United States

HJM Precision

9 New Turnpike Road, 12182, Troy, NY, United States

Visit website
A2LA 1579.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
14
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 14 scope lines.

A2LA certificate 1579.01 · 14 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-to 24 in
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1579.01) 10/06/2025 Page 2 of 13 Parameter/Equipment Range CMC2, 4 (±) Comments Levels – Tubular Cylindrical Up to 10ʺ Up to 60ʺ 5ʺ 5ʺ Gage blocks & surface plates Length Standards Up to 20 in (20 to 80) in (5.0 + 3L) µin (10 + 5L) µin Master length standards/ gage blocks/comparator Micrometers3 – Precision Outside Diameter Bore Depth Up to 2 in Up to 24 in (24 to 42) in Up to 4 in (4 to 8) in Up to 12 in 16 µin (85 + 6L) µin (160 + 3L) µin (100 + L) µin (200 + 2L) µin (100 + L) µin UMM & gage blocks Gage block Length standards Master ring gage Master ring gage Gage blocks Micrometers, Inside Diameter Up to 12 in Up to 24 in Up to 36 in Up to 48 in Up to 80 in 150 µin 170 µin 190 µin 200 µin 250 µin UMM, gage blocks/length standards Optical Comparators3 – Linearity/Squareness Up to 20 in (100 + 2L) µin Gage blocks/length standards Pipe Thread Plug – Pitch Diameter: (4 to 80) TPI Major Diameter Length to Notch (0.0625 to 10) in (0.0625 to 10) in (0.0625 to 10) in 110 µin 100 µin 60 µin Three wire method in fixture Comparator Gage blocks
to 10 in
3ASME/ANSI B1.2-1983; ASME/ANSI B1.3-2007-See scope document
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1579.01) 10/06/2025 Page 4 of 13 Parameter/Equipment Range9 CMC2, 4 (±) Comments Thread Ring Gages (cont.) – Solid Gages: Pitch Diameter Minor Diameter (0.25 to 8) in (0.25 to 8) in (100 + 3D) µin (100 + 3D) µin UMM Video Measurement System3 – X, Y Axis Z Axis Up to 48 in Up to 12 in (70 + 5L) µin (70 + 5L) µin Verification grids Gage blocks with length standards Vision Measurement System3 – – X, Y Axis Z Axis Up to 60 in Up to 18 in (20 + 5L) µin (60 + 6L) µin Verification grids Gage blocks with length standards Height Gages3 Up to 36 in (25 + 4L) μin Gage blocks/standard reference bar Height Masters Up to 24 in (25 + 4L) μin Gage blocks/standard reference bar Protractor – Digital / Analog (0 to 360) ° 1´ Sine plate, gage blocks, surface plate, indicator II. Dimensional Testing/Calibration 1 Parameter/Equipment Range CMC2, 4 (±) Comments Length – 2D7 Up to 24 in (100 + 3L) µin Vision system
5--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1579.01) 10/06/2025 Page 5 of 13 Parameter/Equipment Range CMC2, 4 (±) Comments Length – 1D7 Up to 40 in (41 to 80) in (5.0 + 3L) µin (10 + 5L) µin Linear comparator, or surface plate metrology III. