AH Electronic Test Equipment Repair Center
374 Islip Ave, Suite #201, 11751, Islip, NY, United States
Visit website- Scope lines
- 22
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 22 scope lines.
A2LA certificate 2635.01 · 22 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; IEC 17025; ANSI/NCSL Z540-1-1994 | AIR; ELECTRONIC | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2635.01) 07/08/2025 Page 2 of 21
Parameter/Equipment
Range
CMC2, 4, 7 (±)
Comments
DC Voltage – Measure
(0 to 200) mV
(0.2 to 2) V
(2 to 20) V
(20 to 200) V
(200 to 1000) V
(10 to 100) mV
(0.1 to 1.0) V
(1.0 to 10) V
(10 to 100) V
(100 to 1000) V
(1 to 40) kV
(1 to 100) kV
0.0005 % + 93 µV
0.0003 % + 0.70 µV
0.0003 % + 7.0 µV
0.0005 % + 70 µV
0.0005 % + 740 µV
0.0004 % + 0.28 µV
0.0003 % + 0.28 µV
0.0003 % + 0.47 µV
0.0005 % + 28 µV
0.0005 % + 82 µV
1 %
0.5 %
Fluke 8508A
Agilent
3458A/100PLC,
option 002
Add 12(Vin/1000)
2
µV/V for Vin> 100 V
Fluke 80K-40
Spellman HVD-100-1
DC Current – Generate
Toroidal Clamps
Other Clamps
(0 to 329.99) µA
(0 to 3.299 99) mA
(0 to 32.9999) mA
(0 to 329.999) mA
(0 to 1.099 99) A
(1.1 to 2.9999) A
(0 to 10.9999) A
(11 to 20.5) A
(10 to 16.4999) A
(16.5 to 149.999) A
(150 to 1025) A
(10 to 16.4999) A
(16.5 to 149.999) A
(150 to 1025) A
(0 to 220) µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
0.012 % + 0.12 µA
0.0078 % + 0.12 µA
0.0078 % + 0.23 µA
0.0078 % + 1.9 µA
0.016 % + 31 µA
0.030 % + 31 µA
0.039 % + 0.39 mA
0.078 % + 0.58 mA
0.19 % + 1.6 mA
0.19 % + 12 mA
0.19 % + 39 mA
0.39 % + 16 mA
0.39 % + 110 mA
0.39 % + 390 mA
0.0039 % + 5.4 nA
0.0031 % + 6.2 nA
0.0031 % + 39 nA
0.0039 % + 0.62 µA
0.0070 % + 1.2 µA
Fluke 5522A
Fluke 5522A/coil
Fluke 5720A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2635.01) 07/08/2025 Page 3 of 21
Parameter/Equipment
Range
CMC2, 4, 7 (±)
Comments
DC Current – Measure
(0 to 200) µA
(0.2 to 2) mA
(2 to 20) mA
(20 to 200) mA
(0.2 to 2) A
(2 to 20) A
(10 to 100) µA
(0.1 to 1) mA
(10 to 100) mA
(0.1 to 1) A
0.0012 % + 0.31 µA
0.0012 % + 3.1 µA
0.0014 % + 0.07 µA
0.0047 % + 0.85 µA
0.018 % + 14 µA
0.039 % + 320 µA
0.0002 % + 0.09 nA
0.0002 % + 0.93 nA
0.0002 % + 0.09 µA
0.0002 % + 1.7 µA
Fluke 8508A
Agilent 3458A/100
PLC, option 002
Resistance – Generate
Fixed Points
(0 to 10.99) Ω
(11 to 32.999) Ω
(33 to 109.999) Ω
(110 to 329.999) Ω
(330 to 1.0999) kΩ
(1.1 to 3.299 99) kΩ
(3.3 to 10.9999) kΩ
(11 to 32.9999) kΩ
(33 to 109.999) kΩ
(110 to 329.999) kΩ
(330 to 1099.99) kΩ
(1.1 to 3.299 99) MΩ
(3.3 to 10.999) MΩ
(11 to 32.9999) MΩ
(33 to 109.999) MΩ
(110 to 330) MΩ
(330 to 1100) MΩ
1 Ω
1.9 Ω
10 Ω
19 Ω
100 Ω
190 Ω
1 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
0.0031 % + 7.8 mΩ
0.0023 % + 1.2 mΩ
0.0022 % + 1.1 mΩ
