Atlantic Scale Company
136 Washington Avenue, 07110, Nutley, NJ, United States
Visit website- Scope lines
- 19
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 19 scope lines.
A2LA certificate 2736.01 · 19 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
| 2 | - | Gage Blocks; Cylindrical Gages – Pins, Plugs & Discs; Ring GagesShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2736.01) Revised 12/17/2025 Page 2 of 18
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Gage Blocks
(0.01 to 1) in
(> 1 to 4) in
(> 4 to 8) in
(> 8 to 12) in
(4.0 + 4.0L) µin
(1.4 + 5.9L) µin
(6.4 + 5.2L) µin
(18 + 4.6L) µin
P&W Lab MasterTM
master gage blocks
Cylindrical Gages – Pins,
Plugs & Discs
(0.01 to 1) in
(> 1 to 4) in
(> 4 to 8) in
(> 8 to 12) in
(3.8 + 4.1L) µin
(1.6 + 5.9L) µin
(6.5 + 5.2L) µin
(18 + 4.6L) µin
P&W Lab MasterTM
master gage blocks
Ring Gages
Up to 1 in
(> 1 to 4) in
(8.0 + 2.6L) µin
(4.1 + 5.4L) µin
P&W Lab MasterTM
master ring gages
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
DC Voltage – Generate
(0 to 329.9999) mV
330 mV to 3.299 999 V
(3.3 to 32.999 99) V
(33 to 329.9999) V
(330 to 1000) V
11 µV/V + 1.6 µV
5.4 µV/V + 10 µV
6.3 µV/V + 88 µV
10 µV/V + 770 µV
0.011 mV/V + 2.1 mV
Fluke 5522A
DC Voltage – Measure
(0 to 199.99) mV
200 mV to 1.9999 V
(2 to 19.999) V
(20 to 199.99) V
(200 to 1000) V
5.0 µV/V + 0.31 µV
1.8 µV/V + 6.9 µV
3.5 µV/V + 7.2 µV
5.5 µV/V + 53 µV
5.4 µV/V + 660 µV
Fluke 8508A
DC Current – Generate
(0 to 329.999) µA
330 µA to 3.299 99 mA
(3.3 to 32.9999) mA
(33 to 329.999) mA
330 mA to 1.099 99 A
(1.1 to 2.999 99) A
(3 to 10.9999) A
(11 to 20) A
99 μA/A + 0.014 μA
64 μA /A + 0.042 μA
64 μA/A + 0.29 μA
57 μA/A + 5.8 μA
130 μA/A + 32 μA
240 μA/A + 100 μA
320 μA/A + 520 μA
660 μA/A + 820 μA
Fluke 5522A | See scope document |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2736.01) Revised 12/17/2025 Page 3 of 18
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
DC Current – Measure
(0 to 199.99) µA
200 µA to 1.9999 mA
(2 to 19.999) mA
(20 to 199.99) mA
200 mA to 1.9999 A
(2 to 20) A
11 μA/A + 0.8 nA
12 μA/A + 6.3 nA
14 μA/A + 63 nA
49 μA/A + 0.9 μA
180 μA/A + 18 μA
410 μA/A + 450 μA
Fluke 8508A
Resistance – Generate
Fixed Points
(0 to 10.9999) Ω
(11 to 32.9999) Ω
(33 to 109.9999) Ω
(110 to 329.9999) Ω
330 Ω to 1.099 999 kΩ
(1.1 to 3.299 999) kΩ
(3.3 to 10.999 99) kΩ
(11 to 32.999 99) kΩ
(33 to 109.9999) kΩ
(110 to 329.9999) kΩ
330 kΩ to 1.099 999 MΩ
(1.1 to 3.299 999) MΩ
(3.3 to 10.999 99) MΩ
(11 to 32.999 99) MΩ
(33 to 109.9999) MΩ
(110 to 329.999) MΩ
(330 to 1100) MΩ
14 Ω
25 Ω
62.5 Ω
100 Ω
200 Ω
250 Ω
350 Ω
400 Ω
500 Ω
4 kΩ
10 kΩ
20 kΩ
40 kΩ
100 kΩ
107 kΩ
300 kΩ
400 kΩ
500 kΩ
27 μΩ/Ω + 0.0067 Ω
20 μΩ/Ω + 0.010 Ω
19 μΩ/Ω + 0.010 Ω
19 μΩ/Ω + 0.013 Ω
18 μΩ/Ω + 0.014 Ω
18 μΩ/Ω + 0.14 Ω
17 μΩ/Ω + 0.094 Ω
18 μΩ/Ω + 0.74 Ω
17 μΩ/Ω + 0.96 Ω
21 μΩ/Ω + 7.0 Ω
20 μΩ/Ω + 8.5 Ω
39 Ω/MΩ + 110 Ω
83 Ω/MΩ + 220 Ω
150 Ω/MΩ + 0.0025 MΩ
310 Ω/MΩ + 0.0058 MΩ
2.0 kΩ/MΩ + 0.086 MΩ
9.8 kΩ/MΩ + 0.63 MΩ
0.69 µΩ
0.67 µΩ
0.56 µΩ
0.55 µΩ
0.68 µΩ