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 5, 8 (±) Comments DC Voltage3 – Generate (0 to 200) mV 200 mV to 2 V (2 to 20) V (20 to 200) V (200 to 1050) V 5.0 μV/V + 0.1 μV 3.6 μV/V + 0.4 μV 3.6 μV/V + 4.0 μV 5.6 μV/V + 40 μV 5.6 μV/V + 500 μV Fluke 8508A DC Voltage3 – Measure (0 to 200) mV 200 mV to 2 V (2 to 20) V (20 to 200) V (200 to 1050) V (1 to 10) kV (10 to 100) kV 5.0 μV/V + 0.1 μV 3.6 μV/V + 0.4 μV 3.6 μV/V + 4.0 μV 5.6 μV/V + 40 μV 5.6 μV/V + 500 μV 0.042 % + 0.9 V 0.025 % + 42 V Fluke 8508A High voltage DVR-150 & Fluke 8508A DC Current3 – Generate (0 to 200) μA (200 to 2000) μA (2 to 20) mA (20 to 200) mA (200 to 2000) mA (2 to 20) A Up to 200 A (200 to 1000) A 7.0 μA/A + 0.41 nA 6.9 μA/A + 4.1 nA 8.0 μA/A + 41 nA 33 μA/A + 0.8 μA 0.017 % + 16 μA 0.038 % + 0.4 mA 0.25 % + 5 mA 0.25 % + 10 mA Fluke 8508A Transmille 4010/coil DC Current3 – Measure (0 to 200) μA (200 to 2000) μA (2 to 20) mA (20 to 200) mA (200 to 2000) mA (2 to 20) A (20 to 100) A 7.0 μA/A + 0.41 nA 6.9 μA/A + 4.1 nA 8.0 μA/A + 41 nA 33 μA/A + 0.8 μA 0.017 % + 16 μA 0.038 % + 0.4 mA 0.12 % + 5 mA Fluke 8508A Empro 249004
to 40 in
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1579.01) 10/06/2025 Page 6 of 13 Parameter/Equipment Range CMC2, 5 (±) Comments Resistance3 – Generate (0 to 11) Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω (330 to 1100) Ω (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ (330 to 1100) kΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (0.33 to 1) GΩ 0.012 % + 6.0 mΩ 0.012 % + 10 mΩ 90 µΩ/Ω + 10 mΩ 90 µΩ/Ω + 10 mΩ 90 µΩ/Ω + 60 mΩ 90 µΩ/Ω + 60 mΩ 90 µΩ/Ω + 600 mΩ 90 µΩ/Ω + 600 mΩ 0.011 % + 6.0 Ω 0.011 % + 6.0 Ω 0.015 % + 55 Ω 0.015 % + 55 Ω 0.06 % + 550 Ω 0.10 % + 550 Ω 0.50 % + 5.5 k Ω 0.50 % + 17 kΩ 2 % + 100 kΩ Fluke 5500A Transmille 4010 Resistance3 – Measure (0 to 2) Ω (2 to 20) Ω (20 to 200) Ω (200 to 2000) Ω (2 to 20) kΩ (20 to 200) kΩ (200 to 2000) kΩ (2 to 20) MΩ (20 to 200) MΩ (200 to 2000) MΩ (2 to 20) GΩ (20 to 200) GΩ (200 to 2000) GΩ 15 µΩ/Ω + 4.0 µΩ 9.0 µΩ/Ω + 14 µΩ 7.5 µΩ/Ω + 50 µΩ 7.5 µΩ/Ω + 0.5 mΩ 7.5 µΩ/Ω + 5.0 mΩ 7.5 µΩ/Ω + 50 mΩ 8.5 µΩ/Ω + 1.0 Ω 15 µΩ/Ω + 10 Ω 60 µΩ/Ω + 1.0 kΩ 0.015 % + 110 kΩ 0.050 % + 10 MΩ 75 MΩ 12 GΩ Fluke 8508A Fluke 5500A & Fluke 8508A Capacitance3 – Generate (0.33 to 0.5) nF (0.5 to 1.1) nF (1.1 to 3.3) nF (3.3 to 11) nF (11 to 33) nF (33 to 110) nF (110 to 330) nF (330 to 1100) nF (1.1 to 3.3) μF (3.3 to 11) μF (11 to 33) μF (33 to 110) μF (110 to 330) μF (330 to 1100) μF (1.1 to 10) mF (10 to 100) mF 20 pF 0.23 % + 15 pF 0.29 % + 17 pF 0.50 % + 10 pF 0.25 % + 100 pF 0.25 % + 100 pF 0.25 % + 300 pF 0.25 % + 1.0 nF 0.35 % + 3.0 nF 0.35 % + 10 nF 0.40 % + 31 nF 0.50 % + 100 nF 0.70 % + 300 nF 1.0 % + 300 nF 0.5 % + 5 μF 0.5 % + 7 μF Fluke 5500A Transmille 4010
