We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 32 scope lines.
A2LA certificate 3471.01 · 32 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 12 in |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3471.01) 07/18/2025 Page 2 of 31
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
DC Voltage3 – Generate
Up to 220 mV
220 mV to 2.2 V
(2.2 to 11) V
(11 to 22) V
(22 to 220) V
(220 to 1000) V
(0 to 120) mV
(0 to 1.2) V
(0 to 12) V
(0 to 120) V
(0 to 1020) V
0.49 µV + 5.7 nV/mV
0.8 µV + 3.5 µV/V
2.9 µV + 2.5 µV/V
4.3 µV + 2.5 µV/V
43 µV + 3.5 µV/V
0.42 mV + 4.5 µV/V
0.8 µV + 9.3 µV/V
1.9 µV + 5.8 µV/V
10 µV + 6.2 µV/V
0.1 mV + 8.5 µV/V
1 mV + 8.5 µV/V
Fluke 5720A
Fluke 5560A
DC Voltage3 – Generate,
Fixed Points
1.018 V
10 V
2.6 µV
23 µV
Fluke 732B
DC Voltage3 – Measure
Up to 200 mV
200 mV to 2 V
(2 to 20) V
(20 to 200) V
(200 to 1000) V
(1000 to 10 000) V
(1 to 45) kV
(45 to 160) kV
0.24 µV + 5 nV/mV
1.1 µV + 3.7 µV/V
10 µV + 3.5 µV/V
0.88 mV + 3.2 µV/V
1.4 mV + 5.2 µV/V
0.018 %
0.13 %
0.13 %
Fluke 8508A
w/ Fluke 80E-10
Ross Divider, DMM
DC Current3 – Generate
Up to 220 µA
220 µA to 2.2 mA
(2.2 to 22) mA
(22 to 220) mA
220 mA to 2.2 A
(2.2 to 11) A
(11 to 20.5) A
(2 to 20) A
(20 to 100) A
6 nA + 35 pA/µA
7.1 nA + 30 nA/mA
41 nA + 30 nA/mA
0.73 µA + 50 nA/mA
12 µA + 0.11 mA/A
0.49 mA + 0.34 mA/A
9.4 mA + 0.8 mA/A
13 mA + 0.13 mA/A
38 mA + 0.39 mA/A
Fluke 5720A
w/ Fluke 5725A
Fluke 5520A
Valhalla 2555A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3471.01) 07/18/2025 Page 3 of 31
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
DC Current3 – Generate
(cont)
(0 to 120) µA
(0 to 1.2) mA
(0 to 12) mA
(0 to 120) mA
(0 to 1.2) A
(0 to 3.1) A
(0 to 12) A
(0 to 30.2) A
6 nA + 97 µA/A
15 nA + 78 µA/A
82 nA + 78 µA/A
0.82 µA + 78 µA/A
10 µA + 0.12 mA/A
0.15 mA + 0.23 mA/A
0.25 mA + 0.23 mA/A
0.5 mA + 0.78 mA/A
Fluke 5560A
DC Current3 – Measure
Up to 220 µA
200 µA to 2 mA
(2 to 20) mA
(20 to 200) mA
200 mA to 2 A
2.4 nA + 7 pA/µA
7 nA + 11 nA/mA
53 nA + 14 nA/mA
1.5 nA + 47 nA/mA
26 µA + 0.18 mA/A
Fluke 8508A
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
DC Current3 – Measure
Up to 15 A
(15 to 100) A
DC to 60 Hz
DC to 60 Hz
0.0034 %
0.0037 %
Leeds & Northrup 4360
Leeds & Northrup 4361
Clamp Meters3,
AC Current – Generate
Toroidal:
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
Non-Toroidal:
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
26 mA + 2.1 mA/A
50 mA + 1.9 mA/A
0.34 A + 1.9 mA/A
60 mA + 6 mA/A
0.11 A + 5.3 mA/A
0.86 A + 5.3 mA/A
60 mA/A + 3.8 mA/A
0.23 A + 3.7 mA/A
1.2 A + 3.7 mA/A
90 mA + 7.2 mA/A
0.28 A + 6.7 mA/A
1.6 A + 6.7 mA/A
Fluke 5520A w/ coil | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3471.01) 07/18/2025 Page 4 of 31
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Clamp Meters, DC
Current – Generate
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
50 mA + 6.5 mA/A
0.18 A + 3.4 mA/A
0.83 A + 3.3 mA/A
Fluke 5520A w/ coil
Resistance3 – Generate
Fixed Points
0 Ω
1 Ω
1.9 Ω
10 Ω
19 Ω
100 Ω
190 Ω
1 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
1 Ω
10 kΩ
(0 to 10.9999) Ω
(11 to 32.9999) Ω
(33 to 109.9999) Ω
(110 to 329.9999) Ω
(0.33 to 1.099 999) kΩ
(1.1 to 3.299 999) kΩ
(3.3 to 10.999 99) kΩ
(11 to 32.999 99) kΩ
(33 to 109.9999) kΩ
(110 to 329.9999) kΩ
(0.33 to 1.099 999) MΩ
(1.1 to 3.299 999) MΩ
(3.3 to 10.999 99) MΩ
(11 to 32.999 99) MΩ
(33 to 109.9999) MΩ
(110 to 329.9999) MΩ
(330 to 1100) MΩ
50 µΩ
95 µΩ
0.18 mΩ
0.26 mΩ
0.48 mΩ
1.1 mΩ
2.1 mΩ
9 mΩ
17 mΩ
90 mΩ
0.17 Ω
1.1 Ω
2.1 Ω
18 Ω
36 Ω
0.36 kΩ
0.89 kΩ
10 kΩ
12 µΩ
50 mΩ
1.2 mΩ + 24 µΩ/Ω
1.5 mΩ + 24 µΩ/Ω
1.9 mΩ + 22 µΩ/Ω
4.1 mΩ + 22 µΩ/Ω
9.1 mΩ + 22 µΩ/Ω
41 mΩ + 22 µΩ/Ω
92 mΩ + 22 µΩ/Ω
0.41 Ω + 22 µΩ/Ω
0.9 Ω + 22 µΩ/Ω
8.4 Ω + 26 µΩ/Ω
14 Ω + 26 µΩ/Ω
93 Ω + 48 µΩ/Ω
0.4 kΩ + 0.1 mΩ/Ω
4.4 kΩ + 0.2 mΩ/Ω
16 kΩ + 0.4 mΩ/Ω
0.35 MΩ + 2.4 mΩ/Ω
4.4 MΩ + 12 mΩ/Ω
Fluke 5720A
Fluke 742A-1
Fluke 742A-10K
Fluke 5520A | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3471.01) 07/18/2025 Page 5 of 31
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Resistance3 – Generate
Fixed Points (cont)
(0 to 12) Ω
(12 to 120) Ω
120 Ω to 1.2 kΩ
(1.2 to 12) kΩ
(12 to 120) kΩ
120 kΩ to 1.2 MΩ
(1.2 to 12) MΩ
(12 to 120) MΩ
(120 to 1200) MΩ
1 mΩ + 19 µΩ/Ω
1.2 mΩ + 19 µΩ/Ω
4.4 mΩ + 19 µΩ/Ω
44 mΩ + 19 µΩ/Ω
0.44 Ω + 19 µΩ/Ω
4.4 Ω + 19 µΩ/Ω
63 Ω + 27 µΩ/Ω
6.5 kΩ + 0.33 mΩ/Ω
0.47 MΩ + 3.1 mΩ/Ω
Fluke 5560A