0.69 µΩ
0.61 µΩ
0.61 µΩ
0.6 µΩ
0.65 µΩ
0.67 µΩ
0.75 µΩ
0.59 µΩ
0.46 µΩ
0.47 µΩ
0.73 µΩ
1 µΩ
0.65 µΩ
Fluke 5522A
Isotech RB802-18,
Fluke 5522A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2736.01) Revised 12/17/2025 Page 4 of 18
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Resistance – Measure
(0 to 1.9999) Ω
(2 to 19.999) Ω
(20 to 199.99) Ω
200 Ω to 1.9999 kΩ
(2 to 19.999) kΩ
(20 to 199.99) kΩ
200 kΩ to 1.9999 MΩ
(2 to 19.999) MΩ
(20 to 199.99) ΩM
200 MΩ to 2 GΩ
13 μΩ/Ω + 19 μΩ
9.1 μΩ/Ω + 30 μΩ
8.2 μΩ/Ω + 88 μΩ
8.0 mΩ/kΩ + 0.87 mΩ
8.0 mΩ/kΩ + 6.8 mΩ
8.3 mΩ/kΩ + 61 mΩ
9.9 Ω/MΩ + 1.1 Ω
23 Ω/MΩ + 97 Ω
130 Ω/MΩ + 0.010 MΩ
1.5 MΩ/GΩ + 1.0 MΩ
Fluke 8508A
Capacitance – Generate
(0.22 to 0.3999) nF
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.9999) nF
(11 to 32.9999) nF
(33 to 109.999) nF
(110 to 329.999) nF
330 nF to 1.099 99 µF
(1.1 to 3.299 99) µF
(3.3 to 10.9999) µF
(11 to 32.9999) µF
(33 to 109.999) µF
(110 to 329.999) µF
330 µF to 1.099 99 mF
(1.1 to 3.2999) mF
(3.3 to 10.9999) mF
(11 to 32.9999) mF
(33 to 110) mF
25 % + 0.01 nF
22 % + 0.01 nF
21 % + 0.01 nF
0.3 % + 0.01 nF
0.35 % + 0.1 nF
0.3 % + 0.1 nF
0.3 % + 0.3 nF
0.3 % + 1 nF
0.3 % + 3 nF
0.3 % + 10 nF
0.47 % + 30 nF
0.53 % + 100 nF
0.53 % + 300 nF
0.53 % + 1 µF
0.52 % + 3 µF
0.52 % + 10 µF
0.87 % + 30 µF
1.3 % + 100 µF
Fluke 5522A | ||
| 5 | - | thermocouple indicating devicesShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2736.01) Revised 12/17/2025 Page 5 of 18
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Simulation of
Thermocouple Indicating
Devices –
Type B
Type C
Type E
Type J
Type K
Type L
Type N
Type R
(600 to 800) °C
(800 to 1000) °C
(1000 to 1550) °C
(1550 to 1820) °C
(0 to 150) °C
(150 to 650) °C
(650 to 1000) °C
(1000 to 1800) °C
(1800 to 2316) °C
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-200 to -100) °C
(-100 to 800) °C
(800 to 900) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 410) °C
(410 to 1300) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
0.59 °C
0.49 °C
0.45 °C
0.48 °C
0.43 °C
0.4 °C
0.44 °C
0.63 °C
1.0 °C
0.62 °C
0.3 °C
0.28 °C
0.3 °C
0.45 °C
0.33 °C
0.22 °C
0.2 °C
0.23 °C
0.29 °C
0.4 °C
0.24 °C
0.22 °C
0.32 °C
0.48 °C
0.43 °C
0.31 °C
0.21 °C
0.55 °C
0.39 °C
0.36 °C
0.36 °C
0.43 °C
0.67 °C
0.42 °C
0.47 °C
0.48 °C
Fluke 5522A | See scope document |
| 6 | - | thermocouple indicating devices; RTD indicating devicesShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2736.01) Revised 12/17/2025 Page 6 of 18
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Simulation of
Thermocouple Indicating
Devices –
(cont)
Type S
Type T
Type U
(0 to 250) °C
(250 to 1000) °C
(1000 to 1400) °C
(1400 to 1767) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
(-200 to 0) °C
(0 to 600) °C
0.64 °C
0.54 °C
0.55 °C
0.64 °C
0.81 °C
0.44 °C
0.39 °C
0.38 °C
0.65 °C
0.32 °C
Fluke 5522A
Electrical Simulation of
RTD Indicating Devices –
Pt 385, 100 Ω
Pt 3926, 100 Ω
Pt 3916, 100 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-200 to -190) °C