0.0022 % + 1.6 mΩ
0.0022 % + 1.6 mΩ
0.0022 % + 16 mΩ
0.0022 % + 16 mΩ
0.0022 % + 160 mΩ
0.0022 % + 1.6 Ω
0.0025 % + 1.6 Ω
0.025 % + 1.6 Ω
0.05 % + 2.3 Ω
0.01 % + 3.9 Ω
0.02 % + 190 Ω
0.04 % + 230 Ω
0.23 % + 780 Ω
1.2 % + 3.9 k Ω
0.0085 %
0.0085 %
0.0021 %
0.0021 %
0.0009 %
0.0009 %
0.0008 %
0.0008 %
0.0008 %
0.0008 % + 0.01 Ω
0.0010 % + 0.01 Ω
0.0010 % + 0.06 Ω
0.0018 % + 0.06 Ω
0.0019 % + 0.58 Ω
0.0036 % + 0.58 Ω
0.0043 % + 5.8 Ω
0.0093 % + 5.8 Ω
Fluke 5522A
Fluke 5720A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2635.01) 07/08/2025 Page 4 of 21
Parameter/Equipment
Range3
CMC2, 4, 7 (±)
Comments
Resistance – Measure
(0 to 10) Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1.0) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
(0.1 to 1.0) GΩ
0.0001 % + 11 µΩ
0.0001 % + 93 µΩ
0.0001 % + 110 µΩ
0.0001 % + 1.1 mΩ
0.0001 % + 11 mΩ
0.0001 % + 5.9 Ω
0.0004 % + 19 Ω
0.0019 % + 190 Ω
0.019 % + 1.9 kΩ
Agilent 3458A/PLC
100, option 002
DC Power – Generate
33 mV to 1020 V
109 µW to 1 mW
(1 to 11) mW
(11 to 108) mW
108 mW to 11 W
11 W to 5 kW
(5 to 12) kW
0.02 %
0.02 %
0.05 %
0.02 %
0.02 %
0.05 %
Fluke 5522A
Parameter/Range
Frequency
CMC2, 4, 7 (±)
Comments
Distortion – Measure
20 Hz to 20 kHz
(20 to 100) kHz
1 dB
2 dB
HP 8903A
AC Voltage – Generate
(0.22 to 2.2) mV
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 300) kHz
(30 to 500) kHz
(0.5 to 1) MHz
0.024 % + 3.9 µV
0.0089 % + 3.9 µV
0.0078 % + 3.9 µV
0.020 % + 3.9 µV
0.047 % + 4.7 µV
0.11 % + 9.3 µV
0.14 % + 19 µV
0.27 % + 19 µV
Fluke 5720A | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2635.01) 07/08/2025 Page 5 of 21
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Voltage – Generate
(cont)
(2.2 to 22) mV
(22 to 220) mV
(0.22 to 2.2) V
(2.2 to 22) V
(22 to 220) V
(220 to 1100) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 300) kHz
(30 to 500) kHz
500 kHz to 1MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 300) kHz
(30 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 300) kHz
(30 to 500) kHz
500 kHz to 1MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 300) kHz
(30 to 500) kHz
500 kHz to 1MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 300) kHz
(30 to 500) kHz
500 kHz to 1MHz
(15 to 50) Hz
50 Hz to 1 kHz
0.023 % + 3.9 µV
0.0089 % + 3.9 µV
0.0078 % + 3.9 µV
0.020 % + 3.9 µV
0.047 % + 4.7 µV
0.11 % + 9.3 µV
0.14 % + 19 µV
0.27 % + 19 µV
0.024 % + 12 µV
0.0089 % + 6.2 µV
0.0078 % + 6.2 µV
0.020 % + 6.2 µV
0.047 % + 16 µV
0.11 % + 19 µV
0.14 % + 23 µV
0.26 % + 47 µV
0.024 % + 39 µV
0.0085 % + 16 µV
0.0040 % + 7.8 µV
0.0070 % + 9.3 µV
0.011 % + 31 µV
0.039 % + 78 µV
0.093 % + 190 µV
0.16 % + 310 µV
0.023 % + 39 µV
0.0081 % + 17 µV
0.0039 % + 9.7 µV
0.0067 % + 11 µV
