Atlantic Scale Company

136 Washington Avenue, 07110, Nutley, NJ, United States

Visit website
A2LA 2736.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
19
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 19 scope lines.

A2LA certificate 2736.01 · 19 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--
2-Gage Blocks; Cylindrical Gages – Pins, Plugs & Discs; Ring Gages
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2736.01) Revised 12/17/2025 Page 2 of 18 Parameter/Equipment Range CMC2, 6 (±) Comments Gage Blocks (0.01 to 1) in (> 1 to 4) in (> 4 to 8) in (> 8 to 12) in (4.0 + 4.0L) µin (1.4 + 5.9L) µin (6.4 + 5.2L) µin (18 + 4.6L) µin P&W Lab MasterTM master gage blocks Cylindrical Gages – Pins, Plugs & Discs (0.01 to 1) in (> 1 to 4) in (> 4 to 8) in (> 8 to 12) in (3.8 + 4.1L) µin (1.6 + 5.9L) µin (6.5 + 5.2L) µin (18 + 4.6L) µin P&W Lab MasterTM master gage blocks Ring Gages Up to 1 in (> 1 to 4) in (8.0 + 2.6L) µin (4.1 + 5.4L) µin P&W Lab MasterTM master ring gages II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 5 (±) Comments DC Voltage – Generate (0 to 329.9999) mV 330 mV to 3.299 999 V (3.3 to 32.999 99) V (33 to 329.9999) V (330 to 1000) V 11 µV/V + 1.6 µV 5.4 µV/V + 10 µV 6.3 µV/V + 88 µV 10 µV/V + 770 µV 0.011 mV/V + 2.1 mV Fluke 5522A DC Voltage – Measure (0 to 199.99) mV 200 mV to 1.9999 V (2 to 19.999) V (20 to 199.99) V (200 to 1000) V 5.0 µV/V + 0.31 µV 1.8 µV/V + 6.9 µV 3.5 µV/V + 7.2 µV 5.5 µV/V + 53 µV 5.4 µV/V + 660 µV Fluke 8508A DC Current – Generate (0 to 329.999) µA 330 µA to 3.299 99 mA (3.3 to 32.9999) mA (33 to 329.999) mA 330 mA to 1.099 99 A (1.1 to 2.999 99) A (3 to 10.9999) A (11 to 20) A 99 μA/A + 0.014 μA 64 μA /A + 0.042 μA 64 μA/A + 0.29 μA 57 μA/A + 5.8 μA 130 μA/A + 32 μA 240 μA/A + 100 μA 320 μA/A + 520 μA 660 μA/A + 820 μA Fluke 5522A
See scope document
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2736.01) Revised 12/17/2025 Page 3 of 18 Parameter/Equipment Range CMC2, 5 (±) Comments DC Current – Measure (0 to 199.99) µA 200 µA to 1.9999 mA (2 to 19.999) mA (20 to 199.99) mA 200 mA to 1.9999 A (2 to 20) A 11 μA/A + 0.8 nA 12 μA/A + 6.3 nA 14 μA/A + 63 nA 49 μA/A + 0.9 μA 180 μA/A + 18 μA 410 μA/A + 450 μA Fluke 8508A Resistance – Generate Fixed Points (0 to 10.9999) Ω (11 to 32.9999) Ω (33 to 109.9999) Ω (110 to 329.9999) Ω 330 Ω to 1.099 999 kΩ (1.1 to 3.299 999) kΩ (3.3 to 10.999 99) kΩ (11 to 32.999 99) kΩ (33 to 109.9999) kΩ (110 to 329.9999) kΩ 330 kΩ to 1.099 999 MΩ (1.1 to 3.299 999) MΩ (3.3 to 10.999 99) MΩ (11 to 32.999 99) MΩ (33 to 109.9999) MΩ (110 to 329.999) MΩ (330 to 1100) MΩ 14 Ω 25 Ω 62.5 Ω 100 Ω 200 Ω 250 Ω 350 Ω 400 Ω 500 Ω 4 kΩ 10 kΩ 20 kΩ 40 kΩ 100 kΩ 107 kΩ 300 kΩ 400 kΩ 500 kΩ 27 μΩ/Ω + 0.0067 Ω 20 μΩ/Ω + 0.010 Ω 19 μΩ/Ω + 0.010 Ω 19 μΩ/Ω + 0.013 Ω 18 μΩ/Ω + 0.014 Ω 18 μΩ/Ω + 0.14 Ω 17 μΩ/Ω + 0.094 Ω 18 μΩ/Ω + 0.74 Ω 17 μΩ/Ω + 0.96 Ω 21 μΩ/Ω + 7.0 Ω 20 μΩ/Ω + 8.5 Ω 39 Ω/MΩ + 110 Ω 83 Ω/MΩ + 220 Ω 150 Ω/MΩ + 0.0025 MΩ 310 Ω/MΩ + 0.0058 MΩ 2.0 kΩ/MΩ + 0.086 MΩ 9.8 kΩ/MΩ + 0.63 MΩ 0.69 µΩ 0.67 µΩ 0.56 µΩ 0.55 µΩ 0.68 µΩ 0.69 µΩ 0.61 µΩ 0.61 µΩ 0.6 µΩ 0.65 µΩ 0.67 