(-190 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
0.06 °C
0.06 °C
0.09 °C
0.11 °C
0.12 °C
0.14 °C
0.27 °C
0.06 °C
0.06 °C
0.09 °C
0.11 °C
0.12 °C
0.14 °C
0.29 °C
0.05 °C
0.06 °C
0.07 °C
0.09 °C
0.09 °C
0.11 °C
0.12 °C
0.27 °C
Fluke 5522A | See scope document |
| 7 | - | RTD Indicating DevicesShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2736.01) Revised 12/17/2025 Page 7 of 18
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Simulation of
RTD Indicating
Devices –
(cont)
Pt 385, 200 Ω
Pt 385, 500 Ω
Pt 385, 1000 Ω
PtNi 385, 120 Ω
(Ni120)
Cu 427, 10 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260 °C
(-100 to 260) °C
0.05 °C
0.05 °C
0.05 °C
0.06 °C
0.14 °C
0.15 °C
0.16 °C
0.19 °C
0.05 °C
0.06 °C
0.06 °C
0.07 °C
0.09 °C
0.09 °C
0.1 °C
0.14 °C
0.05 °C
0.05 °C
0.06 °C
0.07 °C
0.07 °C
0.1 °C
0.1 °C
0.27 °C
0.1 °C
0.1 °C
0.17 °C
0.35 °C
Fluke 5522A | See scope document |
| 8 | - | AC VoltageShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2736.01) Revised 12/17/2025 Page 8 of 18
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage – Generate
(1 to 32.999) mV
(33 to 329.999) mV
330 mV to 3.299 99 V
(3.3 to 32.9999) V
(33 to 329.999) V
(330 to 1020) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
450 μV/V + 8.0 μV
86 μV/V + 5.2 μV
120 μV/V + 5.3 μV
610 μV/V + 6.2 μV
2.2 mV/V + 0.012 mV
4.8 mV/V + 0.055 mV
0.18 mV/V + 0.012 mV
0.078 mV/V + 0.014 mV
0.087 mV/V + 0.015 mV
0.21 mV/V + 0.016 mV
0.52 mV/V + 0.028 mV
1.3 mV/V + 0.078 mV
0.19 mV/V + 0.055 mV
0.091 mV/V + 0.080 mV
0.12 mV/V + 0.074 mV
0.18 mV/V + 0.095 mV
0.45 mV/V + 0.16 mV
1.5 mV/V + 0.82 mV
0.19 mV/V + 0.69 mV
0.09 mV/V + 0.82 mV
0.15 mV/V + 0.76 mV
0.21 mV/V + 1.2 mV
0.57 mV/V + 2.2 mV
0.11 mV/V + 8.8 mV
0.12 mV/V + 10 mV
0.15 mV/V + 9.5 mV
0.15 mV/V + 28 mV
1.3 mV/V + 65 mV
0.19 mV/V + 15 mV
0.16 mV/V + 17 mV
0.18 mV/V + 31 mV
Fluke 5522A | See scope document |
| 9 | - | AC VoltageShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2736.01) Revised 12/17/2025 Page 9 of 18
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage – Measure
(0 to 199.99) mV
200 mV to 1.9999 V
(2 to 19.999) V
(20 to 199.99) V
(200 to 1000) V
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
(1 to 10) Hz
(10 to 40) Hz
40 Hz to 10 kHz
160 μV/V + 18 μV
150 μV/V + 5.3 μV
110 μV/V + 5.4 μV
110 μV/V + 2.9 μV
140 μV/V + 4.7 μV
340 μV/V + 9.2 μV
770 μV/V + 21 μV
130 μV/V + 210 μV
120 μV/V + 23 μV
98 μV/V + 22 μV
77 μV/V + 22 μV
110 μV/V + 22 μV
230 μV/V + 41 μV
580 μV/V + 200 μV
3.0 mV/V + 2.0 mV
10 mV/V + 20 mV
0.14 mV/V + 1.6 mV
0.12 mV/V + 0.22 mV
0.094 mV/V + 0.21 mV
0.078 mV/V + 0.20 mV
0.11 mV/V + 0.21 mV
0.22 mV/V + 0.40 mV
0.58 mV/V + 2.0 mV
3.0 mV/V + 20 mV
10 mV/V + 200 mV
0.15 mV/V + 13 mV
0.12 mV/V + 2.2 mV
0.096 mV/V + 2.3 mV
0.081 mV/V + 2.4 mV
0.11 mV/V + 2.2 mV
0.22 mV/V + 4.3 mV
0.58 mV/V + 20 mV
3.0 mV/V + 200 mV
0.15 mV/V + 70 mV
0.12 mV/V + 20 mV
0.16 mV/V + 17 mV
Fluke 8508A | See scope document |
| 10 | - | AC CurrentShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2736.01) Revised 12/17/2025 Page 10 of 18