0.0098 % + 32 µV
0.036 % + 78 µV
0.090 % + 190 µV
0.15 % + 310 µV
0.024 % + 3.9 mV
0.0085 % + 1.6 mV
0.0050 % + 540 mV
0.0078 % + 0.93 mV
0.014 % + 2.3 mV
0.086 % + 16 mV
0.42 % + 39 mV
0.78 % + 78 mV
0.028 % + 16 mV
0.0066 % + 3.1 mV
Fluke 5720A
Subject to 2.2 x 10
7
V-Hz limitation | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2635.01) 07/08/2025 Page 6 of 21
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Voltage – Measure
(0 to 200) mV
(0.2 to 2) V
(0.2 to 2) V
(2 to 20) V
(20 to 200) V
(200 to 1000) V
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
(1 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1MHz
(1 to 10) Hz
(1 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1MHz
(1 to 10) Hz
(1 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1MHz
(1 to 10) Hz
(1 to 40) Hz
(40 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
0.016 % + 12 µV
0.013 % + 3.9 µV
0.011 % + 3.9 µV
0.011 % + 2.0 µV
0.013 % + 3.9 µV
0.031 % + 7.8 µV
0.067 % + 19 µV
0.015 % + 110 µV
0.011 % + 19 µV
0.0085 % + 19 µV
0.0070 % + 19 µV
0.011 % + 19 µV
0.021 % + 39 µV
0.051 % + 190 µV
0.24 % + 6.1 µV
0.78 % + 19 µV
0.015 % + 58 µV
0.011 % + 190 µV
0.0085 % + 190 µV
0.0070 % + 190 µV
0.011 % + 190 µV
0.021 % + 390 µV
0.051 % + 58 µV
0.24 % + 61 µV
0.78 % + 190 µV
0.015 % + 580 µV
0.011 % + 580 µV
0.0085 % + 580 µV
0.0070 % + 580 µV
0.011 % + 580 µV
0.021 % + 580 µV
0.051 % + 580 µV
0.24 % + 610 µV
0.78 % + 580 µV
0.015 % + 5.8 mV
0.012 % + 5.8 mV
0.011 % + 5.8 mV
0.021 % + 5.8 mV
0.055 % + 5.8 mV
Fluke 8508A | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2635.01) 07/08/2025 Page 7 of 21
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Voltage –Measure
(2 to 12) mV
(12 to 120) mV
(0.12 to 1.2) V
(1.2 to 12) V
(12 to 120) V
(120 to 700) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
0.024 % + 0.28 µV
0.016 % + 1.0 µV
0.024 % + 1.8 µV
0.078 % + 2.5 µV
0.39 % + 3.3 µV
3.2 % + 1.9 µV
0.0054 % + 3.7 µV
0.0054 % + 1.9 µV
0.011 % + 1.9 µV
0.024 % + 1.9 µV
0.062 % + 1.9 µV
0.24 % + 9.3 µV
0.78 % + 9.3 µV
1.2 % + 9.3 µV
0.0054 % + 37 µV
0.0054 % + 19 µV
0.011 % + 19 µV
0.024 % + 19 µV
0.062 % + 19 µV
0.24 % + 93 µV
0.78 % + 93 µV
1.2 % + 93 µV
0.0054 % + 370 µV
0.0054 % + 190 µV
0.011 % + 190 µV
0.024 % + 190 µV
0.062 % + 190 µV
0.24 % + 930 µV
0.78 % + 930 µV
1.2 % + 930 µV
0.016 % + 3.7 mV
0.016 % + 1.9 mV
0.016 % + 1.9 mV
0.028 % + 1.9 mV
0.093 % + 1.9 mV
0.32 % + 9.3 mV
1.2 % + 9.3 mV
0.031 % + 22 mV
0.031 % + 11 mV
0.047 % + 11 mV
0.093 % + 11 mV
0.24 % + 11 mV
Agilent 3458A,
option 002 | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2635.01) 07/08/2025 Page 8 of 21
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Current – Generate
