CONNECTICUT CALIBRATION TECHNOLOGIES, INC., dba CONNECTICUT CALIBRATION

327 S. Main Street, 06470, Newtown, CT, United States

Visit website
A2LA 2010.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
14
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 14 scope lines.

A2LA certificate 2010.01 · 14 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-0 to 360 °
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2010.01) 2/14/2025 Page 2 of 13 Parameter/Equipment Range CMC2, 5 (±) Comments Pins (0.011 to 1) in 55 µin Laser micrometer, master pins Crimpers3 (0.011 to 0.5) in 240 µin Meyer plus, Meyer minus Micrometers3 Up to 12.000 in Up to 100 mm (32 + 2.5L + 0.6RD) µin (0.92 + 0.003L + 0.6RD) µm Gage blocks Fixture & Attribute Gages Up to 6 in (76 + 18L) µin Micrometer III. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 4, 6 (±) Comments DC Voltage – Generate (0 to 330) mV 330 mV to 3.3 V (3.3 to 33) V (33 to 330) V (100 to 1000) V (1 to 5) kV (5 to 10) kV 35 µV/V + 1 µV 17 µV/V + 2 µV 20 µV/V + 20 µV 25 µV/V + 150 µV 20 µV/V + 1500 µV 9.7 V 11 V Fluke 5520A Keithley 2290-10 DC Voltage – Measure3 (0 to 100) mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 1100) V (1 to 40) kV 29 µV/V + 0.3 µV 13 µV/V + 0.3 µV 15 µV/V + 0.5 µV 18 µV/V + 30 µV 10 µV/V + 100 µV 2.5 % HP 3458A opt 002 Amprobe HU231- 10A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2010.01) 2/14/2025 Page 3 of 13 Parameter/Equipment Range CMC2, 4, 6 (±) Comments DC Current – Generate Clamp-on Only (0 to 330) µA 330 µA to 3.3 mA (3.3 to 33) mA (33 to 330) mA 330 mA to 1.1 A (1.1 to 3) A (3 to 11) A (11 to 20) A (20 to 150) A (150 to 1000) A 0.02 % + 0.02 µA 0.01 % + 0.05 µA 0.01 % + 0.25 µA 0.011 % + 2.5 µA 0.022 % + 40 µA 0.039 % + 40 µA 0.051 % + 500 µA 0.1 % + 750 µA 0.64 % + 0.16 A 0.65 % + 0.58 A Fluke 5520A with 5500A coil DC Current – Measure3 (0 to 10) µA (10 to 100) µA 100 µA to 1 mA (1 to 10) mA (10 to 100) mA 100 mA to 1 A (1 to 50) A 0.015 % + 40 pA 0.015 % + 100 pA 35 µA/A + 800 pA 37 µA/A + 5 nA 61 µA/A + 50 nA 0.012 % + 500 nA 0.3 % HP 3458A opt 002 Agilent 3458A with Empro 50-50 DC Resistance – Generate (0 to 11) Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω (0.33 to 1.1) kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ (0.33 to 1.1) MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (0.33 to 1.1) GΩ 56 µΩ/Ω + 0.001 Ω 51 µΩ/Ω + 0.0018 Ω 43 µΩ/Ω + 0.0014 Ω 32 µΩ/Ω + 0.002 Ω 30 µΩ/Ω + 0.002 Ω 30 µΩ/Ω + 0.02 Ω 29 µΩ/Ω + 0.02 Ω 30 µΩ/Ω + 0.2 Ω 29 µΩ/Ω + 0.2 Ω 37 µΩ/Ω + 2 Ω 34 µΩ/Ω + 2 Ω 150 µΩ/Ω + 30 Ω 0.014 % + 50 Ω 0.047 % + 2.5 kΩ 0.45 % + 3 kΩ 0.46 % + 100 kΩ 1.5 % + 500 kΩ Dale ECN 250 Fluke 5520A DC Resistance – Measure3 (0 to 10) Ω (10 to 100) Ω 100 Ω to 1 kΩ (1 to 10) kΩ (10 to 100) kΩ 33 µΩ/Ω + 50 µΩ 34 µΩ/Ω + 500 µΩ 16 µΩ/Ω + 500 µΩ 14 µΩ/Ω + 5 mΩ 14 µΩ/Ω + 50 mΩ HP 3458A opt 002