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Current – Generate
(29.00 to 329.99) µA
330 µA to 3.2999 mA
(3.3 to 32.999) mA
(33 to 329.99) mA
(0.33 to 1.099 99) A
(1.1 to 2.999 99) A
(3 to 10.9999) A
(11 to 20.5) A
(20 to 1000) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
(45 to 65) Hz
(65 to 440) Hz
1.1 μA/mA + 0.19 μA
0.74 μA/mA + 0.20 μA
0.59 μA/mA + 0.20 μA
1.8 μA/mA + 0.20 μA
4.9 μA/mA + 0.33 μA
7.5 μA/mA + 1.8 μA
1.1 μA/mA + 1.3 μA
0.57 μA/mA + 1.3 μA
0.41 μA/mA + 1.4 μA
1.1 μA/mA + 1.2 μA
3.1 μA/mA + 1.0 μA
6.5 μA/mA + 1.0 μA
0.92 μA/mA + 13 μA
0.36 μA/mA + 14 μA
0.10 μA/mA + 15 μA
0.30 μA/mA + 14 μA
1.1 μA/mA + 12 μA
2.5 μA/mA + 11 μA
0.89 mA/A + 0.15 mA
0.34 mA/A + 0.15 mA
0.092 mA/A + 0.16 mA
0.44 mA/A + 0.16 mA
1.1 mA/A + 0.16 mA
2.5 mA/A + 0.19 mA
1.0 mA/A + 0.35 mA
0.27 mA/A + 0.19 mA
4.0 mA/A + 0.69 mA
17 mA/A + 3.4 mA
1.2 mA/A + 0.21 mA
0.39 mA/A + 0.10 mA
4.0 mA/A + 0.69 mA
17 mA/A + 3.4 mA
0.18 mA/A + 7.7 mA
0.39 mA/A + 7.4 mA
20 mA/A + 3.0 mA
0.45 mA/A + 21 mA
0.63 mA/A + 20 mA
20 mA/A + 7.1 mA
0.93 % + 100 mA
0.37 % + 90 mA
Fluke 5522A
Fluke 5522A, with
Fluke 50-turn coil | 10 to 1000 A |
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2736.01) Revised 12/17/2025 Page 11 of 18
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Current – Measure
(0 to 220) µA
200 µA to 2 mA
(2 to 20) mA
(20 to 200) mA
200 mA to 2 A
(2 to 20) A
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
1 Hz to 10 kHz
(10 to 30) kHz
10 Hz to 2 kHz
(2 to 10) kHz
10 Hz to 2 kHz
(2 to 10) kHz
0.04 % + 20 nA
0.04 % + 20 nA
0.09 % + 50 nA
0.04 % + 0.2 µA
0.04 % + 0.2 µA
0.09 % + 2 µA
0.04 % + 2 µA
0.04 % + 2 µA
0.09 % + 2 µA
0.04 % + 20 µA
0.08 % + 20 µA
0.08 % + 200 µA
0.1 % + 200 µA
0.11 % + 2 mA
0.3 % + 2 mA
Fluke 8508A
III. Fluid Quantities
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Mass Flow Rate – Flow
Meter & Flow
Controller
(5 to 500) sccm
(> 500 to 5000) sccm
(> 5000 to 50 000) sccm
0.21 % + 0.10 sccm
0.20 % + 1.6 sccm
0.21 % + 7.6 sccm
Bios Drycal bench | ||
| 12 | NIST handbook 44 | Laboratory Balances | See scope document |
| 13 | NIST handbook 44; NIST Handbook 44 | - | 300 to 4000 kg |
| 14 | NIST Handbook 44; NISTIR 6969 SOP 5; NISTIR 6969 SOP 4; NISTIR 6969 SOP 7 | weights | See scope document |
| 15 | NISTIR 6969 SOP 5; NISTIR 6969 SOP 4; NISTIR 6969 SOP 7 | - | See scope document |
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2736.01) Revised 12/17/2025 Page 16 of 18
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Volume – Pipettes3
(0.1 to 1) µL
(2 to 5) µL
(6 to 20) µL
(1 to 5) µL
(6 to 10) µL
(11 to 20) µL
(10 to 40) µL
(41 to 100) µL
(101 to 200) µL
(201 to 500) µL
(501 to 1000) µL
(1001 to 2500) µL
(2501 to 5000) µL
(5001 to 10 000) µL
(10 000 to 50 000) µL
4.1 %
1.4 %
1.7 %
0.07 µL
0.08 µL
0.12 µL
0.23 µL
0.18 µL
0.3 µL
0.91 µL
1.5 µL
5.8 µL
6.4 µL
5.5 µL
29 µL
Photometric methods
Gravimetric methods,
6-digit balances
Gravimetric methods,
5-digit balances
V. Thermodynamics
Parameter/Equipment