Resistance3 – Measure
(0 to 2) Ω
(2 to 20) Ω
(20 to 200) Ω
200 Ω to 2 kΩ
(2 to 20) kΩ
(20 to 200) kΩ
200 kΩ to 2 MΩ
(2 to 20) MΩ
(20 to 200) MΩ
0.36 mΩ + 1.2 µΩ/Ω
58 µΩ + 8.4 µΩ/Ω
0.18 mΩ + 7.6 µΩ/Ω
1.4 mΩ + 7.8 µΩ/Ω
14 mΩ + 7.8 µΩ/Ω
0.13 Ω + 8 µΩ/Ω
1.9 Ω + 10 µΩ/Ω
0.12 kΩ + 21 µΩ/Ω
12 kΩ + 0.12 mΩ/Ω
Fluke 8508A
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
Capacitance3 – Generate,
Fixed Points
1 pF
10 pF
100 pF
1 kHz
1 MHz
2 MHz
3 MHz
4 MHz
5 MHz
10 MHz
13 MHz
1 kHz to 5 MHz
10 MHz
13 MHz
1 kHz to 5 MHz
10 MHz
13 MHz
0.35 fF
0.36 fF
0.42 fF
0.54 fF
0.72 fF
0.95 fF
2.5 fF
3.7 fF
3.5 fF
3.7 fF
3.8 fF
35 fF
48 fF
60 fF
Agilent 16380 series
capacitors | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3471.01) 07/18/2025 Page 6 of 31
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
Capacitance3 – Generate,
Fixed Points (cont)
1000 pF
10 000 pF
1 µF
1 kHz
1 MHz
2 MHz
3 MHz
4 MHz
5 MHz
10 MHz
13 MHz
120 Hz to 100 kHz
120 Hz to 100 kHz
0.35 pF
0.35 pF
0.38 pF
0.45 pF
0.56 pF
0.71 pF
1.9 pF
2.8 pF
3.5 pF
0.4 nF
Agilent 16380 series
capacitors
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
Capacitance3 – Measure
12 Hz to 100 kHz
(1 to 10) pF
(10 to 100) pF
(100 to 1000) pF
(1 to 10) nF
(10 to 100) nF
(100 to 1000) nF
(1 to 10) µF
(10 to 100) µF
0.048 pF + 0.4 pF
0.22 pF
1.1 pF
40 pF
0.11 nF
1 nF
9.2 nF
0.14 µF
GenRad 1689 M
CMC is only valid at
1 kHz
Capacitance3 – Measure
1 nF to 10 mF
100 Hz to 100 kHz
See matrix below
QuadTech 7400
≤ 100 mV Frequency
Range 100 Hz 120 Hz 1 kHz 10 kHz 100 kHz
10 nF 3.9 % 2.8 % 0.28 % 0.13 % 0.13 %
100 nF 0.96 % 0.75 % 0.16 % 0.12 % 0.13 %
1 µF 0.51 % 0.43 % 0.15 % 0.12 % 0.17 %
10 µF 0.46 % 0.4 % 0.15 % 0.15 % 0.42 %
100 µF 0.46 % 0.4 % 0.18 % 0.35 % 3 %
1 mF 0.6 % 0.54 % 0.46 % 2.5 % ----
10 mF 1.6 % 1.6 % 3.4 % ---- ---- | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3471.01) 07/18/2025 Page 7 of 31
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
Capacitance3 – Measure
(cont)
1 nF to 10 mF
100 Hz to 100 kHz
See matrix below
QuadTech 7400
> 100 mV Frequency
Range 100 Hz 120 Hz 1 kHz 10 kHz 100 kHz
10 nF 0.95 % 0.71 % 0.087 % 0.058 % 0.059 %
100 nF 0.24 % 0.2 % 0.066 % 0.058 % 0.059 %
1 µF 0.16 % 0.14 % 0.062 % 0.058 % 0.068 %
10 µF 0.15 % 0.14 % 0.062 % 0.061 % 0.15 %
100 µF 0.15 % 0.14 % 0.072 % 0.13 % 0.96 %
1 mF 0.19 % 0.17 % 0.16 % 0.8 % ----
10 mF 0.52 % 0.51 % 1.1 ---- ----
Capacitance3 – Generate
(0.19 to 0.3999) nF
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.9999) nF
(11 to 32.9999) nF
(33 to 109.999) nF
(110 to 329.999) nF
(0.33 to 1.099 99) µF
(1.1 to 3.2999) µF
(3.3 to 10.9999) µF
(11 to 32.9999) µF
(33 to 109.999) µF
(110 to 329.999) µF
(0.33 to 1.099 99) mF
(1.1 to 3.2999) mF
(3.3 to 10.9999) mF
(11 to 32.9999) mF
(33 to 110) mF
200 pF to 1.2 nF
(1.2 to 12) nF
(> 3 to 12) nF
(12 to 120) nF
(> 30 to 120) nF
(0.12 to 1.2) µF
(1.2 to 12) µF
(12 to 120) µF
(0.12 to 1.2) mF
(1.2 to 12) mF
(12 to 120) mF
10 Hz to 10 kHz
10 Hz to 10 kHz
10 Hz to 10 kHz
(10 to 1000) Hz
(10 to 1000) Hz
(10 to 1000) Hz
(10 to 1000) Hz
(10 to 600) Hz
(10 to 300) Hz
(10 to 150) Hz
(10 to 120) Hz
(10 to 80) Hz
Up to 50 Hz
Up to 20 Hz
Up to 6 Hz
Up to 2 Hz
Up to 0.6 Hz
Up to 0.2 Hz
100 Hz to 10 kHz
150 Hz to 5 kHz
(10 to 150) Hz
200 Hz to 1.3 kHz
(10 to 200) Hz
(2 to 310) Hz
(0.5 to 110) Hz
(0.5 to 40) Hz
(0.1 to 11) Hz
(0.03 to 4) Hz
(0.01 to 1.3) Hz
8.7 pF + 4 pF/nF
9.7 pF + 4 pF/nF
13 pF + 4 pF/nF
15 pF + 2 pF/nF
0.1 nF + 2 pF/nF
0.15 nF + 2 pF/nF
0.46 nF + 2 pF/nF
1.5 nF + 2 nF/µF
4.6 nF + 2 nF/µF
15 nF + 2 nF/µF
59 nF + 3.2 nF/µF
0.2 µF + 3.6 nF/µF
0.64 µF + 3.6 nF/µF
2 µF + 3.6 µF/mF
7 µF + 3.5 µF/mF
38 µF + 2.5 µF/mF
90 µF + 6 µF/mF
0.37 mF + 8.8 µF/mF
2.4 pF + 0.86 mF/F
6.2 pF + 0.9 mF/F
7.8 pF + 0.9 mF/F
43 pF + 1 mF/F
61 pF + 1 mF/F
0.42 nF + 1 mF/F
4.2 nF + 1 mF/F
40 nF + 1.2 mF/F
0.48 µF + 1.9 mF/F
5.3 µF + 1.9 mF/F
77 µF + 3.9 mF/F
Fluke 5522A
Fluke 5560A | ||
| 8 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3471.01) 07/18/2025 Page 8 of 31
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Inductance3 – Measure,
12 Hz to 100 kHz
0.01 µH to 1 mH
(1 to 100) mH
100 mH to 1 H
(1 to 10) H
1.4 µH
0.1 mH
1.4 mH
11 mH
GenRad 1689 M
CMC is only valid at
1 kHz
Inductance3 – Generate,
Fixed Points,
100 Hz to 1 kHz
100 µH
1 mH
10 mH
100 mH
1 H
6.1 nH
1 µH
9.8 µH
54 µH
0.57 mH
GenRad 1482 Series
Inductors