(9 to 220) µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
Toroidal Clamps:
(10 to 16.4999) A
(16.5 to 149.999) A
(150 to 1025) A
(10 to 16.4999) A
(16.5 to 149.999) A
(150 to 1025) A
Other Clamps:
(10 to 16.4999) A
(16.5 to 149.999) A
(150 to 1025) A
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(20 to 1000) Hz
(1000 to 5000) Hz
(5 to 10) kHz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
0.024 % + 16 nA
0.016 % + 9.5 nA
0.011 % + 8.0 nA
0.028 % + 12 nA
0.11 % + 62 nA
0.024 % + 39 nA
0.016 % + 31 nA
0.011 % + 31 nA
0.019 % + 0.10 nA
0.11 % + 0.62 nA
0.024 % + 0.39 nA
0.016 % + 0.31 nA
0.011 % + 0.31 nA
0.019 % + 0.54 nA
0.11 % + 4.7 nA
0.024 % + 3.9 µA
0.016 % + 3.2 µA
0.011 % + 2.4 µA
0.019 % + 3.2 µA
0.11 % + 94 µA
0.025 % + 31 µA
0.039 % + 78 µA
0.63 % + 160 µA
0.22 % + 2.3 mA
0.22 % + 19 mA
0.22 % + 70 mA
0.61 % + 2.3 mA
0.61 % + 21 mA
0.61 % + 78 mA
0.43 % + 23 mA
0.43 % + 190 mA
0.43 % + 700 mA
Fluke 5720A
Fluke 5522A w/coil | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2635.01) 07/08/2025 Page 9 of 21
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Current – Measure
(0 to 200) µA
(0.2 to 2) mA
(2 to 20) mA
(20 to 200) mA
(0.2 to 2) A
(2 to 20) A
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
10 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
10 Hz to 2 kHz
(2 to 10) kHz
0.031 % + 0.06 µA
0.029 % + 0.06 µA
0.062 % + 0.06 µA
0.31 % + 0.06 µA
0.031 % + 0.61 µA
0.029 % + 0.61 µA
0.062 % + 0.61 µA
0.32 % + 0.61 µA
0.031 % + 6.1 µA
0.029 % + 6.1 µA
0.062 % + 6.1 µA
0.32 % + 6.1 µA
0.031 % + 61 µA
0.028 % + 61 µA
0.058 % + 61 µA
0.057 % + 610 µA
0.067 % + 610 µA
0.24 % + 610 µA
0.072 % + 58 µA
0.20 % + 58 µA
Fluke 8508A
AC Current – Measure
(20 to 120) µA
(0.12 to 1.2) mA
(1.2 to 12) mA
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 1 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5kHz
0.32 % + 0.03 µA
0.12 % + 0.03 µA
0.047 % + 0.03 µA
0.039 % + 0.03 µA
0.32 % + 0.19 µA
0.12 % + 0.19 µA
0.047 % + 0.19 µA
0.024 % + 0.19 µA
0.047 % + 0.19 µA
0.32 % + 0.37 µA
0.43 % + 1.4 µA
0.32 % + 1.9 µA
0.12 % + 1.9 µA
0.047 % + 1.9 µA
0.024 % + 1.9 µA
Agilent 3458A,
option 002 | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2635.01) 07/08/2025 Page 10 of 21
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Current– Measure
(cont)
(1.2 to 12) mA
(12 to 120) mA
(0.12 to 1.2) A
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
0.047 % + 1.9 µA
0.32 % + 3.7 µA
0.43 % + 14 µA
0.32 % + 19 µA
0.12 % + 47 µA
0.047 % + 37 µA
0.024 % + 28 µA
0.047 % + 19 µA
0.32 % + 37 µA
0.43 % + 140 µA
0.32 % + 190 µA
0.12 % + 190 µA
0.047 % + 190 µA
0.024 % + 190 µA
0.047 % + 190 µA
0.32 % + 370 µA
0.43 % + 1.4 mA
Agilent 3458A,
option 002
Parameter/Equipment
Range