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1579.01) 10/06/2025 Page 7 of 13 Parameter/Equipment Range CMC2, 5 (±) Comments Oscilloscope3 – Bandwidth Vertical Deflection: DC Level: 50 Ω 1 MΩ 1 MΩ 1 MΩ Square Wave: 50 Ω / 1 MΩ 100 mHz to 100 MHz (100 to 550) MHz 550 MHz to 1.1 GHz ± 5.56 V ± 100 mV ± 5 V ± 222 V (35.52 to 1000) µVpp (1 to 21) mVpp (21 to 556) mVpp 556 mV to 10 V (10 to 210) V 1.5 % 3.0 % 4.6 % 0.14 % 0.25 % + 20 µV 0.095 % + 20 µV 0.030 % + 20 mV 1.2 % + 10 µV 0.044 % + 49 µV 0.045 % + 0.45 mV 0.012 % + 8.3 mV 0.061 % + 0.1 V Wavetek 9500 Time Marker: Square Wave Pulse / Triangle 9 ns to 55 s 11 µs/s + 45 ps Wavetek 9500 Electrical Calibration of Thermocouple Indicators & Indicating Systems3 – Type B Type C Type E Type J Type K (600 to 800) °C (800 to 1820) °C (0 to 1000) °C (1000 to 1800) °C (1800 to 2316) °C (-250 to -100) °C (-100 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to 120) °C (120 to 1000) °C (1000 to 1372) °C 0.44 °C 0.34 °C 0.31 °C 0.50 °C 0.84 °C 0.51 °C 0.18 °C 0.21 °C 0.27 °C 0.17 °C 0.23 °C 0.34 °C 0.18 °C 0.26 °C 0.40 °C Fluke 5500A
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1579.01) 10/06/2025 Page 8 of 13 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of Thermocouple Indicators & Indicating Systems3 – (cont.) Type N Type R Type S Type T (-200 to -100) °C (-100 to 410) °C (410 to 1300) °C (0 to 250) °C (250 to 1000) °C (1000 to 1767) °C (0 to 250) °C (250 to 1400) °C (1400 to 1767) °C (-250 to -150) °C (-150 to 0) °C (0 to 400) °C 0.40 °C 0.22 °C 0.27 °C 0.57 °C 0.35 °C 0.40 °C 0.47 °C 0.37 °C 0.46 °C 0.63 °C 0.24 °C 0.16 °C Fluke 5500A Electrical Calibration of RTD Indicators & Indicating Systems 3 – Pt 385, 100 Ω Pt 385, 100 Ω (-200 to 200) °C (200 to 600) °C (600 to 800) °C (-200 to 0) °C (0 to 400) °C (400 to 800) °C 0.10 °C 0.20 °C 0.30 °C 0.051 °C 0.10 °C 0.14 °C Beamex MC2 Fluke 5500A
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1579.01) 10/06/2025 Page 9 of 13 Parameter/Range Frequency CMC2, 5, 8, 12 (±) Comments AC Voltage3 – Measure (0 to 200) mV 200 mV to 2 V (2 to 20) V (20 to 200) V (200 to 1050) V (1 to 10) kV (10 to 100) kV (50 to 100) Hz (100 to 2000) Hz (50 to 100) Hz (100 to 2000) Hz (50 to 100) Hz (100 to 2000) Hz (50 to 100) Hz (100 to 2000) Hz (50 to 100) Hz (100 to 2000) Hz 60 Hz 60 Hz 0.010 % + 4.0 µV 0.010 % + 2.0 µV 80 μV/V + 20 µV 60 μV/V + 20 µV 80 μV/V + 0.2 mV 60 μV/V + 0.2 mV 80 μV/V + 2.0 mV 60 μV/V + 2.0 mV 90 μV/V + 27 mV 0.50 % + 0.3 V 0.57 % Fluke 8508A High voltage DVR- 150 & Fluke 8508A AC Voltage3 – Generate (0 to 200) mV 200 mV to 2 V (2 to 20) V (20 to 200) V (200 to 1050) V (50 to 100) Hz (100 to 2000) Hz (50 to 100) Hz (100 to 2000) Hz (50 to 100) Hz (100 to 2000) Hz (50 to 100) Hz (100 to 2000) Hz (50 to 2000) Hz 0.010 % + 4.0 µV 0.010 % + 2.0 µV 80 μV/V + 20 µV 60 μV/V + 20 µV 80 μV/V + 0.2 mV 60 μV/V + 0.2 mV 80 μV/V + 2.0 mV 60 μV/V + 2.0 mV 90 μV/V + 27 mV Fluke 8508A AC Current3 – Generate (0 to 200) µA (200 to 2000) μA (2 to 20) mA (20 to 200) mA (200 to 2000) mA (2 to 20) A Up to 200 A (200 to 1000) A Up to 200 A (200 to 1000) A (10 to 10 000) Hz (10 to 10 000) Hz (10 to 10 000) Hz (10 to 10 000) Hz (10 to 2000) Hz (10 to 2000) Hz (45 to 65) Hz (45 to 65) Hz (65 to 440) Hz (65 to 440) Hz 0.025 % + 20 nA 0.025 % + 0.2 μA 0.025 % + 2.0 μA 0.025 % + 20 μA 0.060 % + 200 μA 0.080 % + 2.0 mA 0.17 % 0.11 % + 0.54 A 0.48 % 0.33 % + 0.37 A Fluke 8508A Transmille 4010/coil Transmille 4010/coil