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
Inductance – Generate3
(13 to 120) µH
(0.120 01 to 1.2) mH
(1.2001 to 3.3) mH
(3.3 to 12) mH
(12 to 83) mH
(490 to 550) Hz
(550 to 999) Hz
1 kHz
(1.001 to 13) kHz
(13 to 17) kHz
(260 to 330) Hz
(330 to 999) Hz
1 kHz
(1.001 to 1.6) kHz
(1.6 to 2.5) kHz
(0.5 to 999) Hz
110 Hz
(111 to 800) Hz
(800 to 980) Hz
(0.5 to 109) Hz
110 Hz
(111 to 1000) Hz
(1 to 1.4) kHz
(0.1 to 99) Hz
100 Hz
(101 to 180) Hz
(180 to 230) Hz
1.5 %
0.67 %
0.38 %
0.67 %
1.5 %
1.4 %
0.49 %
0.2 %
0.49 %
1.4 %
0.74 %
0.46 %
0.74 %
1.6 %
0.49 %
0.2 %
0.49 %
1.4 %
0.53 %
0.25 %
0.53 %
1.4 %
Fluke 5560A | 12 to 100000 Hz |
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3471.01) 07/18/2025 Page 9 of 31
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
Inductance – Generate3
(cont)
(83 to 120) mH
(0.120 01 to 0.65) H
(0.65 to 1.2) H
(1.2001 to 5.5) H
(5.5 to 12) H
(12.001 to 30) H
(30 to 120) H
(0.1 to 99) Hz
100 Hz
(101 to 320) Hz
(320 to 1000) Hz
(0.05 to 9.9) Hz
10 Hz
(10.1 to 30) Hz
(30 to 50) Hz
(0.05 to 9.9) Hz
10 Hz
(10.1 to 100) Hz
(100 to 170) Hz
(0.01 to 2.99) Hz
3 Hz
(3.01 to 8) Hz
(8 to 16) Hz
(0.01 to 2.99) Hz
3 Hz
(3.01 to 19) Hz
(19 to 37) Hz
(0.005 to 1.99) Hz
2 Hz
(2.01 to 4) Hz
(4 to 16) Hz
(0.005 to 1.99) Hz
2 Hz
(2.01 to 7) Hz
(7 to 14) Hz
0.49 %
0.2 %
0.49 %
1.4 %
0.61 %
0.32 %
0.6 %
1.5 %
0.52 %
0.24 %
0.52 %
1.4 %
0.68 %
0.4 %
0.68 %
1.6 %
0.57 %
0.28 %
0.57 %
1.4 %
0.89 %
0.61 %
0.89 %
1.8 %
0.61 %
0.32 %
0.6 %
1.5 %
Fluke 5560A | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3471.01) 07/18/2025 Page 10 of 31
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage3 – Generate
220 µV to 2.2 mV
(2.2 to 22) mV
(22 to 220) mV
(0.22 to 2.2) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
4 µV + 0.22 µV/mV
4 µV + 85 nV/mV
4 µV + 75 nV/mV
4 µV + 0.18 µV/mV
5 µV + 0.46 µV/mV
10 µV + 0.9 µV/mV
20 µV + 1.2 µV/mV
20 µV + 2.5 µV/mV
4.5 µV + 0.22 µV/mV
4.2 µV + 85 nV/mV
4.2 µV + 75 nV/mV
4.4µV + 0.18 µV/mV
6.1 µV + 0.46 µV/mV
12 µV + 0.9 µV/mV
23 µV + 1.2 µV/mV
26 µV + 2.5 µV/mV
17 µV + 0.22 µV/mV
9 µV + 85 nV/mV
8.7 µV + 75 nV/mV
11 µV + 0.18 µV/mV
16 µV + 0.46 µV/mV
31 µV + 0.9 µV/mV
48 µV + 1.2 µV/mV
78 µV + 2.5 µV/mV
90 µV + 0.22 mV/V
34 µV + 79 µV/V
18 µV + 39 µV/V
26 µV + 70 µV/V
54 µV + 0.11 mV/V
0.16 mV + 0.34 mV/V
0.56 mV + 0.84 mV/V
0.64 mV + 1.5 mV/V
Fluke 5720A | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3471.01) 07/18/2025 Page 11 of 31
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage3 – Generate
(cont)
(0.22 to 2.2) V
(2.2 to 22) V
(22 to 220) V*
(220 to 1100) V
(220 to 750) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(15 to 50) Hz **
50 Hz to 1 kHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 30) kHz
(30 to 50) kHz
(50 to 100) kHz
90 µV + 0.22 mV/V
34 µV + 79 µV/V
18 µV + 39 µV/V
26 µV + 70 µV/V
54 µV + 0.11 mV/V
0.16 mV + 0.34 mV/V
0.56 mV + 0.84 mV/V
0.64 mV + 1.5 mV/V
0.89 mV + 0.22 mV/V
0.33 mV + 80 µV/V
0.15 mV + 40 µV/V
0.26 mV + 70 µV/V
0.41 mV + 95 µV/V
1.2 mV + 0.26 mV/V
4 mV + 0.9 mV/V
6.1 mV + 1.3 mV/V
8.9 mV + 0.22 mV/V
3.4 mV + 80 µV/V
1.7 mV + 47 µV/V
3.5 mV + 72 µV/V
5.9 mV + 0.13 mV/V
34 mV + 0.8 mV/V
0.13 V + 4.2 mV/V
0.24 V + 7 mV/V
74 mV + 0.26 mV/V
17 mV + 60 µV/V
22 mV + 80 µV/V
34 mV + 0.13 mV/V
93 mV + 0.36 mV/V
93 mV + 0.36 mV/V
0.34 V + 1.3 mV/V
Fluke 5720A
* 220 V range subject
to 2.2E7 V-Hz
limitation
** Max output 250 V
from 15 Hz to 50 Hz
w/ 5725A | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3471.01) 07/18/2025 Page 12 of 31
Parameter/Range
Frequency CMC2, 5 (±) Comments
AC Voltage – Generate3
(1 to 12) mV
(12 to 120) mV
(0.12 to 1.2) V
(1.2 to 12) V
(12 to 120) V
(0.01 to 3) Hz
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.01 to 3) Hz
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.01 to 3) Hz
(3 to 5) Hz
(5 to 10) Hz
(10 to 40) Hz
40.01 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.01 to 3) Hz
(3 to 5) Hz
(5 to 10) Hz
(10 to 40) Hz
40.01 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.01 to 3) Hz
(3 to 5) Hz
(5 to 10) Hz
(10 to 40) Hz
40.01 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz *
0.11 mV + 50 mV/V
8.9 µV + 1.9 mV/V
7.7 µV + 0.68 mV/V
6.1 µV + 0.12 mV/V
6.3 µV + 0.29 mV/V
16 µV + 1.2 mV/V
36 µV + 6.2 mV/V
36 µV + 6.2 mV/V
1.2 mV + 50 mV/V
30 µV + 1.9 mV/V
15 µV + 0.68 mV/V
7.4 µV + 0.11 mV/V
11 µV + 0.27 mV/V
28 µV + 0.62 mV/V
49 µV + 1.6 mV/V