CMC2, 4, 7 (±)
Comments
AC Power – Generate
33 mV to 1020 V
(45 to 65) Hz
PF=1
109 µW to 1 mW
(1 to 4) mW
(4 to 1) mW
(11 to 40) mW
(40 to 396) mW
396 mW to 11 W
(11 to 264) W
264 W to 3 kW
(3 to 11) kW
0.11 %
0.08 %
0.09 % + 0.06 nW
0.07 % + 0.06 nW
0.07 % + 0.58 nW
0.09 % + 5.8 nW
0.07 %
0.09 %
0.07 %
Fluke 5522A | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2635.01) 07/08/2025 Page 11 of 21
Parameter/Range3
Frequency
CMC2, 7 (±)
Comments
Capacitance – Generate
(220 to 399.9) nF
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.999) nF
(11 to 32.999) nF
(33 to 109.99) nF
(110 to 329.99) nF
(0.33 to 1.0999) µF
(1.1 to 3.2999) µF
(3.3 to 10.999) µF
(11 to 32.999) µF
(33 to 109.999) µF
(110 to 329.999) µF
(0.33 to 1.099 99) mF
(1.1 to 3.299 99) mF
(3.3 to 10.999) mF
(11 to 32.9999) mF
(33 to 110) mF
(10 Hz to 1kHz)
(0 to 600) Hz
(0 to 50) Hz
0.39 % + 7.8 pF
0.39 % + 7.8 pF
0.39 % + 7.8 pF
0.20 % + 7.8 pF
0.20 % + 0.08 nF
0.20 % + 0.08 nF
0.20 % + 0.23 nF
0.20 % + 0.78 nF
0.20 % + 2.3 nF
0.20 % + 7.8 nF
0.31 % + 0.02 µF
0.35 % + 0.08 µF
0.35 % + 0.23 µF
0.35 % + 0.78 µF
0.35 % + 0.23 µF
0.35 % + 0.78 µF
0.58 % + 0.23 µF
0.85 % + 0.78 µF
Fluke 5522A
Capacitance – Measure5
10 aF to 10 F
10 Hz to 2 MHz
0.05 % + 50 aF
QuadTech 7600+
Parameter/Equipment
Range3
CMC2, 4, 7 (±)
Comments
Capacitance –
Generate, Fixed Points
1000 pF
0.01 µF
0.1 µF
1.0 µF
50 pF to 0.1 µF
0.035 %
0.035 %
0.035 %
0.035 %
0.05 % + 5 pF
General Radio
1409-F
1409-L
1409-T
1409-Y
1412-BC
Inductance – Generate,
Fixed Points
100 µH
1 mH
10 mH
100 mH
1 H
10 H
0.3 %
0.15 %
0.15 %
0.15 %
0.15 %
0.15 %
General Radio,
1482-B
1482-E
1482-H
1482-L
1482-P
1482-T | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2635.01) 07/08/2025 Page 12 of 21
Parameter/Range3
Frequency
CMC2, 4, 7 (±)
Comments
Inductance – Measure5
1 pH to 100 H
10 Hz to 2 MHz
0.05 % + 0.5 pH
QuadTech 7600+
Oscilloscope –
Amplitude DC
50 Ω
1 MΩ
Amplitude Square Wave
50 Ω
1 MΩ
Leveled Sine Wave
Amplitude
(50 kHz Ref)
Flatness
(Ref to 50 kHz)
Time Marker
Rise Time – Generate
Rise Time – Generate
(0 to 6.6) V
(0 to 130) V
1 mV to 6.6 V(
p-p)
1 mV to 130 V(p-p)
50 kHz Reference
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
(600 to 1100) MHz
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
5 s to 50 ms
20 s to 2 ns
195.7 ps
88.3 ps
0.25 % + 40 µV
0.05 % + 40 µV
0.25 % + 40 µV
0.1 % + 40 µV
2 % + 300 µV
4 % + 300 µV
4 % + 300 µV
6 % + 300 µV
7 % + 300 µV
2 % + 100 µV
2 % + 100 µV
4 % + 100 µV
0.0025 % + 15 MHz
0.000 25 %
44 ps
15 ps
Fluke 5522A/SC1100
Agilent 81134A &
Fluke 910R | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2635.01) 07/08/2025 Page 13 of 21
II. Electrical – RF/Microwave
Parameter/Range
Frequency
CMC2, 4, 7 (±)
