Registers refreshed 2026-11-08.See refresh dates
Germany

Wieland Electric GmbH Qualitätslabor

Brennerstraße 10-14, 96052, Bamberg, Germany

DAKKS D-PL-20465-01-00DAKKS D-PL-20465-01-01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
53
DAKKS certificates
2
Site in our directory
1
DAKKS accredited scope

What this lab is accredited for

Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 53 standard numbers and the 12 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 60512 series22
IEC 60512-1-1
IEC 60512-1-2
IEC 60512-2-1
IEC 60512-2-2
IEC 60512-2-5
IEC 60512-3-1
IEC 60512-4-1
IEC 60512-5-1
IEC 60512-5-2
IEC 60512-6-2
IEC 60512-6-3
IEC 60512-6-4
Show all 22
IEC 60512-6-5
IEC 60512-7-2
IEC 60512-9-1
IEC 60512-11-4
IEC 60512-11-9
IEC 60512-11-10
IEC 60512-13-5
IEC 60512-15-1
IEC 60512-17-3
IEC 60512-17-4
IEC 60068 series11
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)

Certificate says EN 60068-2-6. Probably the same standard; not checked against the EN document.

IEC 60068-2-11Environmental testing - Part 2-11: Tests - Test Ka: Salt mist
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-52Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution)
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance

Certificate says EN 60068-2-64. Probably the same standard; not checked against the EN document.

IEC 60068-2-75
IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
IEC5
IEC 60529Degrees of protection provided by enclosures (IP Code)

Certificate says EN 60529. Probably the same standard; not checked against the EN document.

IEC 60999-1
IEC 60999-2
IEC 61535
IEC 61984
IEC 60695 series5
IEC 60695-2-10
IEC 60695-2-11
IEC 60695-2-12
IEC 60695-2-13
IEC 60695-11-5
IEC 60947 series5
IEC 60947-1
IEC 60947-7-1
IEC 60947-7-2
IEC 60947-7-3
IEC 60947-7-4
IEC 60998 series4
IEC 60998-1
IEC 60998-2-1
IEC 60998-2-2
IEC 60998-2-3
Other standards1
ISO 6988Metallic and other non organic coatings - Sulfur dioxide test with general condensation of moisture

Read from the scope as published by DAKKS. Register refreshed 2026-11-06.

Scope as published by DAKKS

33 lines
DAKKS

ISO/IEC 17025

Active

D-PL-20465-01-00

View scope
DAKKS

ISO/IEC 17025

Active

D-PL-20465-01-01

View scope

Location

Brennerstraße 10-14, Bamberg, 96052, DE

49.90009, 10.90208

Open in Maps

Accreditation data refreshed from the DAKKS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.