49 µV + 1.6 mV/V
12 mV + 50 mV/V
0.3 mV + 1.9 mV/V
0.15 mV + 0.68 mV/V
74 µV + 0.11 mV/V
21 µV + 0.11 mV/V
42 µV + 0.23 mV/V
0.11 mV + 0.54 mV/V
0.26 mV + 1.5 mV/V
0.26 mV + 1.5 mV/V
0.12 V + 50 mV/V
3 mV + 1.9 mV/V
1.6 mV + 0.68 mV/V
0.49 mV + 0.11 mV/V
0.18 mV + 0.11 mV/V
0.33 mV + 0.23 mV/V
0.77 mV + 0.54 mV/V
2.5 mV + 1.6 mV/V
2.5 mV + 1.6 mV/V
1.2 V + 50 mV/V
30 mV + 1.9 mV/V
16 mV + 0.68 mV/V
4.8 mV + 0.11 mV/V
1.8 mV + 0.11 mV/V
3.3 mV + 0.23 mV/V
7.7 mV + 0.54 mV/V
39 mV + 1.6 mV/V
Fluke 5560A
* Max output 70 V | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3471.01) 07/18/2025 Page 13 of 31
Parameter/Range
Frequency CMC2, 5 (±) Comments
AC Voltage – Generate3 (cont)
(120 to 330) V
(330 to 1020) V
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 10 kHz
0.3 V + 1.9 mV/V
0.16 V + 0.68 mV/V
21 mV + 0.11 mV/V
36 mV + 0.23 mV/V
0.16 V + 1.2 mV/V
0.7 V + 1.9 mV/V
0.3 V + 0.68 mV/V
0.12 V + 0.11 mV/V
Fluke 5560A
AC Voltage3 – Measure
(20 to 200) mV
(0.2 to 2) V
(2 to 20) V
(20 to 200) V
(200 to 1000) V
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
(10 to 40) Hz
40 Hz to 1 kHz
14 µV + 0.16 µV/mV
4.7 µV + 0.12 µV/mV
4.9 µV + 0.1 µV/mV
2.8 µV + 0.1 µV/mV
5.9 µV + 0.13 µV/mV
10 µV + 0.31 µV/mV
25 µV + 0.66 µV/mV
0.15 mV + 0.15 mV/V
38 µV + 0.11 mV/V
36 µV + 88 µV/V
34 µV + 73 µV/V
46 µV + 0.11 mV/V
0.28 mV + 0.14 mV/V
0.3 mV + 0.51 mV/V
0.29 mV + 0.16 mV/V
0.15 mV + 0.12 mV/V
0.31 mV + 80 µV/V
0.11 mV + 74 µV/V
0.2 mV + 0.11 mV/V
0.26 mV + 0.21 mV/V
0.86 mV + 0.51 mV/V
12 mV + 0.16 mV/V
2.7 mV + 0.12 mV/V
2.7 mV + 90 µV/V
2.7 mV + 75 µV/V
3.5 mV + 0.11 mV/V
5.9 mV + 0.21 mV/V
25 mV + 0.51 mV/V
72 mV + 0.15 mV/V
29 mV + 0.11 mV/V
33 mV + 0.11 mV/V
Fluke 8508A | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3471.01) 07/18/2025 Page 14 of 31
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
AC Voltage3 – Measure
(1 to 30) kV
(30 to 100) kV
0.59 %
0.59 %
Ross Divider, DMM
AC Current3 – Measure
(20 to 200) µA
(0.2 to 2) mA
(2 to 20) mA
(20 to 200) mA
(0.2 to 2) A
(2 to 20) A
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
(1 to 2) Hz
2 Hz to 10 kHz
(10 to 30) kHz
10 Hz to 2 kHz
(2 to 10) kHz
0.23 µA + 0.14 nA/µA
20 nA + 0.48 nA/µA
21 nA + 0.62 nA/µA
25 nA + 3.1 nA/µA
0.42 µA + 0.25 µA/mA
0.57 µA + 0.19 µA/mA
0.27 µA + 0.62 µA/mA
0.56 µA + 3.1 µA/mA
48 µA + 33 nA/mA
2.1 µA + 0.29 µA/mA
2.1 µA + 0.62 µA/mA
2.8 µA + 3.1 µA/mA
25 µA + 0.29 µA/mA
21 µA + 0.28 µA/mA
21 µA + 0.58 µA/mA
0.41 mA + 0.05 mA/A
0.28 mA + 0.67 mA/A
0.45 mA + 2.5 mA/A
2.3 mA + 0.72 mA/A
2.5 mA + 1.9 mA/A
Fluke 8508A
AC Current3 – Generate
(0 to 220) µA
(29 to 329.99) µA
220 µA to 2.2 mA
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
63 nA + 0.13 nA/µA
12 nA + 0.14 nA/µA
9.2 nA + 0.11 nA/µA
15 nA + 0.25 nA/µA
75 nA + 0.9 nA/µA
0.69 µA + 13 nA/µA
93 nA + 0.23 µA/mA
67 nA + 0.14 µA/mA
60 nA + 0.11 µA/mA
0.15 µA + 0.18 µA/mA
0.85 µA + 0.9 µA/mA
Fluke 5720A
5520A
Fluke 5720A | ||
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3471.01) 07/18/2025 Page 15 of 31
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current3 – Generate
(cont)
(0.33 to 3.2999) mA
(2.2 to 22) mA
(3.3 to 32.999) mA
(22 to 220) mA
(33 to 329.99) mA
220 mA to 2.2 A
(2.2 to 11) A
(11 to 20.5) A
(11 to 20) A
(11 to 20) A
(20 to 100) A
(10 to 30) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
20 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
Up to 1 kHz
3.3 µA + 8 µA/mA
0.92 µA + 0.23 µA/mA
0.69 µA + 0.14 µA/mA
0.6 µA + 0.11 µA/mA
0.95 µA + 0.18 µA/mA
7 µA + 0.9 µA/mA
14 µA + 3.2 µA/mA
9.3 µA + 0.23 µA/mA
6.8 µA + 0.14 µA/mA
5 µA + 0.11 µA/mA
7.5 µA + 0.18 µA/mA
30 µA + 0.9 µA/mA
.27 mA + 3.2 µA/mA
89 µA + 0.24 mA/A
0.17 mA + 0.39 mA/A
1.5 mA + 6 mA/A
1.1 mA + 0.4 mA/A
2.3 mA + 0.85 mA/A
8.0 mA + 3.3 mA/A
15 mA + 0.96 mA/A
17 mA + 1.2 mA/A
0.27 A + 24 mA/A
42 mA + 1.7 mA/A
0.15 A + 1.7 mA/A
5520A
5720
5520A
5720A
5520A
Fluke 5720A
w/5725A
Fluke 5520A
Valhalla 2555A | ||
| 16 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3471.01) 07/18/2025 Page 16 of 31
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current – Generate3
(12 to 120) µA
(0.12 to 1.2) mA
(1.2 to 12) mA
(12 to 120) mA
(0.12 to 1.2) A
(1.2 to 3.1) A
(3.1 to 12) A
(12 to 30) A
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
12 nA + 0.19 mA/A
12 nA + 0.19 mA/A
12 nA + 0.19 mA/A
52 nA + 1.2 mA/A
1 µA + 3.9 mA/A
0.13 µA + 0.19 mA/A
0.13 µA + 0.19 mA/A