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2010.01) 2/14/2025 Page 4 of 13 Parameter/Equipment Range CMC2, 6 (±) Comments DC Resistance – Measure3 (cont) 100 kΩ to 1 MΩ (1 to 10) MΩ (10 to 100) MΩ 100 MΩ to 1 GΩ 19 µΩ/Ω + 2 Ω 57 µΩ/Ω + 100 Ω 0.063 % + 1 kΩ 0.5 % + 10 kΩ HP 3458A opt 002 Parameter/Range Frequency CMC2, 6 (±) Comments AC Voltage – Generate (1 to 33) mV (33 to 330) mV (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.092 % + 6 µV 0.048 % + 6 µV 0.026 % + 6 µV 0.10 % + 6 µV 0.35 % + 12 µV 0.80 % + 50 µV 0.033 % + 8 µV 0.019 % + 8 µV 0.020 % + 8 µV 0.038 % + 8 µV 0.081 % + 32 µV 0.20 % + 70 µV 0.034 % + 50 µV 0.018 % + 60 µV 0.024 % + 60 µV 0.037 % + 50 µV 0.074 % + 130 µV 0.24 % + 600 µV 0.033 % + 650 µV 0.020 % + 600 µV 0.027 % + 600 µV 0.039 % + 600 µV 0.092 % + 1.6 mV 0.027 % + 2 mV 0.028 % + 6 mV 0.031 % + 6 mV 0.037 % + 6 mV 0.20 % + 50 mV 0.035 % + 10mV 0.029 % + 10 mV 0.034 % + 10 mV Fluke 5520A
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2010.01) 2/14/2025 Page 5 of 13 Parameter/Range Frequency CMC2, 4, 5, 6 (±) Comments AC Voltage – Measure3 (1 to 10) mV (10 to 100) mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 1000) V (1 to 40) kV (1 to 20) kV 45 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 45 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz 45 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz 45 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz 45 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 45 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (60 to 400) Hz 400 Hz to 75 MHz 0.03 % + 1.1 µV 0.04 % + 1.1 µV 0.1 % + 1.1 µV 0.5 % + 1.1 µV 4 % + 2 µV 0.019 % + 2 µV 0.022 % + 2 µV 0.04 % + 2 µV 0.08 % + 2 µV 0.3 % + 10 µV 1 % + 10 µV 0.013 % + 0.2mV 0.021 % + 0.2mV 0.04 % + 0.2mV 0.08 % + 0.2mV 0.3 % + 1 mV 1 % + 1 mV 0.015 % + 0.2mV 0.02 % + 0.2mV 0.04 % + 0.2mV 0.09 % + 0.2mV 0.3 % + 11 mV 1 % + 1 mV 0.03 % + 2 mV 0.03 % + 2 mV 0.042 % + 2 mV 0.12 % + 10 mV 0.4 % + 10 mV 0.06 % + 20 mV 0.08 % + 20 mV 0.13 % + 20 mV 6.4 % 3.6 % + 0.6R HP 3458A opt 002 Amprobe HU231- 10A Tektronix P6015
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2010.01) 2/14/2025 Page 6 of 13 Parameter/Range Frequency CMC2, 6 (±) Comments AC Current – Generate (29 to 330) µA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 3.0) A (3 to 11) A (11 to 20.5) A Clamp-On Only: (20 to 150) A (150 to 550) A (550 to 1000) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz 45 Hz to 1.0 kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz @ 60 Hz @ 60 Hz @ 60 Hz 0.23 % + 0.1 µA 0.19 % + 0.1 µA 0.17 % + 0.1 µA 0.31 % + 0.15 µA 0.81 % + 0.2 µA 1.6 % + 0.4 µA 0.21 % + 0.15 µA 0.15 % + 0.15µA 0.13 % + 0.15 µA 0.21 % + 0.2 µA 0.51 % + 0.30 µA 1.0 % + 0.6 µA 0.18 % + 1.0 µA 0.09 % + 2.0 µA 0.08 % + 2.0 µA 0.11 % + 2.0 µA 0.22 % + 3.0 µA 0.41 % + 4.0 µA 0.20 % + 20 µA 0.10 % + 20 µA 0.09 % + 20 µA 0.13 % + 50 µA 0.21 % + 100 µA 0.41 % + 200 µA 0.19 % + 100 µA 0.10 % + 100 µA 1.5 % + 1 mA 2.5 % + 5 mA 0.59 % + 2 mA 0.14 % + 2 mA 3.0 % + 2 mA 0.16 % + 5 mA 0.52 % + 5 mA 3.0 % + 5 mA 0.63 % + 0.16 A 0.85 % + 0.58 A 0.64 % + 0.58 A Fluke 5520A with 5500A coil
