PCB Piezotronics

3425 Walden Avenue, 14043, Depew, NY, United States

Visit website
A2LA 1862.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
6
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 6 scope lines.

A2LA certificate 1862.01 · 6 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006-See scope document
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1862.01) Revised 02/25/2026 Page 2 of 5 II. Mechanical Parameter/Equipment Range CMC2, 5 (±) Comments Acoustic Pressure – Measuring Equipment 114.0 dB SPL @ 250 Hz 0.2 dB reading (rdg) Acoustic calibrator and pre-amplifiers Dynamic Force (Compression/Tension) – Measure (0 to 100 000) lbf 1 % full scale (FS) Reference load cell Impulse Force – Sensitivity (Voltage/Force) Measure Up to 5000 lbf Up to 1000 Hz 3.8 % rdg Quartz reference accelerometer Static Pressure – Measure (0 to 30) psia (0 to 60) psia (0 to 15) psig (0 to 50) psig (0 to 100) psia or psig (0 to 300) psia or psig (0 to 600) psia or psig (0 to 1000) psia or psig (0 to 3000) psia or psig (0 to 6000) psia or psig (0 to 10 000) psia or psig 0.015 % FS 0.015 % FS 0.015 % FS 0.015 % FS 0.015 % FS 0.015 % FS 0.015 % FS 0.015 % FS 0.021 % FS 0.021 % FS 0.021 % FS DHI pressure controller/calibrator Static Medium Pressure – Measure (0 to 15 000) psig 1 % FS Dead weight reference (hydraulic) Static High Pressure – Measure (0 to 100 000) psig 1.7 % FS Reference pressure transducer Dynamic Low Pressure – Measure (0 to 100) psig 124.0 dB @ 250 Hz 1 % FS 0.45 dB Digital Heise reference pressure meter (pneumatic) Piston phone reference
0 to 100000 psig
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1862.01) Revised 02/25/2026 Page 3 of 5 Parameter/Equipment Range CMC2, 4, 5 (±) Comments Dynamic Medium Pressure – Measure (0 to 1000) psig 1.3 % FS Digital Heise reference pressure meter (pneumatic) Dynamic High Pressure – Measure (0 to 15 000) psig 3.0 % FS Reference pressure sensor (hydraulic) Vibration General Purpose – Sensitivity Magnitude Accelerometers Low Frequency – Sensors (5 to 9) Hz (10 to 99) Hz (100 to 1999) Hz (2000 to 10 000) Hz (10 001 to 15 000) Hz (15 001 to 20 000) Hz (0.5 to 0.99) Hz (1 to 30) Hz (30.01 to 199) Hz (200 to 1000) Hz 2 % rdg 1.5 % rdg 1 % rdg 2.5 % rdg 5 % rdg 9 % rdg 1.8 % rdg 1 % rdg 1.5 % rdg 3 % rdg Reference accelerometer, back-to-back comparison method Reference accelerometer with long stroke shaker, back-to-back comparison method Vibration General Purpose – Acceleration Level Portable Shakers (79.6 to 159.2) Hz 1.5 % rdg Accelerometer, back-to- back comparison method
0 to 1000 psig
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1862.01) Revised 02/25/2026 Page 4 of 5 Parameter/Equipment Range7 CMC2, 5 (±) Comments Vibration General Purpose – Sensitivity Phase Accelerometers Low Frequency – Sensors (≥5 to <10) Hz ≥10 Hz to <5 kHz (≥5 to <11) kHz (≥11 to <16) kHz (≥16 to ≤20) kHz (≥0.5 to <10) Hz (≥10 to <200) Hz ≥200 Hz to ≤1 kHz 1° 0.75° 1.5° 2° 3° 2.5° 0.75° 1.5° Reference accelerometer, back-to-back comparison method Reference accelerometer with long stroke shaker, back-to-back comparison method Primary Vibration – Sensitivity Magnitude – Measure Mid to High Frequency Low Frequency 5 Hz 5 Hz < f <100 Hz 100 Hz< f ≤ 160 Hz 160 Hz < f ≤ 1000 Hz 1000 Hz < f ≤ 5000 Hz 5000 Hz < f ≤ 15 kHz 15 kHz < f ≤ 20 kHz 0.5 Hz ≤ f <10 Hz 1 % rdg 0.5 % rdg 0.2 % rdg 0.5 % rdg 1 % rdg 1.5 % rdg 2.0 % rdg 0.3 % rdg Laser interferometry and shaker Laser interferometry and long stroke shaker Primary Vibration – Sensitivity Phase – Measure Mid to High Frequency Low Frequency 5 Hz ≤ f <5000 Hz 5000 Hz < f ≤ 20 kHz 0.5 Hz ≤ f <10 Hz 0.5° 1° 0.5° Laser interferometry and shaker Laser interferometry and long stroke shaker Acceleration Amplitude Linearity, Shock – Measure (100 to 2000) g: (0.5 to 2) ms (>2000 to 10 000) g: (0.1 to 0.5) ms 1.9 % rdg 2.6 % rdg Reference accelerometer with pneumatic shock tower, back-to-back comparison method
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1862.01) Revised 02/25/2026 Page 5 of 5 SATELLITE FACILITY PCB PIEZOTRONICS INC. 15801 Camino Vecinal Vesta Park Mega Region, Tijuana, MEXICO 22643 Julio Lopez Phone: +52 6646153859 CALIBRATION I. Mechanical Parameter/Equipment Range CMC2 (±) Comments Vibration General Purpose – Sensitivity Magnitude Accelerometers (5 to 9) Hz (10 to 99) Hz (100 to 1999) Hz (2000 to 10 000) Hz (10 001 to 15 000) Hz (15 001 to 20 000) Hz 2 % 1.5 % 1 % 2.5 % 5 % 9 % Reference accelerometer, back- to-back comparison method ___________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 CMCs are expressed as either a specific value that covers the full range or as a fraction of the reading plus a fixed floor specification. 4 CMCs for Vibration parameters are for Sensitivity (accelerometers/sensors) or Acceleration level (shakers). 5 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 6 This scope meets A2LA’s P112 Flexible Scope Policy. 7 In the statement of range, f is frequency.
6ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.