0.13 µA + 0.19 mA/A
0.25 µA + 1.2 mA/A
5.5 µA + 3.9 mA/A
1.3 µA + 0.19 mA/A
1.3 µA + 0.19 mA/A
1.3 µA + 0.19 mA/A
2.5 µA + 1.2 mA/A
15 µA + 3.9 mA/A
13 µA + 0.19 mA/A
6.5 µA + 0.12 mA/A
10 µA + 0.19 mA/A
25 µA + 1.2 mA/A
0.15 mA + 3.9 mA/A
0.13 mA + 0.18 mA/A
75 µA + 0.19 mA/A
0.1 mA + 0.19 mA/A
0.53 mA + 1.9 mA/A
0.77 mA + 3.9 mA/A
0.85 mA + 0.29 mA/A
0.58 mA + 0.23 mA/A
0.65 mA + 0.29 mA/A
2.8 mA + 1.9 mA/A
1.9 mA + 0.29 mA/A
1.2 mA + 0.23 mA/A
1.7 mA + 0.29 mA/A
6.9 mA + 1.9 mA/A
19 mA + 0.78 mA/A
15 mA + 0.54 mA/A
55 mA + 3.9 mA/A
Fluke 5560A | 12 to 30 A |
| 17 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3471.01) 07/18/2025 Page 17 of 31
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
Oscilloscopes3 –
DC
50 Ω
1 MΩ
Square
50 Ω
1 MΩ
Fast Edge
Leveled Sine
Amplitude
Leveled Sine Flatness
Relative to 50 kHz
Relative to 10 MHz
Time Marker
(0 to 6.6) V
(0 to 6.6) V
1 mV to 6.6 Vp-p
1 mV to 130 Vp-p
≤ 150 ps
50 kHz Reference
10 MHz Reference
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 500) MHz
(500 to 600) MHz
600 MHz to 1.1 GHz
(1.1 to 1.6) GHz
(1.6 to 2.1) GHz
5 s to 50 ms
20 ms to 500 ps
0.84 mV + 2.4 mV/V
0.95 mV + 0.25 mV/V
0.72 mV + 2.4 mV/V
2.2 mV + 0.49 mV/V
29 ps
1.8 mV + 20 mV/V
1.9 mV + 20 mV/V
1 mV + 38 mV/V
0.94 mV + 45 mV/V
0.92 mV + 65 mV/V
0.91 mV + 72 mV/V
0.97 mV + 86 mV/V
1.2 mV + 86 mV/V
1 mV + 0.1 V/V
0.0012 % + 5 ns
0.0003 %
Fluke 5820A
Distortion3 – Measure
(-60 to 0) dB
(-100 to 0) dB
20 Hz to 20 kHz
(20 to 100) kHz
100 kHz to 2.5 GHz
(2.5 to 22) GHz
(22 to 26.5) GHz
1.2 dB
2.3 dB
2.1 dB
3.3 dB
4.2 dB
8903B
8563EC | to 6.6 V |
| 18 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3471.01) 07/18/2025 Page 18 of 31
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
Duty Cycle3, 8 – Generate
(1 to 9.99) %
(10 to 49.99) %
50 %
(50.01 to 90) %
(90.01 to 99) %
0.33 %
0.02 %
0.013 %
0.02 %
0.32 %
Fluke 5520A
Electrical Calibration of
Thermocouple Indicators
& Indicating Systems3 –
Type E
Type J
Type K
Type R
Type S
Type T
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1750) °C
(0 to 250) °C
(250 to 1000) °C
(1000 to 1400) °C
(1400 to 1750) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.59 °C
0.21 °C
0.17 °C
0.19 °C
0.29 °C
0.33 °C
0.25 °C
0.19 °C
0.2 °C
0.28 °C
0.39 °C
0.28 °C
0.19 °C
0.32 °C
0.5 °C
0.67 °C
0.41 °C
0.39 °C
0.48 °C + 0.061 m °C/°C
0.65 °C
0.42 °C
0.43 °C
0.55 °C + 0.054 m °C/°C
0.74 °C
0.3 °C
0.21 °C
0.16 °C
Martel 3001 | ||
| 19 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3471.01) 07/18/2025 Page 19 of 31
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration of
RTD Indicators &
Indicating Systems3 –
Pt 385, 100 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
0.047 °C
0.058 °C
0.058 °C
0.047 °C
0.048 °C
0.061 °C + 0.016 m °C/°C
0.064 °C + 0.021 m °C/°C
Martel 3001
Parameter/Range
Frequency CMC2 (±) Comments
Phase3 (PF=1)
(10 to 65) Hz
(65 to 500) Hz
500 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 65) Hz
(65 to 500) Hz
500 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
Ø 0.1 °
Ø 0.26 °
Ø 0.51 °
Ø 2.6 °
Ø 5.1 °
Ø 10 °
Ø 0.1 °
Ø 0.2 °
Ø 0.4 °
Ø 1.9 °
Ø 3.9 °
Ø 7.8 °
Fluke 5520A
Fluke 5560A | ||
| 20 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3471.01) 07/18/2025 Page 20 of 31
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
AC Power3 –
Generate See Table below See Table below Fluke 5520A
(45 to 65) Hz
(3.366 to
33.66)
W
(33.66 to
336.6) W
(0.3366 to
1.122) kW
(1.122 to
3.06) kW
(3.06 to
11.22) kW
(11.22 to 20.9)
kW
Ø 0 °
PF=1.000 0.052 % 0.068 % 0.076 % 0.083 % 0.17 %
Ø 10 °
PF=0.985 0.06 % 0.075 % 0.082 % 0.088 % 0.18 %
Ø 20 °
PF=0.940 0.082 % 0.093 % 0.099 % 0.1 % 0.18 %
Ø 30 °
PF=0.866 0.11 % 0.12 % 0.13 % 0.2 %
Ø 40 °
PF=0.766 0.16 % 0.17 % 0.23 %
Ø 50 °
PF=0.643 0.21 % 0.22 % 0.27 %
Ø 60 °
PF=0.500 0.31 % 0.35 %
Ø 70 °
PF=0.342 0.48 % 0.49 % 0.51 %
Ø 80 °
PF=0.174 0.99 % 1 %
(65 to 500) Hz (33.66 to
336.6) W
(0.3366 to
1.122) kW
(1.122 to 3.06)
kW
(3.06 to 11.22)
kW
(11.22 to 20.9)
kW
Ø 0 °
PF=1.000 0.052 % 0.068 % 0.076 % 0.12 % 0.21 %
Ø 10 °
PF=0.985 0.094 % 0.1 % 0.11 % 0.14 % 0.22 %
Ø 20 °
PF=0.940 0.17 % 0.18 % 0.2 % 0.26 %
Ø 30 °
PF=0.866 0.26 % 0.28 % 0.33 %
Ø 40 °
PF=0.766 0.37 % 0.39 % 0.42 %
Ø 50 °
PF=0.643 0.53 % 0.56 %
Ø 60 °
PF=0.500 0.76 % 0.77 % 0.78 %
Ø 70 °
PF=0.342 1.2 %
Ø 80 °
PF=0.174 2.5 % | ||
| 21 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3471.01) 07/18/2025 Page 21 of 31