Comments
RF Power –Measure
(-10 to +20) dBm
50 Ω
(-10 to +20) dBm
50 Ω
(-10 to +20) dBm
50 Ω
0.1 MHz
(0.3 to 0.5) MHz
(1 to 3) MHz
5 MHz
(10 to 30) MHz
50 MHz
(100 to 1500) MHz
(2000 to 3000) MHz
4000 MHz
4200 MHz
50 MHz
100 MHz
(300 to 1000) MHz
1500 MHz
2000 MHz
(3000 to 6000) MHz
(7000 to 12 000) MHz
12 400 MHz
(13 000 to 15 000) MHz
(16 000 to 17 000) MHz
18 000 MHz
19 000 MHz
20 000 MHz
(21 000 to 22 000) MHz
(23 000 to 24 000) MHz
(25 000 to 26 000) MHz
26 500 MHz
50 MHz
100 MHz
(300 to 2000) MHz
3000 MHz
(4000 to 7000) MHz
(8000 to 12 000) MHz
(13 000 to 18 000) MHz
(19 000 to 20 000) MHz
(21 000 to 26 000) MHz
(27 000 to 29 000) MHz
30 000 MHz
31 000 MHz
32 000 MHz
33 000 MHz
(34 000 to 34 500) MHz
5.7 %
2.5 %
1.7 %
1.7 %
1.7 %
1.5 %
1.7 %
4.5 %
4.5 %
4.5 %
2.0 %
2.6 %
2.3 %
2.3 %
2.6 %
3.1 %
3.1 %
3.2 %
3.7 %
3.8 %
4.3 %
4.3 %
5.1 %
5.1 %
5.2 %
5.2 %
5.3 %
2.0 %
2.6 %
2.3 %
3.0 %
3.1 %
3.2 %
3.8 %
4.6 %
5.3 %
6.0 %
5.7 %
5.6 %
5.5 %
5.5 %
5.5 %
Agilent E4418B,
Agilent 8482A
Agilent E4418B,
Agilent 8485A
Agilent E4418B,
Agilent 8487A | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2635.01) 07/08/2025 Page 14 of 21
Parameter/Range
Frequency
CMC2, 4, 7 (±)
Comments
RF Power –Measure (cont)
(-10 to +20) dBm
50 Ω
-60 dBm
50 Ω
-50 dBm
50 Ω
(-40 to +20) dBm
50 Ω
(35 000 to 40 000) MHz
(41 000 to 50 000) MHz
50 MHz
(100 to 2000) MHz
(3000 to 500) MHz
(1500 to 1000) MHz
2000 MHz
(3000 to 7000) MHz
(8000 to 14 000) MHz
(15 000 to 17 000) MHz
18 000 MHz
(19 000 to 20 000) MHz
(21 000 to 22 000) MHz
(23 000 to 24 000) MHz
(25 000 to 26 000) MHz
26 500 MHz
50 MHz
(100 to 2000) MHz
(3000 to 7000) MHz
(8000 to 14 000) MHz
(15 000 to 17 000) MHz
(18 000 to 20 000) MHz
(21 000 to 22 000) MHz
(23 000 to 24 000) MHz
(25 000 to 26 000) MHz
26 500 MHz
50 MHz
(100 to 2000) MHz
(3000 to 7000) MHz
(8000 to 14 000) MHz
(15 000 to 17 000) MHz
18 000 MHz
(19 000 to 20 000) MHz
(21 000 to 22 000) MHz
23 000 MHz
(24 000 to 26 000) MHz
26 500 MHz
5.4 %
9.5 %
10 %
11 %
11 %
11 %
11 %
11 %
11 %
11 %
12 %
12 %
12 %
12 %
12 %
12 %
2.8 %
4.4 %
5.0 %
4.4 %
4.4 %
5.0 %
5.2 %
5.2 %
5.7 %
5.7 %
2.6 %
4.3 %
4.8 %
4.3 %
4.3 %
4.8 %
5.1 %
5.1 %
5.6 %
5.6 %
6.3 %
Agilent E4418B,
Agilent 8482A
Agilent E4418B,
Agilent E4413A
Agilent E4418B,
Agilent E4413A
Agilent E4418B,
Agilent E4413A | ||
| 15 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2635.01) 07/08/2025 Page 15 of 21
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
RF Power – Generate
(+13 to -56) dBm
(-20 to -10) dBm
(-10 to 0) dBm
(0 to +10) dBm
(0 to +10) dBm
> +10 dBm
1 Hz to 20 MHz
250 kHz to 2 GHz
(> 2 to 20) GHz
(> 20 to 40) GHz
250 kHz to 2 GHz
(> 2 to 20) GHz
(> 20 to 50) GHz
250 kHz to 2 GHz
(> 2 to 20) GHz
(> 20 to 40) GHz
