SHENZHEN CENTRAL STANDARD INTERNATIONAL CENTER CO.,
Room 201, Building 1, Mogen Fashion Industrial Park, No. 10, Shilongzai Road, Xinshi Community, Dalang Street, Longhua District, Shenzhen, 518109, People's Republic of China, Shenzhen, China
Visit website- Accredited standards
- 10
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 10 standard numbers and the 9 official names we hold. When no standard matches, it searches the method text of every scope line.
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS CISPR 11national version with changes
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+1 national
National versions in the same scope
AS/NZS CISPR 14.1national version with changes
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+1 national
National versions in the same scope
AS/NZS CISPR 32identical to it
FCC PART 15Radio Frequency Devices
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)+1 national
National versions in the same scope
AS/NZS 61000.3.2identical to it
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection+1 national
National versions in the same scope
AS/NZS 61000.3.3identical to it
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments+1 national
National versions in the same scope
AS/NZS 61000-6-3national version with changes
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments+1 national
National versions in the same scope
AS/NZS 61000-6-4probably the same standard; matched by number only
IEC 61000-6-14
47 CFR, FCC Part 15B; ANSI C63.4:2014; 47 CFR, FCC Part 18; MP-5:1986; CISPR 32; EN 55032; BS EN 55032; AS/NZS CISPR 32; J 55022; J 55032; VCCI V-3; CISPR 14-1; EN 55014-1; BS EN IEC 55014-1; AS/NZS CISPR 14.1; J 55014-1; CISPR 11; EN 55011; AS CISPR 11; BS EN 55011; J55011; ICES-001; ICES-003; ICES-005; BETS-7; EN 61000-6-3; AS/NZS 61000-6-3; BS EN 61000-6-3; EN IEC 61000-6-3; IEC 61000-6-3; BS EN IEC 61000-6-3; EN 61000-6-4; AS/NZS 61000-6-4; BS EN 61000-6-4; EN IEC 61000-6-4; IEC 61000-6-4; BS EN IEC 61000-6-14; EN 61000-3-2; EN 61000-3-3; AS/NZS 61000.3.2; EN IEC 61000-3-2; IEC 61000-3-2; BS EN IEC 61000-3-2; IEC 61000-3-3; AS/NZS 61000.3.3; JIS C61000-3-2; BS EN 61000-3-2; BS EN 61000-3-3; 47 CFR, FCC Part 15C; ANSI C63.10:2020; 47 CFR, FCC Part 15E; FCC KDB 905462 D02 (v02); 47 CFR, FCC Part 15F; 47 CFR, FCC Part 15H; RSS-GEN; RSS-210; RSS-216; RSS-247; RSS-248; RSS-310; AS/NZS 4268
ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2020; FCC KDB 905462 D02 (v02)
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.
Scope as published by A2LA
4 lines
ISO/IEC 17025
Active6426.01
The scope document we hold says it is valid until 2027-11-30.
Accredited scope, certificate 6426.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | 47 CFR, FCC Part 15B; ANSI C63.4:2014; 47 CFR, FCC Part 18; MP-5:1986; CISPR 32; EN 55032; BS EN 55032; AS/NZS CISPR 32; J 55022; J 55032; VCCI V-3; CISPR 14-1; EN 55014-1; BS EN IEC 55014-1; AS/NZS CISPR 14.1; J 55014-1; CISPR 11; EN 55011; AS CISPR 11; BS EN 55011; J55011; ICES-001; ICES-003; ICES-005; BETS-7; EN 61000-6-3; AS/NZS 61000-6-3; BS EN 61000-6-3; EN IEC 61000-6-3; IEC 61000-6-3; BS EN IEC 61000-6-3; EN 61000-6-4; AS/NZS 61000-6-4; BS EN 61000-6-4; EN IEC 61000-6-4; IEC 61000-6-4; BS EN IEC 61000-6-14; EN 61000-3-2; EN 61000-3-3; AS/NZS 61000.3.2; EN IEC 61000-3-2; IEC 61000-3-2; BS EN IEC 61000-3-2; IEC 61000-3-3; AS/NZS 61000.3.3; JIS C61000-3-2; BS EN 61000-3-2; BS EN 61000-3-3; 47 CFR, FCC Part 15C; ANSI C63.10:2020; 47 CFR, FCC Part 15E; FCC KDB 905462 D02 (v02); 47 CFR, FCC Part 15F; 47 CFR, FCC Part 15H; RSS-GEN; RSS-210; RSS-216; RSS-247; RSS-248; RSS-310; AS/NZS 4268 | - | to 40 GHz |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6426.01) Revised 10/14/2025 Page 2 of 3
Test Technology / Parameter(s): Test Method(s) / Standard(s) 1:
Radio Equipment
(cont.)