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1579.01) 10/06/2025 Page 10 of 13 Parameter/Range Frequency CMC2, 5, 8, 12 (±) Comments AC Current3 – Measure (0 to 200) µA (200 to 2000) μA (2 to 20) mA (20 to 200) mA (200 to 2000) mA (2 to 20) A (20 to 100) A (10 to 10 000) Hz (10 to 10 000) Hz (10 to 10 000) Hz (10 to 10 000) Hz (10 to 2000) Hz (10 to 2000) Hz (40 to 100) Hz 0.025 % + 20 nA 0.025 % + 0.2 μA 0.025 % + 2.0 μA 0.025 % + 20 μA 0.060 % + 200 μA 0.080 % + 2.0 mA 0.28 % + 4.0 mA Fluke 8508A Empro 249004 IV. Mechanical Parameter/Equipment Range CMC 2 (±) Comments Balances & Scales3 Up to 50g Up to 250 g Up to 500 g Up to 2000 g Up to 6000 g Up to 15 000 g Up to 20 000 g Up to 40 000 g Up to 30 lb Up to 70 lb Up to 100 lb Up to 150 lb Up to 330lb Up to 660 lb Up to 1000 lb 0.13 mg 0.64 mg 2.0 mg 0.015 g 0.020 g 0.16 g 0.22 g 2.3 g 0.0033 lb 0.0072 lb 0.017 lb 0.019 lb 0.13 lb 0.13 lb 0.25 lb Class 1 & 3 weights Class 6 weights Force3 – Measure, Tension & Compression Up to 4 lbf Up to 50 lbf Up to 100 lbf Up to 250 lbf Up to 500 lbf Up to 1000 lbf (1000 to 10 000) lbf (10 000 to 30 000) lbf 0.0018 lbf 0.016 lbf 0.018 lbf 0.033 lbf 0.070 lbf 0.13 lbf 0.5 % 0.5 % Class 1, 3, & 6 weights Load cells
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1579.01) 10/06/2025 Page 11 of 13 Parameter/Equipment Range CMC2, 8, 10, 11, 14 (±) Comments Torque Wrenches Up to 100 oz·in 5 lb-in to 250 lb·ft 250 lb·ft to 2000 lb·ft 1.0 % 0.5 % 1.0 % Torque calibrator Torque Calibrators Up to 10 ozf·in Up to 100 ozf·in Up to 50 lbf·in Up to 400 lbf·in Up to 1000 lbf·in Up to 250 lbf·ft Up to 600 lbf·ft Up to 2000 lbf·ft 0.025 ozf·in 0.15 ozf·in 0.015 lbf·in 0.091 lbf·in 0.22 lbf·in 0.067 lbf·ft 0.21 lbf·ft 0.32 lbf·ft Precision weights, arms, wheels, & trays Vacuum3 – Negative Pressure – Measure (-14.5 to 0) psi 0.030 % + 0.0025 psi Beamex EXT-1C Pressure3 – Measure Pneumatic Hydraulic (0 to 12) inH 2O Up to 40 inH2O Up to 15 psi Up to 30 psi Up to 90 psi Up to 300 psi Up to 900 psi Up to 500 psig Up to 8000 psig Up to 16 000 psig 0.0024 inH2O 0.025 % + 0.011 inH2O 0.025 % + 0.0023 psi 0.025 % + 0.003 psi 0.025 % + 0.01 psi 0.025 % + 0.03 psi 0.025 % + 0.09 psi 0.013 % + 0.012 psi 0.011 % + 0.7 psi 0.011 % + 0.8 psi Dwyer 1425 Beamex EXT100m Beamex EXT1C Beamex EXT2C Beamex EXT6C Beamex EXT20C Beamex EXT60 Pressurements 2800/3 V. Thermodynamics Parameter/Equipment Range CMC2, 8, 10 (±) Comments Relative Humidity3 – Measure (10 to 90) % RH (90 to 97) % RH 0.35 % + 1.1 % RH 2.0 % RH Vaisala MI70, HMP76
