Instru-Met Corporation

931 Lehigh Ave, 07083, Union, NJ, United States

Visit website
A2LA 1377.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
6
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 6 standard numbers and the 2 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM E4
ASTM E83
ASTM E2309
ASTM E2658
ISO 7500-1Metallic materials - Calibration and verification of static uniaxial testing machines - Part 1: Tension/compression testing machines - Calibration and verification of the force-measuring system
ISO 9513Metallic materials - Calibration of extensometer systems used in uniaxial testing

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

4 lines
A2LA

ISO/IEC 17025

Active

1377.01

The scope document we hold says it is valid until 2027-12-31.

View scope

Accredited scope, certificate 1377.01

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ASTM E4; ISO 7500-1-to 20 in
2ASTM E83; ISO 9513; ASTM E2309; ASTM E2658-See scope document
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1377.01) 01/05/2026 Page 3 of 3 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 The type of instrument or material being calib rated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 7 In the statement of CMC, percentages are percentages of reading, unless otherwise indicated.
4ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

931 Lehigh Ave, Union, NJ, 07083, US

40.66523, -74.30453

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.