Range
CMC2, 8 (±)
Comments
Relative Humidity –
Measuring Equipment3
10 % RH
20 % RH
50 % RH
80 % RH
95 % RH
0.51 % RH
0.51 % RH
0.53 % RH
0.51 % RH
0.53 % RH
Thunder Scientific
2500ST-LT
Temperature –
Thermometers & Probes3
(-80 to -30) °C
(-30 to 300) °C
(300 to 660) °C
(660 to 1200) °C
0.016 °C (16 mK)
0.011 °C (11 mK)
0.062 °C (62 mK)
1.6 °C
Comparison in liquid
bath with SPRT
Comparison in liquid &
metal block bath with
SPRT
SPRT with dry block
TC with dry block | ||
| 17 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2736.01) Revised 12/17/2025 Page 17 of 18
Parameter/Equipment
Range
CMC2 (±)
Comments
Temperature –
Thermometers & Probes
Fixed Points
-195.798 °C
-38.8344 °C
0.01 °C
29.7646 °C
156.598 °C
231.928 °C
419.527 °C
660.323 °C
0.0037 °C (3.7 mK)
0.0023 °C (2.3 mK)
0.0018 °C (1.8 mK)
0.0031 °C (3.1 mK)
0.0032 °C (3.2 mK)
0.0031 °C (3.1 mK)
0.0047 °C (4.7 mK)
0.0079 °C (7.9 mK)
Liquid N
2 comparison
Mercury cell
Water triple point cell
Gallium cell
Indium cell
Tin cell
Zinc cell
Aluminum cell
VI. Time & Frequency
Parameter/Equipment
Range
CMC2, 8 (±)
Comments
Frequency – Measure
10 MHz
5.8 × 10-10 Hz/Hz
Spectracom GPS
master oscillator
Frequency – Measuring
Equipment
0.01 Hz to 2 MHz
1.2 × 10-11 Hz/Hz + 5
µHz
Fluke 5522A w/ext 10
MHz reference
Stopwatch
(0 to 86 400) s/day
0.059 s/day
Vibrograf timometer
____________________________________________
1
This laboratory offers commercial calibration service and field calibration service, where noted.
2 Calibration and Measurement Capability (CMC) is the smallest uncertainty of measurement that a
laboratory can achieve within its scope of accreditation when performing more or less routine calibrations
of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded
uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of
k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be
greater than the CMC due to the be havior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC. | ||
| 18 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2736.01) Revised 12/17/2025 Page 18 of 18
4 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated.
5 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a
fraction/percentage of the reading plus a fixed floor specification.
6 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches.
7 This Scope meets A2LA’s P112 Flexible Scope Policy.
8 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 19 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in United States
- Instru-Met CorporationUnion, NJ · ~21 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Newark, NJBoonton, NJ · ~24 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- AALFA - KAL Metrology Laboratory, division of AALBORG Instruments & ControlsOrangeburg, NY · ~29 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- AH Electronic Test Equipment Repair CenterIslip, NY · ~79 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Long Island, NYBohemia, NY · ~86 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.