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1579.01) 10/06/2025 Page 12 of 13 Parameter/Equipment Range CMC2, 8, 10 (±) Comments Relative Humidity3 – Measuring Equipment 11 % RH 23 % RH 33 % RH 43 % RH 75 % RH 85 % RH 95 % RH 1.1 % RH 1.2 % RH 1.2 % RH 1.3 % RH 1.4 % RH 1.4 % RH 2.0 % RH Vaisala MI70, HMP76, salts Temperature – Measure3 (-200 to 660) °C 0.0035 % + 0.013 °C Fluke 5609, 1502A PRT Temperature – Measuring Equipment3 (-5 to 126) °C (126 to 660) °C 0.039 °C 0.0022 % + 0.036 °C Hart 7102 w/PRT Fluke 9173 w/PRT Infrared Temperature – Measuring Equipment (35 to 100) °C (100 to 200) °C (200 to 350) °C (350 to 500) °C 0.62 °C 0.84 °C 1.4 °C 1.9 °C Fluke 4181 IR blackbody VI. Time & Frequency Parameter/Equipment Range CMC2, 10 (±) Comments Timers & Clocks 1 ms to 1 s (1 to 100) s (100 to 3600) s 220 ns 45 µs/s + 350 ns 41 ms Agilent 53132A Frequency3 – Measuring Equipment Sine Wave Square Wave Triangular Wave 100 μHz to 15 MHz 100 μHz to 15 MHz 100 μHz to 100 kHz 21 µHz/Hz + 5 mHz 20 µHz/Hz + 5 mHz 21 µHz/Hz + 0.5 mHz Agilent 33120A Frequency3 – Measure (0.1 to 1000) Hz (1 to 1000) kHz (1 to 225) MHz 0.38 mHz 44 nHz/Hz + 4.4 mHz 47 nHz/Hz + 0.15 Hz Agilent 53132A _______________________________________________
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1579.01) 10/06/2025 Page 13 of 13 1 This laboratory offers commercial and field calibration and dimensional testing services. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches; D is the numerical value of the nominal diameter of the device measured in inches. 5 The measurands stated are generated with the Fluke 5500A , Fluke 5700A, Fluke 8508A, Fluke 89 and Transmille 4010 series of instruments. This capability is suitable for the calibration of the devices intended to measure the stated measurand in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a fraction or percentage of the reading plus a fixed floor specification. 6 The measurands stated are generated with the Wavetek 9500. This capability is suitable for the calibration of the devices intended to measure the stated measurand in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percentage of output plus one -year floor specifications where defined. 7 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for the types of dimensional tests listed above and is considered equivalent to that of a calibration. 8 In the statement of CMC, percentages are to be read as percentage of reading, unless otherwise noted. 9 Calibration of adjustable thread ring gages above 2.625 inches is performed with a customer supplied compatible Class X thread setting plug gage - subject to calibration by HJM Precision. 10 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 11 In the statement of CMC, psi is to be read as pounds per square inch. 12 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 13 The scope meets A2LA’s P112 Flexible Scope Policy. 14 In the statement of CMC, percentages are to be read as percentage of the absolute value of the reading, unless otherwise noted.
14ISO/IEC 17025:20 17; ANSI/NCSL Z540-1-1994; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

9 New Turnpike Road, Troy, NY, 12182, US

42.72841, -73.69179

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.