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2010.01) 2/14/2025 Page 7 of 13 Parameter/Range Frequency CMC2, 6 (±) Comments AC Current – Measure3 (5 to 100) µA 100 µA to 1 mA (1 to 10) mA (10 to 100) mA 100 mA to 1 A (10 to 20) Hz (20 to 45) Hz 45 Hz to 100 Hz 100 Hz to 1 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz 0.41 % + 30 nA 0.17 % + 30 nA 0.10 % + 30 nA 0.08 % + 30 nA 0.40 % + 0.2 µA 0.15 % + 0.2 µA 0.062 % + 0.2 µA 0.033 % + 0.2 µA 0.071 % + 0.2 µA 0.40 % + 0.4 µA 0.40 % + 2 µA 0.15 % + 2 µA 0.061 % + 2 µA 0.034 % + 2 µA 0.067 % + 2 µA 0.40 % + 4 µA 0.40 % + 20 µA 0.15 % + 20 µA 0.061 % + 20 µA 0.031 % + 20 µA 0.062 % + 20 µA 0.40 % + 40 µA 0.40 % + 0.2 mA 0.16 % + 0.2 mA 0.081 % + 0.2mA 0.10 % + 0.2 mA 0.30 % + 0.2 mA 1.0 % + 0.4 mA HP 3458A opt 002
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2010.01) 2/14/2025 Page 8 of 13 Parameter/Range Frequency CMC2, 6 (±) Comments Capacitance – Generate (0.19 to 0.4) nF (0.4 to 1.1) nF (1.1 to 3.3) nF (3.3 to 11) nF (11 to 33) nF (33 to 110) nF (110 to 330) nF (0.33 to 1.1) µF (1.1 to 3.3) µF (3.3 to 11) µF (11 to 33) µF (33 to 110) µF (110 to 330) µF (0.33 to 1.1) mF (1.1 to 3.3) mF (3.3 to 11) mF (11 to 33) mF (33 to 110) mF 10 Hz to 10 kHz 10 Hz to 10 kHz 10 Hz to 3 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz (10 to 600) Hz (10 to 300) Hz (10 to 150) Hz (10 to 120) Hz Up to 80 Hz Up to 50 Hz Up to 20 Hz Up to 6 Hz Up to 2 Hz Up to 0.6 Hz Up to 0.2 Hz 3.4 % + 0.01 nF 1.6 % + 0.01 nF 0.58 % + 0.01 nF 0.28 % + 0.01 nF 0.28 % + 0.1 nF 0.28 % + 0.1 nF 0.28 % + 0.3 nF 0.28 % + 1 nF 0.27 % + 3 nF 0.27 % + 10 nF 0.41 % + 30 nF 0.46 % + 100 nF 0.45 % + 300 nF 0.45 % + 1 nF 0.45 % + 3 nF 0.45 % + 10 nF 0.75 % + 30 nF 1.1 % + 100 nF Fluke 5520A Inductance – Generate3 @ 100 mH @ 1 kHz 0.1 mH GenRad 1842L Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of Thermocouple Indicators3 – Type E Type J (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C 0.55 °C 0.28 °C 0.27 °C 0.28 °C 0.32 °C 0.36 °C 0.28 °C 0.27 °C 0.29 °C 0.33 °C Fluke 5520A
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2010.01) 2/14/2025 Page 9 of 13 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of Thermocouple Indicators3 – (cont) Type K Type T (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.40 °C 0.30 °C 0.28 °C 0.35 °C 0.46 °C 0.67 °C 0.34 °C 0.28 °C 0.27 °C Fluke 5520A Electrical Calibration of RTDs – Pt 385, 100 Ω Pt 385, 200 Ω Pt 385, 1000 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C 0.07 °C 0.07 °C 0.09 °C 0.10 °C 0.11 °C 0.13 °C 0.24 °C 0.08 °C 0.08 °C 0.08 °C 0.09 °C 0.14 °C 0.15 °C 0.16 °C 0.17 °C 0.04 °C 0.04 °C 0.05 °C 0.05 °C 0.06 °C 0.07 °C 0.07 °C 0.23 °C Fluke 5520A
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2010.01) 2/14/2025 Page 10 of 13 Parameter/Equipment Range CMC2, 4 (±) Comments Electrical Calibration of RTDs – Pt 3916, 100 Ω Pt 3926, 100 Ω (-200 to -190) °C (-190 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C 0.26 °C 0.06 °C 0.07 °C 0.08 °C 0.09 °C 0.09 °C 0.10 °C 0.11 °C 0.24 °C 0.07 °C 0.07 °C 0.09 °C 0.10 °C 0.11 °C 0.13 °C Fluke 5520A Oscilloscopes – Amplitude Square Wave Signal, 50 Ω @ 1 kHz 1 MΩ Leveled Sine Wave Characteristics Into 50 Ω Square Wave Signal Frequency Accuracy Amplitude (Relative to 50 kHz) Time Marker Into 50 Ω (0 to 6.6) V 1 mV to 130 V 50 kHz (Reference) 50 kHz to 100MHz (100 to 300) MHz (300 to 600) MHz (600 to 1100) MHz (10 to 100) kHz 50 kHz to 100 MHz (101 to 300) MHz (301 to 600) MHz (601 to 1100) MHz 5 s to 50 ms 20 ms to 10 ns (5 to 2) ns 0.26 % + 40 µV 0.10 % + 40 µV 2 % + 300 µV 3.5 % + 300 µV 4 % + 300 µV 6 % + 300 µV 7 % + 300 µV 2.5 µHz/Hz 1.5 % + 100 µV 2.0 % + 100 µV 4.0 % + 100 µV 5.0 % + 100 µV 25 µs/s + t·1000 µs/s 3 µs/s 4 µs/s Fluke 5520A option SC1100 & Agilent 3458A opt 002 Fluke 5520A option SC1100 t is the time in seconds