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
AC Power – Generate3 (cont)
See Table below
See Table below
Fluke 5560A
500 Hz to 1
kHz
(33.66 to
336.6) W
(0.3366 to 1.122)
kW (1.122 to 3.06) kW (3.06 to
11.22) kW
(11.22 to
20.9) kW
Ø 0 °
PF=1.000 0.052 % 0.068 % 0.076 % 0.12 % 0.21 %
(45 to 65) Hz (1.22 to
12.2) W
(12.2 to
122) W
(0.122 to
1.22) kW
(1.22 to 3.16)
kW
(3.16 to
12.2) kW
(12.2 to
30.8) kW
Ø 0 °
PF=1.000 0.038 % 0.029 % 0.034 % 0.048 % 0.04 % 0.11 %
Ø 10 °
PF=0.985 0.049 % 0.042 % 0.046 % 0.057 % 0.051 % 0.11 %
Ø 20 °
PF=0.940 0.074 % 0.07 % 0.072 % 0.079 % 0.075 % 0.12 %
Ø 30 °
PF=0.866 0.11 % 0.15 %
Ø 40 °
PF=0.766 0.15 %
Ø 50 °
PF=0.643 0.21 %
Ø 60 °
PF=0.500 0.3 %
Ø 70 °
PF=0.342 0.48 %
Ø 80 °
PF=0.174 0.99 %
(65 to 500) Hz (12.2 to 122)
W
(0.122 to 1.22)
kW
(1.22 to 3.16)
kW
(3.16 to 12.2)
kW
(12.2 to 30.8)
kW
Ø 0 °
PF=1.000 0.029 % 0.034 % 0.048 % 0.04 % 0.11 %
Ø 10 °
PF=0.985 0.068 % 0.071 % 0.078 % 0.074 % 0.12 %
Ø 20 °
PF=0.940 0.14 % 0.17 %
Ø 30 °
PF=0.866 0.2 % 0.21 % 0.23 %
Ø 40 °
PF=0.766 0.29 % 0.3 % 0.31 %
Ø 50 °
PF=0.643 0.42 %
(65 to 500) Hz (12.2 to
122) W
(0.122 to 1.22)
kW (1.22 to 3.16) kW (3.16 to
12.2) kW
(12.2 to 30.8)
kW
Ø 60 °
PF=0.500 0.61 % | 500 to 1000 Hz |
| 22 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3471.01) 07/18/2025 Page 22 of 31
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
AC Power – Generate3 (cont)
See Table below
See Table below
Fluke 5560A
(65 to 500) Hz (12.2 to
122) W
(0.122 to 1.22)
kW (1.22 to 3.16) kW (3.16 to
12.2) kW
(12.2 to
30.8) kW
Ø 70 °
PF=0.342 0.96 %
Ø 80 °
PF=0.174 2 %
500 Hz to 1 kHz (12.2 to 122)
W
(0.122 to
1.22) kW
(1.22 to 3.16)
kW
(3.16 to 12.2)
kW
(12.2 to 30.8)
kW
Ø 0 °
PF=1.000 0.029 % 0.034 % 0.048 % 0.04 % 0.11 %
Ø 10 °
PF=0.985 0.13 % 0.16 %
Ø 20 °
PF=0.940 0.26% 0.28 %
Ø 30 °
PF=0.866 0.41% 0.42 %
Ø 40 °
PF=0.766 0.59 % 0.6 %
Ø 50 °
PF=0.643 0.83 %
Ø 60 °
PF=0.500 1.2 %
Ø 70 °
PF=0.342 1.9 %
Ø 80 °
PF=0.174 4 %
(1 to 5) kHz (6 to 60) W (60 to 600) W (0.6 to 1.55) kW
Ø 0 °
PF=1.000 0.071 % 0.082 %
Ø 10 °
PF=0.985 0.64 %
Ø 20 °
PF=0.940 1.3 %
Ø 30 °
PF=0.866 2 %
Ø 40 °
PF=0.766 2.8 %
Ø 50 °
PF=0.643 4 %
(5 to 10) kHz (3 to 30) W (30 to 300) W
Ø 0 °
PF=1.000 0.28 % 0.34 % | ||
| 23 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3471.01) 07/18/2025 Page 23 of 31
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
AC Power – Generate3
(cont)
See Table below
See Table below
Fluke 5560A
(5 to 10) kHz (3 to 30) W (30 to 300) W
Ø 10 °
PF=0.985 1.4 %
Ø 20 °
PF=0.940 2.7 %
Ø 30 °
PF=0.866 4.2 %
(10 to 30) kHz (3 to 300) W
Ø 0 °
PF=1.000 1.1 %
Ø 10 °
PF=0.985 3.4 %
Ø 20 °
PF=0.940 5.9%
Parameter/Frequency
Range
CMC2, 4, 5 (±)
Comments
DC Power3 – Generate
Up to 330 µA
Up to 3.3 mA
Up to 33 mA
Up to 330 mA
Up to 1.1 A
Up to 3 A
Up to 11 A
Up to 20.5 A
Up to 120 µA
Up to 1.2 mA
Up to 12 mA
Up to 120 mA
Up to 1.2 A
Up to 3.1 A
Up to 12 A
Up to 30.2 A
Up to 1020 V
Up to 337 mW
(0.337 to 3.366) W
(3.366 to 33.66) W
(33.66 to 336.6) W
(0.3366 to 1.122) kW
(1.122 to 3.06) kW
(3.06 to 11.22) kW
(11.22 to 20.91) kW
Up to 122 mW
(0.12 to 1.224) W
(1.225 to 12.24) W
(12.24 to 122.4) W
(0.1224 to 1.224) kW
(1.224 to 3.162) kW
(3.162 to 12.24) kW
(12.24 to 30.8) kW
0.017 %
0.021 %
0.0093 %
0.0093 %
0.019 %
0.043 %
0.044 %
0.13 %
0.015 %
0.0092 %
0.0087 %
0.0087 %
0.013 %
0.028 %
0.025 %
0.08 %
Fluke 5520A
Fluke 5560A | ||
| 24 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3471.01) 07/18/2025 Page 24 of 31
III. RF/Microwave
Parameter/Range
Frequency CMC2, 4, 5 (±) Comments
Power Meter3
Power Reference @ 1 mW
Power Accuracy
50 MHz
3 µW to 100 mW
0.60 %
0.29 %
Agilent 432A, 8478B,
Agilent 3458A
Range calibrator
Relative Power3 – Measure
(0 to -10) dB
(-10 to -20) dB
(-20 to -30) dB
(-30 to -40) dB
(-40 to -50) dB
(-50 to -60) dB
(-60 to -70) dB
(-70 to -80) dB
(-80 to -90) dB
(-90 to -100) dB
(-100 to -110) dB
(-110 to -120) dB
(-120 to -127) dB
(0 to -10) dB
(-10 to -20) dB
(-20 to -30) dB
(-30 to -40) dB
(-40 to -50) dB
(-50 to -60) dB
(-60 to -70) dB
(-70 to -80) dB
(-80 to -90) dB
(-90 to -100) dB
(-100 to -110) dB
(-110 to -120) dB
(-120 to -127) dB
2.5 MHz to 1.3 GHz
(1.3 to 26.5) GHz
0.047 dB
0.06 dB
0.074 dB
0.087 dB
0.1 dB
0.1 dB
0.11 dB
0.12 dB
0.13 dB
0.15 dB
0.15 dB
0.28 dB
0.29 dB
0.066 dB
0.06 dB
0.074 dB
0.087 dB
0.1 dB
0.1 dB
0.11 dB
0.12 dB
0.13 dB