µΩ 0.75 µΩ 0.59 µΩ 0.46 µΩ 0.47 µΩ 0.73 µΩ 1 µΩ 0.65 µΩ Fluke 5522A Isotech RB802-18, Fluke 5522A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2736.01) Revised 12/17/2025 Page 4 of 18 Parameter/Equipment Range CMC2, 5 (±) Comments Resistance – Measure (0 to 1.9999) Ω (2 to 19.999) Ω (20 to 199.99) Ω 200 Ω to 1.9999 kΩ (2 to 19.999) kΩ (20 to 199.99) kΩ 200 kΩ to 1.9999 MΩ (2 to 19.999) MΩ (20 to 199.99) ΩM 200 MΩ to 2 GΩ 13 μΩ/Ω + 19 μΩ 9.1 μΩ/Ω + 30 μΩ 8.2 μΩ/Ω + 88 μΩ 8.0 mΩ/kΩ + 0.87 mΩ 8.0 mΩ/kΩ + 6.8 mΩ 8.3 mΩ/kΩ + 61 mΩ 9.9 Ω/MΩ + 1.1 Ω 23 Ω/MΩ + 97 Ω 130 Ω/MΩ + 0.010 MΩ 1.5 MΩ/GΩ + 1.0 MΩ Fluke 8508A Capacitance – Generate (0.22 to 0.3999) nF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.9999) nF (11 to 32.9999) nF (33 to 109.999) nF (110 to 329.999) nF 330 nF to 1.099 99 µF (1.1 to 3.299 99) µF (3.3 to 10.9999) µF (11 to 32.9999) µF (33 to 109.999) µF (110 to 329.999) µF 330 µF to 1.099 99 mF (1.1 to 3.2999) mF (3.3 to 10.9999) mF (11 to 32.9999) mF (33 to 110) mF 25 % + 0.01 nF 22 % + 0.01 nF 21 % + 0.01 nF 0.3 % + 0.01 nF 0.35 % + 0.1 nF 0.3 % + 0.1 nF 0.3 % + 0.3 nF 0.3 % + 1 nF 0.3 % + 3 nF 0.3 % + 10 nF 0.47 % + 30 nF 0.53 % + 100 nF 0.53 % + 300 nF 0.53 % + 1 µF 0.52 % + 3 µF 0.52 % + 10 µF 0.87 % + 30 µF 1.3 % + 100 µF Fluke 5522A
5-thermocouple indicating devices
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2736.01) Revised 12/17/2025 Page 5 of 18 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouple Indicating Devices – Type B Type C Type E Type J Type K Type L Type N Type R (600 to 800) °C (800 to 1000) °C (1000 to 1550) °C (1550 to 1820) °C (0 to 150) °C (150 to 650) °C (650 to 1000) °C (1000 to 1800) °C (1800 to 2316) °C (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-200 to -100) °C (-100 to 800) °C (800 to 900) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 410) °C (410 to 1300) °C (0 to 250) °C (250 to 400) °C (400 to 1000) °C (1000 to 1767) °C 0.59 °C 0.49 °C 0.45 °C 0.48 °C 0.43 °C 0.4 °C 0.44 °C 0.63 °C 1.0 °C 0.62 °C 0.3 °C 0.28 °C 0.3 °C 0.45 °C 0.33 °C 0.22 °C 0.2 °C 0.23 °C 0.29 °C 0.4 °C 0.24 °C 0.22 °C 0.32 °C 0.48 °C 0.43 °C 0.31 °C 0.21 °C 0.55 °C 0.39 °C 0.36 °C 0.36 °C 0.43 °C 0.67 °C 0.42 °C 0.47 °C 0.48 °C Fluke 5522A
See scope document
6-thermocouple indicating devices; RTD indicating devices
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2736.01) Revised 12/17/2025 Page 6 of 18 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouple Indicating Devices – (cont) Type S Type T Type U (0 to 250) °C (250 to 1000) °C (1000 to 1400) °C (1400 to 1767) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C (-200 to 0) °C (0 to 600) °C 0.64 °C 0.54 °C 0.55 °C 0.64 °C 0.81 °C 0.44 °C 0.39 °C 0.38 °C 0.65 °C 0.32 °C Fluke 5522A Electrical Simulation of RTD Indicating Devices – Pt 385, 100 Ω Pt 3926, 100 Ω Pt 3916, 100 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (-200 to -190) °C (-190 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C 0.06 °C 0.06 °C 0.09 °C 0.11 °C 0.12 °C 0.14 °C 0.27 °C 0.06 °C 0.06 °C 0.09 °C 0.11 °C 0.12 °C 0.14 °C 0.29 °C 0.05 °C 0.06 °C 0.07 °C 0.09 °C 0.09 °C 0.11 °C 0.12 °C 0.27 °C Fluke 5522A