(> 40 to 50) GHz
250 kHz to 40 GHz
0.52 dB
1.4 dBm
1.2 dBm
1.3 dBm
0.6 dBm
0.8 dBm
0.9 dBm
0.6 dBm
0.8 dBm
0.9 dBm
1.3 dBm
0.6 dBm
HP 3325B
Agilent E8257D
RF Attenuation –
Generate
(0 to 12) dB
(0 to 120) dB
(0 to 90) dB
(90 to 120) dB
(0 to 2) dB
(> 2 to 6) dB
(> 6 to 10) dB
(> 10 to 11) dB
10 dB
20 dB
30 dB
40 dB
50 dB
60 dB
70 dB
80 dB
90 dB
100 dB
110 dB
DC to 1 kHz
1 kHz to 500 MHz
500 MHz to 1 GHz
DC to 1 kHz
1 kHz to 1 GHz
1 kHz to 1 GHz
DC to 4 GHz
DC to 4 GHz
DC to 4 GHz
DC to 4 GHz
DC to 4 GHz
DC to 4 GHz
DC to 4 GHz
DC to 4 GHz
DC to 4 GHz
DC to 4 GHz
DC to 4 GHz
DC to 4 GHz
DC to 4 GHz
DC to 4 GHz
DC to 4 GHz
0.06 dB
0.14 dB
0.20 dB
0.17 dB
0.87 dB
1.7 dB
0.12 dB
0.17 dB
0.23 dB
0.29 dB
0.12 dB
0.23 dB
0.29 dB
0.4 dB
0.46 dB
0.58 dB
0.69 dB
0.75 dB
0.87 dB
0.92 dB
1.0 dB
HP 355C, 1 dB
steps
HP 355D, 10 dB
steps
HP 8494A, 1 dB
steps
HP 8496A, 10 dB
steps | 0 to 120 dB |
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2635.01) 07/08/2025 Page 16 of 21
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
RF Attenuation –
Generate (cont)
Fixed Values
1 dB
3 dB
6 dB
10 dB
20 dB
30 dB
DC to 18 GHz
0.3 dB
0.3 dB
0.3 dB
0.5 dB
0.5 dB
1.0 dB
Weinschel AS-18
Noise Source –
Generate & Measure,
Excess Noise Ratio
(ENR)
(12 to 17) dB
(12 to 17) dB
Excess Noise Ratio
(ENR)
10.00 MHz
100.00 MHz
1000.00 MHz
2000.00 MHz
3000.00 MHz
4000.00 MHz
5000.00 MHz
6000.00 MHz
7000.00 MHz
8000.00 MHz
9000.00 MHz
10 000.00 MHz
11 000.00 MHz
12 000.00 MHz
13 000.00 MHz
14 000.00 MHz
15 000.00 MHz
16 000.00 MHz
17 000.00 MHz
18 000.00 MHz
19 000.00 MHz
20 000.00 MHz
21 000.00 MHz
22 000.00 MHz
23 000.00 MHz
24 000.00 MHz
25 000.00 MHz
26 000.00 MHz
26 500.00 MHz
0.14 dB
0.22 dB
0.21 dB
0.20 dB
0.20 dB
0.19 dB
0.21 dB
0.20 dB
0.22 dB
0.23 dB
0.26 dB
0.26 dB
0.29 dB
0.32 dB
0.31 dB
0.28 dB
0.29 dB
0.30 dB
0.30 dB
0.27 dB
0.28 dB
0.28 dB
0.30 dB
0.30 dB
0.32 dB
0.32 dB
0.30 dB
0.31 dB
0.35 dB
Agilent N4002A
noise source,
w/N8975A noise
figure meter
Agilent N4002A
noise source,
w/N8975A noise
figure meter | ||
| 17 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2635.01) 07/08/2025 Page 17 of 21
Parameter/Range
Frequency
CMC2, 4, 7 (±)
Comments
Phase Modulation –
Measure
3 Hz to 50GHz
150 kHz to 1300 MHz.
10 M to 1.3 GHz
3 Hz to 67 GHz
150 kHz to 1300 MHz
(1.3 to 26.5) GHz
0.8 %
4 % + 1 digit
3 % + 1digit
Agilent PSA E4448A
HP 8901B
Amplitude Modulation –
Measure
3 Hz to 50 GHz
150 kHz to 10 MHz.
10 M to 1.3 GHz
200 Hz to 20 kHz
50 Hz to 10 kHz (5-99)%
20 Hz to 100 kHz (0-99)%
50 Hz to 50 kHz (5-99)%
20 Hz to 100 kHz (0 – 99) %
0.8 % .
2 % + 1digit
3 % + 1 digit
1 % + 1 digit
3 % + 1 digit
Agilent PSA E4448A
HP 8901B
Frequency Modulation –
Measure
3 Hz to 50 GHz
250 kHz to 10 MHz.