ARIB STD-T66; ARIB STD-T33; ARIB STD-T71;
Article 2-1-19; Article 2-1-19-2; Article 2-1-19-3; Article
2-1-19-3-2; Article 2-1-79; Article 2-1-80; Article 2-1-81;
ETSI EN 301 489-1; ETSI EN 301 489-3;
ETSI EN 301 489-5; ETSI EN 301 489-9;
ETSI EN 301 489-17;
ETSI EN 303 417; ETSI EN 302 208;
ETSI EN 300 330; ETSI EN 300 220-1;
ETSI EN 300 220-2; ETSI EN 300 220-3-1;
ETSI EN 300 220-3-2; ETSI EN 300 220-4;
ETSI EN 300 440; ETSI EN 300 328;
ETSI EN 301 893; ETSI EN 301 357;
ETSI EN 300 113; ETSI EN 300 086;
ETSI EN 300 296; ETSI EN 300 219;
ETSI EN 300 793; ETSI EN 300 390;
ETSI EN 300 433; ETSI EN 300 422-1;
ETSI EN 300 422-2; ETSI EN 300 422-3;
ETSI EN 300 422-4; ETSI EN 303 340;
ETSI EN 303 372-2; ETSI EN 303 687;
ETSI EN 303 413; ETSI EN 302 502
Immunity CISPR 14-2; EN 55014-2; BS EN 55014-2;
BS EN IEC 55014-2;
EN 61000-6-1; BS EN 61000-6-1; AS/NZS 61000.6.1;
EN IEC 61000-6-1; BS EN IEC 61000-6-1;
IEC 61000-6-1;
EN 61000-6-2; BS EN 61000-6-2; AS/NZS 61000.6.2;
EN IEC 61000-6-2; BS EN IEC 61000-6-2;
IEC 61000-6-2;
IEC 61000-4-2; EN 61000-4-2; BS EN 61000-4-2;
EN IEC 61000-4-2; BS EN IEC 61000-4-2;
IEC 61000-4-3; EN 61000-4-3; BS EN 61000-4-3;
EN IEC 61000-4-3; BS EN IEC 61000-4-3;
IEC 61000-4-4; EN 61000-4-4; BS EN 61000-4-4;
IEC 61000-4-5; EN 61000-4-5; BS EN 61000-4-5;
IEC 61000-4-6; EN 61000-4-6; BS EN 61000-4-6;
EN IEC 61000-4-6; BS EN IEC 61000-4-6;
IEC 61000-4-11; EN 61000-4-11; BS EN 61000-4-11;
EN IEC 61000-4-11; BS EN IEC 61000-4-11;
EN 50130-4; BS EN 50130-4;
CISPR 35; EN 55035; BS EN 55035;
IEC 60601-1-23; EN 60601-1-23; BS EN 60601-1-23
RF Exposure (MPE) ANSI C95.3;
Radio Communications
(Electromagnetic Radiation – Human);
EN 62311; EN 50665; EN 62479; EN 50663; EN 50385;
BS EN 62311; BS EN 50665; BS EN 62479;
BS EN 50663; EN IEC 62311; IEC 62311;
BS EN IEC 62311; IEC 50665; IEC 62479; IEC 50663 | ||
| 3 | ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2020; FCC KDB 905462 D02 (v02) | - | See scope document |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
SHENZHEN CENTRAL STANDARD INTERNATIONAL
CENTER CO., LTD.
Shenzhen, People’s Republic of China
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 23rd day of September 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 6426.01
Valid to November 30, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Labs with overlapping accredited scope in China
- Audix Technology (Wujiang)DAKKSShares 1 accredited test methodANSI C63.4:2014
- CTC Laboratories, Inc.Shenzhen, GuangdongA2LAShares 1 accredited test methodANSI C63.4:2014
- CTSL Testing (Dongguan) Co.,DongguanA2LAShares 1 accredited test methodANSI C63.4:2014
- DEKRA Testing and Certification (Shanghai)ShanghaiA2LAShares 1 accredited test methodANSI C63.4:2014
- DEKRA Testing and Certification (Suzhou) Co.,Suzhou, Jiangsu ProvinceA2LAShares 1 accredited test methodANSI C63.4:2014
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.