West Caldwell Calibration
1575 State Route 96., 14564, Victor, NY, United States
Visit website- Scope lines
- 8
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 8 scope lines.
A2LA certificate 1533.01 · 8 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | - | Acoustic Measuring Equipment; Pistonphones; Sound Level Meters; Electrical Simulation of Sound Level Meters, Preamplifiers, Measuring Amplifiers, Analyzers & FiltersShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1533.01) 01/19/2026 Page 2 of 7
Parameter/Range
Frequency CMC2, 8 (±) Comments
Acoustic Measuring Equipment
– Sound Pressure Level3
114 dB re 2 x 10-5 Pa
(94 to 114) dB re 2 x 10-5 Pa
1000 Hz
31.5 Hz
(63, 125, 250, 500) Hz
(1, 2, 4, 8) kHz
(12.5, 16) kHz
0.16 dB
0.16 dB
0.15 dB
0.15 dB
0.16 dB
B&K 4226 & 4134
Pistonphones – Sound Pressure
Level3
(114 to 134) dB re 2 x 10-5 Pa
250 Hz
0.13 dB
B&K 4228 &
attenuator
Sound Level Meters – Sound
Pressure Level Measuring
Equipment
3
(94 to 114) dB re 2 x 10-5 Pa
31.5 Hz
(63, 125, 250, 500) Hz
(1, 2, 4, 8, 12.5) kHz
16 kHz
0.16 dB
0.15 dB
0.15 dB
0.16 dB
B&K 4226
Electrical Simulation of
Sound Level Meters,
Preamplifiers, Measuring
Amplifiers, Analyzers &
Filters
3
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 250) kHz
0.02 dB
0.02 dB
0.02 dB
0.03 dB
Function generator,
Agilent 33120A &
3458A
Electrical Simulation of
Sound Level Meters,
Preamplifiers, Measuring
Amplifiers, Analyzers &
Filters
3
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 250) kHz
0.02 dB
0.02 dB
0.02 dB
0.02 dB
Function generator,
Agilent 33120A &
34401A | See scope document |
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1533.01) 01/19/2026 Page 3 of 7
Parameter/Equipment
Frequency CMC2 (±) Comments
Noise Dosimeters3 –
(94, 104 & 114) dB
2 Hz to 20 kHz
0.23 dB
B&K 4226
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range CMC2, 4, 6 (±) Comments
DC Voltage – Generate
Up to 320 mV
(0.32 to 3.2) V
(3.2 to 32) V
(32 to 320) V
(320 to 1050) V
0.045 % + 0.4 μV
0.044 % + 0.4 μV
0.045 % + 0.6 μV
0.046 % + 40 μV
0.076 % + 13 mV
Wavetek 9100
DC Voltage – Measure
Up to 100 mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
0.044 % + 0.4 μV
0.044 % + 0.4 μV
0.044 % + 0.6 μV
0.045 % + 40 μV
0.045 % + 13 mV
Keysight 3458A
DC Voltage – Measure3
1 mV to 1000 V
0.045 % + 5 mV
Agilent 34401A
DC Current – Generate
Up to 320 µA
(0.32 to 3.2) mA
(3.2 to 32) mA
(32 to 320) mA
(0.32 to 3.2) A
0.055 % + 0.1 μA
0.049 % + 0.2 μA
0.047 % + 3.0 μA
0.072 % + 40 μA
0.16 % + 0.6 mA
Wavetek 9100
DC Current – Measure
Up to 100 nA
(0.1 to 10) µA
(10 to 100) µA
(0.1 to 100) mA
(0.1 to 1) A
0.046 % + 10 μA
0.044 % + 100 μA
0.044 % + 1 nA
0.045 % + 10 nA
0.046 % + 100 nA
Keysight 3458A | to 1050 V |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1533.01) 01/19/2026 Page 4 of 7
Parameter/Equipment
Range CMC2, 4, 6 (±) Comments
Resistance – Generate
(40 to 400) Ω
(0.4 to 40) kΩ
(4 to 40) kΩ
(40 to 400) kΩ
(0.4 to 4) MΩ
(4 to 40) MΩ
0.18 % + 20 mΩ
0.11 % + 80 mΩ
0.08 % + 0.8 Ω
0.58 % + 8 Ω
0.14 % + 0.1 Ω
2.4 % + 2.0 kΩ
Wavetek 9100
Resistance – Measure
(1 to 10) Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
0.03 % + 10 µΩ
0.03 % + 10 µΩ
0.03 % + 100 µΩ
0.03 % + 1 mΩ
0.03 % + 10 mΩ
0.03 % + 100 mΩ
0.03 % + 1 Ω
Keysight 3458A
Parameter/Range
Frequency CMC2, 6 (±) Comments
AC Voltage – Generate
Up to 320 mV
(0.32 to 3.2) V
(3.2 to 32) V
(32 to 320) V
(320 to 1050) V
10 Hz to 100 kHz
40 Hz to 1 kHz
0.24 % + 0.4 mV
0.26 % + 0.4 mV
0.43 % + 7 mV
0.42 % + 90 mV
0.18 % + 130 mV
Wavetek 9100
AC Voltage – Measure
Up to 10 V
(10 to 100) V
(100 to 1000) V
20 Hz to 300 kHz
1 kHz
1 kHz
0.012 % + 40 μV
0.024 % + 4 mV
0.081 % + 20 mV
Keysight 3458A
AC Voltage – Measure3
Up to 100 mV
(1 to 750) V
1 kHz to 50 kHz
