155 pressure module or equivalent Pressure – Measuring Equipment3 (-20 to 20) inH2O 0.000 73 in H2O Fluke 7250LP or equivalent Pressure – Measuring Equipment3 (0 to ≤35) psig (˃35 to 300) psig 0.0061 psi 0.041 psi Additel ADT760-MA calibrator with Additel ADT155 pressure module or equivalent III. Thermodynamics Parameter Range CMC2, 4 (±) Comments Humidity – Measure & Measuring Equipment3 (10 to 20) % RH (20 to 60) % RH (60 to 85) % RH (85 to 95) % RH 1.2 % RH 1.4 % RH 1.5 % RH 2.1 % RH Vaisala MI70 With HMP77B or equivalent Temperature – Measure & Measuring Equipment3 (-200 to 200) °C (200 to 420) °C (420 to 660) °C 0.0072 °C 0.030 °C 0.040 °C Precision thermometer with PRT or equivalent ________________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavi or of the customer’s device and to influences from the circumstances of the specific calibration.
-14.7 to 0 psi
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3865.01) 05/23/2025 Page 3 of 3 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 5 This scope meets A2LA’s P112 Flexible Scope Policy.
4ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

4065 E La Palma Ave, Suite C, Anaheim, CA, 92807, US

33.83475, -117.91173

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.