0.15 dB
0.15 dB
0.28 dB
0.29 dB
8902A | ||
| 25 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3471.01) 07/18/2025 Page 25 of 31
Parameter/Range
Frequency CMC2, 4, 5 (±) Comments
Absolute Power3 –
Measure
(0 to +20) dBm
(-10 to 0) dBm
(-60 to -10) dBm
(+10 to +20) dBm
(-30 to +10) dBm
9 kHz to 6 GHz
100 kHz to 4.2 GHz
(4.2 to 26.5) GHz
100 kHz to 4.2 GHz
(4.2 to 26.5) GHz
2.9 %
3.3 %
3.9 %
1.1 %
3.2 %
3.6 %
4.7 %
Agilent E4418B w/
Agilent E9304A
Agilent 8482A
Agilent 8485A
Agilent 8482A
Agilent 8485A
Amplitude Modulation3 –
Measure
Rate: 50 Hz to 10 kHz
Depths: (5 to 99) %
Rate: 20 Hz to 10 kHz
Depths: to 99 %
Rate: 50 Hz to 50 kHz
Depths: (5 to 99) %
Rate: 20 Hz to 100 kHz
Depths: to 99 %
Rate: 50 Hz to 50 kHz
Depths: (5 to 99) %
Rate: 20 Hz to 100 kHz
Depths: to 99 %
150 kHz to 10 MHz
150 kHz to 10 MHz
(0.01 to 1.3) GHz
(0.01 to 1.3) GHz
(1.3 to 26.5) GHz
(1.3 to 26.5) GHz
0.14 % depth + 0.024 %
depth/% depth
0.11 % depth + 0.023 %
depth/% depth
0.15 % depth + 0.01 %
depth/% depth
0.11 % depth + 0.023 %
depth/% depth
0.33 % depth + 0.008 %
depth/% depth
0.31 % depth + 0.021 %
depth/% depth
8902A
Frequency Modulation3 –
Measure
Rate: 20 Hz to 10 kHz
Dev.: ≤ 40 kHz Peak
Rate: 50 Hz to 100 kHz
Dev.: ≤ 400 kHz Peak
Rate: 20 Hz to 200 kHz
Dev.: ≤ 400 kHz Peak
250 kHz to 10 MHz
(0.01 to 1.3) GHz
(0.01 to 1.3) GHz
3.5 Hz + 16 Hz/kHz
3.5 Hz + 7.8 Hz/kHz
6.8 Hz + 39 Hz/kHz
8902A | ||
| 26 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3471.01) 07/18/2025 Page 26 of 31
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
Frequency Modulation3 –
Measure (cont)
Rate: 50 Hz to 100 kHz
Dev.: ≤ 400 kHz Peak
Rate: 20 Hz to 200 kHz
Dev.: ≤ 400 kHz Peak
(1.3 to 26.5) GHz
(1.3 to 26.5) GHz
6.8 Hz + 7.8 Hz/kHz
6.8 Hz + 39 Hz/kHz
8902A
Phase Modulation3 –
Measure
Rate: 200 Hz to 10 kHz
(0 to 100) rad
Rate: 200 Hz to 20 kHz
(0 to 100) rad
Rate: 200 Hz to 20 kHz
(0 to 100) rad
150 kHz to 10MHz
(0.01 to 1.3) GHz
(1.3 to 26.5) GHz
36 mrad + 37 mrad/rad
36 mrad + 37 mrad/rad
36 mrad + 37 mrad/rad
8902A
Power Sensor Calibration
Factor
9 kHz to 10 MHz
10 MHz to 2 GHz
(2 to 3.6) GHz
(3.6 to 4.6) GHz
(4.6 to 9) GHz
(9 to 11.8) GHz
(11.8 to 16.25) GHz
(16.25 to 18) GHz
1.7 %
0.57 %
0.59 %
0.61 %
0.65 %
0.74 %
0.78 %
0.94 %
Power sensor
calibration system
w/ Tegam 1805B
power meter,
Agilent E9304A,
F1109 power
reference
Displayed Average Noise
Level3, 8
DC to 2 GHz
(> 2 to ≤ 3) GHz
(> 3 to ≤ 6) GHz
0.39 dB
0.16 dB
0.3 dB
50 Ω termination | ||
| 27 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3471.01) 07/18/2025 Page 27 of 31
Parameter/Range
Frequency
CMC2 (±)
Comments
S-Parameters (Reflection &
Transmission)
300 kHz to 6 GHz
See tables below
(Interpolate CMC’s
between cardinal
points listed)
Network
analyzers with
calibration/
verification kits
Type N: Reflection S11/S22 Linear Magnitude (ρ) E5071C with 85032B
rho 300 kHz to 10 MHz 10 MHz to 3 GHz (3 to 6) GHz
0 0.0039 0.0052 0.011
0.1 0.0046 0.0061 0.012
0.2 0.0054 0.0073 0.014
0.3 0.0064 0.0086 0.017
0.4 0.0074 0.01 0.02
0.5 0.0086 0.012 0.024
0.6 0.01 0.015 0.028
0.7 0.012 0.017 0.033
0.8 0.013 0.02 0.038
0.9 0.015 0.023 0.044
1.0 0.017 0.026 0.05
Type N: Reflection S11/S22 Phase (0 to 180)° E5071C with 85032B
rho 300 kHz to 10 MHz 10 MHz to 3 GHz (3 to 6) GHz
0 ---- ---- ----
0.1 2.6 3.4 7
0.2 1.5 2.1 4.1
0.3 1.2 1.6 3.2
0.4 1.1 1.5 2.9
0.5 0.99 1.4 2.7
0.6 0.95 1.4 2.7
0.7 0.95 1.4 2.7
0.8 0.95 1.4 2.7
0.9 0.96 1.5 2.8
1.0 0.98 1.5 2.9
Type N: Transmission S12/S21 Linear Magnitude (dB) E5071C with 85032B
dB 300 kHz to 10 MHz 10 MHz to 3 GHz (3 to 6) GHz
-90 8 2.6 2.7
-80 3.4 1 1
-70 1.3 0.42 0.47
-60 0.45 0.23 0.28
-50 0.19 0.16 0.21
-40 0.12 0.12 0.18
-30 0.088 0.097 0.15
-20 0.067 0.076 0.13 | 300000 to 6000000000 Hz |
| 28 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3471.01) 07/18/2025 Page 28 of 31
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
S-Parameters (Reflection &
Transmission)
300 kHz to 6 GHz
See tables below
(Interpolate CMC’s
between cardinal
points listed)
Network
analyzers with
calibration/
verification kits
Type N: Transmission S12/S21 Linear Magnitude (dB) E5071C with 85032B
dB 300 kHz to 10 MHz 10 MHz to 3 GHz (3 to 6) GHz
-10 0.056 0.066 0.12
0 0.046 0.056 0.11
10 0.063 0.073 0.13
Type N: Transmission S12/S21 Phase (0 to 180)° E5071C with 85032B
dB 300 kHz to 10 MHz 10 MHz to 3 GHz (3 to 6) GHz
-90 ---- 21 21
