What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 39 standard numbers and the 29 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 61000 series12
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments+1 national
National versions in the same scope
AS/NZS 61000-6-3national version with changes
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments+1 national
National versions in the same scope
AS/NZS 61000-6-4probably the same standard; matched by number only
ETSI11
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-9
ETSI EN 301 489-17
ETSI EN 301 489-53
ETSI EN 301 511Global System for Mobile communications (GSM); Mobile Stations (MS) equipment; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 301 893
ETSI EN 301 908-1
ETSI EN 301 908-13
ETSI EN 302 502
CISPR7
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS CISPR 11national version with changes
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard
CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS/NZS CISPR 22identical to it
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+1 national
National versions in the same scope
AS/NZS CISPR 32identical to it
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements
IEC5
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61547Equipment for general lighting purposes - EMC immunity requirements
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)
IEC 62479Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
Other standards4
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
EN 50663Generic standard for assessment of low power electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (10 MHz - 300 GHz)
EN 50665
FCC PART 15Radio Frequency Devices
47 CFR, FCC Part 15 B, (using ANSI C63.4:2014); 47 CFR, FCC Part 18 (using MP-5:1986); IEC/CISPR 22; AS/NZS CISPR 22; IEC/CISPR 11; EN 55011; AS CISPR 11; BS EN 55011; IEC/CISPR 14-1; EN 55014-1; BS EN 55014-1; IEC/CISPR 15; EN 55015; BS EN 55015; IEC/EN 55032; AS/NZS CISPR 32; BS EN 55032; ICES-003; ICES-005; EN 61000-3-2; BS EN 61000-3-2; EN 61000-3-3; BS EN 61000-3-3; IEC 61000-4-2; EN 61000-4-2; BS EN 61000-4-2; IEC 61000-4-4; EN 61000-4-4; BS EN 61000-4-4; IEC 61000-4-5; EN 61000-4-5; BS EN 61000-4-5; IEC 61000-4-6; EN 61000-4-6; BS EN 61000-4-6; IEC 61000-4-8; EN 61000-4-8; BS EN 61000-4-8; IEC 61000-4-11; EN 61000-4-11; BS EN 61000-4-11
EN 61547; BS EN 61547; IEC/CISPR 14-2; EN 55014-2; BS EN 55014-2; EN 61000-6-1; BS EN 61000-6-1; EN 61000-6-2; BS EN 61000-6-2; EN 61000-6-3; AS/NZS 61000-6-3; BS EN 61000-6-3; EN 61000-6-4; AS/NZS 61000-6-4; BS EN 61000-6-4; EN 61326; EN 61326-1; BS EN 61326-1; IEC 60601-1-2; CISPR 35; IEC/EN 55035; BS EN 55035; ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-9; ETSI EN 301 489-17; ETSI EN 301 489-53; 47 CFR, FCC Parts 15 C and E; ANSI C63.4:2014; ANSI C63.10:2013; 47 CFR, FCC Parts 22; 24; 25; 27; ANSI/TIA-603-E:2016; ANSI C63.26-2015; RSS-GEN; RSS-132; RSS-133; RSS-134; RSS-139; RSS-195; RSS-197; RSS-199; RSS-210; RSS-216; RSS-247; RSS-310; AN/NZS 4268; ARIB STD-T66; Article 2-1-19; Article 2-1-19-3; Article 2-1-19-3-2; ETSI EN 300 328; ETSI EN 301 893; ETSI EN 302 502; EN 301 511; EN 301 908-1; EN 301 908-13; ANSI C95.1; RSS-102; EN 62311; EN 50665; EN 62479; EN 50663
ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2013; ANSI/TIA-603-E:2016; ANSI C63.26-2015
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
4 lines
ISO/IEC 17025
Active6246.01
The scope document we hold says it was valid until 2026-06-30. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.
Accredited scope, certificate 6246.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | 47 CFR, FCC Part 15 B, (using ANSI C63.4:2014); 47 CFR, FCC Part 18 (using MP-5:1986); IEC/CISPR 22; AS/NZS CISPR 22; IEC/CISPR 11; EN 55011; AS CISPR 11; BS EN 55011; IEC/CISPR 14-1; EN 55014-1; BS EN 55014-1; IEC/CISPR 15; EN 55015; BS EN 55015; IEC/EN 55032; AS/NZS CISPR 32; BS EN 55032; ICES-003; ICES-005; EN 61000-3-2; BS EN 61000-3-2; EN 61000-3-3; BS EN 61000-3-3; IEC 61000-4-2; EN 61000-4-2; BS EN 61000-4-2; IEC 61000-4-4; EN 61000-4-4; BS EN 61000-4-4; IEC 61000-4-5; EN 61000-4-5; BS EN 61000-4-5; IEC 61000-4-6; EN 61000-4-6; BS EN 61000-4-6; IEC 61000-4-8; EN 61000-4-8; BS EN 61000-4-8; IEC 61000-4-11; EN 61000-4-11; BS EN 61000-4-11 | - | - |
| 2 | EN 61547; BS EN 61547; IEC/CISPR 14-2; EN 55014-2; BS EN 55014-2; EN 61000-6-1; BS EN 61000-6-1; EN 61000-6-2; BS EN 61000-6-2; EN 61000-6-3; AS/NZS 61000-6-3; BS EN 61000-6-3; EN 61000-6-4; AS/NZS 61000-6-4; BS EN 61000-6-4; EN 61326; EN 61326-1; BS EN 61326-1; IEC 60601-1-2; CISPR 35; IEC/EN 55035; BS EN 55035; ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-9; ETSI EN 301 489-17; ETSI EN 301 489-53; 47 CFR, FCC Parts 15 C and E; ANSI C63.4:2014; ANSI C63.10:2013; 47 CFR, FCC Parts 22; 24; 25; 27; ANSI/TIA-603-E:2016; ANSI C63.26-2015; RSS-GEN; RSS-132; RSS-133; RSS-134; RSS-139; RSS-195; RSS-197; RSS-199; RSS-210; RSS-216; RSS-247; RSS-310; AN/NZS 4268; ARIB STD-T66; Article 2-1-19; Article 2-1-19-3; Article 2-1-19-3-2; ETSI EN 300 328; ETSI EN 301 893; ETSI EN 302 502; EN 301 511; EN 301 908-1; EN 301 908-13; ANSI C95.1; RSS-102; EN 62311; EN 50665; EN 62479; EN 50663 | - | to 40 GHz |
| 3 | ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2013; ANSI/TIA-603-E:2016; ANSI C63.26-2015 | - | to 40000 MHz |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
SHENZHEN DL TESTING TECHNOLOGY CO., LTD.
Shenzhen, People’s Republic of China
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 25th day of September 2024.
____________________________
Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 6246.01
Valid to June 30, 2026 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Labs with overlapping accredited scope in China
- Audix Technology (Wujiang)DAKKSShares 1 accredited test methodANSI C63.4:2014
- CTC Laboratories, Inc.Shenzhen, GuangdongA2LAShares 1 accredited test methodANSI C63.4:2014
- CTSL Testing (Dongguan) Co.,DongguanA2LAShares 1 accredited test methodANSI C63.4:2014
- CVC Testing Technology Co.,Ltd.DAKKSShares 1 accredited test methodEN 61547
- DEKRA Testing and Certification (Shanghai)ShanghaiA2LAShares 1 accredited test methodANSI C63.4:2014
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.