See scope document
7-RTD Indicating Devices
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2736.01) Revised 12/17/2025 Page 7 of 18 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of RTD Indicating Devices – (cont) Pt 385, 200 Ω Pt 385, 500 Ω Pt 385, 1000 Ω PtNi 385, 120 Ω (Ni120) Cu 427, 10 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-80 to 0) °C (0 to 100) °C (100 to 260 °C (-100 to 260) °C 0.05 °C 0.05 °C 0.05 °C 0.06 °C 0.14 °C 0.15 °C 0.16 °C 0.19 °C 0.05 °C 0.06 °C 0.06 °C 0.07 °C 0.09 °C 0.09 °C 0.1 °C 0.14 °C 0.05 °C 0.05 °C 0.06 °C 0.07 °C 0.07 °C 0.1 °C 0.1 °C 0.27 °C 0.1 °C 0.1 °C 0.17 °C 0.35 °C Fluke 5522A
See scope document
8-AC Voltage
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2736.01) Revised 12/17/2025 Page 8 of 18 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage – Generate (1 to 32.999) mV (33 to 329.999) mV 330 mV to 3.299 99 V (3.3 to 32.9999) V (33 to 329.999) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 450 μV/V + 8.0 μV 86 μV/V + 5.2 μV 120 μV/V + 5.3 μV 610 μV/V + 6.2 μV 2.2 mV/V + 0.012 mV 4.8 mV/V + 0.055 mV 0.18 mV/V + 0.012 mV 0.078 mV/V + 0.014 mV 0.087 mV/V + 0.015 mV 0.21 mV/V + 0.016 mV 0.52 mV/V + 0.028 mV 1.3 mV/V + 0.078 mV 0.19 mV/V + 0.055 mV 0.091 mV/V + 0.080 mV 0.12 mV/V + 0.074 mV 0.18 mV/V + 0.095 mV 0.45 mV/V + 0.16 mV 1.5 mV/V + 0.82 mV 0.19 mV/V + 0.69 mV 0.09 mV/V + 0.82 mV 0.15 mV/V + 0.76 mV 0.21 mV/V + 1.2 mV 0.57 mV/V + 2.2 mV 0.11 mV/V + 8.8 mV 0.12 mV/V + 10 mV 0.15 mV/V + 9.5 mV 0.15 mV/V + 28 mV 1.3 mV/V + 65 mV 0.19 mV/V + 15 mV 0.16 mV/V + 17 mV 0.18 mV/V + 31 mV Fluke 5522A
See scope document
9-AC Voltage
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2736.01) Revised 12/17/2025 Page 9 of 18 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage – Measure (0 to 199.99) mV 200 mV to 1.9999 V (2 to 19.999) V (20 to 199.99) V (200 to 1000) V (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz (1 to 10) Hz (10 to 40) Hz 40 Hz to 10 kHz 160 μV/V + 18 μV 150 μV/V + 5.3 μV 110 μV/V + 5.4 μV 110 μV/V + 2.9 μV 140 μV/V + 4.7 μV 340 μV/V + 9.2 μV 770 μV/V + 21 μV 130 μV/V + 210 μV 120 μV/V + 23 μV 98 μV/V + 22 μV 77 μV/V + 22 μV 110 μV/V + 22 μV 230 μV/V + 41 μV 580 μV/V + 200 μV 3.0 mV/V + 2.0 mV 10 mV/V + 20 mV 0.14 mV/V + 1.6 mV 0.12 mV/V + 0.22 mV 0.094 mV/V + 0.21 mV 0.078 mV/V + 0.20 mV 0.11 mV/V + 0.21 mV 0.22 mV/V + 0.40 mV 0.58 mV/V + 2.0 mV 3.0 mV/V + 20 mV 10 mV/V + 200 mV 0.15 mV/V + 13 mV 0.12 mV/V + 2.2 mV 0.096 mV/V + 2.3 mV 0.081 mV/V + 2.4 mV 0.11 mV/V + 2.2 mV 0.22 mV/V + 4.3 mV 0.58 mV/V + 20 mV 3.0 mV/V + 200 mV 0.15 mV/V + 70 mV 0.12 mV/V + 20 mV 0.16 mV/V + 17 mV Fluke 8508A
See scope document
10-AC Current