10 Hz to 50 kHz
0.014 % + 7 μV
0.47 % + 0.7 mV
Agilent 34401A | ||
| 5 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1533.01) 01/19/2026 Page 5 of 7
III. Electrical – RF/Microwave
Parameter/Range
Frequency CMC2, 6 (±) Comments
Attenuation – Generate3
(0 to -60) dB
(0 to -80) dB
1 kHz
10 Hz to 50 kHz
0.06 dB
0.15 dB
WB 0785
Attenuation – Measure3
(0 to -60) dB
(0 to -80) dB
1 kHz
10 Hz to 50 kHz
0.07 dB
0.27 dB
Agilent 34401A
IV. Mechanical
Parameter/Equipment
Range CMC2, 5, 6 (±) Comments
Calibration Exciters –
Acceleration Level3
(m/s2, “g”)
(100 to 160) Hz
10 Hz to 10 kHz
1.3 %
2.5 %
B&K 8305/2635
Random Noise –
Measure3
100 Hz to 20 kHz
(20 to 200) kHz
100 Hz to 10 kHz
20 Hz to 20 kHz
0.30 dB
0.50 dB
0.30 dB
0.50 dB
B&K 1623/2636
B&K 2133
B&K 3560
Dynamic Pressure Sensors
250 Hz
20 Hz to 200 kHz
0.18 dB
1.0 dB
B&K 4228
WB 0736 & UA0033
stepped sine response | 0 to -60 dB |
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1533.01) 01/19/2026 Page 6 of 7
Parameter/Equipment
Range CMC2, 5 (±) Comments
Accelerometers –
Charge Sensitivity
(0.02 to 5000) pC/g
Voltage Sensitivity
(0.02 to 5000) mV/g
Voltage & Charge
Sensitivities
(0.02 to 10 000) mV/g
(0.02 to 10 000) pC/g
100 Hz & 160 Hz
(5 to 10) Hz
(10 to 40) Hz
40 Hz to 2 kHz
(2 to 4) kHz
(4 to 7) kHz
(7 to 10) kHz
100 Hz & 160 Hz
(5 to 10) Hz
(10 to 40) Hz
40 Hz to 2 kHz
(2 to 4) kHz
(4 to 7) kHz
(7 to 10) kHz
(10, 80, 100, & 160) Hz
(0.5 to 10) Hz
(10 to 40) Hz
40 Hz to 2 kHz
(2 to 4) kHz
(4 to 7) kHz
(7 to 20) kHz
1.3 %
1.4 %
1.4 %
1.4 %
1.8 %
2.2 %
2.5 %
1.3 %
2.0 %
1.6 %
1.4 %
1.8 %
2.2 %
2.5 %
1.3 %
2.5 %
2.0 %
1.4 %
1.8 %
2.2 %
2.5 %
B & K 9610,
B&K 4808, 4809
B & K 9610,
B&K 4808, 4809
Sensitivity frequency
response plot using
B&K 3560, 4808,
4809
V. Time & Frequency
Parameter/Equipment
Range CMC2, 6 (±) Comments
Frequency – Measure
1 Hz to 10 MHz
0.06μHz/Hz
HP 3458A
________________________________
1 This laboratory offers commercial calibration services and field calibration services.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration and this laboratory meets A2LA R104 – General | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1533.01) 01/19/2026 Page 7 of 7
Requirements: Accreditation of Field Testing and Field Calibration Laboratories for these calibrations.
Please note the actual measurement uncertainties achievable on a customer's site can normally be
expected to be larger than the CMCs found on the A2LA Scope. Allowance must be made for aspects
such as the environment at the place o f calibration and for other possible adverse effects such as those
caused by transportation of the calibration equipment. The usual allowance for the uncertainty introduced
by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result
in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC.
4 Based on using the standard at the temperature the Agilent 3458A was calibrated (tcal ± 5 oC) and an auto-
calibration (ACAL) was performed within the previous 24 hours (± 1 oC of ambient temperature).
5 In the statement of CMC, percentages are to be read as percent of reading.
6 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent
or fraction of the reading plus a fixed floor specification. | ||
| 8 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Empire Scale Corporation d.b.a Precision Scale & BalanceLancaster, NY · ~99 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Hapeman ElectronicsStoneboro, PA · ~288 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- HJM PrecisionTroy, NY · ~304 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - AllentownAllentown, PA · ~310 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Newark, NJBoonton, NJ · ~339 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.