10 to 1.3 GHz
10 to 1.3 GHz
200 Hz to 20 kHz
20 Hz to 10 kHz
50 Hz to 100 kHz
20 Hz to 200 kHz
0.8 %
2 % + 1digit
1 % + 1digit
5 % + 1digit
Agilent PSA E4448A
HP 8901B
Pulse Modulation –
Measure
DC to 2.25GHz
Level ON/OFF Ratio
10 ns to 500 ms
Pulse width
70 parts in 10
6 +
0.01 %
Agilent 54846A
Agilent PSA E4448A
Thermocouple –
Electrical Simulation
Measuring Equipment &
Measure
Type B
Type C
(600 to 800) °C
(800 to 1000) °C
(100 to 1550) °C
(1550 to 1820) °C
(0 to 150) °C
(150 to 650) °C
(650 to 1000) °C
(1000 to 1800) °C
(1800 to 2316) °C
0.34 °C
0.26 °C
0.23 °C
0.26 °C
0.23 °C
0.20 °C
0.24 °C
0.39 °C
0.65 °C
Fluke 5522A/525A | ||
| 18 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2635.01) 07/08/2025 Page 18 of 21
Parameter/Equipment
Range3
CMC2 (±)
Comments
Thermocouple – Electrical
Simulation Measuring
Equipment & Measure (cont)
Type E
Type J
Type K
Type L
Type N
Type R
Type S
Type T
Type U
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-200 to -100) °C
(-100 to 800) °C
(800 to 900) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 410) °C
(410 to 1300) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
(0 to 250) °C
(250 to 1000) °C
(1000 to 1400) °C
(1400 to 1767) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
(-200 to 0) °C
(0 to 600) °C
0.39 °C
0.12 °C
0.11 °C
0.12 °C
0.16 °C
0.21 °C
0.12 °C
0.11 °C
0.13 °C
0.18 °C
0.26 °C
0.14 °C
0.12 °C
0.20 °C
0.31 °C
0.29 °C
0.20 °C
0.13 °C
0.31 °C
0.17 °C
0.15 °C
0.14 °C
0.21 °C
0.44 °C
0.27 °C
0.26 °C
0.31 °C
0.36 °C
0.28 °C
0.29 °C
0.36 °C
0.49 °C
0.19 °C
0.12 °C
0.11 °C
0.43 °C
0.21 °C
Fluke 5522A/525A | ||
| 19 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2635.01) 07/08/2025 Page 19 of 21
Parameter/Equipment
Range
CMC2 (±)
Comments
RTD –
Electrical Simulation
Measuring Equipment &
Measure
Pt 385, 100 Ω
Pt 3926, 100 Ω
Pt 3916, 100 Ω
Pt 385, 200 Ω
Pt 385, 500 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-200 to -190) °C
(-190 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
0.04 °C
0.04 °C
0.05 °C
0.07 °C
0.08 °C
0.09 °C
0.18 °C
0.04 °C
0.04 °C
0.05 °C
0.07 °C
0.08 °C
0.09 °C
0.19 °C
0.03 °C
0.04 °C
0.05 °C
0.05 °C
0.06 °C
0.07 °C
0.08 °C
0.18 °C
0.03 °C
0.03 °C
0.03 °C
0.04 °C
0.09 °C
0.10 °C
0.11 °C
0.12 °C
0.03 °C
0.04 °C
0.04 °C
0.05 °C
0.06 °C
0.06 °C
0.07 °C
0.09 °C
Fluke 5522A/525A | ||
| 20 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2635.01) 07/08/2025 Page 20 of 21
Parameter/Equipment
Range
CMC2 (±)
Comments
RTD – Measuring
Electrical Simulation
Equipment & Measure
(cont)
Pt 385, 1000 Ω
PtNi 385, 120 Ω
Cu 427, 10 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(-100 to 26) °C
0.02 °C
0.02 °C
0.03 °C
0.04 °C
0.05 °C
0.05 °C
0.05 °C
0.18 °C
0.06 °C
0.06 °C
0.11 °C
0.23 °C
Fluke 5522A/525A
III. Time & Frequency
Parameter/Equipment
Range
CMC2, 8 (±)
Comments
Time Interval
1 s to 24 h
0.5 s
HP 5345A
Frequency –
Measuring Equipment
5.0 MHz
10 MHz
Up to to 20 MHz
(0.01 to 50) GHz
2 x 10
-12 Hz
2 x 10-12 Hz
5 ps
5 ps
Fluke 910R/ NIST
76100S frequency
measurement analysis
system
HP 3325B
HP 83650B
Frequency –Measure
5.0 MHz
10 MHz
DC to 40 GHz
0.2 pHz/Hz
0.2 pHz/Hz
5 ps
Fluke 910R/ NIST
76100S frequency
measurement analysis
system
HP 5345A
___________________________________________ | ||
| 21 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2635.01) 07/08/2025 Page 21 of 21
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Where ranges are not specified, the CMC stated is for the cardinal points only.
4 All percentages are percent of reading unless otherwise indicated.
5 The CMC is stated for 1 kHz and may vary with voltage and frequency.
6 This scope meets A2LA’s P112 Flexible Scope Policy.
7 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMC’s are expressed as eit her a specific value that covers the full range or as a
percentage or fraction of the reading plus a fixed floor specification.
8 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 22 | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025; ANSI/NCSL Z540-1-1994 and R205 | AIR; ELECTRONIC | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Trescal, Inc. - Long Island, NYBohemia, NY · ~9 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- AALFA - KAL Metrology Laboratory, division of AALBORG Instruments & ControlsOrangeburg, NY · ~73 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- CONNECTICUT CALIBRATION TECHNOLOGIES, INC., dba CONNECTICUT CALIBRATIONNewtown, CT · ~76 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Atlantic Scale CompanyNutley, NJ · ~79 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Instru-Met CorporationUnion, NJ · ~92 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.