Registers refreshed 2026-11-08.See refresh dates
China

Guangzhou Jingce Testing Technology Co.,Ltd.

No.10, Hefeng No.1 street, Huangpu District, Guangzhou, Guangdong, People's Republic of China, Guangzhou, Guangdong,, China

Visit website
A2LA 6594.03ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
30
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 30 standard numbers and the 18 official names we hold. When no standard matches, it searches the method text of every scope line.

ETSI13
ETSI EN 300 220-1
ETSI EN 300 220-2
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 330Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 300 440
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-17
ETSI EN 301 893
ETSI EN 303 340
ETSI EN 303 372-2
ETSI EN 303 417
ETSI EN 303 687
IEC 61000 series9
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
Other standards8
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements

Certificate says EN 55035. Probably the same standard; not checked against the EN document.

EN 50663Generic standard for assessment of low power electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (10 MHz - 300 GHz)
EN 50665
FCC PART 15Radio Frequency Devices
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)

Certificate says EN 62311. Probably the same standard; not checked against the EN document.

IEC 62479Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.

Scope as published by A2LA

4 lines
A2LA

ISO/IEC 17025

Active

6594.03

The scope document we hold says it is valid until 2028-01-31.

View scope

Accredited scope, certificate 6594.03

LineMethodMatrixRange
1CFR 47, FCC Part 15, Subpart B; ANSI C63.4:2014; CFR 47, FCC Part 18; FCC MP-5:1986; ICES-001; ICES-003; CISPR 32; EN 55032; IEC 61000-3-2; EN 61000-3-2; IEC 61000-3-3; EN 61000-3-3; ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-17; CISPR 35; EN 55035; IEC 61000-4-2; EN 61000-4-2; IEC 61000-4-3; EN 61000-4-3; IEC 61000-4-4; EN 61000-4-4; IEC 61000-4-5; EN 61000-4-5--
2IEC 61000-4-6; EN 61000-4-6; IEC 61000-4-8; EN 61000-4-8; IEC 61000-4-11; EN 61000-4-11; CFR 47, FCC Part 15 Subpart C; ANSI C63.10:2020; CFR 47, FCC Part 15, Subpart E; FCC KDB 905462 D02 (v02); ANSI C63.10:2013; RSS-GEN; RSS-210; RSS-216; RSS-247; RSS-248; ANSI C63.10-2020+Cor.1-2023+C63.10a-2024+Errata to C63.10a-2024; AS/NZS 4268; EN 300 220-1; EN 300 220-2; EN 300 328; EN 301 893; EN 300 330; EN 300 440; ETSI EN 303 417; ETSI EN 303 687; EN 303 340; EN 303 372-2; EN 62479; EN 62311; EN 50663; EN 50665; KDB 447498 (D01); AS/NZS 2772.2; IEEE C95.3; CFR 47, FCC Part 15, Subpart B; ANSI C63.4:2014; CFR 47, FCC Part 18; FCC MP-5:1986; ANSI C63.4; ICES-001; ICES-003; CISPR 32; EN 55032; ANSI C63.10:2020+Cor.1-2023+C63.10a-2024+Errata to C63.10a-2024-to 40 GHz
3ANSI C63.4:2014; ANSI C63.10:2020; FCC MP-5:1986; FCC KDB 905462 D02 (v02)-to 40000 MHz
4

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited GUANGZHOU JINGCE TESTING TECHNOLOGY CO., LTD. Guangdong, People’s Republic of China for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 4th day of February 2026. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 6594.03 Valid to January 31, 2028

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

No.10, Hefeng No.1 street, Huangpu District, Guangzhou, Guangdong, People's Republic of China, Guangzhou, Guangdong,, CN

23.11981, 113.31478

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.