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2736.01) Revised 12/17/2025 Page 10 of 18 Parameter/Range Frequency CMC2, 5 (±) Comments AC Current – Generate (29.00 to 329.99) µA 330 µA to 3.2999 mA (3.3 to 32.999) mA (33 to 329.99) mA (0.33 to 1.099 99) A (1.1 to 2.999 99) A (3 to 10.9999) A (11 to 20.5) A (20 to 1000) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz (45 to 65) Hz (65 to 440) Hz 1.1 μA/mA + 0.19 μA 0.74 μA/mA + 0.20 μA 0.59 μA/mA + 0.20 μA 1.8 μA/mA + 0.20 μA 4.9 μA/mA + 0.33 μA 7.5 μA/mA + 1.8 μA 1.1 μA/mA + 1.3 μA 0.57 μA/mA + 1.3 μA 0.41 μA/mA + 1.4 μA 1.1 μA/mA + 1.2 μA 3.1 μA/mA + 1.0 μA 6.5 μA/mA + 1.0 μA 0.92 μA/mA + 13 μA 0.36 μA/mA + 14 μA 0.10 μA/mA + 15 μA 0.30 μA/mA + 14 μA 1.1 μA/mA + 12 μA 2.5 μA/mA + 11 μA 0.89 mA/A + 0.15 mA 0.34 mA/A + 0.15 mA 0.092 mA/A + 0.16 mA 0.44 mA/A + 0.16 mA 1.1 mA/A + 0.16 mA 2.5 mA/A + 0.19 mA 1.0 mA/A + 0.35 mA 0.27 mA/A + 0.19 mA 4.0 mA/A + 0.69 mA 17 mA/A + 3.4 mA 1.2 mA/A + 0.21 mA 0.39 mA/A + 0.10 mA 4.0 mA/A + 0.69 mA 17 mA/A + 3.4 mA 0.18 mA/A + 7.7 mA 0.39 mA/A + 7.4 mA 20 mA/A + 3.0 mA 0.45 mA/A + 21 mA 0.63 mA/A + 20 mA 20 mA/A + 7.1 mA 0.93 % + 100 mA 0.37 % + 90 mA Fluke 5522A Fluke 5522A, with Fluke 50-turn coil
10 to 1000 A
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2736.01) Revised 12/17/2025 Page 11 of 18 Parameter/Range Frequency CMC2, 5 (±) Comments AC Current – Measure (0 to 220) µA 200 µA to 2 mA (2 to 20) mA (20 to 200) mA 200 mA to 2 A (2 to 20) A (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz 1 Hz to 10 kHz (10 to 30) kHz 10 Hz to 2 kHz (2 to 10) kHz 10 Hz to 2 kHz (2 to 10) kHz 0.04 % + 20 nA 0.04 % + 20 nA 0.09 % + 50 nA 0.04 % + 0.2 µA 0.04 % + 0.2 µA 0.09 % + 2 µA 0.04 % + 2 µA 0.04 % + 2 µA 0.09 % + 2 µA 0.04 % + 20 µA 0.08 % + 20 µA 0.08 % + 200 µA 0.1 % + 200 µA 0.11 % + 2 mA 0.3 % + 2 mA Fluke 8508A III. Fluid Quantities Parameter/Equipment Range CMC2, 4 (±) Comments Mass Flow Rate – Flow Meter & Flow Controller (5 to 500) sccm (> 500 to 5000) sccm (> 5000 to 50 000) sccm 0.21 % + 0.10 sccm 0.20 % + 1.6 sccm 0.21 % + 7.6 sccm Bios Drycal bench
12NIST handbook 44Laboratory BalancesSee scope document
13NIST handbook 44; NIST Handbook 44-300 to 4000 kg
14NIST Handbook 44; NISTIR 6969 SOP 5; NISTIR 6969 SOP 4; NISTIR 6969 SOP 7weightsSee scope document
15NISTIR 6969 SOP 5; NISTIR 6969 SOP 4; NISTIR 6969 SOP 7-See scope document
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2736.01) Revised 12/17/2025 Page 16 of 18 Parameter/Equipment Range CMC2, 4 (±) Comments Volume – Pipettes3 (0.1 to 1) µL (2 to 5) µL (6 to 20) µL (1 to 5) µL (6 to 10) µL (11 to 20) µL (10 to 40) µL (41 to 100) µL (101 to 200) µL (201 to 500) µL (501 to 1000) µL (1001 to 2500) µL (2501 to 5000) µL (5001 to 10 000) µL (10 000 to 50 000) µL 4.1 % 1.4 % 1.7 % 0.07 µL 0.08 µL 0.12 µL 0.23 µL 0.18 µL 0.3 µL 0.91 µL 1.5 µL 5.8 µL 6.4 µL 5.5 µL 29 µL Photometric methods Gravimetric methods, 6-digit balances Gravimetric methods, 5-digit balances V. Thermodynamics Parameter/Equipment Range CMC2, 8 (±) Comments Relative Humidity – Measuring Equipment3 10 % RH 20 % RH 50 % RH 80 % RH 95 % RH 0.51 % RH 0.51 % RH 0.53 % RH 0.51 % RH 0.53 % RH Thunder Scientific 2500ST-LT Temperature – Thermometers & Probes3 (-80 to -30) °C (-30 to 300) °C (300 to 660) °C (660 to 1200) °C 0.016 °C (16 mK) 0.011 °C (11 mK) 0.062 °C (62 mK) 1.6 °C Comparison in liquid bath with SPRT Comparison in liquid & metal block bath with SPRT SPRT with dry block TC with dry block
17