-80 29 7.1 7.4
-70 8.9 2.9 3.2
-60 3 1.5 1.9
-50 1.3 1 1.4
-40 0.79 0.81 1.2
-30 0.59 0.65 1
-20 0.45 0.51 0.88
-10 0.38 0.44 0.82
0 0.32 0.38 0.76
10 0.45 0.52 0.9
Attenuation3 – Generate
(1 to 11) dB
(12 to 121) dB
DC to 8 GHz
(8 to 12.4) GHz
(12.4 to 18) GHz
DC to 8 GHz
(8 to 12.4) GHz
(12.4 to 18) GHz
0.22 dB
0.29 dB
0.51 dB
0.22 dB + 0.0011 x ΔA
Change from 12 dB
0.28 dB + 0.001 x ΔA
Change from 12 dB
0.51 dB + 0.0006 x ΔA
Change from 12 dB
Agilent 8494H
Agilent 8494H,
8496H | ||
| 29 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3471.01) 07/18/2025 Page 29 of 31
IV. Mechanical
Parameter/Equipment
Range
CMC2, 5, 7 (±)
Comments
Scales3
Up to 400 lbs
0.82 x R
Class F weights
Balances3
0.0001 g Resolution
0.001 g Resolution
0.01 g Resolution
0.1 g Resolution
1 g & 10 g Resolution
(5 to 500) mg
> 500 mg to 5 g
> 5 g to 6 kg
5 mg to 10 g
(> 10 to 50) g
> 50 g to 6 kg
5 mg to 300 g
> 300 g to 6 kg
5 mg to 2 kg
(2 to 6) kg
5 mg to 6 kg
0.82 x R
0.91 x R
1.0 x R
0.82 x R
0.91 x R
1.4 x R
0.82 x R
1.4 x R
0.85 x R
1.0 x R
0.82 x R
Class 1, 3 & 4
weights
Pressure –Measuring
Equipment3
(-1 to 0) psig
(0 to 1) psig
(0 to 15) psig
(15 to 30) psig
(30 to 500) psig
(500 to 3000) psig
(3000 to 5000) psig
(0 to 1) inH2O
0.013 psi + 0.6 R
0.012 psi
0.052 psi
0.034 psi
0.44 psi
0.85 psi
3 psi
0.001 inH
2O
Pressure modules
Druck DPI 610
pressure calibrator
Torque Tools –
Wrenches, Gages &
Drivers3
(0.5 to 5) lbf·in
(5 to 50) lbf·in
(50 to 400) lbf·in
(400 to 1000) lbf·in
(83 to 600) lbf·ft
0.58 %
0.58 %
0.29 %
0.3 %
0.29 %
Torque testers
Torque – Measuring
Equipment3
5 ozf·in to 10 lbf·in
(10 to 1000) lbf·in
0.05 %
0.036 %
Torque arms & Class
4 & Class F weights | to 400 lbs |
| 30 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3471.01) 07/18/2025 Page 30 of 31
V. Thermodynamics
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Relative Humidity –
Measuring Equipment3
11 %, 33 %, 75 %
1.4 % RH
Saturated salts/ Vaisala
MI 70, HMP 77B
Relative Humidity –
Measure3
(20 to 80) % RH
1.4 % RH
Vaisala MI 70, HMP
77B
Temperature –
Measuring Equipment3
Digital & Analog
Thermometers
(-25 to 140) °C
(140 to 660) °C
0.06 °C
0.1 °C
Accumac 1751 PRT,
8508A, Calibration
Baths & Wells
Temperature –
Measure
3
Fridges, Freezers,
Chambers, Thermal
Baths
(-196 to 660) °C
0.011 °C + ΔT(Change
from -196 °C) x 0.000
003
Accumac AM 1751/ w
8508A
Infrared Temperature –
Measuring Equipment3
(35 to 500) °C
0.54 °C + ΔT(Change from 35
°C) x 0.0042
Fluke 4181
Ɛ = 0.9 to 1
λ = (8 to 14) µm
VI. Time & Frequency
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Frequency
10 MHz
12 µHz
58503A GPS
Receiver
Frequency – Measuring
Equipment3
100 mHz to 20 MHz
20 MHz to 50 GHz
55 µHz + 26 pHz/Hz
0.58 mHz + 1 pHz/Hz
3325B function
generator
E8257D signal
generator | ||
| 31 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3471.01) 07/18/2025 Page 31 of 31
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Frequency – Measure3
0.1 Hz to 3 GHz
(3 to 26.5) GHz
(26.5 to 50) GHz
5.8 µHz + 59 pHz/Hz
0.11 Hz + 0.36 pHz/Hz
0.12 Hz + 0.53 pz/Hz
53131A frequency
counter
5351B microwave
counter
E4448A spectrum
analyzer
Stopwatches & Timers
± (0 to 19.99) sec/day
0.037 sec/day
Helmut Klein 4500
Timometer
_____________________________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a
percentage or fraction of the reading plus a fixed floor specification.
5 In the statement of CMC, percentages are to be read as percent of reading unless otherwise noted. In the
statement of CMC, R represents the resolution of the unit under test, L is the numerical value of the length
of the device measured in inches.
6 This scope meets A2LA’s P112 Flexible Scope Policy.
7 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 32 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- AH Electronic Test Equipment Repair CenterIslip, NY · ~9 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- CONNECTICUT CALIBRATION TECHNOLOGIES, INC., dba CONNECTICUT CALIBRATIONNewtown, CT · ~73 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- AALFA - KAL Metrology Laboratory, division of AALBORG Instruments & ControlsOrangeburg, NY · ~78 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Atlantic Scale CompanyNutley, NJ · ~86 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Instru-Met CorporationUnion, NJ · ~101 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.