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2010.01) 2/14/2025 Page 11 of 13 IV. Mechanical Parameter/Equipment Range CMC2, 4, 5, 7 (±) Comments Torque – Measuring Equipment (5 to 50) lbf·in (>50 to 300) lbf·in (25 to 100) lbf·ft (>100 to 600) lbf·ft 0.4 lbf·in 1.8 lbf·in 2.6 lbf·ft 4.9 lbf·ft Sturtevant-Richmont torque tester Snap-on torque testers Scales & Balances3 (1 to 1000) g (1000 to 20 000)g Up to 25 lb [Up to 11.3398 kg] (25 to 50) lb [(11.3398 to 22.6796) kg] (50 to 200) lb [(22.6796 to 90.7185) kg] 1 mg + 0.6R 1.1 g + 0.6R 0.1 g + 0.6R 0.3 g + 0.6R 0.7 lb + 0.6R Class 1 weights Class F weights Pressure Gages (1 to 300) psi (10 to 1000) psi (1000 to 10 000) psi 0.15 psi + 0.6R 0.03 % + 0.6R 8 psi + 0.6R Fluke 718 Ametek HK-1000 Fluke 700HTP2 Force3 – Measure & Measuring Equipment Fixed Points 0.25 oz to 25 lbf [7.1 gf to 11.3398 kgf] 25 lbf 50 lbf 75 lbf 100 lbf 125 lbf 150 lbf 200 lbf 210 mgf + 0.6R 0.0017 lbf + 0.6R 0.0036 lbf + 0.6R 0.0052 lbf + 0.6R 0.0067 lbf + 0.6R 0.0083 lbf + 0.6R 0.0097 lbf + 0.6R 0.012 lbf + 0.6R Heusser Neweigh Class F weights Rice Lake: 1203 1207 1203, 1207 1207, 1208 1207, 1208, 1203 1207, 1208, 1203, 1204 ALL
12--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2010.01) 2/14/2025 Page 12 of 13 V. Thermodynamics Parameter/Equipment Range CMC2, 7 (±) Comments Temperature – Measure (-35 to 350) °C 0.79 °C Fluke 9140 dry well Temperature – Measuring Equipment 0 °F (>0 to 400) °F (>400 to 600) °F (>600 to 800) °F 0.5 °F 4.8 °F 5.1 °F 6.8 °F Fluke 714 thermocouples Relative Humidity – Measure3 Up to 90 % RH (90 to 98) % RH 1.9 % RH 2.5 % RH Vaisala MI70/HMP77 VI. Time & Frequency Parameter/Equipment Range CMC2, 5, 7 (±) Comments Frequency – Measuring Equipment 10 MHz 0.16 Hz Efratom frequency standard Frequency – Measure3 1 Hz to 1.1 GHz 0.27 Hz HP 5334B Stopwatches3 (0 to 86 400) s/day 0.96 s/day + 0.6R Master stopwatch ___________________________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC percent refers to percent of reading unless otherwise noted.
-35 to 350 °C
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2010.01) 2/14/2025 Page 13 of 13 5 L is the length in inches/mm of the unit under test , RD is the resolution in inches/mm for dimensional calibrations, and R is the resolution of the unit under test for all other calibrations. 6 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC are expressed as either a specific value that covers the full range or as a fraction of the reading plus a fixed floor specification. 7 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 8 This scope meets A2LA’s P112 Flexible Scope Policy.
14ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.