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2736.01) Revised 12/17/2025 Page 17 of 18 Parameter/Equipment Range CMC2 (±) Comments Temperature – Thermometers & Probes Fixed Points -195.798 °C -38.8344 °C 0.01 °C 29.7646 °C 156.598 °C 231.928 °C 419.527 °C 660.323 °C 0.0037 °C (3.7 mK) 0.0023 °C (2.3 mK) 0.0018 °C (1.8 mK) 0.0031 °C (3.1 mK) 0.0032 °C (3.2 mK) 0.0031 °C (3.1 mK) 0.0047 °C (4.7 mK) 0.0079 °C (7.9 mK) Liquid N 2 comparison Mercury cell Water triple point cell Gallium cell Indium cell Tin cell Zinc cell Aluminum cell VI. Time & Frequency Parameter/Equipment Range CMC2, 8 (±) Comments Frequency – Measure 10 MHz 5.8 × 10-10 Hz/Hz Spectracom GPS master oscillator Frequency – Measuring Equipment 0.01 Hz to 2 MHz 1.2 × 10-11 Hz/Hz + 5 µHz Fluke 5522A w/ext 10 MHz reference Stopwatch (0 to 86 400) s/day 0.059 s/day Vibrograf timometer ____________________________________________ 1 This laboratory offers commercial calibration service and field calibration service, where noted. 2 Calibration and Measurement Capability (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the be havior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC.
18

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2736.01) Revised 12/17/2025 Page 18 of 18 4 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated. 5 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a fraction/percentage of the reading plus a fixed floor specification. 6 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches. 7 This Scope meets A2LA’s P112 Flexible Scope Policy. 8 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
19ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

136 Washington Avenue, Nutley, NJ, 07110, US

40.80978, -74.14620

Open in Maps

Other Locations

1 other site in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.